Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quartz/fused silica chip carriers

The primary objective of this research and development effort was to develop monolithic microwave integrated circuit (MMIC) packaging which will operate efficiently at millimeter-wave frequencies. The packages incorporated fused silica as the substrate material which was selected due to its favorable electrical properties and potential performance improvement over more conventional materials for Ka-band operation. The first step towards meeting this objective is to develop a package that meets standard mechanical and thermal requirements using fused silica and to be compatible with semiconductor devices operating up to at least 44 GHz. The second step is to modify the package design and add multilayer and multicavity capacity to allow for application specific integrated circuits (ASIC's) to control multiple phase shifters. The final step is to adapt the package design to a phased array module with integral radiating elements. The first task was a continuation of the SBIR Phase 1 work. Phase 1 identified fused silica as a viable substrate material by demonstrating various plating, machining, and adhesion properties. In Phase 2 Task 1, a package was designed and fabricated to validate these findings. Task 2 was to take the next step in packaging and fabricate a multilayer, multichip module (MCM). This package is the predecessor to the phased array module and demonstrates the ability to via fill, circuit print, laminate, and to form vertical interconnects. The final task was to build a phased array module. The radiating elements were to be incorporated into the package instead of connecting to it with wire or ribbon bonds.

Source record↗

Digital filter for voiceband noise

Device operates over 300 to 3000 hertz range and contains 10 bit, 10 kilohertz converters and equally fast registers. Combination and weights of digital samples of analog signal are utilized by device to reconstruct signal with noise above 3000 hertz eliminated.

Edwards, T. R.↗

Operation of integrating indium antimonide linear arrays at 65 K and below

The combination of a FET switch non-CCD readout architecture with high-quality mesa-photovoltaic indium-antimonide detector material has led to high-performance integrating linear imagers in the 1- to 5-micron region. These devices operate in the temperature regime below 100 K and provide very good dark current and responsivity uniformity (+ or - 2 percent). Test data will show performance at 65 K for a 512-element array and 46 K for a 128-element array. Useful integration times of 3600 seconds at 46 K and greater than 12 seconds at 65 K have been achieved. For both devices, kTC read noise levels of less than 1200 electrons have been measured.

Bailey, G. C.↗

Power-Efficient, High-Current-Density, Long-Life Thermionic Cathode Developed for Microwave Amplifier Applications

A power-efficient, miniature, easily manufactured, reservoir-type barium-dispenser thermionic cathode has been developed that offers the significant advantages of simultaneous high electron-emission current density (>2 A/sq cm) and very long life (>100,000 hr of continuous operation) when compared with the commonly used impregnated-type barium-dispenser cathodes. Important applications of this cathode are a wide variety of microwave and millimeter-wave vacuum electronic devices, where high output power and reliability (long life) are essential. We also expect it to enable the practical development of higher purveyance electron guns for lower voltage and more reliable device operation. The low cathode heater power and reduced size and mass are expected to be particularly beneficial in traveling-wave-tube amplifiers (TWTA's) for space communications, where future NASA mission requirements include smaller onboard spacecraft systems, higher data transmission rates (high frequency and output power) and greater electrical efficiency.

Wintucky, Edwin G.↗

A linear magnetic motor and generator

In linear magnetic motor and generator suitable for remote and hostile environments, magnetic forces drive reciprocating shaft along its axis. Actuator shaft is located in center of cylindrical body and may be supported by either contacting or noncontacting bearings. When device operates as bidirectional motor, drive coil selectively adds and subtracts magnetic flux to and from flux paths, producing forces that drive actuator along axis. When actuator is driven by external reciprocating engine, device becomes ac generator.

Studer, P. A.↗

Single Particle Damage Events in Candidate Star Camera Sensors

Si charge coupled devices (CCDs) are currently the preeminent detector in star cameras as well as in the near ultraviolet (uv) to visible wavelength region for astronomical observations in space and in earth-observing space missions. Unfortunately, the performance of CCDs is permanently degraded by total ionizing dose (TID) and displacement damage effects. TID produces threshold voltage shifts on the CCD gates and displacement damage reduces the charge transfer efficiency (CTE), increases the dark current, produces dark current nonuniformities and creates random telegraph noise in individual pixels. In addition to these long term effects, cosmic ray and trapped proton transients also interfere with device operation on orbit. In the present paper, we investigate the dark current behavior of CCDs - in particular the formation and annealing of hot pixels. Such pixels degrade the ability of a CCD to perform science and also can present problems to the performance of star camera functions (especially if their numbers are not correctly anticipated). To date, most dark current radiation studies have been performed by irradiating the CCDs at room temperature but this can result in a significantly optimistic picture of the hot pixel count. We know from the Hubble Space Telescope (HST) that high dark current pixels (so-called hot pixels or hot spikes) accumulate as a function of time on orbit. For example, the HST Advanced Camera for Surveys/Wide Field Camera instrument performs monthly anneals despite the loss of observational time, in order to partially anneal the hot pixels. Note that the fact that significant reduction in hot pixel populations occurs for room temperature anneals is not presently understood since none of the commonly expected defects in Si (e.g. divacancy, E center, and A-center) anneal at such a low temperature. A HST Wide Field Camera 3 (WFC3) CCD manufactured by E2V was irradiated while operating at -83C and the dark current studied as a function of temperature while the CCD was warmed to a sequence of temperatures up to a maximum of +30C. The device was then cooled back down to -83 and re-measured. Hot pixel populations were tracked during the warm-up and cool-down. Hot pixel annealing began below 40C and the anneal process was largely completed before the detector reached +3OC. There was no apparent sharp temperature dependence in the annealing. Although a large fraction of the hot pixels fell below the threshold to be counted as a hot pixel, they nevertheless remained warmer than the remaining population. The details of the mechanism for the formation and annealing of hot pixels is not presently understood, but it appears likely that hot pixels are associated with displacement damage occurring in high electric field regions.

Marshall, Paul↗

PDSOI and Radiation Effects: An Overview

Bulk silicon substrates are a common characteristic of nearly all commercial, Complementary Metal-Oxide-Semiconductor (CMOS), integrated circuits. These devices operate well on Earth, but are not so well received in the space environment. An alternative to bulk CMOS is the Silicon-On-Insulator (SOI), in which a &electric isolates the device layer from the substrate. SO1 behavior in the space environment has certain inherent advantages over bulk, a primary factor in its long-time appeal to space-flight IC designers. The discussion will investigate the behavior of the Partially-Depleted SO1 (PDSOI) device with respect to some of the more common space radiation effects: Total Ionized Dose (TID), Single-Event Upsets (SEUs), and Single-Event Latchup (SEL). Test and simulation results from the literature, bulk and epitaxial comparisons facilitate reinforcement of PDSOI radiation characteristics.

Forgione, Joshua B.↗

High-Temperature, Wirebondless, Ultracompact Wide Bandgap Power Semiconductor Modules

Silicon carbide (SiC) and other wide bandgap semiconductors offer great promise of high power rating, high operating temperature, simple thermal management, and ultrahigh power density for both space and commercial power electronic systems. However, this great potential is seriously limited by the lack of reliable high-temperature device packaging technology. This Phase II project developed an ultracompact hybrid power module packaging technology based on the use of double lead frames and direct lead frame-to-chip transient liquid phase (TLP) bonding that allows device operation up to 450 degC. The new power module will have a very small form factor with 3-5X reduction in size and weight from the prior art, and it will be capable of operating from 450 degC to -125 degC. This technology will have a profound impact on power electronics and energy conversion technologies and help to conserve energy and the environment as well as reduce the nation's dependence on fossil fuels.

Elmes, John↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through-transmission mode using two transducers, or in pulse-echo mode. The transducer is a unique combination of material, design, and fabrication technique. It is based on single-crystal lead magnesium niobate lead titanate (PMN-PT) piezoelectric material. As compared to the commonly used piezoceramics, this piezocrystal has superior piezoelectric and elastic properties, which results in devices with superior bandwidth, source level, and power requirements. This design necessitates a single resonant frequency. However, by operating in a transverse length-extensional mode, with the electric field applied orthogonally to the extensional direction, resonators of different sizes can share common electrodes, resulting in a multiply-resonant structure. With carefully sized resonators, and the superior bandwidth of piezocrystal, the resonances can be made to overlap to form a smooth, wide-bandwidth characteristic.

Liang, Yu↗

Functional design for operational earth resources ground data processing

The author has identified the following significant results. Study emphasis was on developing a unified concept for the required ground system, capable of handling data from all viable acquisition platforms and sensor groupings envisaged as supporting operational earth survey programs. The platforms considered include both manned and unmanned spacecraft in near earth orbit, and continued use of low and high altitude aircraft. The sensor systems include both imaging and nonimaging devices, operated both passively and actively, from the ultraviolet to the microwave regions of the electromagnetic spectrum.

Baldwin, C. J.↗

Development of Advanced Laser Diode Sources

The design and operation of InGaAs-GaAs-AlGaAs asymmetric cladding ridge waveguide distributed Bragg reflector lasers is presented. Targeted for the remote sensing of water vapor with absorption lines in the lambda approximately 930 nm region, these devices operate CW with threshold currents as low as 11 MA and slope efficiencies as high as 0.37 W/A. Tbey also operate with over 30-dB side-mode suppression, and the typical CW characteristic temperature, T(sub o), is 95 K.

Coleman, J. J.↗

X-ray and extreme ultraviolet imaging using layered synthetic microstructures

Up to now designers of X-ray optical instruments such as microscopes and telescopes have been compelled to use mirrors operating at small glancing angles. However, using vapor deposition techniques, it is now possible to build multilayered thin film structures in which the individual layers have thicknesses comparable with a wavelength of X-rays. These devices operate in a manner exactly analogous to multilayer dielectric coatings at visible wavelengths and can be used to increase the X-ray and extreme ultraviolet reflectivity of surfaces at large glancing angles. These X-ray mirrors have numerous potential applications in X-ray optics. Attention is given to X-ray images with a normal incidence mirror, and applications of multilayer optics. Single-mirror telescopes for solar/stellar astronomy are discussed, taking into account solar corona and transition region studies, and X-ray and extreme ultraviolet astronomy. Hybrid X-ray telescopes are also considered.

Underwood, J. H.↗

Fiber Grating Coupled Light Source Capable of Tunable, Single Frequency Operation

Fiber Bragg grating coupled light sources can achieve tunable single-frequency (single axial and lateral spatial mode) operation by correcting for a quadratic phase variation in the lateral dimension using an aperture stop. The output of a quasi-monochromatic light source such as a Fabry Perot laser diode is astigmatic. As a consequence of the astigmatism, coupling geometrics that accommodate the transverse numerical aperture of the laser are defocused in the lateral dimension, even for apsherical optics. The mismatch produces the quadratic phase variation in the feedback along the lateral axis at the facet of the laser that excites lateral modes of higher order than the TM 00 . Because the instability entails excitation of higher order lateral submodes, single frequency operation also is accomplished by using fiber Bragg gratings whose bandwidth is narrower than the submode spacing. This technique is particularly pertinent to the use of lensed fiber gratings in lieu of discrete coupling optics. Stable device operation requires overall phase match between the fed-back signal and the laser output. The fiber Bragg grating acts as a phase-preserving mirror when the Bragg condition is met precisely. The phase-match condition is maintained throughout the fiber tuning range by matching the Fabry-Perot axial mode wavelength to the passband center wavelength of the Bragg grating.

Michael A Krainak↗

Power conversion efficiency of semiconductor injection lasers and laser arrays in CW operation

The problem of optimizing power conversion efficiency of semiconductor lasers and laser arrays and minimizing efficiency degradation due to temperature effects is treated. A method for calculating this efficiency is described and some calculated results are presented and discussed. Under some conditions, a small increase in the thermal resistance of the device can result in a large reduction of its efficiency. Temperature effects are important in high-power semiconductor laser, and in particular in laser arrays, where low thermal resistance heat sinking may be crucial to the device operation.

Katz, J.↗

Millimeter-wave generation with spiraling electron beams

The feasibility of using the interaction between a thin, solid, spiraling electron beam of 10 to 20 kV energy and a microwave cavity to generate watts of CW millimeter-wave power was investigated. Experimental results are given for several prototype devices operating at 9.4 GHz and at 94 GHz. Power outputs of 5 W, and electronic efficiencies near 3%, were obtained at X band, and moderate gain was obtained at 94 GHz. The small-signal theory gives a good fit to the X-band data, and the device behavior at 94 GHz is as expected from the given beam characteristics. The performance is limited chiefly by the velocity spread in the spiraling electron beam, and once this can be brought under control, high-power generation of millimeter waves appears quite feasible with this type of device.

Kulke, B.↗

Computational Tools to Design Molten Salt Electrolytes for High-Temperature Environments

Current Li-ion batteries are designed for a small operating window of 5 °C to 55 °C. Modifications to the electrolyte for operation in Mars atmosphere extended this range on the lower bound to ~ -40 °C. These operating-temperature ranges are far from those presented in high-temperature environments, such as the Venus surface, where temperatures are around 450 °C. Protecting the state-of-the-art Li-ion batteries require insulations that decreases the volumetric capacity and limiting the operational time-window. These unique challenges require a paradigm shift in materials used for designing high-temperature batteries. Molten salt electrolyte-based batteries offer a plausible route to designing high-temperature batteries. ZEBRA batteries are known to be one of the safest energy storage devices operating at 270-350 °C. Nitrate based eutectics, operating at 150 °C have also been used in Li-O2 batteries. In this study, we will examine molten-salt electrolyte transport and electrochemical properties using first-principles computations and benchmark against experiments. Further, we will present thermodynamics-based models for designing and predicting melting point of molten salt mixtures. Based on these computational tools, new molten salt mixtures designed with desired operating temperatures and electrochemical windows will be presented. Implications of these new eutectics in the context of high-temperature environment exploration will also be discussed.

Balachandran Radhakrishnan↗

Feasibility study, software design, layout and simulation of a two-dimensional fast Fourier transform machine for use in optical array interferometry

The NASA-Cornell Univ.-Worcester Polytechnic Institute Fast Fourier Transform (FFT) chip based on the architecture of the systolic FFT computation as presented by Boriakoff is implemented into an operating device design. The kernel of the system, a systolic inner product floating point processor, was designed to be assembled into a systolic network that would take incoming data streams in pipeline fashion and provide an FFT output at the same rate, word by word. It was thoroughly simulated for proper operation, and it has passed a comprehensive set of tests showing no operational errors. The black box specifications of the chip, which conform to the initial requirements of the design as specified by NASA, are given. The five subcells are described and their high level function description, logic diagrams, and simulation results are presented. Some modification of the Read Only Memory (ROM) design were made, since some errors were found in it. Because a four stage pipeline structure was used, simulating such a structure is more difficult than an ordinary structure. Simulation methods are discussed. Chip signal protocols and chip pinout are explained.

Boriakoff, Valentin↗

First Results of the Gasdynamic Mirror Experiment

An experimental Gasdynamic Mirror or GDM device has been constructed at the NASA Marshall Space Flight Center to provide an initial assessment of the applicability of this technology for propulsion systems. This paper presents the first experimental results obtained from the machine. It is intended that this device operate at higher plasma densities and with much larger L/D ratios than previous mirror machines. The high L/D ratio minimizes to a large extent certain magnetic curvature effects which lead to plasma instabilities causing a loss of plasma confinement. The high plasma density results in the plasma behaving much more like a conventional fluid with a mean free path shorter than the length of the device. This characteristic helps reduce problems associated with "loss cone" microinstabilities. The device has been constructed to allow a considerable degree of flexibility in its configuration thus permitting the experiment to grow over time without necessitating a great deal of additional fabrication.

Emrich, William J., Jr.↗