Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drift correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Analysis of Suomi - NPP VIIRS Vignetting Functions Based on Yaw Maneuver Data

The Suomi NPP Visible Infrared Imager Radiometer Suite (VIIRS) reflective bands are calibrated on-orbit via reference to regular solar observations through a solar attenuation screen (SAS) and diffusely reflected off a Spectralon (Registered Trademark) panel. The degradation of the Spectralon panel BRDF due to UV exposure is tracked via a ratioing radiometer (SDSM) which compares near simultaneous observations of the panel with direct observations of the sun (through a separate attenuation screen). On-orbit, the vignetting functions of both attenuation screens are most easily measured when the satellite performs a series of yaw maneuvers over a short period of time (thereby covering the yearly angular variation of solar observations in a couple of days). Because the SAS is fixed, only the product of the screen transmission and the panel BRDF was measured. Moreover, this product was measured by both VIIRS detectors as well as the SDSM detectors (albeit at different reflectance angles off the Spectralon panel). The SDSM screen is also fixed; in this case, the screen transmission was measured directly. Corrections for instrument drift and degradation, solar geometry, and spectral effects were taken into consideration. The resulting vignetting functions were then compared to the pre-launch measurements as well as models based on screen geometry.

Xiong, Xiaoxiong↗

Post-Flight EDL Entry Guidance Performance of the 2011 Mars Science Laboratory Mission

The 2011 Mars Science Laboratory was the first Mars guided entry which safely delivered the rover to a landing within a touchdown ellipse of 19.1 km x 6.9 km. The Entry Terminal Point Controller guidance algorithm is derived from the final phase Apollo Command Module guidance and, like Apollo, modulates the bank angle to control the range flown. The guided entry performed as designed without any significant exceptions. The Curiosity rover was delivered about 2.2 km from the expected touchdown. This miss distance is attributed to little time to correct the downrange drift from the final bank reversal and a suspected tailwind during heading alignment. The successful guided entry for the Mars Science Laboratory lays the foundation for future Mars missions to improve upon.

Mendeck, Gavin F.↗

Temporal Gain Correction for X-Ray Calorimeter Spectrometers

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-HSXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

X-ray detector X-ray spectrometer X-ray calorimete↗

Trace Elemental Abundances in Calcium-Aluminum-Rich Inclusions in CV Chondrites

Introduction: Calcium-aluminum-rich inclusions (CAIs), are the first formed solids that define the age of the Solar System [1,2]. CAIs are thought to have condensed from nebular gas [3,4] within the first <1 Ma of Solar System formation [5,6]. CAIs have experienced numerous early Solar System processes including condensation, evaporation, melting, recrystallization, and aqueous alteration [e.g., 7]. The chemical, mineralogical, and textural diversity among CAIs results from a range of chemical and physical processes recorded during nebular and parent body epoch. This study aims to explore the mineralogical, textural, and chemical compositions of CAIs including the trace elemental abundances in CAI phases to determine the early Solar System processes recorded in them. Samples and Analytical Methods: We analyzed one CAI each from CV3 chondrites Northwest Africa (NWA) 5508 designated as ‘Saguaro’, and Northwest Africa (NWA) 12772 designated as ‘Hoopoe’. Back-scatter electron (BSE) images were collected using a Phenom XL scanning electron microscope (SEM) at the Lunar and Planetary Institute (LPI) and the JEOL JXA-8530F electron probe microanalyzer (EPMA) at Johnson Space Center (JSC)-NASA. Additionally, energy dispersive X-ray spectrometry (EDS) elemental maps of select areas for these samples were collected using a 15.0kV beam energy and a 40µA emission current. Using the EPMA, wavelength-dispersive X-ray spectroscopy (WDS) quantitative data were collected. In-situ trace element measurements for both CAIs were determined at JSC-NASA using a Photon Machines 193nm laser ablation system and a Thermo-Scientific Element-XR inductively coupled plasma mass spectrometer (ICP-MS). Analyses consisted of 30s ablations at 10Hz, spot sizes of 20-25µm, and a fluence of 6.0 J/cm2 for anorthite and melilite, and a 3.5 J/cm2 fluence for all other phases. NIST612 was used to correct for instrument drift, while BHVO-2g was used as a primary calibration standard. BCR-2g and in-house mineral standards were regularly measured as unknowns to ensure accuracy. Results: Saguaro is a coarse-grained CAI, ~11 x 6 mm in dimensions. Saguaro contains spinel, Al-rich pyroxene, anorthite, Mg-rich melilite, and minor perovskite in its interior and is therefore classified as a Type B CAI. Individual melilite grains shows normal compositional zoning with an Ak content ranging from ~24 to 54 with no apparent trend from the core to the edge of the CAI. The spinel appears euhedral and occurs both as clusters and as spinel palisades [8]. Two rim sequences surround most of the sample: the inner rim being a Wark-Lovering (WL) rim (~10-35 µm) containing pyroxene, spinel, and melilite (or anorthite), and the outer rim is a finer-grained, thicker (~100 µm), accretionary rim (Fig. 1). The mineral phases in Saguaro record an overall flat REE pattern with an average negative Eu anomaly in pyroxene, and an average positive Eu anomaly in anorthite and melilite respectively. Anorthite, melilite, and pyroxene have a minor depletion in Tm (Fig. 2). The Hoopoe CAI is a compact, coarse-grained ~6 × 4 mm in size. The major mineralogy includes hibonite, spinel, melilite, anorthite, and perovskite. Therefore, it is classified as a compact transitional type A and B. (?)zoning was observed in some hibonites. Individual melilite grains show both reverse and normal zoning, where the Ak content ranges from ~6- to 28. Melilite shows two distinct textures. One texture consisted of smooth melilite that appeared homogenous, while the second appeared to consist of many fine fractures. The spinel also often appears clustered. The WL-rim sequence surrounding Hoopoe is ~25 µm thick and composed of spinel, perovskite, hibonite, and melilite/anorthite. It is then partially surrounded by an outer accretionary rim (~75µm). Like before, refractory metal nuggets appeared concentrated near the WL rims. Other metal assemblages rich in Fe and Ni were also observed. All major mineral phases in Hoopoe display relatively flat REE patterns, except for varying Eu and Tm between phases (Fig. 2). There is a prominent negative Eu anomaly in perovskite and an average positive Eu anomaly in spinel, anorthite, and hibonite respectively (Fig. 2, 3). The mixed phases along the rim of the CAI also display a negative Eu anomaly, and all phases the CAI were depleted in Pb. Discussion: The CV3 CAIs analyzed in this study were classified based on their mineralogy and textures into Type A versus Type B CAIs [10]. Hibonite appears to be pseudomorphically replacing the spinel, (i.e., is hibonite in composition, but appears in the shape of spinel). Spinel palisades. The presence of spinel palisades present in Saguaro are consistent with the melting and recrystallization experienced by this CAI. Trace elemental analyses. Saguaro and Hoopoe display similar trace element patterns to each other, with both appearing generally flat, with anomalies in Eu, and Tm. Melilite and anorthite display positive Eu anomalies in both CAIs, in addition to the hibonite in Hoopoe (Fig. 2). The phases that are depleted in Eu are pyroxene and perovskite in both Saguaro and Hoopoe, respectively (Fig. 3). Given that Eu is volatile in reducing environments [11], this could possibly indicate reducing conditions at the time anorthite and melilite crystallized, with the gas they formed from containing Eu. As these CAIs continued to form, this gas as a result would become depleted in Eu. This also could be supported by the propensity of anorthite and melilite to take up Eu from its surroundings and incorporate it into their structure [12]. In addition, analyzing the assemblage of the phases in the Saguaro, melilite and anorthite (Eu enriched) often surround the pyroxene (Eu depleted) as they are crystallized. This intergrowth of phases and the proximity of the phases would support that the Eu is being incorporated into some phases, preventing it from incorporating into other. Trace elemental analyses of the CAI rims will be evaluated in more detail, as they are complicated by the transient signal being composed of a mixture of mineral phases. Broadly, however, the patterns in the rims of both CAIs are comparable to each other, and for Hoopoe, to the mixed phase patterns in the core (Fig. 3). Other studies have found that CAI rims can be depleted in Ce and Yb [13], however we did not observe these anomalies in the two CAIs discussed here. Given their similarity, the trace elemental analyses of the mixed interior (i.e. core) and rim phases could be interpreted as forming from similar, if not the same, reservoirs. The REE abundance between the rim and core of Hoopoe are also similar, indicating they may have formed from a gas of the same or similar composition. Acknowledgments: We thank the ASU Center for Meteorite Studies for loaning the samples used in this work and Tabb Prissel for his assistance with the analysis. Mouti Al-Hashimi thanks Sam Crossley and Cyrena Goodrich for their help with the LPI SEM training. This work was supported by the LPI Summer Intern Program in Planetary Science and the LPI Cooperative Agreement. References: [1] Connelly J.N. (2012) Science, 338, 651-655. [2] MacPherson G. J. (2014) Treatise on Geochem., 2, 139-179. [3] Grossman L. (1972) GCA, 36, 597-619. [4] Ebel, D.S. (2006) Meteorites and the Early Solar System II (D. S. Lauretta & H. Y. McSween, Eds.) 253-277. [5] MacPherson G. J. (2012) Earth Planet. Sci. Lett., 331-332, 43-54. [6] MacPherson G.J. (2017) GCA, 201, 65-82. [7] Krot A.N. (1995) Meteoritics & Planet. Sci., 30, 748-775. [8] Wark and Lovering (1982) GCA, 46, 2595-2607. [9] Palme H. and Jones A. (2003) Treatise on Geochemistry (H. D. Holland and K. K. Turekian Eds.), 1, 41-61. [10] Grossman L. (1980) Ann. Rev. Earth Planet. Sci., 8, 559-608. [11] Floss C. et al. (1996) GCA, 60, 1975-1997. [12] Mason B. and Martin P. M. (1974) Earth Planet. Sci. Lett., 22, 141-144. [13] Wark B. and Boynton W. V. (2001) Meteoritics & Planet. Sci., 36, 1135-1166.

X Mouti↗

Microbial Optical Data Processing: A Key Step in the Metabolic Assessment of Lunar Explorer Instrument for Space Biology Applications (LEIA) and Biosentinel’s Payload Data

The BioSensor payload platform on BioSentinel and LEIA autonomously collects optical data from microbial model organisms in liquid culture. The BioSensor is designed to monitor metabolic activity using absorbance measurements of cell density and alamarBlue, a readily available colorimetric redox indicator dye. BioSentinel, a pioneering NASA CubeSat, uses yeast to study deep space radiation. LEIA investigates radiation and lunar gravity response. The experimental setup includes 16 wells equipped with three LEDs (570, 630, and 850 nm) and their corresponding photodetectors. One well is a calibration control without biology while the rest have desiccated cultures. Autonomous rehydration initiates the experiment. Data from the BioSensor are received from the flight and ground units, enabling comparison to uncover location-based metabolic rate variations. This study presents a Python Jupyter notebook developed for efficient data processing of multiple CSV files containing date and time columns, temperature, and well illumination data. It offers a user-friendly interface while maintaining computational power, automatically recognizing and iteratively processing data files in a user-input path. A Hampel filter with a short window eliminates outlier artifacts from sensor dropout. Because absorbance is a relative measurement, conversion from raw illumination requires defining a “blank” value, so the first data points are averaged to provide the necessary denominator. A cube-root function correction mitigates undesired drift caused by air pockets during the fluidic card filling phase, maintaining optical path length consistency. Beer-Lambert's law is applied to further convert absorbance values to cell and dye form concentrations, the desired science parameters. The processed data are saved and visualized as SVG plots. Future plans include extracting specific science parameters from the processed data like growth rate and metabolic rate, and identification of features corresponding to metabolic and phenotypic shifts such as starvation, shifts from aerobic to anaerobic growth, and osmotic stresses.

Space biology↗

Spacecraft antenna pointing

Two degree of freedom spacecraft antenna pointing system evaluation based on geometry, attitude drift errors, and sensor error signal methods of correcting antenna position for attitude drift

ERROR SIGNAL↗

Power Measurement Errors on a Utility Aircraft

Extensive flight test data obtained from two recent performance tests of a UH 60A aircraft are reviewed. A power difference is calculated from the power balance equation and is used to examine power measurement errors. It is shown that the baseline measurement errors are highly non-Gaussian in their frequency distribution and are therefore influenced by additional, unquantified variables. Linear regression is used to examine the influence of other variables and it is shown that a substantial portion of the variance depends upon measurements of atmospheric parameters. Correcting for temperature dependence, although reducing the variance in the measurement errors, still leaves unquantified effects. Examination of the power difference over individual test runs indicates significant errors from drift, although it is unclear how these may be corrected. In an idealized case, where the drift is correctable, it is shown that the power measurement errors are significantly reduced and the error distribution is Gaussian. A new flight test program is recommended that will quantify the thermal environment for all torque measurements on the UH 60. Subsequently, the torque measurement systems will be recalibrated based on the measured thermal environment and a new power measurement assessment performed.

Bousman, William G.↗

MODIS Reflective Solar Bands Calibration Improvements for Collection 7

Calibration of Terra and Aqua MODIS reflective solar bands (RSB) has evolved significantly since the launch of the first MODIS instrument on the Terra satellite more than 21 years ago. In NASA’s current Collection 6 and 6.1 Level 1B products (C6/C6.1 L1B), the RSB calibration algorithm continues to rely primarily on the onboard solar diffuser to calibrate the instrument gain. Lunar observations are used to track on-orbit changes in the response versus scan angle (RVS), and data from pseudo-invariant desert sites are used to apply adjustments to the gain and RVS calibration for select bands. The resulting reflectance products have in general shown a very stable performance. In recent years, some performance degradation has been noted for a few bands and algorithm changes have been tested to further improve the calibration accuracy for the upcoming Collection 7 (C7) L1B reprocess. In this paper, we present the MODIS RSB calibration improvements that will be included in C7. Major improvements include: applying polarization correction to the desert data before using it to generateRVS for Terra bands 8, 9, 3, and 10; using ocean scene data and an interband calibration approach to correct for long-term drift of Terra bands 11 and 12; applying an updated crosstalk correction to Terra SWIR bands over the entire mission; and using data from deep convective clouds in Terra SWIR band calibration, including the addition of time-dependent RVS for bands 5 and 26. All other minor calibration changes are also covered. Overall, the reflectance differences at nadir between C6.1 and C7 are within a few percent, though the differences increase in some cases at large scan angles. The Terra visible (3, 8-12) and SWIR bands (5-7, 26) have the most significant improvements. For all other Terra bands and all Aqua bands, the C7-C6.1 differences are mostly within 1%

MODIS↗

LANDSAT-D program. Volume 2: Ground segment

Raw digital data, as received from the LANDSAT spacecraft, cannot generate images that meet specifications. Radiometric corrections must be made to compensate for aging and for differences in sensitivity among the instrument sensors. Geometric corrections must be made to compensate for off-nadir look angle, and to calculate spacecraft drift from its prescribed path. Corrections must also be made for look-angle jitter caused by vibrations induced by spacecraft equipment. The major components of the LANDSAT ground segment and their functions are discussed.

Source record↗

Retrieval of Ozone Profile from Ground-Base Zenith Sky Measurements

In this talk I will discuss recent results from examining the information content in zenith sky UV (ZUV) measurements from ground for the retrieval of vertical ozone profile. Our results indicate that ZUV can provide high quality ozone profile from ground to 50 km at roughly 10 krn vertical resolution that can be used for the calibration of satellite instruments. However, to take advantage of this the instruments must be better calibrated and it is also necessary that the ground-based Brewer instruments are operated in a mode that is different from the routine operational mode. This will allow one to correct for instrument calibration drifts and to remove noise due to clouds and aerosols. A key technical issue is if the instrument can be reprogrammed to do so.

Bhartia, P. K.↗

Design and Performance of the Keck Angle Tracker

The Keck Angle Tracker (KAT) is a key subsystem in the NASA-funded Keck Interferometer at the Keck Observatory on the summit of Mauna Kea in Hawaii. KAT, which has been in operation since the achievement of first fringes in March 2001, senses the tilt of the stellar wavefront for each of the beams from the interferometer telescopes and provides tilt error signals to fast tip/tilt mirrors for high-bandwidth, wavefront tilt correction. In addition, KAT passes low-bandwidth, desaturation offsets to the adaptive optics system of the Keck telescopes to correct for slow pointing drifts. We present an overview of the instrument design and recent performance of KAT in support of the V2 science and nulling observing modes of the Keck Interferometer.

adaptive optics↗

The Local Stellar Velocity Field via Vector Spherical Harmonics

We analyze the local field of stellar tangential velocities for a sample of 42,339 nonbinary Hipparcos stars with accurate parallaxes, using a vector spherical harmonic formalism. We derive simple relations between the parameters of the classical linear model (Ogorodnikov-Milne) of the local systemic field and low-degree terms of the general vector harmonic decomposition. Taking advantage of these relationships, we determine the solar velocity with respect to the local stars of (V(sub X), V(sub Y), V(sub Z)) (10.5, 18.5, 7.3) +/- 0.1 km s(exp -1) not corrected for the asymmetric drift with respect to the local standard of rest. If only stars more distant than 100 pc are considered, the peculiar solar motion is (V(sub X), V(sub Y), V(sub Z)) (9.9, 15.6, 6.9) +/- 0.2 km s(exp -1). The adverse effects of harmonic leakage, which occurs between the reflex solar motion represented by the three electric vector harmonics in the velocity space and higher degree harmonics in the proper-motion space, are eliminated in our analysis by direct subtraction of the reflex solar velocity in its tangential components for each star. The Oort parameters determined by a straightforward least-squares adjustment in vector spherical harmonics are A=14.0 +/- 1.4, B=13.1 +/- 1.2, K=1.1 +/- 1.8, and C=2.9 +/- 1.4 km s(exp -1) kpc(exp -1). The physical meaning and the implications of these parameters are discussed in the framework of a general linear model of the velocity field. We find a few statistically significant higher degree harmonic terms that do not correspond to any parameters in the classical linear model. One of them, a third-degree electric harmonic, is tentatively explained as the response to a negative linear gradient of rotation velocity with distance from the Galactic plane, which we estimate at approximately -20 km s(exp -1) kpc(exp -1). A similar vertical gradient of rotation velocity has been detected for more distant stars representing the thick disk (z greater than 1 kpc), but here we surmise its existence in the thin disk at z less than 200 pc. The most unexpected and unexplained term within the Ogorodnikov-Milne model is the first-degree magnetic harmonic, representing a rigid rotation of the stellar field about the axis -Y pointing opposite to the direction of rotation. This harmonic comes out with a statistically robust coefficient of 6.2 +/- 0.9 km s(exp -1) kpc(exp -1) and is also present in the velocity field of more distant stars. The ensuing upward vertical motion of stars in the general direction of the Galactic center and the downward motion in the anticenter direction are opposite to the vector field expected from the stationary Galactic warp model.

Galaxy↗

Application of Quasi-Deep Convective Clouds Method for VIIRS and MODIS TEB Calibration Assessments

A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit blackbody (BB) warm-up and cooldown operations for updates. However, a limited BB temperature range affects the calibration’s accuracy particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide with the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, this qDCC method is applied to the Terra MODIS and VIIRS TEB; and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31 and VIIRS bands M15 and I5, are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows their TEB measurements are consistent over qDCC. The Terra MODIS TEB also show stable performance – except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, while bands 27 and 29 show slight, upward drifts. Lastly, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.

MODIS↗

Results of the REFLEX (Return Flux Experiment) Flight Mission

The numerous problems occurring in this first flight of the REFLEX experiment, both in the spacecraft and with the instrument package, seriously constrained the acquisition and analysis of data and severely limited the interpretation of the data that were obtained. Of these, the ambient helium measurements appear to be the most promising. They are summarized and discussed in Appendix A. Further analyses could be attempted to establish the correct values for the energy centers as they varied during the mission. In addition, an extensive laboratory recalibration on a high-speed beam system could in principle provide corrections to be used in analyzing and interpreting the returned data set. The unknown malfunction which generated the energy drift needs to be understood and corrected before the REFLEX experiment is reflown; some hardware modification, or at least retuning, is likely to be required.

Pepin, R. O.↗

Efficient Multi-Dimensional Simulation of Quantum Confinement Effects in Advanced MOS Devices

We investigate the density-gradient (DG) transport model for efficient multi-dimensional simulation of quantum confinement effects in advanced MOS devices. The formulation of the DG model is described as a quantum correction to the classical drift-diffusion model. Quantum confinement effects are shown to be significant in sub-100nm MOSFETs. In thin-oxide MOS capacitors, quantum effects may reduce gate capacitance by 25% or more. As a result, the inclusion or quantum effects in simulations dramatically improves the match between C-V simulations and measurements for oxide thickness down to 2 nm. Significant quantum corrections also occur in the I-V characteristics of short-channel (30 to 100 nm) n-MOSFETs, with current drive reduced by up to 70%. This effect is shown to result from reduced inversion charge due to quantum confinement of electrons in the channel. Also, subthreshold slope is degraded by 15 to 20 mV/decade with the inclusion of quantum effects via the density-gradient model, and short channel effects (in particular, drain-induced barrier lowering) are noticeably increased.

Biegel, Bryan A.↗

Efficient Multi-Dimensional Simulation of Quantum Confinement Effects in Advanced MOS Devices

We investigate the density-gradient (DG) transport model for efficient multi-dimensional simulation of quantum confinement effects in advanced MOS devices. The formulation of the DG model is described as a quantum correction ot the classical drift-diffusion model. Quantum confinement effects are shown to be significant in sub-100nm MOSFETs. In thin-oxide MOS capacitors, quantum effects may reduce gate capacitance by 25% or more. As a result, the inclusion of quantum effects may reduce gate capacitance by 25% or more. As a result, the inclusion of quantum effects in simulations dramatically improves the match between C-V simulations and measurements for oxide thickness down to 2 nm. Significant quantum corrections also occur in the I-V characteristics of short-channel (30 to 100 nm) n-MOSFETs, with current drive reduced by up to 70%. This effect is shown to result from reduced inversion charge due to quantum confinement of electrons in the channel. Also, subthreshold slope is degraded by 15 to 20 mV/decade with the inclusion of quantum effects via the density-gradient model, and short channel effects (in particular, drain-induced barrier lowering) are noticeably increased.

Biegel, Bryan A.↗

On the length of the drift region in the Ramsey cavity

The interaction of atoms in a beam with the microwave field in a separated field geometry such as a Ramsey cavity is generally described in terms of the three regions traversed successively by the atoms, namely two interaction regions of length (l) separated by a drift, or free precession, region of length L. For a monokinetic beam of velocity v, the linewidth of the central fringe in the Ramsey resonance pattern is usually expressed as delta omega equals pi v/L. A more detailed calculation shows, however, that the linewidth is equal to pi v/L asterisk, where the equivalent drift L asterisk is larger than L by an amount of the order of l/L. The correction depends on the field distribution in the interaction regions. Its origin lies in the fact that atomic precession is not limited to the field-free regions but also occurs in the interaction regions, where atomic coherence builds up or decreases continuously. Although the correction to the equivalent length of the drift region is small, it may be relevant to the evaluation of the second-order Doppler effect bias in primary cesium-beam standards to the extent that the atomic velocity is deduced from the lineshape and from the geometrical parameters of the cavity. It is shown that in current and projected standards with atoms of average thermal velocity, use of corrected dimensions may lead to a change of the calculated bias of the order of 10(exp -14), which is significant at the levels of accuracy considered nowadays.

Thomann, Pierre↗

Electromagnetic Flow Meter Having a Driver Circuit Including a Current Transducer

An electromagnetic flow meter (EMFM) accurately measures both the complete flow rate and the dynamically fluctuating flow rate of a fluid by applying a unipolar DC voltage to excitation coils for a predetermined period of time, measuring the electric potential at a pair of electrodes, determining a complete flow rate and independently measuring the dynamic flow rate during the "on" cycle of the DC excitation, and correcting the measurements for errors resulting from galvanic drift and other effects on the electric potential. The EMFM can also correct for effects from the excitation circuit induced during operation of the EMFM.

Karon, David M.↗