Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “district energy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optimal Co-Design of Integrated Thermal-Electrical Networks and Control Systems for Grid-interactive Efficient District (GED) Energy Systems

This project advances a unified, open-source framework for the optimal co-design of thermal, electrical, and control systems in grid-interactive efficient districts (GEDs). As communities integrate growing levels of distributed energy resources, traditional approaches that model thermal and electrical networks independently lead to reduced efficiency, limited flexibility, and missed opportunities for coordinated operation. To address these challenges, the research team developed a comprehensive suite of physics-based models, control algorithms, and software tools that enable holistic simulation, optimization, and demonstration of district-scale energy systems.

14 SOLAR ENERGY↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

Pilgrim Hot Springs: GEOPHIRES Inputs and Outputs for Direct-Use Geothermal District Heating and Cooling

This dataset includes files for a techno-economic analysis conducted using the GEOPHIRES simulator to examine the feasibility of expanding a larger district heating site in a remote location: Pilgrim Hot Springs, Alaska. Files included here are GEOPHIRES inputs and outputs for five different scenarios with varying demand, cycle, and system design characteristics to analyze. Also included is the link to the GEOPHIRES GitHub, as well as a link to the dataset that contains the energy modelling used to determine the heating demand for the district. For a list of the differences between scenarios, see the included "Input Overview.txt" file. Fields included in the input files are: subsurface technical parameters, surface technical parameters, financial parameters, capital and O&M parameters, as well as simulation parameters. The output files are case reports that summarize all equipment, reservoir characteristics, costs, and heating profiles.

15 GEOTHERMAL ENERGY↗

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven Quasi-static Surrogate Models for Nuclear-powered Integrated Energy Systems

The integration of nuclear power into energy systems presents a promising avenue to address the growing global energy demands while minimizing greenhouse gas emissions. In this paper, we introduce a data-driven quasi-static surrogate model for nuclear-powered Integrated Energy Systems (IES) that comprises various components, including a small modular reactor (SMR), steam manifold, balance of plant (BOP), high-temperature steam electrolysis (HTSE), and district heating (DH) system. Traditional physics-based models for these components often entail significant computational resource and time consumption, necessitating the development of efficient surrogate models. The development of a complete surrogate model for the IES involves the creation of individual surrogate models for each component, leveraging machine learning techniques and simulated data. These isolated surrogate models are subsequently integrated, enabling a holistic view of the IES and reducing the computational burden associated with detailed physics-based simulations. This paper outlines the development process, validation, and the performance evaluation of the surrogate models. The exceptional performance, with low root-mean-squared errors and R-squared scores of at least 99.8% across all individual surrogate models, underscores their accuracy and practical applicability. These results demonstrate the potential of these models to expedite the analysis of nuclear-powered IES, offering insights that can shape future research and development efforts.

08 HYDROGEN↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

Industry case studies: Finance

This article, the third in a series on the U.S. Department of Energy and IDEA collaboration, focuses on financial strategies used by institutions to support district energy system modernization and decarbonization. It highlights how effective funding models, long-term cost analysis, and leadership support are critical to implementing large-scale infrastructure upgrades. The case studies show different approaches to financing. Ball State University demonstrates how life-cycle cost analysis and phased funding—supported by state funding, bonds, and grants—enabled a transition to geothermal energy. Penn State’s Hershey Medical Center emphasizes the importance of financial leadership, shifting from reactive budgeting to data-driven, proactive investment in infrastructure. The University of Washington highlights how comprehensive data collection and analytics can justify investments and even create self-sustaining funding mechanisms like green revolving funds. Overall, the article shows that combining strong financial planning, data-driven decision-making, and innovative funding approaches is essential for advancing sustainable district energy systems while managing high upfront costs.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Techno-Economic Simulation Results Using dGeo for EGS-Based District Heating in the Northeastern United States

This dataset presents the results of techno-economic simulations performed using the Distributed Geothermal Market Demand Model (dGeo) to evaluate the feasibility of Enhanced Geothermal Systems (EGS)-based district heating in the Northeastern United States. Developed by the National Renewable Energy Laboratory (NREL), dGeo is a geospatially resolved, bottom-up modeling framework designed to explore the deployment potential of geothermal distributed energy resources. The dataset, created as part of the Cornell EGS Ground-Truthing Project, provides census tract-level data that includes inputs and outputs such as thermal demand, road length, energy prices, geothermal system sizing, annual energy contributions from geothermal and natural gas peaking boilers, system capital costs (CAPEX), operation and maintenance costs (OPEX), and the levelized cost of heat (LCOH). Key simulation parameters include geothermal gradients, measured well depths, production temperatures, and district heating piping lengths based on S1400 neighborhood road lengths. The simulations assume a target bottom hole temperature of 80C and the development of new district heating networks in each census tract.

15 GEOTHERMAL ENERGY↗

Enhancing flexibility for climate change using seasonal energy storage (aquifer thermal energy storage) in distributed energy systems

Long-term energy storage is expected to play a vital role in the deep decarbonization of building energy sectors, while enhancing the flexibility of buildings to withstand future climate variations. However, it is challenging to design distributed multi-energy systems (DMES) while taking into account the uncertainties introduced by climate change, since stochastic optimization of such systems is difficult. The present study introduces a stochastic optimization model to address this bottleneck, taking into account DMES including aquifer thermal energy storage (ATES) as the long-term thermal storage. For the first time, a novel optimization algorithm links ATES with the DMES optimization model with the support of a simplified geotechnical model. Subsequently, a case study was conducted, focusing on a residential district in Chicago where the impact of future climate condition, energy demand, and solar and wind energy potentials were evaluated using Weather Research and Forecasting (WRF) data (up to 2080) and the EnergyPlus model. The study revealed that ATES is an attractive way to improve the renewable energy penetration level and minimize the dependence on fossil fuels with reasonable support from the grid to assist the fluctuations in both demand and generation. Furthermore, ATES notably reduces fuel consumption and dependence while greatly enhancing the flexibility of the energy system to withstand fluctuations in demand and renewable energy generation brought by future climate variations. These qualities will make ATES an important part of distributed energy systems, even though it is not currently the lowest cost alternative due to lack of technology maturity. Furthermore, the design platform introduced in the present study can be used to design DMES enhancing flexibility to accommodate future climate variations.

25 ENERGY STORAGE↗

GCAM-USA v5.3_water_dispatch: integrated modeling of subnational US energy, water, and land systems within a global framework

Abstract. This paper describes GCAM-USA v5.3_water_dispatch, an open-source model that represents key interactions across economic, energy, water, and land systems in a consistent global framework with subnational detail in the United States. GCAM-USA divides the world into 31 geopolitical regions outside the United States (US) and represents the US economy and energy systems in 51 state-level regions (50 states plus the District of Columbia). The model also includes 235 water basins and 384 land use regions, and 23 of each fall at least partially within the United States. GCAM-USA offers a level of process and temporal resolution rare for models of its class and scope, including detailed subnational representation of US water demands and supplies and sub-annual operations (day and night for each month) in the US electric power sector. GCAM-USA can be used to explore how changes in socioeconomic drivers, technological progress, or policy impact demands for (and production of) energy, water, and crops at a subnational level in the United States while maintaining consistency with broader national and international conditions. This paper describes GCAM-USA's structure, inputs, and outputs, with emphasis on new model features. Four illustrative scenarios encompassing varying socioeconomic and energy system futures are used to explore subnational changes in energy, water, and land use outcomes. We conclude with information about how public users can access the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Avista CEF2 Shared Energy Economy: Modeling and Simulation

This research project supported Avista’s Shared Energy Economy (SEE) Project in Spokane’s University District (UDistrict), as funded by the WA Department of Commerce Clean Energy Fund (CEF) Phase 2. The SEE project comprises a microgrid with two campus buildings, two solar photovoltaic generators, and two batteries. The microgrid can operate grid-connected or off-grid. This research project included modeling the buildings and other microgrid components, simulating a transactive energy system, and supporting Avista’s testing of different use cases for the WA Department of Commerce. The main research finding is that buildings can be modeled successfully in a data-driven approach.

14 SOLAR ENERGY↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

U.S. Department of Energy Solar District Cup Collegiate Design Competition

The Solar District Cup is a multidisciplinary collegiate competition that challenges student teams to design and model standalone solar and solar-plus-storage systems for multiple buildings on a local electrical distribution network, such as a college campus, across a development, or in a district. Students learn cross-cutting skills that prepare them to become part of the next generation of the distributed energy workforce. Student teams act as renewable energy developers proposing to solar and solar-plus-storage system requests. Students, faculty, and prospective employers can benefit from knowing about this program and what students learn--either immediately as participants, mentors, or judges, or as potential employers of Solar District Cup alumni. RE+ is also one of our competition partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A fast and accurate modeling approach for water and steam thermodynamics with practical applications in district heating system simulation

In U.S. district heating (DH) systems, steam is the most common heat transport medium. Industry demand for new advanced modeling capabilities of complete steam DH systems is increasing; however, the existing models for water/steam thermodynamics are too slow for large system simulations because of computationally expensive algebraic loops that require the solution to nonlinear systems of equations. For practical applications, this work presents a novel split-medium approach that implements numerically efficient liquid water models alongside various water/steam models, breaking costly algebraic loops by decoupling mass and energy balance equations. New component models for steam DH systems are also presented. We implemented the models in the equation based Modelica language and evaluated accuracy and computing speed across multiple scales: from fundamental thermodynamic properties to complete districts featuring 10 to 200 buildings. Compared to district models with the IF97 water/steam model and equipment models from the Modelica Standard Library, the new implementation improves the scaling rate for large districts from cubic to quadratic with negligible compromise to accuracy. Additionally, for an annual simulation with 180 buildings, this translates to a computing time reduction from 33 to 1-1.5 h. These results are critically important for industry practitioners to simulate steam DH systems at large scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗