Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “droop control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact of Increased Inverter Penetration on Power System Small-Signal Stability: Preprint

The transformation of the power system to include more distributed energy resources (DER) implies an increase in the number of inverter-based resources deployed on the grid. Envisioning future scenarios, this paper presents a small-signal stability analysis for a power grid comprising synchronous generators and inverter-based resources. Three types of inverter control are considered: grid following, droop-controlled grid forming, and virtual oscillator control grid forming. Although small-signal stability of power systems is a widely studied topic, systematic analysis of mixed machine-inverter systems with detailed control models at various inverter penetration levels are limited. This paper addresses the gap with numerical simulations tailored to the IEEE 39-bus system. Results show the system may become unstable at high inverter penetration level of grid-following inverters, and grid-forming inverter control can potentially improve system stability, thereby enabling very high level of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid Forming Inverter: Laboratory-Scale Hardware Test Bed Setup and Weak Grid Operation

In recent times, the concept of grid forming inverters has gained popularity. Grid forming inverters have proven to be a promising alternative to the grid following inverters. In this paper, we present the hardware test bed implementation of grid forming inverter in islanding mode as well as in grid connected mode. The control structure includes inverter-level inner current control and outer voltage control, and plant-level P - f and Q - V droop control. The Q - V droop provides the voltage command, whereas P - f droop provides the frequency command and is also key for the synchronization process. While it is straightforward to set up the test bed for the islanded operation, it is a challenging process to set up the grid-forming inverter in the grid-connected mode. We present the key technologies and demonstrate the start-up process and weak grid operation using the hardware experiment results. Results from EMT model developed in MATLAB/SimPowerSystems are also presented for side-by-side comparison.

Mittal, Ratik↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

Distributed Small-Signal Stability Conditions for Inverter-Based Unbalanced Microgrids

The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low-inertia offered by the power-electronics–interfaced energy resources, however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop-controller parameters and the network parameters (e.g. line impedances, loads). The distributed closed-form parametric stability conditions derived in this paper can be verified in a computationally efficient manner, facilitating reliable design and operations of networks of microgrids. Dynamic phasor models have been used to capture the effects of electromagnetic transients. Furthermore, numerical results are presented, along with PSCAD simulations, to validate the analytical stability conditions. Effects of design choices, such as the conductor types, and inverter sizes, on the small-signal stability of inverter-based microgrids are investigated to derive useful engineering insights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

black start↗

Large-Signal Stability of Phase-Balanced Equilibria in Single-Phase Grid-Forming Inverter Systems

This article explores the setup where large numbers of single-phase grid-forming inverters with droop control across distribution networks self-organize into a stable and balanced system with 120° phase offsets across aggregates in the absence of balanced three-phase generating resources or external communication. A suite of circuit- and system-theoretic notions are leveraged to derive a dynamical model for phase-angle differences across aggregates of inverters connected in the three phases. Focusing on this model, large-signal stability is established and the region of attraction of the phase-balanced equilibria is determined with the aid of a Lyapunov function. Experimental validation for a bench-top prototype network is included to support the analytical developments. Altogether, the effort supports the vision of facilitating balanced operation of distribution networks with grid-forming inverters during service disruptions at the bulk transmission network.

Droop control↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Quantitative Trade-Off in Distributed Secondary Control for Autonomous AC Microgrids

In this paper, we propose to quantify the trade-off between voltage regulation and reactive power sharing in autonomous AC microgrids with distributed secondary control. It is known that voltage regulation and reactive power sharing in droop-controlled autonomous AC microgrids are two conflicting control objectives that present a natural trade-off between voltage regulation towards the voltage magnitude reference and reactive power sharing accuracy. This trade-off is commonly shown qualitatively without sufficient quantification. In this work, to quantify the trade-off between the two objectives, we focus on distributed secondary control and utilize regression and polynomial surface fitting to identify the requisite parameter area to satisfy the predefined error bands for voltage magnitude regulation and reactive power sharing. Extensive case studies are presented to validate the proposed method.

autonomous AC microgrids↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Discovery of False Data Injection Attacks on Power Grid Frequency Controllers with Reinforcement Learning [Poster]

While inverter-based DER (distributed energy resources) are instrumental to integrating renewable energy into the power grid, they reduce the grid's mechanical inertia, thereby increasing the risk of frequency instabilities. To compensate for frequency instability risks, the grid must also undergo a transformation to include digital technologies that allow for two-way communication between the utility and customers. The current and future state of the power grid allows for building a cleaner energy landscape. However, the grid may also become vulnerable to novel cyber threats. To preemptively protect the power grid against elaborate cyber-attacks, we propose to discover potential threats via reinforcement learning. In this work, the focus is on studying false data injection attacks that target the control logic of frequency controllers. We show that a reinforcement learning agent can successfully discover how to best inject false data into linear droop controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Microgrid to Microgrid Synchronization with Grid-Forming Inverters: Challenges and Solution

Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.

Ferrari Maglia, Max↗