Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing the PR100 Study: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phaseout of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040 as established in Act 17. [1] To meet these goals and support widespread end-use electrification, the territory must explore how renewable energy and other generation technologies can be developed with energy storage, distributed generation, distribution control, electric vehicles, and energy efficient and responsive loads in each of Puerto Rico's cities and communities. To support Puerto Rico in reaching its renewable energy goals; help ensure energy system resilience against future extreme weather events; improve energy justice; and provide inputs to LUMA Energy's walk, jog, and run approach in its coordinated planning roadmap, the U.S. Department of Energy, National Renewable Energy Laboratory, Argonne National Laboratory, Lawrence Berkeley National Laboratory, Oak Ridge National Laboratory, Pacific Northwest National Laboratory and Sandia National Laboratories propose to evaluate 100% renewable energy pathways through an integrated analysis process. This talk will present steps in designing a two-year study entitled Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy (PR100). [1] U.S. Energy Information Administration (EIA). 2020. Puerto Rico Territory Energy Profile.

100% renewable energy↗

Learning Sequential Distribution System Restoration via Graph-Reinforcement Learning

We report a distribution service restoration algorithm as a fundamental resilient paradigm for system operators provides an optimally coordinated, resilient solution to enhance the restoration performance. The restoration problem is formulated to coordinate distribution generators and controllable switches optimally. A model-based control scheme is usually designed to solve this problem, relying on a precise model and resulting in low scalability. To tackle these limitations, this work proposes a graph-reinforcement learning framework for the restoration problem. We link the power system topology with a graph convolutional network, which captures the complex mechanism of network restoration in power networks and understands the mutual interactions among controllable devices. Latent features over graphical power networks produced by graph convolutional layers are exploited to learn the control policy for network restoration using deep reinforcement learning. The solution scalability is guaranteed by modeling distributed generators as agents in a multi-agent environment and a proper pre-training paradigm. Comparative studies on IEEE 123-node and 8500-node test systems demonstrate the performance of the proposed solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Least-cost Optimal Distribution Grid Expansion (LODGE): Utility Pilots

The Least-cost Optimal Distribution Grid Expansion (LODGE) model provides the optimal portfolio of distribution system upgrades—e.g., voltage regulators, feeder reconductoring, transformer upgrades and non-wires alternatives (NWA), such as strategic siting of storage and distributed generation—to interconnect distributed energy resources (DERs) and enable load growth. It can be used to assess grid infrastructure costs and explore policy and regulatory solutions for distribution planning and DER valuation.In 2025, Berkeley Lab conducted three pilot analyses to validate LODGE results with empirical utility data before the model’s first release in 2026. The pilots, done with utilities in Washington, Colorado, and New Mexico, provide examples that illustrate how the model works, what it can do, and the value of the analysis.

Heleno, Miguel↗

Optimal Power Dispatch of DGs in Radial and Mesh AC Grids: A Hybrid Solution Methodology between the Salps Swarm Algorithm and Successive Approximation Power Flow Method

In this paper, we address the problem of the optimal power dispatch of Distributed Generators (DGs) in Alternating Current (AC) networks, better known as the Optimal Power Flow (OPF) problem. We used, as the objective function, the minimization of power losses (P loss ) associated with energy transport, which are subject to the set of constraints that compose AC networks in an environment of distributed generation. To validate the effectiveness of the proposed methodology in solving the OPF problem in any network topology, we employed one 10-node mesh test system and three radial text systems: 10, 33, and 69 nodes. In each test system, DGs were allowed to inject 20%, 40%, and 60% of the power supplied by the slack generator in the base case. To solve the OPF problem, we used a master–slave methodology that integrates the optimization method Salps Swarm Algorithm (SSA) and the load flow technique based on the Successive Approximation (SA) method. Moreover, for comparison purposes, we employed some of the algorithms reported in the specialized literature to solve the OPF problem (the continuous genetic algorithm, the particle swarm optimization algorithm, the black hole algorithm, the antlion optimization algorithm, and the Multi-Verse Optimizer algorithm), which were selected because of their excellent results in solving such problems. The results obtained by the proposed solution methodology demonstrate its superiority and convergence capacity in terms of minimization of P loss in both radial and mesh systems. It provided the best reduction in minimum P loss in short processing times and showed excellent repeatability in each test system and scenario under analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Curtailment Risk of Non-Firm Utility-Scale Solar Photovoltaic Plants under a Novel Last-In First-Out Principle of Access Interconnection Agreement

With the increasing share of distributed energy resources on the electric grid, utility companies are facing significant decisions about infrastructure upgrades. An alternative to extensive and capital-intensive upgrades is to offer non-firm interconnection opportunities to distributed generators, via a coordinated operation of utility scale resources. This paper introduces a novel flexible interconnection option based on the last-in, first-out principles of access aimed at minimizing the unnecessary non-firm generation energy curtailment by balancing access rights and contribution to thermal overloads. Although we focus on solar photovoltaic (PV) plants in this work, the introduced flexible interconnection option applies to any distributed generation technology. The curtailment risk of individual non-firm PV units is evaluated across a range of PV penetration levels in a yearlong quasi-static time-series simulation on a real-world feeder. The results show the importance of the size of the curtailment zone in the curtailment risk distribution among flexible generation units as well as that of the “access right” defined by the order in which PV units connect to the grid. Case study results reveal that, with a proper selection of curtailment radius, utilities can reduce the total curtailment of flexible PV resources by up to more than 45%. Findings show that non-firm PV generators can effectively avoid all thermal limit-related upgrade costs.

14 SOLAR ENERGY↗

Hosting Capacity Improvement Method Using MV–MV Solid-State-Transformer

As a large number of distributed generations are connected to the distribution system, research on the hosting capacity is actively being conducted. In particular, various methods, such as smart inverter functionality, co-located energy storage systems (ESS), and the use of on-load tap changers (OLTC), have been proposed to improve the hosting capacity. In this paper, a method to improve the hosting capacity by utilizing a solid-state transformer (SST) and its unique control capability is proposed. Lastly, the proposed method is verified in the distribution system of the Republic of Korea using the OpenDSS program.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post-Disturbance Dynamic Distribution System Restoration with DGs and Mobile Resources

Distributed generations (DGs) can act as emergency power supplies when distribution systems suffer from outages. However, the generation capabilities of DGs are generally limited by a number of factors including weather conditions, fuel limitations, etc. In this context, mobile resources that are able to reallocate resources to desired locations are regarded as important complements to conventional fixed DGs in assisting distribution system restoration. In this paper, a distribution system restoration model with DGs and mobile resources is proposed. Firstly, the dispatch and allocation of mobile resources are modeled with respect to the characteristics of the traffic network. Then the developed mobile resource models are integrated into the distribution system restoration model to co-optimize the scheduling of DGs and mobile resources. Uncertainty factors are managed by a model predictive control approach so that system operators can dynamically adjust the restoration strategy with the up-to-date information. The effectiveness of the proposed method is validated through an IEEE 13-bus test system.

distributed generations (DGs)↗

Developing Synthetic Distribution Models Using Open-Source Data Sets

The deployment of distributed generation resources at scale with the distribution side of the power system network over the last two decades has spurred a lot of research interest in distribution networks. Given, the sensitive nature of power system data sets, utilities are still reluctant to open-source distribution networks. Although some open-source data sets are available, they may not cover the region of interest. In this paper, we introduce the Synthetic dIstribution Network Generator (SING), new software that allows users to develop synthetic distribution models, using open-source data sets, in any region of interest within the continental US.

data set↗

Computational framework for behind-the-meter DER techno-economic modeling and optimization: REopt Lite

The energy system is undergoing a major transformation with the global emphasis on decarbonization. Distributed generation is projected to play a significant role in the new energy system, and energy models are informing how distributed generation can be integrated reliably and economically. In this work, we present an end-to-end computational framework for distributed energy resource (DER) modeling, REopt Lite™, which captures the interface of technology, economics, and policy in the energy modeling process. We describe the problem space, the building blocks of the model, the scaling capabilities of the design, the optimization formulation, and the extensibility of the model. We present a framework for accelerating the techno-economic analysis of behind-the-meter distributed energy resources to enable rapid planning and decision-making, thereby enabling greater renewable energy deployment. This computation framework is open-sourced to facilitate transparency, flexibility, and wider collaboration opportunities within the worldwide energy modeling community.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DC electric field generation and distribution in magnetized plasmas

Very large DC and AC electric fields cannot be sustained between conducting electrodes because of volume gas breakdown and/or surface field emission. However, very large potential fields are now routinely generated in plasma structures, such as laser generated wake in unmagnetized plasmas. In magnetized plasmas, large DC fields can also be sustained and controlled perpendicular to the magnetic field, but the metallic end plates limiting the plasma, terminating the magnetic field lines, and usually providing the voltage drop feed between the field lines impose severe restrictions on the maximum field. However, it is shown that very large radial DC voltage drops can be sustained by injecting waves of predetermined frequencies and wave vectors, traveling along the azimuthal direction of an axially magnetized plasma cylinder, or by injecting fast neutral particles beams along this azimuthal direction. The large conductivity along the magnetic field lines and the small conductivity between the field lines then distribute this voltage drop. Furthermore, the global power balance and control parameters of wave and beam generated large DC electric fields in magnetized plasmas are identified, described, and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed Online Voltage Control in Distribution Network: A Two-Stage Real-Time Implementation

The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system.

Distributed generation↗

STOCHASTIC OPTIMAL POWER FLOW FOR REAL-TIME MANAGEMENT OF DISTRIBUTED RENEWABLE GENERATION AND DEMAND RESPONSE (Final Report)

To meet the grand challenge of a sustainable energy future, there has been a surge of interest in renewable energy. Today, the uncertainty associated with renewable resources is handled by using operating reserves. The high penetration of renewable resources, however, introduces difficult-to-control dynamics and challenges for power system operation. Decision support tools are necessary at the bulk system operational level to recognize and efficiently utilize renewable resources and distributed demand response products in concert with traditional grid resources. It is envisaged that responsive load can potentially have very significant cost advantages over either spinning or non-spinning ramping reserve. Critical decisions are made during hour(s)-ahead and real-time power system operation regarding the commitment and dispatch of generators to ensure power delivery is both reliable and economic. These decisions are typically made by a security constrained optimal flow, which determines future generator commitments, dispatches, and ensures adequate reserves are available in the event of a contingency (unexpected outage) or if future system conditions deviate from forecasts. However, security has been always based on a pre-specified subset of contingency constraints whose enforcement does not guarantee security under all possible future possibilities while also giving little or no weight to the likelihood of each contingent event or the severity of its consequences. Existing tools, which are based exclusively on deterministic optimization models, do not yield optimal operational decisions to address these new challenges, in terms of both reliability and cost-effectiveness. This project has focused on developing a stochastic optimal power flow (SOPF) framework, which integrates renewable resource uncertainty, load uncertainty, distributed storage (DS), demand response (DR) products, in a holistic manner to address the uncertainty associated with ever-increasing renewable resources, along with the inclusion of distributed demand response products in future power systems. A proof-of-concept problem was created using the Pennsylvania-Jersey-Maryland (PJM) power system network. Synthetic wind generation was added to the system to simulate 50% wind penetration. A 1-hour test of SOPF operation indicated more than 6% operational cost savings. The project continued by adding the Midwestern Independent System Operator (MISO) as a partner, with focus shifting from SOPF to Stochastic Look-Ahead Unit Commitment (SLAC). Unlike PJM, MISO is faced with significant renewable energy resources within its footprint and is challenged with substantial uncertainty in its operations. The SLAC distinguishes itself from existing tools that operators use. At best, today’s tools solve two to three cases independently, where one or two system parameters, such as forecasted load level (e.g., a low, base, and high forecast), are varied and the resulting scenarios are analyzed independently. The stochastic-based optimization of SLAC leverages statistical information from an ensemble of potential operational scenarios and their respective likelihood. The SLAC output can be translated into valuable information to the operator such as suggested commitments, optimal scheduling and dispatch of resources, reserve requirements at both locational and zonal resolutions, ramping availability and requirements, availability of demand response including operational guidance concerning the near-term and real-time coordination between distributed energy resources, and utilization of distributed storage resources. The developed SOPF/SLAC tool, a stand-alone tool compatible with existing EMSs, will provide system operators with unprecedented visibility, flexibility and predictability to these resources and operational guidance concerning the real-time coordination between DERs and DR/DS products. The game changing and practical impact of this disruptive technology will be dramatic and will usher in a new era in the electric power industry, wherein green energy concepts are fully embraced, and electric power costs are lowered throughout the nation.

42 ENGINEERING↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Integrated transient modeling of gas turbine and sCO2 power cycle for exhaust heat recovery application

For distributed generation installations, the transient response of the power generation system is critical to meet power quality (voltage and frequency) requirements. Transient models for gas turbine and supercritical carbon dioxide (sCO2) power cycle were integrated for an exhaust heat recovery bottoming cycle system for a distributed generation application. The transient model for the SGT-750 Siemens gas turbine was a ‘black-box’ functional mockup interface (FMI) model developed by Siemens Industrial Turbomachinery in $Finsp\mathring{a}ng$, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8 °C.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100)

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phaseout of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040 as established in Puerto Rico Energy Public Policy Act (Act 17). To meet these goals and support widespread end-use electrification, Puerto Rico is exploring renewable energy and innovative technologies for energy storage, distributed generation, distribution control, electric vehicles, and energy efficient and responsive loads that can be deployed in each of Puerto Rico's cities and communities. Launched in February 2022, a two-year study entitled Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy (PR100) will perform a comprehensive analysis of stakeholder-driven pathways to Puerto Rico's clean energy future. This fact sheet describes the five activities this robust and objective energy analysis entails.

ENERGY PLANNING, POLICY, AND ECONOMY↗

The Distribution of U.S. Electric Utility Revenue Decoupling Rate Impacts from 2005 to 2017

Investments in energy efficiency and distributed generation reduce electric utility retail sales. Since electric utilities have historically collected a large portion of revenues from volumetric energy rates (¢/kWh), such reductions in sales can impact the utility’s ability to sufficiently recover non-production costs. Regulatory mechanisms that “decouple” utility revenues from sales were implemented to help make the utility indifferent to energy efficiency and distributed generation by ensuring the utility is able to collect an allowed level of revenue each year regardless of its sales. However, noticeable and consistent surcharges over time may create the perception of an incorrectly designed or implemented decoupling mechanism. To date, there are limited quantitative analyses of the rate adjustments due to decoupling mechanisms implemented among U.S. electric utilities (see Morgan, 2013). Given the recent rapid increase in distributed energy resource (DER) adoption in some states and utility service territories, consumers may be facing more prevalent and ongoing decoupling surcharges. This, in turn, may undermine stakeholder support for implementation of decoupling mechanisms and the associated utility support for energy efficiency and DERs. To determine the size of retail rate adjustments associated with decoupling mechanisms and whether they have a tendency towards bill surcharges or credits, we analyzed a large dataset of historical annual decoupling rate adjustments for 21 electric utilities in 11 states between 2005 and 2017. We found that decoupling mechanisms adjusted rates, both up and down, between rate cases, and the majority of those adjustments (54 percent) are small (within a range of -1 to 1 percent). However, we also found that 64 percent of the rate adjustment observations in our sample showed a positive rate adjustment. Importantly, once a surcharge is applied there is an 86 percent chance that there will be a surcharge in the next year as well. While our analysis did not seek to understand the root causes for such results, some possible factors include the accuracy of revenue requirement forecasts, emerging structural changes in customer use and production of energy, misaligned financial motivation, and other factors that influence sales (e.g., economic recession).