Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostic procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cooperative Education

M-3 Focused Experiments is a group at Los Alamos National Lab (LANL) and is under the Dynamic Experiments Division. Their work surrounds the diagnostics and study of explosives and their interaction with materials. The data collected is used to better understand the erratic nature of explosions and high velocity projectiles. Through better comprehension of this science, the overall national security will be improved while innovations are made along the way. Despite the strong drive for research and development, the lab holds safety above all else and constantly updates procedures to protect LANL employees and their environment. At any time, there are multiple projects going on at once within the team and I am tasked with assisting the Firing Site Leaders and various research diagnosticians in any way possible with the setup, testing, and execution of data collection for each experiment. Such data includes velocity, fragmentation characteristics, and the spread of energy across the material to name a few. During my summer employment with the lab, my main goal is to maintain a questioning attitude and learn as much possible about the research and development side of science and engineering. Throughout the duration of the Co-op, many experiments will take place at specially designed firing sites which is where I will be spending most of my time.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extension of charged-particle spectrometer capabilities for diagnosing implosions on OMEGA, Z, and the NIF

New designs and a new analysis technique have been developed for an existing compact charged-particle spectrometer on the NIF and OMEGA. The new analysis technique extends the capabilities of this diagnostic to measure arbitrarily shaped ion spectra down to 1 MeV with yields as low as 10 6 . Three different designs are provided optimized for the measurement of DD protons, T 3 He deuterons, and 3 He 3 He protons. The designs are highly customizable, and a generalized framework is provided for optimizing the design for alternative applications. Additionally, the understanding of the detector’s response and uncertainties is greatly expanded upon. A new calibration procedure is also developed to increase the precision of the measurements.

47 OTHER INSTRUMENTATION↗

The magnetic structure of long-wavelength magnetohydrodynamic modes in current-carrying stellarator plasmas

Magnetic field fluctuations are observed in current-carrying stellarator plasmas when the rotational transform is close to a rational value at the edge of the plasma. At low plasma pressure, these fluctuations are associated with perturbed currents parallel to the equilibrium magnetic field lines. A model for these magnetohydrodynamic modes in a low-β, three-dimensional stellarator equilibria has been developed. A set of helical current filaments are constrained to mimic the structure of magnetic field lines on rational surfaces derived from three-dimensional (3D) equilibrium reconstructions. Transformation to straight field line coordinates then allows fitting of the poloidal magnetic sensor data to a single harmonic function, which fixes the modeled toroidal mode structure via the field line flow geometry. The developed procedure accurately captures phase and amplitude variation for m/n = 3/2, 3/1, and 4/1 modes in the 3D equilibria of the compact toroidal hybrid experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

Global Issues of Radiopharmaceutical Access and Availability: a Nuclear Medicine Global Initiative Project

The Nuclear Medicine Global Initiative (NMGI) was formed in 2012 by 13 international organizations to promote human health by advancing the field of nuclear medicine and molecular imaging by supporting the practice and application of nuclear medicine. The first project focused on standardization of administered activities in pediatric nuclear medicine and resulted in two manuscripts. For its second project the NMGI chose to explore issues impacting on access and availability of radiopharmaceuticals around the world. Methods: Information was obtained by survey responses from 35 countries on available radioisotopes, radiopharmaceuticals and kits for diagnostic and therapeutic use. Issues impacting on access and availability of radiopharmaceuticals in individual countries were also identified. Results: Detailed information on radiopharmaceuticals utilized in each country, and sources of supply, was evaluated. Responses highlighted problems in access particularly due to the reliance on a sole provider, regulatory issues and reimbursement, as well as issues of facilities and workforce particularly in low- and middle-income countries. Conclusion: Finally, strategies to address access and availability of radiopharmaceuticals are outlined, to enable timely and equitable patient access to nuclear medicine procedures worldwide. In the face of disruptions to global supply chains by the COVID-19 outbreak, renewed focus on ensuring reliable supply of radiopharmaceuticals is a major priority for nuclear medicine practice globally.

43 PARTICLE ACCELERATORS↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization NPIC presentation

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Photonic Doppler Velocimetry for Valve Analysis and Surveillance

This study is an experimental evaluation to measure and surveil the velocity of stainless steel (Carpenter 455) pistons within a forged 21-6-9 stainless steel valve body. The velocity of the piston “stroke” will be identified using Photonic Doppler Velocimetry (PDV). The piston velocity will be the measured variable of interest. The outcome of this testing series provides further understanding to whether the extracted piston velocity can provide enough information to determine valve integrity. PDV has been identified as a diagnostic of interest as it can detect surface motion at high speeds with reliable accuracy. Through preliminary studies conducted with velocity interferometer system for any reflector (VISAR), the velocity of the piston is expected to stroke with a speed of 135 m/s. The PDV technique is much more reliable and repeatable than the VISAR technique because of its high-speed precision and accuracy, so it will not only validate the preliminary data, but also provide a testing technique that is capable of being used in future valve qualification efforts. The initial testing was completed using valves that were assembled per qualified procedures in a pristine condition. These initial tests were conducted to provide baseline data. This baseline data was then compared to data collected from valves where man-made defects were introduced. These defects are discussed in later sections. Lastly, actuators used to operate the valves were loaded with varied amounts of high explosives to identify if velocity is a function of the amount of explosive in an actuator. These parameters were adjusted to conclusively determine and identify if PDV can be used as a method to assess valve integrity. It was concluded through the testing discussed in this paper that in fact, PDV is capable of measuring the differences in piston velocities based on varied parameters. As far as understanding the PDV accuracy of the measured differences, this is ongoing and will have to be assessed in continued testing series.

42 ENGINEERING↗

Using solenoid as multipurpose tool for measuring beam parameters

Solenoids are frequently used for focusing low-energy beams. In this paper, we show how they can serve as multipurpose diagnostics tools to measure various beam parameters, including energy, emittance, the second moments of the transverse distribution, and the beam position and angle with respect to the solenoid’s axis. The energy measurement is based on rotation of the plane of the transverse motion, as opposed to generating dispersion with a dipole. Measurement of the beam trajectory with respect to the solenoid axis is done by analyzing the beam orbit downstream of the solenoid while varying its current. The second moments are calculated by analyzing the beam image on a profile monitor while accounting for the beam rotation caused by the solenoid. We describe in detail the corresponding procedures and the experimental results of these measurements.

43 PARTICLE ACCELERATORS↗

Lost alpha Faraday cup foil noise characterization during Joint European Torus plasma post-processing analysis

Capacitive plasma pickup is a well-known and difficult problem for plasma-facing edge diagnostics. This problem must be addressed to ensure an accurate and robust interpretation of the real signal measurements vs noise. The Faraday cup fast ion loss detector array of the Joint European Torus (JET) is particularly prone to this issue and can be used as a testbed to prototype solutions. The issue of separation and distinction between warranted fast ion signal and electromagnetic plasma noise has traditionally been solved with hardware modifications, but a more versatile post-processing approach is of great interest. This work presents post-processing techniques to characterize the signal noise. While hardware changes and advancements may be limited, the combination with post-processing procedures allows for more rapid and robust analysis of measurements. The characterization of plasma pickup noise is examined for alpha losses in a discharge from JET’s tritium campaign. In addition to highlighting the post-processing methodology, the spatial sensitivity of the detector array is also examined, which presents significant advantages for the physical interpretation of fast ion losses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Mockups and Instrumentation for Spent Fuel Drying Tests

The purpose of this report is to provide updates on the experimental components, methodology, and instrumentation under development for use in advanced studies of realistic drying operations conducted on surrogate spent nuclear fuel. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters upon completion of drying procedures can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Additional information is needed on the drying process efficacy to help evaluate the potential impacts of water retention on extended longterm dry storage. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report describes the implementation of moisture monitoring equipment on a pressurized, submersible system employing a single waterproof, electrically heated spent fuel rod simulator as a demonstration of analytical capabilities during a drying process. A mass spectrometer with specially designed inlets was used to monitor moisture and other gases at 150 kPa to 800 kPa for a test simulating a forced helium dehydration procedure and below 1 torr for tests mimicking a vacuum drying process. The dew point data from the mass spectrometer was found to be in good agreement with a solid-state moisture probe. A distinct advantage of the mass spectrometer system was the capability to directly sample from the hightemperature (>200 °C) head space expected in a prototypic scale experiment where a solid-state moisture probe would suffer considerable loss of accuracy or fail altogether. The operational and analytical experiences gained from this test series are poised to support an expansion to assembly-scale tests at prototypic length. These assemblies are designed to feature prototypic assembly hardware, advanced diagnostics for in situ internal rod pressure monitoring, and failed fuel rod simulators with engineered cladding defects to challenge the drying system with waterlogged fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Deep graph representations embed network information for robust disease marker identification

We report that the accurate disease diagnosis and prognosis based on omics data rely on the effective identification of robust prognostic and diagnostic markers that reflect the states of the biological processes underlying the disease pathogenesis and progression. In this article, we present GCNCC, a Graph Convolutional Network-based approach for Clustering and Classification, that can identify highly effective and robust network-based disease markers. Based on a geometric deep learning framework, GCNCC learns deep network representations by integrating gene expression data with protein interaction data to identify highly reproducible markers with consistently accurate prediction performance across independent datasets possibly from different platforms. GCNCC identifies these markers by clustering the nodes in the protein interaction network based on latent similarity measures learned by the deep architecture of a graph convolutional network, followed by a supervised feature selection procedure that extracts clusters that are highly predictive of the disease state. By benchmarking GCNCC based on independent datasets from different diseases (psychiatric disorder and cancer) and different platforms (microarray and RNA-seq), we show that GCNCC outperforms other state-of-the-art methods in terms of accuracy and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

2D coherence imaging measurements of C 2+ ion temperatures in the divertor of Wendelstein 7-X

For the first time, 2D ion temperature values are derived from coherence imaging spectroscopy (CIS) fringe contrast measurements by taking Zeeman line broadening effects into account during the analysis procedure of a spatial-heterodyne CIS instrument. This allowed 2D images of C 2+ ion temperatures (T i ) across the 3D-shaped island divertor of the Wendelstein 7-X stellarator. Ion temperatures ranging from 10 to 20 eV are observed for the C 2+ impurity species in the region above the divertor targets. During the transition from the attached to the detached plasma state, the C 2+ radiation zone moves from close to the divertor target towards the last closed flux surface. Within this radiation zone, C 2+ temperature does not decrease significantly. Experimentally, the coherence imaging measurements were cross-calibrated at one poloidal cross-section using a high resolution Echelle spectrometer, that shared its sightlines with the coherence imaging diagnostic. The spectra demonstrated that, apart from Doppler broadening, the Zeeman effect significantly contributes to the spectral line broadening and cannot be neglected when analyzing the CIS contrast data for T i extraction in the edge and scrape-off-layer of Wendelstein 7-X (W7-X), due to the relatively low temperatures (T i < 100 eV) and high magnetic fields (B ≈ 2.5 T).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗