Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Control development and sizing analysis for a 5th generation district heating and cooling network using Modelica

5th generation district heating and cooling system (5GDHC) are a relatively new concept. They use a single district loop near ambient temperature to provide heating and cooling. This paper improves on the modelling and control of a 5GDHC system called the reservoir network. The study updates the sewage heat exchanger plant model to more realistically represent seasonal changes, uses refined pump models with variable efficiency, introduces a ground coupled district pipe model to consider the inertia of the district network and implements a new control strategy for geothermal storage and sewage heat exchanger. The new approach reduced operating costs, mainly due to pumping cost for storage, sewage heat exchanger plant and distribution pump, while increasing the overall robustness of the approach in different sizing conditions. Thanks to the new controller, the pumping consumption was reduced by 21% with respect to the original baseline. Furthermore, the new control makes the system take better advantage of design changes, when reducing borehole field size and increasing the sewage heat exchanger size, the pumping energy savings become 29% with respect to the original baseline. Lastly, borehole field temperature stability was analyzed through 40 years of simulation.

Zanetti, Ettore↗

Residential Home Repairs, Energy Efficiency, and Electrification in the Hill District of Pittsburgh [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies. This report summarizes the insights from stakeholder engagement with organizations that provide home repair services, weatherization, and residential energy efficiency in the Hill District as well as from a building analysis to characterize Hill District housing stock and the potential costs and benefits of energy efficiency and electrification measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Models for Electrical Distribution Network Planning and District-Scale Building Energy Use

The increase of greenhouse emissions caused by a rise in global energy consumption is pushing the scientific community to develop tools that address key environmental, techno-economic and social issues. One specific area of focus is to create tools that enable the design of high-performance energy districts, including grid-interactive efficient buildings and electrical distribution infrastructure. This paper outlines the approach of integrating a synthetic distribution network tool (RNM-US) with URBANopt™, a modular and customizable software development kit for thermal and electrical modelling of buildings and energy systems at a district scale. First, we describe the algorithms implemented to integrate RNM-US with URBANopt to automatically generate the distribution network for the district considered. Following, we present a case study for the potential uses of the RNM-US integrations with URBANopt, highlighting the capabilities for economic and technical analysis of the distribution network built in relation to the electricity needs of the modelled buildings.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic Simulation Results Using dGeo for EGS-Based District Heating in the Northeastern United States

This dataset presents the results of techno-economic simulations performed using the Distributed Geothermal Market Demand Model (dGeo) to evaluate the feasibility of Enhanced Geothermal Systems (EGS)-based district heating in the Northeastern United States. Developed by the National Renewable Energy Laboratory (NREL), dGeo is a geospatially resolved, bottom-up modeling framework designed to explore the deployment potential of geothermal distributed energy resources. The dataset, created as part of the Cornell EGS Ground-Truthing Project, provides census tract-level data that includes inputs and outputs such as thermal demand, road length, energy prices, geothermal system sizing, annual energy contributions from geothermal and natural gas peaking boilers, system capital costs (CAPEX), operation and maintenance costs (OPEX), and the levelized cost of heat (LCOH). Key simulation parameters include geothermal gradients, measured well depths, production temperatures, and district heating piping lengths based on S1400 neighborhood road lengths. The simulations assume a target bottom hole temperature of 80C and the development of new district heating networks in each census tract.

15 GEOTHERMAL ENERGY↗

2021 U.S. Geothermal Power Production and District Heating Market Report

This report, the 2021 U.S. Geothermal Power Production and District Heating Market Report, provides policymakers, regulators, developers, researchers, engineers, financiers, and other stakeholders with up-to-date information and data reflecting the 2019 geothermal power production and district heating markets, technologies, and trends in the United States. Analysis of the current state of the U.S. geothermal market and industry for both the power production and district heating sectors is presented, with consideration of developing power projects. Geothermal heat pumps, although a key technology in the wider use of geothermal resources, were considered outside the scope of this report. In addition, the report evaluates the impact of state and federal policy, presents current research on geothermal development, and describes future opportunities for the U.S. geothermal market and industry.

15 GEOTHERMAL ENERGY↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

A thermodynamic analysis of a novel bidirectional district heating and cooling network

In this study, we evaluate an ambient, bidirectional thermal network, which uses a single circuit for both district heating and cooling. When in net more cooling is needed than heating, the system circulates from a central plant in one direction. When more heating is needed, the system circulates in the opposite direction. A large benefit of this design is that buildings can recover waste heat from each other directly. We analyze the thermodynamic performance of the bidirectional system. Because the bidirectional system represents the state-of-the-art in design for district systems, its peak energy efficiency represents an upper bound on the thermal performance of any district heating and cooling system. However, because any network has mechanical and thermal distribution losses, we develop a diversity criterion to understand when the bidirectional system may be a more energy-efficient alternative to modern individual-building systems. We show that a simple model of a low-density, high-distribution loss network is more efficient than aggregated individual buildings if there is at least 1 unit of cooling energy per 5.7 units of simultaneous heating energy (or vice versa). We apply this criterion to reference building profiles in three cities to look for promising clusters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Quantifying the Mobility and Energy Benefits of Automated Mobility Districts Using Microscopic Traffic Simulation

Connected and automated vehicles (CAVs) are increasingly being discussed as the basis for shared mobility and on-demand services to replace privately owned vehicles. The rapid growth of transportation networking companies (TNCs) and their increasing investment in automated vehicle (AV) technologies attests to this. Combining the concepts of TNCs, with AV and on-demand transit services, the term 'automated mobility district' (AMD) describes a district-scale implementation of CAV technology to realize the full benefits of a shared, fully automated vehicle service within a confined region. This research effort provides a modeling architecture for AMDs along with a preliminary analysis to quantify the mobility and energy benefits of such districts. A customized open-source microscopic mobility simulation toolkit built on the simulation of urban mobility (SUMO) platform is implemented for AMD performance evaluation. Experimental scenarios are tested with different combinations of operational variables to provide insights on energy and mobility gains that can be realized in AMDs.

30 DIRECT ENERGY CONVERSION↗

Community Geothermal: Energy, Cost, and Carbon Modeling for District Design - Ann Arbor, MI

This data includes results on an analysis of existing and projected energy, cost, and carbon for the City of Ann Arbor - District Geothermal Design and Deployment to Equitably Decarbonize Low Income Neighborhoods in Ann Arbor project. The scope of the project includes designing and implementing a geothermal district heating and cooling system that reduces thermal heating and cooling load by 75% and greenhouse gas emissions by 40% in the project area (262 households, 6 commercial buildings). The existing neighborhood was modeled using Design Builder, an EnergyPlus software, to understand the current energy load. The energy model was then flipped to reflect the designed district geothermal heating and cooling system to project the effect on energy, carbon, and cost. This dataset includes the analysis files utilized and created for this study. There are 3 categories of data: 1) existing/benchmarking, 2) energy modeling, and 3) post processed calculations. This follows the methodology and process of the project team, which is fully explained in file 00_Technical Economic Environmental Assessment. All uses of data are referenced throughout this assessment to their respective files included below.

15 GEOTHERMAL ENERGY↗

Synopsis of NREL's Automated Mobility District (AMD) Research Program and Associated Publications

An automated mobility district (AMD) envisions a system of integrated mobility options that serves major activity centers such as campuses, central business districts, and large medical facilities. The National Renewable Energy Laboratory (NREL) has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings. This document provides a synopsis of findings revealed over the last three phases of work, which have yielded insights into the creation and management of AMDs anticipated to use automated vehicle (AV) technology over the next decade. Phase I and Phase II tracked the deployment and lessons learned from 10 early-stage demonstrations of automated shuttle deployments, and their associated insights into the challenges for automated driving systems to achieve safe operations within district-scale deployments. Phase III began in-depth investigations of critical subsystem components, as automation, electrification, and on-demand service continue to converge within initial AMD operations. These directed studies focus on elements of electrification, curbfront/station management, the role of infrastructure sensing, and overall integration of AMD safety management in central, simultaneous coordination of multiple AMD fleets. Future research in AMDs includes systems engineering methodology (more frequently referred to as "digital twins") for planning, design, testing, and ongoing operation of AMDs; location (or co-location) of management functions; and human supervision and passenger communications for safety and security in unattended vehicles. The synopsis references the foundational research products (papers and presentations) that have been published through conference proceedings, journal articles, and NREL reports.

33 ADVANCED PROPULSION SYSTEMS↗

U.S. Department of Energy Solar District Cup Collegiate Design Competition

The Solar District Cup is a multidisciplinary collegiate competition that challenges student teams to design and model standalone solar and solar-plus-storage systems for multiple buildings on a local electrical distribution network, such as a college campus, across a development, or in a district. Students learn cross-cutting skills that prepare them to become part of the next generation of the distributed energy workforce. Student teams act as renewable energy developers proposing to solar and solar-plus-storage system requests. Students, faculty, and prospective employers can benefit from knowing about this program and what students learn--either immediately as participants, mentors, or judges, or as potential employers of Solar District Cup alumni. RE+ is also one of our competition partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗