Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Deep probabilistic direction prediction in 3D with applications to directional dark matter detectors

Abstract We present the first method to probabilistically predict 3D direction in a deep neural network model. The probabilistic predictions are modeled as a heteroscedastic von Mises-Fisher distribution on the sphere S 2 , giving a simple way to quantify aleatoric uncertainty. This approach generalizes the cosine distance loss which is a special case of our loss function when the uncertainty is assumed to be uniform across samples. We develop approximations required to make the likelihood function and gradient calculations stable. The method is applied to the task of predicting the 3D directions of electrons, the most complex signal in a class of experimental particle physics detectors designed to demonstrate the particle nature of dark matter and study solar neutrinos. Using simulated Monte Carlo data, the initial direction of recoiling electrons is inferred from their tortuous trajectories, as captured by the 3D detectors. For 40 keV electrons in a 70% He 30% CO 2 gas mixture at STP, the new approach achieves a mean cosine distance of 0.104 (26 ∘ ) compared to 0.556 (64 ∘ ) achieved by a non-machine learning algorithm. We show that the model is well-calibrated and accuracy can be increased further by removing samples with high predicted uncertainty. This advancement in probabilistic 3D directional learning could increase the sensitivity of directional dark matter detectors.

Computer Science↗

Multiplexed Readout of Thermal Bolometers with Superconducting Transition Edge Thermometers

History shows that in astronomy, more is better. In the near future, direct detector arrays for the far-infrared and submillimeter will contain hundreds to thousands of elements. A multiplexed readout is necessary for practical implementation of such arrays, and has been developed using SQUIDs. The technology permits a 32 x 32 array of bolometers to be read out using approximately 100 wires rather than the >2000 needed with direct wiring. These bolometer arrays are made by micromachining techniques, using superconducting transition edge sensors as the thermistors. We describe the development of this multiplexed superconducting bolometer array architecture as a step toward bringing about the first astronomically useful arrays of this design. This technology will be used in the Submillimeter and Far Infrared Experiment (SAFIRE) instrument on Stratospheric Observatory for Infrared Astronomy (SOFIA), and is a candidate for a wide variety of other spectroscopic and photometric instruments.

Benford, Dominic J.↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗

Faraday Rotation Measurements in High-Energy-Density Plasmas Using Shaped Laser Beams

Magnetic fields play an important role in plasma dynamics, yet it is a quantity difficult to measure accurately with physical probes, whose presence disturbs the very field they measure. The Faraday rotation of a polarized beam of light provides a mechanism to measure the magnetic field without disturbing the dynamics, and has been used with great success in astrophysics and high energy density plasma science, where physical probes cannot be used. Furthermore, the rotation is typically small, which degrades the accuracy of the measurement. Since polarization cannot be measured directly, detectors rely on a polarizer to measure a small change in beam intensity instead. In this work, we show how beam shaping can improve Faraday rotation measurements using an optical derivative setup. Since the rotation measurement is now strictly proportional to the beam shape and intensity, the system allows to improve the measurement accuracy simply by increasing the laser beam power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Searching for the Nature of Dark Matter and Dark Energy

DE-SC0019474 supported a multi-pronged approach to understanding dark matter and dark energy. This included probes of dark matter at collider experiments, neutrino detectors, direct detection experiments, and N-body simulations of dark matter halos. This work helps guide our understanding of dark matter, particles associated with a dark matter sector, and how to use current and future experiments to search for direct evidence of dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pandora-based muon neutrino disappearance search in the SBN program with 1muonNp quasi-elastic like channel

The Short-Baseline Neutrino (SBN) program at Fermilab aims to perform a definitive search for light sterile neutrinos using multiple liquid argon time projection chamber detectors. We present the status of an analysis of muon neutrino charged-current interactions in two SBN detectors (SBND and ICARUS), selecting fully contained events with one muon and at least one proton in the final state, inspired by the recent ICARUS standalone results. This topology-driven selection reduces dependence on neutrino interaction cross-section modeling while preserving high statistics and good neutrino energy resolution, enabled by robust reconstruction and particle identification. Fully contained events enable precise kinematic reconstruction and support relative measurements between detectors, directly addressing the core goals of the SBN program. A detailed evaluation of systematic uncertainties is currently underway, with the objective of reducing the dominant systematics to the percent level. The current status of this analysis, with a particular focus on the event selection performance, will be presented in this poster.

Artero Pons, Maria [Padua U.; INFN, Padua]↗

Pulse-height analyzer with digital readout

Feedback-controlled pulse-amplitude integrator and amplifier is used as an analog-to-digital converter that converts event-liberated charges, emanating from a nuclear-particle detector, directly to numbers rather than to analog-dependent voltages.

Goldsworthy, W. W.↗

Micrometeorites and solar flare particles in and out of the ecliptic

Using crystals grown into vugs from oriented lunar rocks as directional detectors of cosmic dust particles and solar flare nuclei, I have measured the angular distribution of the flux of micrometeoroids of mass 30 attograms to 80 femtograms. Hypervelocity impact craters of diameter 500 A to 10 microns and tracks from solar flare nuclei of energy 100 keV/amu to 20 MeV/amu were observed in crystals from rock 71055 facing lunar south and in crystals from rock 74255 facing lunar east. I have found that dust grains both in ecliptic orbits and in orbits inclined to the ecliptic have virtually identical mass-frequency distributions and similar shapes. I have evaluated the micrometeoroid fluxes after determining the exposure ages of the individual vug crystals by measuring the solar flare track density gradients in each crystal. The flux of particles of mass greater than 4 femtograms confined to the ecliptic is in good agreement with satellite measurements, suggesting that the micrometeoroid flux has been relatively constant over the past 35,000 yr. The flux of particles producing microcraters on a lunar surface facing south is lower than the ecliptic flux by a factor of about 7.

Hutcheon, I. D.↗

Clear air turbulence forecasting techniques

A method to improve clear air turbulence (CAT) forecasting by more effectively using the currently operational rawinsonde (RW) system is discussed. The method is called the Diagnostic Richardson Number Tendency (DRT) technique. The technique does not attempt to use the RW as a direct detector of the turbulent motion or even of the CAT mechanism structure but rather senses the synoptic scale centers of action which provide the energy to the CAT mechanism at the mesoscale level. The DRT algorithm is deterministic rather than statistical in nature, using the hydrodynamic equations (equations of motion) relevant to the synoptic scale. However, interpretation, by necessity, is probabilistic. What is most important with respect to its operational implementation is that this method uses the same input data as currently used by the operational National Meteorological Center prognostic models.

Keller, J. L.↗

A directional gamma-ray telescope using coded aperture techniques

A directional detector for gamma-ray astronomy has been developed to image sources in the energy range 0.1 to 5 MeV. An array of 35 gain stabilized bismuth germanate detectors, together with a coded aperture mask based on a uniformly redundant array allows imaging in 4 deg square sky bins over a 16 x 24 deg field-of-view. The position of a strong point source, such as the Crab Nebula, can be determined to within not more than about 1 deg. A complementary 'anti-mask' greatly reduces systematic effects arising from nonuniform background rates amongst the detectors. The telescope has an effective area of 190 sq cm and an energy resolution of 19.5 percent FWHM at 662 keV. Results of laboratory tests of the imaging system, including the ability to image multiple sources, uniformity of response over the field-of-view, and the effect of the 'anti-mask', are in good agreement with computer simulations. Features of the flight detector system are described and results of laboratory tests and computer simulations are reviewed. A balloon flight of the telescope is planned for the fall of 1982.

Mcconnell, M. L.↗

SSTAC/ARTS review of the draft Integrated Technology Plan (ITP). Volume 8: Aerothermodynamics Automation and Robotics (A/R) systems sensors, high-temperature superconductivity

Viewgraphs of briefings presented at the SSTAC/ARTS review of the draft Integrated Technology Plan (ITP) on aerothermodynamics, automation and robotics systems, sensors, and high-temperature superconductivity are included. Topics covered include: aerothermodynamics; aerobraking; aeroassist flight experiment; entry technology for probes and penetrators; automation and robotics; artificial intelligence; NASA telerobotics program; planetary rover program; science sensor technology; direct detector; submillimeter sensors; laser sensors; passive microwave sensing; active microwave sensing; sensor electronics; sensor optics; coolers and cryogenics; and high temperature superconductivity.

Source record↗

Onset of dispersion in Nb microstrip transmission lines at submillimeter wave frequencies

We have measured the dispersion in phase velocity of a Nb-SiO(x)-Nb microstrip transmission line resonator over a frequency range from 50 GHz to 800 GHz. A submicron Nb/Al-AlO(x)/Nb Josephson junction was used as a voltage-controlled oscillator to excite the high order modes in the resonator. The same junction is used as a direct detector resulting in a series of step-like structures in the DC current-voltage characteristic at the position of each mode frequency. The transmission line is dispersionless up to about 500 GHz where the phase velocity begins to decrease. This is well below the gap frequency f(sub g) approx. equals 700 GHz. Results agree qualitatively with the expected theoretical behavior near f(sub g). This onset of dispersion and loss in Nb transmission lines will have a significant impact on the design of submillimeter wave RF circuits.

Javadi, H. H. S.↗

Recent advances in superconducting-mixer simulations

Over the last few years, considerable progress have been made in the development of techniques for fabricating high-quality superconducting circuits, and this success, together with major advances in the theoretical understanding of quantum detection and mixing at millimeter and submillimeter wavelengths, has made the development of CAD techniques for superconducting nonlinear circuits an important new enterprise. For example, arrays of quasioptical mixers are now being manufactured, where the antennas, matching networks, filters and superconducting tunnel junctions are all fabricated by depositing niobium and a variety of oxides on a single quartz substrate. There are no adjustable tuning elements on these integrated circuits, and therefore, one must be able to predict their electrical behavior precisely. This requirement, together with a general interest in the generic behavior of devices such as direct detectors and harmonic mixers, has lead us to develop a range of CAD tools for simulating the large-signal, small-signal, and noise behavior of superconducting tunnel junction circuits.

Withington, S.↗

Open-Structure Mixer For Detection Of Hydroxyl

Single structure comprises dielectric-filled paraboloidal reflector, dipole antenna at focus of paraboloid, and mixing circuit at antenna developed for detecting electromagnetic radiation emitted by hydroxyl radical at frequency of 2,520 GHz (wavelength of 119 micrometers). Structure regarded as prototype for class of improved direct-detector and heterodyne circuits operating at millimeter and submillimeter wavelengths.

Siegel, Peter H.↗

THz Spectroscopy of the Atmosphere

THz spectroscopy of the atmosphere has been driven by the need to make remote sensing measurements of OH. While the THz region can be used for sensitive detection on many atmospheric molecules, the THz region is the best region for measuring the diurnal behavior of stratospheric OH by remote sensing. The infrared region near 3 microns suffers from chemiluminescence and from spectral contamination due to water. The ultraviolet region near 300 nm requires solar illumination. The three techniques for OH emission measurements in the THz region include Fourier Transform interferometry, Fabry-Perot interferometry, and heterodyne radiometry. The first two use cryogenic direct detectors while the last technique uses a local oscillator and a mixer to down convert the THz signal to GHz frequencies. All techniques have been used to measure stratospheric OH from balloon platforms. OH results from the Fabry-Perot based FILOS instrument will be given. Heterodyne measurement of OH at 2.5 THz has been selected to be a component of the Microwave Limb Sounder on the Earth Observing System CHEM-1 polar satellite. The design of this instrument will be described. A balloon-based prototype heterodyne 2.5 THz radiometer had its first flight on, 24 May 1998. Results form this flight will be presented.

Pickett, Herbert M.↗

Proceedings of the Twelfth International Symposium on Space Terahertz Technology

The Twelfth International Symposium on Space Terahertz Technology was held February 14-16, 2001 in San Diego, California, USA. This symposium was jointly sponsored by the National Aeronautics and Space Administration (NASA) and the Jet Propulsion Laboratory, California Institute of Technology. The symposium featured sixty nine presentations covering a wide variety of technical topics relevant to Terahertz Technology. The presentations can be divided into five broad technology areas: Hot Electron Bolometers, superconductor insulator superconductor (SIS) technology, local oscillator (LO) technology, Antennas and Measurements, and Direct Detectors. The symposium provides scientists, engineers, and researchers working in the terahertz technology and science fields to engineers their work and exchange ideas with colleagues.

Mehdi, Imran↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

Silicon Hot-Electron Bolometers

We discuss a new type of direct detector, a silicon hot-electron bolometer, for measurements in the far-infrared and submillimeter spectral ranges. High performance bolometers can be made using the electron-phonon conductance in heavily doped silicon to provide thermal isolation from the cryogenic bath. Noise performance is expected to be near thermodynamic limits, allowing background limited performance for many far infrared and submillimeter photometric and spectroscopic applications.

Stevenson, Thomas R.↗