Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electron tomography imaging methods with diffraction contrast for materials research

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

36 MATERIALS SCIENCE↗

The Detection of Monoclinic Zirconia and Non-Uniform 3D Crystallographic Strain in a Re-Oxidized Ni-YSZ Solid Oxide Fuel Cell Anode

The solid oxide fuel cell (SOFC) anode is often composed of nickel (Ni) and yttria-stabilized zirconia (YSZ). The yttria is added in small quantities (e.g., 8 mol %) to maintain the crystallographic structure throughout the operating temperatures (e.g., room-temperature to >800 °C). The YSZ skeleton provides a constraining structural support that inhibits degradation mechanisms such as Ni agglomeration and thermal expansion miss-match between the anode and electrolyte layers. Within this structure, the Ni is deposited in the oxide form and then reduced during start-up; however, exposure to oxygen (e.g., during gasket failure) readily re-oxidizes the Ni back to NiO, impeding electrochemical performance and introducing complex structural stresses. In this work, we correlate lab-based X-ray computed tomography using zone plate focusing optics, with X-ray synchrotron diffraction computed tomography to explore the crystal structure of a partially re-oxidized Ni/NiO-YSZ electrode. These state-of-the-art techniques expose several novel findings: non-isotropic YSZ lattice distributions; the presence of monoclinic zirconia around the oxidation boundary; and metallic strain complications in the presence of variable yttria content. This work provides evidence that the reduction–oxidation processes may destabilize the YSZ structure, producing monoclinic zirconia and microscopic YSZ strain, which has implications upon the electrode’s mechanical integrity and thus lifetime of the SOFC.

25 ENERGY STORAGE↗

Diffraction and coherence in breast ultrasound tomography: a study with a toroidal array

Ultrasound is commonly used as an adjunct to mammography for diagnostic evaluation of suspicions arising from breast cancer screening. As an alternative to conventional sonography that uses hand-held transducers, toroidal array probes that encircle the breast immersed in a water bath have been investigated for ultrasound tomography. In this paper, two sets of experiments performed with a prototype ultrasound scanner on a phantom and a human breast in vivo are used to investigate the effects of diffraction and coherence in ultrasound tomography. Reconstructions obtained with transmission diffraction tomography (TDT) are compared with conventional reflection imaging and computerized ultrasound tomography showing a substantial improvement. The in vivo tests demonstrate that TDT can image the complex boundary of a cancer mass and suggest that it can reveal the anatomy of milk ducts and Cooper's ligaments.

60 APPLIED LIFE SCIENCES↗

X-ray computed tomography using partially coherent Fresnel diffraction with application to an optical fiber

A reconstruction algorithm for partially coherent x-ray computed tomography (XCT) including Fresnel diffraction is developed and applied to an optical fiber. The algorithm is applicable to a high-resolution tube-based laboratory-scale x-ray tomography instrument. The computing time is only a few times longer than the projective counterpart. The algorithm is used to reconstruct, with projections and diffraction, a tilt series acquired at the micrometer scale of a graded-index optical fiber using maximum likelihood and a Bayesian method based on the work of Bouman and Sauer. The inclusion of Fresnel diffraction removes some reconstruction artifacts and use of a Bayesian prior probability distribution removes others, resulting in a substantially more accurate reconstruction.

Levine, Zachary H. (ORCID:000000029928276X)↗

On the effect of x-ray irradiation on the deformation and fracture behavior of human cortical bone

In situ mechanical testing coupled with imaging using high-energy synchrotron x-ray diffraction or tomography imaging is gaining in popularity as a technique to investigate micrometer and even sub-micrometer deformation and fracture mechanisms in mineralized tissues, such as bone and teeth. However, the role of the irradiation in affecting the nature and properties of the tissue is not always taken into account. Accordingly, we examine here the effect of x-ray synchrotron-source irradiation on the mechanistic aspects of deformation and fracture in human cortical bone. Specifically, the strength, ductility and fracture resistance (both work-of-fracture and resistance-curve fracture toughness) of human femoral bone in the transverse (breaking) orientation were evaluated following exposures to 0.05, 70, 210 and 630 kGy irradiation. Our results show that the radiation typically used in tomography imaging can have a major and deleterious impact on the strength, post-yield behavior and fracture toughness of cortical bone, with the severity of the effect progressively increasing with higher doses of radiation. Plasticity was essentially suppressed after as little as 70 kGy of radiation; the fracture toughness was decreased by a factor of five after 210 kGy of radiation. Mechanistically, the irradiation was found to alter the salient toughening mechanisms, manifest by the progressive elimination of the bone's capacity for plastic deformation which restricts the intrinsic toughening from the formation 'plastic zones' around crack-like defects. Deep-ultraviolet Raman spectroscopy indicated that this behavior could be related to degradation in the collagen integrity.

36 MATERIALS SCIENCE↗

Probing the Small- x Gluon Tomography in Correlated Hard Diffractive Dijet Production in Deep Inelastic Scattering

The close connection between the quantum phase space Wigner distribution of small-x gluons and the color dipole scattering amplitude is investigated, and studying it experimentally is proposed in the hard diffractive dijet production at the planned electron-ion collider. The angular correlation between the nucleon recoiled momentum and the dijet transverse momentum probes the nontrivial correlation in the phase space Wigner distribution. This experimental study not only provides three-dimensional tomographic pictures of gluons inside high energy protons - it gives a unique and interesting signal for the small-x dynamics with QCD evolution effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3d Crystallographic Orientation of Olivine in Bjurböle Chondrules

The crystallographic orientations of chondrule minerals can provide important insights into their formation and deformational history. For example, the orientations of the olivine bars and surrounding rim in barred olivine chondrules provide information and on the conditions of crystallization and the orientations and shapes of olivines within porphritic chondrules can record the reactions with the surrounding nebular gas during chondrule formation. Later deformation on the parent body can cause crystal-plastic deformation of chondrule minerals that is evident through their intracrystalline lattice misorientations. Typically these crystal orientations and lattice misorientations are determined using electron backscatter diffraction (EBSD) on thin sections but this gives only a 2D picture for what is actually a 3D texture. While it is possible to combine EBSD with serial sectioning to build a 3D dataset of texture, this is a destructive, time-intensive process. A recent technological development that enables non-destructive, 3D crystallographic orientation measurement is X-ray diffraction contrast tomography (DCT), which uses the X-ray diffraction of the crystal lattice to determine orientation. Originally only possible using monochromatic X-ray beams at 3rd generation synchrotron light sources, DCT has been recently adapted to polychromatic sources of laboratory X-ray microscopes (referred to as Lab-DCT). Up to this point LabDCT has only been applied to large, well-formed crystals of high symmetry (i.e., metals), but we recently acquired DCT datasets for a pair Bjurböle chondrules to determine the applicability of the technique to natural, mutlimineralic samples composed predominately of olivine (i.e., chondrules).

Hanna, R. D.↗

X-ray nanoprobes and diffraction-limited storage rings: opportunities and challenges of fluorescence tomography of biological specimens

X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer.

de Jonge, Martin D.↗

Experimental investigation of the dependence of void nucleation and growth on initial microstructure in high-purity titanium under tension

An experimental investigation of failure mechanisms in relation to the initial microstructure in high-purity titanium samples is presented. The initial microstructure of the specimens was measured in 3D using diffraction-contrast tomography (DCT). Ex-situ X-ray computed tomography (XCT) was used to visualize voids in specimens at various levels of deformation attained by interrupted tensile testing. Electron backscatter diffraction (EBSD) mapping was used to characterize the deformed microstructures per specimen. The investigation showed that the location of failures was unrelated to the formation of the first voids, but rather the nucleation and growth of cracks were from heavily deformed surface regions. The areas surrounding the failure-causing cracks had the highest propensity for void development of any area in the specimen. This facilitated crack propagation through the specimen via “linking up”. The failure of the specimens by microvoid coalescence was bolstered by “dimpled” fracture surfaces. Paint composed of gallium embedded in rubber was used to track the displacement of points along the loading direction of the specimens, to relate the location of failure to the material's initial microstructure. However, the correlation proved difficult, due to complex microstructural evolution involving voids, grain fragmentations, and profuse twinning. Nevertheless, it was shown that necking occurred near the largest grain in the gauge section of the specimens. This is likely caused by the decrease in strength of larger grains, causing strain to concentrate in their vicinity. Here, a comprehensive picture of the failure processes in high-purity titanium under axial loading is presented and discussed in the paper.

36 MATERIALS SCIENCE↗

Correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition using neutron diffraction and imaging techniques

In a directed energy deposition (DED) process, the energy density deposited into the materials drives the structure and properties. The energy density is influenced by several printing parameters, such as laser power, hatch spacing, scanning speed, etc. In this study, 316L stainless steels samples were fabricated with varying hatch spacing aiming to induce variations in sample microstructure and properties. A combination of techniques including engineering neutron diffraction, neutron computed tomography, and tensile testing, were employed to correlate the structure and macroscopic properties. Porosity was predominantly observed at the bottom of the deposited materials and was effectively reduced by decreased hatch spacing. Correlatively, compressive residual stress was observed at the bottom of the specimens, while internal stress is largely determined by the hatch spacing. The residual stress in general decreases as the hatch spacing decreases. The maximum ultimate tensile strength (UTS) was found to increase from 517.4 to 528.6 MPa with a strain increased from 0.847 to 0.897 as the hatch spacing decreased from 0.45 to 0.42 mm. However, further increase in energy density by reducing the hatch spacing resulted in a significant decrease in UTS (as low as 452 MPa). This work provides new insights from bulk non-destructive techniques into correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition.

316L stainless steel↗

3D analysis of abnormal grain growth in calcia doped alumina in the presence of large pores

Abnormal grain growth has been previously found to increase with the inclusion of large pores (∼60 µm in diameter) in 80 ppm calcium doped alumina. However, the two-dimensional analysis could not accurately describe the proximity of the abnormal grains and pores to establish a correlation. This study uses laboratory-based diffraction contrast tomography and x-ray computed tomography to spatially map the pores and abnormal grains in 3D. A preference towards the formation of abnormal grains near large pores is found when compared to all potential sites. This finding supports that the pores may be a nucleation site for complexion transitions that promote abnormal grain growth. The growth of the abnormal grains in a subsequent heat treatment at 1600°C for 16 hrs was also studied. The elongation along the principal axes is similar for both small and large grains, again supporting that abnormal grain growth was facilitated by a complexion transition.

Abnormal grain growth↗

Identification of mechanisms driving heterogeneous void growth in ductile aluminum

Void growth plays a central role in ductile fracture, yet the specific mechanisms that control this remain obscure. Classical models, such as those proposed by Rice and Tracey in 1969, are able to capture average rates of void growth, but cannot capture the heterogeneity of individual void growth. Building on recent work, the present study employs laboratory-based diffraction contrast tomography and in-situ x-ray computed tomography to investigate the effect of grain structure and other microstructural factors on void growth in an Al-2219 alloy. Crystal plasticity finite element (CP-FE) modeling is used alongside experimental data to evaluate the contributions of local mechanical states, grain orientation, grain size, and neighboring microstructural features. No strong linear relationships are found with any of the considered descriptors and void growth rate. Potential complex nonlinear relationships are explored with the use of a random forest regression model, which identifies initial void volume, void aspect ratio, local normal stress state, local shear stress state, and local equivalent plastic strain (EQPS) as features that most improve void growth rate predictions. The combination of these analyses suggests that these features should be prioritized to improve models of void growth.

Diffraction contrast tomography (DCT)↗

4D Observations of the initiation of abnormal grain growth in commercially pure Ni

Abnormal grain growth (AGG), where a small fraction of grains grow faster than others, is critical to predict because it can significantly impact material properties. However, the mechanism behind AGG remains unclear. In this study, laboratory-based x-ray diffraction contrast tomography (LabDCT) is employed to non-destructively track the 3D microstructural evolution of high-purity nickel during the onset of AGG at 800 °C. The initial microstructure state is used to test hypothesized microstructure predictors of the initiation of AGG. The change in grain size was not related to the initial grain size or normalized integral mean curvature. Additionally, the grain boundary energy distributions of abnormal grains were indistinguishable from those of control groups exhibiting normal grain growth. However, the grains that later became abnormal exhibit large areas of asymmetric tilt boundaries that were previously found to be fast. This 3D microstructure dataset is useful to investigate new hypotheses for the initiation of AGG.

36 MATERIALS SCIENCE↗

Spatial quantification of dynamic inter and intra particle crystallographic heterogeneities within lithium ion electrodes

The performance of lithium ion electrodes is hindered by unfavorable chemical heterogeneities that pre-exist or develop during operation. Time-resolved spatial descriptions are needed to understand the link between such heterogeneities and a cell's performance. Here, operando high-resolution X-ray diffraction-computed tomography is used to spatially and temporally quantify crystallographic heterogeneities within and between particles throughout both fresh and degraded Li x Mn 2 O 4 electrodes. This imaging technique facilitates identification of stoichiometric differences between particles and stoichiometric gradients and phase heterogeneities within particles. Through radial quantification of phase fractions, the response of distinct particles to lithiation is found to vary; most particles contain localized regions that transition to rock salt LiMnO 2 within the first cycle. Other particles contain monoclinic Li 2 MnO 3 near the surface and almost pure spinel LixMn2O4 near the core. Following 150 cycles, concentrations of LiMnO 2 and Li 2 MnO 3 significantly increase and widely vary between particles.

25 ENERGY STORAGE↗

Three-dimensional nanostructure determination from a large diffraction data set recorded using scanning electron nanodiffraction

A diffraction-based technique is developed for the determination of three-dimensional nanostructures. The technique employs high-resolution and low-dose scanning electron nanodiffraction (SEND) to acquire three-dimensional diffraction patterns, with the help of a special sample holder for large-angle rotation. Grains are identified in three-dimensional space based on crystal orientation and on reconstructed dark-field images from the recorded diffraction patterns. Application to a nanocrystalline TiN thin film shows that the three-dimensional morphology of columnar TiN grains of tens of nanometres in diameter can be reconstructed using an algebraic iterative algorithm under specified prior conditions, together with their crystallographic orientations. The principles can be extended to multiphase nanocrystalline materials as well. Thus, the tomographic SEND technique provides an effective and adaptive way of determining three-dimensional nanostructures.

36 MATERIALS SCIENCE↗