Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dilute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Combinatorial Discovery of Lanthanum–Tantalum Oxynitride Solar Light Absorbers with Dilute Nitrogen for Solar Fuel Applications

© 2017 American Chemical Society. Oxynitrides with the photoelectrochemical stability of oxides and desirable band energetics of nitrides comprise a promising class of materials for solar photochemistry. Challenges in synthesizing a wide variety of oxynitride materials has limited exploration of this class of functional materials, which we address using a reactive cosputtering combined with rapid thermal processing method to synthesize multi-cation-multi-anion libraries. We demonstrate the synthesis of a LaxTa1-xOyNzthin film composition spread library and its characterization by both traditional thin film materials characterization and custom combinatorial optical spectroscopy and X-ray absorption near edge spectroscopy (XANES) techniques, ultimately establishing structure-chemistry-property relationships. We observe that over a substantial La-Ta composition range the thin films crystallize in the same perovskite LaTaON2structure with significant variation of anion chemistry. The relative invariance in optical band gap demonstrates a remarkable decoupling of composition and band energetics so that the composition can be optimized while retaining the desirable 2 eV band gap energy. We also demonstrate the intercalation of diatomic nitrogen into the La3TaO7structure, which gives rise to a direct-allowed optical transition at 2.2 eV, less than half the value of the oxide's band gap. These findings motivate further exploration of the visible light response of this material that is predicted to be stable over a wide range of electrochemical potential.

Suram, Santosh K.↗

Theory-Enabled High-Throughput Screening of Ion Dissociation Explains Conductivity Enhancements in Diluted Ionic Liquid Mixtures

The growing demand for room-temperature ionic liquids (RTILs) for energy applications necessitates the development of an efficient screening platform. Here, in this study, we successfully developed a fully automated high-throughput RTIL screening platform specifically designed for assessing ionic conductivity. By utilizing the 96 wells of a microtiter plate as individual electrolysis cells, we measured the ionic conductivity of 22 different RTILs, encompassing various combinations of cations and anions, and benchmarked the values with existing literature. We also employed the screening platform to investigate the conductivities of RTIL mixtures with a nonaqueous solvent, ethylene glycol (EG). Specific combinations of RTILs with EG result in approximately 200% enhancement in the conductivity values compared to the pure RTILs. To understand the underlying mechanisms responsible for this enhancement, we developed a theoretical framework for ionic conductivity that considers factors such as the degree of dissociation, viscous forces, and molal volume of the RTIL-EG mixtures. The optimized electrolyte mixture was then employed in the migration-assisted moisture gradient (MAMG) CO 2 capture process to study the effects of improved ionic conductivity on the energy efficiency of the process. Notably, the enhanced conductivity of the RTIL-EG mixture led to a nearly 50% reduction in energy consumption for capturing CO 2 . These outcomes highlight the effectiveness of our strategy in screening RTILs and improving existing processes. Moreover, this fully automated high-throughput setup, combined with the developed theoretical framework, provides a comprehensive platform for screening and studying RTIL mixtures with different solvents, enabling their application in various fields.

25 ENERGY STORAGE↗

Rhombohedral magnetostriction in dilute iron (Co) alloys

Iron is a well-utilized material in structural and magnetic applications. This does not mean, however, that it is well understood, especially in the field of magnetostriction. In particular, the rhombohedral magnetostriction of iron, λ{sub 111}, is anomalous in two respects: it is negative in sign, in disagreement with the prediction of first principles theory, and its magnitude decreases with increasing temperature much too rapidly to be explained by a power law dependence on magnetization. These behaviors could arise from the location of the Fermi level, which leaves a small region of the majority 3d t{sub 2g} states unfilled, possibly favoring small internal displacements that split these states. If this view is correct, adding small amounts of Co to Fe fills some of these states, and the value of λ{sub 111} should increase toward a positive value, as predicted for perfect bcc Fe. We have measured the magnetostriction coefficients (λ{sub 111} and λ{sub 100}) of pure Fe, Fe{sub 97}Co{sub 3}, and Fe{sub 94}Co{sub 6} single crystals from 77 K to 450 K. Resonant ultrasound spectroscopy has been used to check for anomalies in the associated elastic constants, c{sub 44} and c′. The additional electrons provided by the cobalt atoms indeed produced positive contributions to both magnetostriction constants, λ{sub 111} and λ{sub 100}, exhibiting an increase of 2.8 × 10{sup −6} per at. % Co for λ{sub 111} and 3.8 × 10{sup −6} per at. % Co for λ{sub 100}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control of hybrid boosting in highly diluted internal combustion engines

A novel hybrid system enabling both flexible supercharging and limited torque assist is studied to mitigate transient response challenges of a turbocharged spark ignition engine equipped with low pressure exhaust gas recirculation. The hybrid system, called a power split supercharger (SC), is configured with a planetary gear set that splits the supercharging power between a small low-voltage electric motor and the engine crankshaft. The air path controller relies on the coordination of four actuators on the engine side and three low-level actuators on the hybrid boosting device. A decentralized control scheme is used in this work, in which the master–slave structure of the boost pressure controller decreases the turbo-lag associated with exhaust gas recirculation, while minimizing the SC operation for fuel economy. A vector reference governor is used to prevent compressor surge during engine tip-outs. In addition, the desired intake manifold pressure is modified to provide time for evacuating the exhaust gas recirculation and avoiding misfires when transitioning to low load, while the hybrid capability of the power split SC is used to recuperate the unwanted generated power. All controllers are validated on both a mean value engine model and a high-fidelity engine model. Practical challenges of implementing the vector reference governor to the highly nonlinear engine air path with pressure pulsations originating from the engine reciprocation are discussed and some solutions are proposed.

Engineering↗

Recycling of Dilute Deacetylation Black Liquor to Enable Efficient Recovery and Reuse of Spent Chemicals and Biomass Pretreatment Waste

Previous publications showed deacetylation/dilute alkaline pretreatment followed by mechanical refining (DMR) is an effective process for overcoming biomass recalcitrance. To successfully commercialize alkaline-based pretreatments, we pioneered a new process modification and strategy to recycle and reuse the weak black liquor (WBL) to reduce water, chemical, and energy usage while increasing the solids, sodium, acetate, sugars, and lignin contents in the weak black liquor. Our results suggest that the accumulation of both chemicals and organic matter did not reduce acetyl and lignin removal in alkaline pretreatment, resulting in comparable sugar yields in enzymatic hydrolysis. Sodium and potassium were found to be the two most important inorganic substances in the recycled weak black liquor. Moreover, the accumulated sodium and phenolic compounds did not inhibit the downstream fermentation and ethanol fermentation processes. Finally, techno-economic analysis (TEA) showed the recycling of weak black liquor could decrease the minimum ethanol selling price (MESP) by approximately 5 to 15 cents per gallon of ethanol when compared to a conventional non-recycling process. solids, sodium, acetate, sugars, and lignin contents in the weak black liquor. Our results suggest that the accumulation of both chemicals and organic matter did not reduce acetyl and lignin removal in alkaline pretreatment, resulting in comparable sugar yields in enzymatic hydrolysis. Sodium and potassium were found to be the two most important inorganic substances in the recycled weak black liquor. Moreover, the accumulated sodium and phenolic compounds did not inhibit the downstream fermentation and ethanol fermentation processes. Finally, techno-economic analysis (TEA) showed the recycling of weak black liquor could decrease the minimum ethanol selling price (MESP) by approximately 5 to 15 cents per gallon of ethanol when compared to a conventional non-recycling process.

09 BIOMASS FUELS↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Biodiesel Impact on Engine Lubricant Dilution During Active Regeneration of Aftertreatment Systems

Experiments were conducted with ultra low sulfur diesel (ULSD) and 20% biodiesel blends (B20) to compare lube oil dilution levels and lubricant properties for systems using late in-cylinder fuel injection for aftertreatment regeneration. Lube oil dilution was measured by gas chromatography (GC) following ASTM method D3524 to measure diesel content, by Fourier transform infrared (FTIR) spectrometry following a modified ASTM method D7371 to measure biodiesel content, and by a newly developed back-flush GC method that simultaneously measures both diesel and biodiesel. Heavy-duty (HD) engine testing was conducted on a 2008 6.7L Cummins ISB equipped with a diesel oxidation catalyst (DOC) and diesel particle filter (DPF). Stage one of engine testing consisted of 10 consecutive repeats of a forced DPF regeneration event. This continuous operation with late in-cylinder fuel injection served as a method to accelerate lube-oil dilution. Stage two consisted of 16 hours of normal engine operation over a transient test cycle, which created an opportunity for any accumulated fuel in the oil sump to evaporate. Light duty (LD) vehicle testing was conducted on a 2010 VW Jetta equipped with DOC, DPF and a NOx storage catalyst (NSC). Vehicle testing comprised approximately 4,000 miles of operation on a mileage-accumulation dynamometer (MAD) using the U.S. Environmental Protection Agency's Highway Fuel Economy Cycle because of the relatively low engine oil and exhaust temperatures, and high DPF regeneration frequency of this cycle relative to other cycles examined. Comparison of the lube oil dilution analysis methods suggests that D3524 does not measure dilution by biodiesel. The new back-flush GC method provided analysis for both diesel and biodiesel, in a shorter time and with lower detection limit. Thus all lube oil dilution results in this paper are based on this method. Analysis of the HD lube-oil samples showed only 1.5% to 1.6% fuel dilution for both fuels during continuous operation under DPF regeneration events. During the second stage of HD testing, the ULSD lube-oil dilution levels fell from 1.5% to 0.8%, while for B20, lube-oil dilution levels fell from 1.6% to 1.0%, but the fuel in the oil was 36% biodiesel. For the LD vehicle tests, the frequency of DPF regeneration events was observed to be the same for both ULSD and B20. No significant difference between the two fuels' estimated soot loading was detected by the engine control unit (ECU), although a 23% slower rate of increase in differential pressure across DPF was observed with B20. It appears that the ECU estimated soot loading is based on the engine map, not taking advantage of the lower engine-out particulate matter from the use of biodiesel. After 4,000 miles of LD vehicle operation with ULSD, fuel dilution in the lube-oil samples showed total dilution levels of 4.1% diesel. After 4,000 miles of operation with B20, total fuel in oil dilution levels were 6.7% consisting of 3.6% diesel fuel and 3.1% biodiesel. Extrapolation to the 10,000-mile oil drain interval with B20 suggests that the total fuel content in the oil could reach 12%, compared to 5% for operation on ULSD. Analysis of the oil samples also included measurement of total acid number, total base number, viscosity, soot, metals and wear scar; however, little difference in these parameters was noted.

09 BIOMASS FUELS↗

The Effect of Dilution on the Structure of Microbial Communities

To determine how dilution of microbial communities affects the diversity of the diluted assemblage a series of numerical simulations were conducted that determined the theoretical change in diversity, richness, and evenness of the community with serial dilution. The results of the simulation suggested that the effects are non linear with a high degree of dependence on the initial evenness of the community being diluted. A series of incubation experiments using a range of dilutions of raw sewage as an inoculum into sterile sewage was used for comparison to the simulations. The diluted communities were maintained in batch fed reactors (three day retention time) for nine days. The communities were harvested and examined by conventional plating and by molecular analysis of the whole-community DNA using AFLP and T-RFLP. Additional, CLPP analysis was also applied. The effects on richness predicted by the numerical simulations were confirmed by the analyses used. The diluted communities fell into three groups, a low dilution, intermediate dilution, and high dilution group, which corresponded well with the groupings obtained for community richness in simulation. The grouping demonstrated the non-linear nature of dilution of whole communities. Furthermore, the results implied that the undiluted community consisted of a few dominant types accompanied by a number of rare (low abundance) types as is typical in unevenly distributed communities.

Mills, Aaron L.↗