Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose, detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of radiation interference in the Voyager Sun Sensor's cadmium sulfide detector

The simulation of radiation interference effects and the results of a radiation interference test on two Voyager Sun Sensor prototype detector assemblies are reported. The derivation of test levels and requirements are discussed and show that cobalt 60 gamma radiation is an effective and practical simulator of the ionization dose rate effects induced by high-energy electron flux incident on the spacecraft at a rate of 3.7 x 10 to the 8th e/sq cm-sec (10 rad(Si)/s) during closest approach to Jupiter. The test results provide information that is used to confirm an analytic correlation, and to predict satisfactory performance of a spacecraft sun sensing device having stringent angular resolution requirements. The measured detector response shows that at dose rates incident on the detector elements of 2 rad(Si)/sec, which is four times that expected during Jupiter encounter, the radiation-induced angle error is almost an order of magnitude less than that allowed by the acceptance criteria.

Clarke, T. C.↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day(exp -1) have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLD's) made in U.S.S.R. and U.S.A. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

Watts, J. W., Jr.↗

On the use of Lineal Energy Measurements to Estimate Linear Energy Transfer Spectra

This paper examines the error resulting from using a lineal energy spectrum to represent a linear energy transfer spectrum for applications in the space radiation environment. Lineal energy and linear energy transfer spectra are compared in three diverse but typical space radiation environments. Different detector geometries are also studied to determine how they affect the error. LET spectra are typically used to compute dose equivalent for radiation hazard estimation and single event effect rates to estimate radiation effects on electronics. The errors in the estimations of dose equivalent and single event rates that result from substituting lineal energy spectra for linear energy spectra are examined. It is found that this substitution has little effect on dose equivalent estimates in interplanetary quiet-time environment regardless of detector shape. The substitution has more of an effect when the environment is dominated by solar energetic particles or trapped radiation, but even then the errors are minor especially if a spherical detector is used. For single event estimation, the effect of the substitution can be large if the threshold for the single event effect is near where the linear energy spectrum drops suddenly. It is judged that single event rate estimates made from lineal energy spectra are unreliable and the use of lineal energy spectra for single event rate estimation should be avoided.

Adams, David A.↗

A portable absorbed dose measuring instrument with gamma discrimination

The characteristics of an electronic instrument for measuring the radiation dose absorbed by tissues are presented. The detector is a sphere of tissue-equivalent plastic with a single wire located on a diameter of the sphere. The electronic circuits and method of operation of the detector are described. Advantages are the small size and easy portability plus ability to selectively measure neutron and gamma plus neutron events.

Quam, W. M.↗

Electron, electron-bremsstrahlung and proton depth-dose data for space-shielding applications

A data set has been developed, consisting of depth-dose distributions for omni-directional electron and proton fluxes incident on aluminum shields. The principal new feature of this work is the accurate treatment, based on detailed Monte Carlo calculations, of the electron-produced bremsstrahlung component. Results covering the energy region of interest in space-shielding calculations have been obtained for the absorbed dose (a) as a function of depth in a semi-infinite medium, (b) at the edge of slab shields, and (c) at the center of a solid sphere. The dose to a thin tissue-equivalent detector was obtained as well as that in aluminum. Various results and comparisons with other work are given.

Seltzer, S. M.↗

STRV RADMON: An integrated high-energy particle detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude. On the STRV (Space Technology Research Vehicle) the RADMON's SRAM will be used to detect trapped protons, solar flares, and cosmic rays and to evaluate our ability to predict space results from ground tests.

Buehler, Martin↗

Evaluation of HZETRN on the Martian Surface: Sensitivity Tests and Model Results

The Mars Science Laboratory Radiation Assessment Detector (MSLRAD) is providing continuous measurements of dose, dose equivalent, and particle flux on the surface of Mars. These measurements have been highly useful in validating environmental and radiation transport models that will be heavily relied upon for future deep space missions. In this work, the HZETRN code is utilized to estimate radiation quantities of interest on the Martian surface. A description of the modeling approach used with HZETRN is given along with the various input models and parameters used to define the galactic cosmic ray (GCR) environment and Martian geometry. Sensitivity tests are performed to gauge the impact of varying several input factors on quantities being compared to MSLRAD data. Results from these tests provide context for inter-code comparisons presented in a companion paper within this issue. It is found that details of the regolith and atmospheric composition have a minimal impact on surface flux, dose, and dose equivalent. Details of the density variation within the atmosphere and uncertainties associated with specifying the vertical atmospheric thickness are also found to have minimal impact. Two widely used GCR models are used as input into HZETRN and it is found that the associated surface quantities are within several percent of each other.

Tony C Slaba↗

STRV RADMON: An Integrated High-Energy Particle Detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude.

RADMON↗

Absorbed dose and LET spectra measurements on LDEF

Total absorbed doses measured with TLD's, linear energy transfer (LET) spectra measured with plastic track detectors, and low energy neutrons measured on LDEF have been compared with model calculations. The total absorbed doses measured in TLD's were higher than predicted in the calculations of Armstrong et al. and differ from the calculations of Atwell et al. LDEF LET spectra are dependent on detector orientation, shielding and experiment location. These factors need to be taken into account when modeling the LDEF LET spectra. LET spectra measured with plastic nuclear track detectors (PNTD's) also deviate significantly from calculations especially for high LET particles (LET(sub infinity) H2O greater than 100keV/micron). Modeling efforts to date do not include the contribution of proton induced secondaries. Analysis of polycarbonate PNTD's from the West-side of LDEF has revealed a very high fluence of tracks (greater than 1 x 10(exp 7) tracks/cm(exp 2) under 2 gm/cm(exp 2) shielding). Fluence drops off rapidly as shielding depth increases. Tracks only form in the region of the detector closest to the surface, not in the bulk of the detector. To date no adequate explanation for this observation has been found. We plan to measure range distribution of very high LET (LET (sub infinity) H2O greater than 500 keV/micron) secondary particles produced in silicon wafer by high energy primary cosmic ray particles. Refinements of experimental techniques and model calculations are being carried out in order to understand existing discrepancies between experimental measurements and calculations.

Benton, E. V.↗

Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation

Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.

NASA Discipline Radiation Health↗

Automated ISS Flight Utilities

During my internship at NASA Johnson Space Center, I worked in the Space Radiation Analysis Group (SRAG), where I was tasked with a number of projects focused on the automation of tasks and activities related to the operation of the International Space Station (ISS). As I worked on a number of projects, I have written short sections below to give a description for each, followed by more general remarks on the internship experience. My first project is titled "General Exposure Representation EVADOSE", also known as "GEnEVADOSE". This project involved the design and development of a C++/ ROOT framework focused on radiation exposure for extravehicular activity (EVA) planning for the ISS. The utility helps mission managers plan EVAs by displaying information on the cumulative radiation doses that crew will receive during an EVA as a function of the egress time and duration of the activity. SRAG uses a utility called EVADOSE, employing a model of the space radiation environment in low Earth orbit to predict these doses, as while outside the ISS the astronauts will have less shielding from charged particles such as electrons and protons. However, EVADOSE output is cumbersome to work with, and prior to GEnEVADOSE, querying data and producing graphs of ISS trajectories and cumulative doses versus egress time required manual work in Microsoft Excel. GEnEVADOSE automates all this work, reading in EVADOSE output file(s) along with a plaintext file input by the user providing input parameters. GEnEVADOSE will output a text file containing all the necessary dosimetry for each proposed EVA egress time, for each specified EVADOSE file. It also plots cumulative dose versus egress time and the ISS trajectory, and displays all of this information in an auto-generated presentation made in LaTeX. New features have also been added, such as best-case scenarios (egress times corresponding to the least dose), interpolated curves for trajectories, and the ability to query any time in the EVADES output. As mentioned above, GEnEVADOSE makes extensive use of ROOT version 6, the data analysis framework developed at the European Organization for Nuclear Research (CERN), and the code is written to the C++11 standard (as are the other projects). My second project is the Automated Mission Reference Exposure Utility (AMREU).Unlike GEnEVADOSE, AMREU is a combination of three frameworks written in both Python and C++, also making use of ROOT (and PyROOT). Run as a combination of daily and weekly cron jobs, these macros query the SRAG database system to determine the active ISS missions, and query minute-by-minute radiation dose information from ISS-TEPC (Tissue Equivalent Proportional Counter), one of the radiation detectors onboard the ISS. Using this information, AMREU creates a corrected data set of daily radiation doses, addressing situations where TEPC may be offline or locked up by correcting doses for days with less than 95% live time (the total amount time the instrument acquires data) by averaging the past 7 days. As not all errors may be automatically detectable, AMREU also allows for manual corrections, checking an updated plaintext file each time it runs. With the corrected data, AMREU generates cumulative dose plots for each mission, and uses a Python script to generate a flight note file (.docx format) containing these plots, as well as information sections to be filled in and modified by the space weather environment officers with information specific to the week. AMREU is set up to run without requiring any user input, and it automatically archives old flight notes and information files for missions that are no longer active. My other projects involve cleaning up a large data set from the Charged Particle Directional Spectrometer (CPDS), joining together many different data sets in order to clean up information in SRAG SQL databases, and developing other automated utilities for displaying information on active solar regions, that may be used by the space weather environment officers to monitor solar activity. I consulted my mentor Dr. Ryan Rios and Dr. Kerry Lee for project requirements and added features, and ROOT developer Edmond Offermann for advice on using the ROOT library. I also received advice and feedback from Dr. Janet Barzilla of SRAG, who tested my code. Besides these inputs, I worked independently, writing all of the code by myself. The code for all these projects is documented throughout, and I have attempted to write it in a modular format. Assuming that ROOT is updated accordingly, these codes are also Y2038-compliant (and Y10K-compliant). This allows the code to be easily referenced, modified and possibly repurposed for non-ISS missions in the future, should the necessary inputs exist. These projects have taught me a lot about coding and software design - I have become a much more skilled C++ programmer and ROOT user, and I also learned to code in Python and PyROOT (and its advantages and disadvantages compared to C++/ ROOT). Furthermore, I have learned about space radiation and radiation modeling, topics that greatly interest me as I pursue a degree in physics. Working alongside experimental physicists like Dr. Rios, I have developed a greater understanding and appreciation for experimental science, something I have always leaned towards but to which I lacked significant exposure. My work in SRAG has also given me the invaluable opportunity to witness the work environment for physicists at NASA, and what a career in academia may look like at a government laboratory such as NASA Johnson Space Center. As I continue my studies and look forward to graduate school and a future career, this experience at NASA has given me a meaningful and enjoyable opportunity to put my skills to use and see what my future career path might hold.

Offermann, Jan Tuzlic↗

Simulation and Comparison of Martian Surface Ionization Radiation

The spectrum of energetic particle radiation and corresponding doses at the surface of Mars is being characterized by the Radiation Assessment Detector (RAD), one of ten science instruments on the Mars Science Laboratory (MSL) Curiosity Rover. The time series of dose rate for the first 300 Sols after landing on Mars on August 6, 2012 is presented here. For the comparison to RAD measurements of dose rate, Martian surface ionization radiation is simulated by utilizing observed space quantities. The GCR primary radiation spectrum is calculated by using the Badhwar-O'Neill 2011 (BO11) galactic cosmic ray (GCR) model, which has been developed by utilizing all balloon and satellite GCR measurements since 1955 and the newer 1997-2012 Advanced Composition Explorer (ACE) measurements. In the BO11 model, solar modulation of the GCR primary radiation spectrum is described in terms of the international smoothed sunspot number and a time delay function. For the transport of the impingent GCR primary radiation through Mars atmosphere, a vertical distribution of atmospheric thickness at each elevation is calculated using the vertical profiles of atmospheric temperature and pressure made by Mars Global Surveyor measurements. At Gale Crater in the southern hemisphere, the seasonal variation of atmospheric thickness is accounted for the daily atmospheric pressure measurements of the MSL Rover Environmental Monitoring Station (REMS) by using low- and high-density models for cool- and warm-season, respectively. The spherically distributed atmospheric distance is traced along the slant path, and the resultant directional shielding by Martian atmosphere is coupled with Curiosity vehicle for dose estimates. We present predictions of dose rate and comparison to the RAD measurements. The simulation agrees to within +/- 20% with the RAD measurements showing clearly the variation of dose rate by heliospheric conditions, and presenting the sensitivity of dose rate by atmospheric pressure, which has been found from the RAD experiments and driven by thermal tides on Martian surface.

Kim, Myung-Hee Y.↗

Electrolytic Co-deposition Neutron Production Evaluation

Co-deposition electrochemical cells are a simple means to examine novel nuclear reactions. In this study, palladium and deuterium atoms were co-deposited on a cathode at stoichiometric densities, forming dendritic morphologies. Bubble detector neutron dosimeters were used to measure equivalent dose levels during electrolytic deposition. Standard configuration cells expected to produce excess neutrons were denoted as experimental cells and contained an electrolyte consisting of palladium(II) chloride, lithium chloride, and heavy water. The control cells used copper(II) chloride, lithium chloride, and heavy water electrolyte. Experimental and control cells were supplied current, increasing from 0.1 to 100.0 mA over a period of 20 days. For test days 9 through 20, the standard configuration experimental cells exhibited significantly higher average neutron radiation than the controls at a 99% confidence level. Alternative configurations involving more increasing current over a shortened time scale, substitutions of water in place of heavy water or potassium chloride for lithium chloride, as well as inclusion of depleted uranium near the cell cathodes all resulted in inconclusive evidence for promoting neutron production.

neutron↗

Solid State Radiation Dosimeters for Space and Medical Applications

This report describes the development of two radiation monitors (RADMON's) for use in detecting total radiation dose and high-energy particles. These radiation detectors are chip-size devices fabricated in 1.2 micrometer CMOS and have flown in space on both experimental and commercial spacecraft. They have been used to characterize protons and electrons in the Earth's radiation belts, particles from the Sun, and protons used for medical therapy. Having proven useful in a variety of applications, the detector is now being readied for commercialization.

Buehler, Martin G.↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

Analysis of the Cyclotron Facility Calibration and Aircraft Results Obtained by LIULIN-3M Instrument

The LIULIN-3M instrument is a further development of the LIULIN dosimeter-radiometer, which has been used on the NffR space station in the 1988-1994 time period, The LIULIN-3M is designed for continuous monitoring of the radiation environment during the BION-12 satellite flight in 1999. A semiconductor detector with 1 mm thickness and 1 cm(exp 2) area is used in the instrument. Pulse high analysis technique is used for measurement of the energy losses in the detector. The final data sets from the instrument are the flux and the dose rate for the exposition time and 256 channels of LET spectra if a non-nal coincidence of the particles to the detector is considered. The LIULIN-3M instrument was calibrated by proton fluxes with different energies at the Indiana University Cyclotron Facility in June 1997 and was used for space radiation measurements during commercial aircraft flights. Obtained calibration and flight results are analyzed in the paper.

Dachev, T. P.↗

A comparison of depth dependence of dose and linear energy transfer spectra in aluminum and polyethylene

A set of four tissue-equivalent proportional counters (TEPCs), with their detector heads at the centers of 0 (bare), 3, 7 and 9-inch-diameter aluminum spheres, were flown on Shuttle flight STS-89. Five such detectors at the centers of polyethylene spheres were flown 1 year earlier on STS-81. The results of dose-depth dependence for the two materials convincingly show the merits of using material rich in hydrogen to decrease the radiation exposure to the crew. A comparison of the calculated galactic cosmic radiation (GCR) absorbed dose and dose-equivalent rates using the radiation transport code HZETRN with nuclear fragmentation model NUCFRG2 and the measured GCR absorbed dose rates and dose-equivalent rates shows that they agree within root mean square (rms) error of 12.5 and 8.2%, respectively. However, there are significant depth-dependent differences in the linear energy transfer (LET) spectra. A comparison for trapped protons using the proton transport code BRYNTRN and the AP-8 MIN trapped-proton model shows a systematic bias, with the model underpredicting dose and dose-equivalent rates. These results show the need for improvements in the radiation transport and/or fragmentation models.

manned↗

Summary of LET spectra and dose measurements on ten STS missions

A comparison of linear energy transfer (LET) spectra measurements made with plastic nuclear track detectors (PNTD's) from area passive dosimeters (APD's), was made for ten different STS missions under similar shielding. The results show that integral flux, dose rate and equivalent dose rate values follow a general increase with respect to increasing orbital inclination and altitude but that there are large variations from a simple relationship. This is to be expected since it has been shown that Shuttle attitude variations, combined with the anisotropic particle flux at the South Atlantic Anomaly (SAA), can result in differences of a factor of 2 in dose rate inside the Shuttle (Badhwar et al., 1995). Solar cycle and shielding differences also result in variations in radiation dose between STS missions. Spaceflight dosimeters from the STS missions are also being used in the development of a method for increasing LET spectra measurement accuracy by extending LET measurements to particle tracks of ranges 10-80 microns. Refinements in processing and measurement techniques for the flight PNTD's have yielded increased detection efficiencies for the short tracks when LET spectra determined by using the standard and refined methods were intercompared.

Source record↗