Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector and experiment monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Monitoring Methods for Early Detection of Inadvertent Fission Product Release at the Advanced Test Reactor

Isotope effluent data obtained during three instances of experiment failures at the Advanced Test Reactor (ATR) are analyzed to provide an overview of the methods used to detect initial signs of unintended fission product release. The data is contextualized with the operational experience, including means of identification and subsequent mitigation strategies, gained during these events. General trends as well as variations in isotopic behavior between the three failures are explored. Background on the Real Time Monitor, a High Purity Germanium detector, and other fission product monitoring systems utilized at the Advanced Test Reactor is also provided. The presented analysis was used to establish administrative action levels which are currently utilized by ATR for early detection of experiment fission product release. Early identification provides time to make programmatic decisions before approaching safety and environmental limits.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

The total and spectral solar irradiance and its possible variations

The present status of knowledge of the total and spectral irradiance of the sun is briefly reviewed. Currently accepted values of the solar constant and the extraterrestrial solar spectral irradiance are presented along with a discussion of how they were derived. Data on the variability of the solar constant are shown to be conflicting and inconclusive. Some of the alleged sun-weather relationships are cited in support of the need of knowing more precisely the variations in total and spectral solar irradiance. An overview of a solar monitoring program is discussed, with special emphasis on the Solar Energy Monitor in Space experiment which was proposed for several spacecraft missions. It is a combination of a solar constant detector and a prism monochromator. The determination of absolute values and the possible variations of the total and spectral solar irradiance, from measurements outside of the atmosphere is discussed.

Thekaekara, M. P.↗

Solar irradiance - Total and spectral and its possible variations

The present status of our knowledge of the total and spectral irradiance of the sun is briefly reviewed. The currently accepted NASA/ASTM standard values of the solar constant and the extraterrestrial solar spectral irradiance are presented. The uncertainties in these values are relatively high. Data on the variability of the solar constant are conflicting and inconclusive. The variability of solar spectral irradiance is almost totally unknown and unexplored. Some alleged sun-weather relationships are cited in support of the need to know more precisely the variations in total and spectral solar irradiance. An overview of the solar monitoring program of NASA is presented, with special emphasis on the Solar Energy Monitor in Space (SEMIS) experiment which has been proposed for several spacecraft missions. The monitor is a combination of a solar-constant detector and a prism monochromator.

Thekaekara, M. P.↗

Energetic particle flux experiment (IMP-F and G)

The technical aspects of the University of California IMP-F experiment aboard the Explorer-34 and the University of California IMP-G (S1) and (S2) experiments aboard the Explorer-41. The experiment detectors and electronics are discussed for each experiment as well as the fabrication, preflight and post-flight history. A description of the ground support equipment is also given for each experiment. These three experiments were essentially all different. The IMP-G experiment was essentially the IMP-F experiment with the addition of four Geiger-Mueller detectors. The IMP-G (S-2) was a supplementary experiment and differed completely from the IMP-F and IMP-G experiments. It was concluded that the ground support equipment approach used for the IMP-F and IMP-G experiments where emphasis was placed on a thorough exercise and monitoring of the experiment operation during various testing phases provided a high degree of confidence and reliability in these experiments. No known electronic failures have occurred during the spacecraft lifetime although some detector problems were experienced.

Anderson, K. A.↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Purity monitoring for ProtoDUNE

The next-generation neutrino experiment, DUNE, will utilize a high-intensity neutrino beam produced to measure electron-neutrino appearance and muon-neutrino disappearance with its 40 kilotons (fiducial mass) liquid argon far detector. Liquid argon purity is crucial to use liquid argon time projection chambers (LArTPC) in DUNE’s large detectors. A purity monitor is a miniature TPC that measures the lifetime of photoelectrons generated by its UV-illuminated gold photocathode to measure the purity of liquid argon. ProtoDUNEs are full-scale DUNE prototype LArTPCs built at CERNand perform beam tests. The following will discuss the design, implementation, and results of liquid argon purity monitors deployed in ProtoDUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Burst and Transient Source Experiment for the Gamma-Ray Observatory

The Burst and Transient Source Experiment (BATSE) is a highly sensitive, all-sky monitor for the Gamma-Ray Observatory (GRO). The eight scintillation detector modules of BATSE are positioned around the GRO spacecraft to provide a uniform view of the entire sky above the horizon. Each module is 20 in. in diameter, 0.5 in. thick and operates in the energy range from 40 to 600 keV. Rough burst locations can be derived from the relative counting rates of the detectors; longer-lived (greater than 100 min) transient sources can be detected and located by earth occultations. The data system contains mass memory to allow storage of large amounts of burst data in short time intervals. Data are sorted onboard in various ways into programmable energy, time and detector domains. Details of the design and capabilities of the BATSE are presented.

Fishman, G. J.↗

Intense Gamma-Ray Flashes Above Thunderstorms on the Earth and Other Planets

Intense millisecond flashes of MeV photons have been observed with space-borne detectors in Earth orbit. They are expected to be present on other planets that exhibit lightning. The terrestrial gamma-ray flashes (TGFs) were discovered with the Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma-Ray Observatory (CGRO) in the early 1990s. They are now being observed with several other instruments, including the Gamma-ray Burst Monitor (GBM) detectors on the Fermi Gamma-ray Space Telescope. Although Fermi- GBM was designed and optimized for the observation of cosmic gamma-ray bursts (GRBs), it has unprecedented capabilities for TGF observations. The TGFs usually have extremely hard continuous spectra, typical of highly- Comptonized bremsstrahlung radiation. These spectral are harder than those of GRBs, with photons extending to over 40 MeV. The most likely origin of these high-energy photons is bremsstrahlung radiation produced by a relativistic "runaway avalanche" electron beam. Such a beam is expected to be produced in an extended, intense electric field in or above thunderstorm regions. The altitude of origin and beaming characteristics of the radiation are quite uncertain. They have generated considerable observational and theoretical interest in recent years. This talk will give an overview of the all of the space-borne observations of TGFs that have been made thus far. Instruments are being designed specifically for TGF observations from new spacecraft as well as from airborne platforms

Fishman, Gerald J.↗

An Overview of MODIS Calibration and Characterization

The MODerate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments for the NASA s Earth Observing System (EOS). It is currently operating on both EOS Terra and Aqua satellites. The MODIS is a major advance over its heritage sensors in terms of its spectral, spatial, and temporal resolutions with frequent global observations and a broad range of science applications. There are 20 reflective solar bands (RSB) with center wavelengths ranging from 0.41 to 2.l microns and 16 thermal emissive bands (TEB) from 3.7 to 14.4 microns. The absolute radiometric accuracy requirements (lsigma) at the typical spectral radiance levels are plus or minus 2% for the RSB reflectance factors and plus or minus 5% for the RSB radiance products. With few exceptions, the TEB requirements are plus or minus 1%. To verify that the instruments met their specified design requirements both Terra and Aqua MODIS underwent extensive pre-launch calibration and characterization at various levels, including system-level thermal vacuum testing. On-orbit calibration and characterization are performed by the on-board calibrators: a solar diffuser (SD) and a solar diffuser stability monitor (SDSM), a V-groove flat panel blackbody (BB), and a spectro-radiometric calibration assembly (SRCA). In this paper, we present an overview of MODIS calibration and characterization activities, methodologies, and lessons learned from pre-launch testing and on-orbit operations. Key issues to be discussed include our on-orbit efforts of monitoring detectors noise characterization, tracking solar diffuser and optics degradation, and updating sensor s response versus scan-angle. The MODIS experience has provided invaluable lessons that are being used in designing and testing the Visible Infrared Imaging Radiometer Suite (VIIRS), a direct follow-on to the MODIS that will be flown on the National Polar-Orbit Operational Environmental Satellite System (NPOESS) missions.

Xiong, X.↗

Wave-particle interactions induced by SEPAC on Spacelab 1 Wave observations

Space experiments with particle accelerators (SEPAC) flew on Spacelab 1 in November and December 1983. SEPAC included an accelerator which emitted electrons into the ionospheric plasma with energies up to 5 keV and currents up to 300 mA. The SEPAC equipment also included an energetic plasma generator, a neutral gas generator, and an extensive array of diagnostics. The diagnostics included plasma wave detectors, and energetic electron analyzer, a photometer, a high sensitivity television camera, a Langmuir probe and a pressure gage. Twenty-eight experiments were performed during the mission to investigate beam-plasma interactions, electron beam dynamics, plasma beam propagation, and vehicle charging. The wave-particle interactions were monitored by the plasma wave instrumentation, by the energetic electron detector and by the optical detectors. All show evidence of wave-particle interactions, which are described in this paper.

Taylor, W. W. L.↗

The Helios A/B cosmic ray instrument /E 7/

This paper describes the design and performance of a cosmic ray particle experiment for the Helios A/B space missions. This experiment had to be very lightweight, low power and electronically sophisticated in order to meet the spacecraft and scientific requirements, and very similar to those on the Pioneer 10 and 11 missions to Jupiter. Both sets of missions use several solid-state detector telescopes to measure protons from 100 KeV to 800 MeV per nucleon. Additionally, the Helios experiment includes a proportional counter to monitor the solar X-ray activity. The experiment has functioned quite well for 5 months in space, and large quantities of data are now being received.

Trainor, J. H.↗

Observing orbital debris using space-based telescopes. I - Mission orbit considerations

In this paper, mission orbit considerations are addressed for using the Space Shuttle as a telescope platform for observing man-made orbital debris. Computer modeling of various electrooptical systems predicts that such a space-borne system will be able to detect particles as small as 1-mm diameter. The research is meant to support the development of debris- collision warning sensors through the acquisition of spatial distribution and spectral characteristics for debris and testing of detector combinations on a shuttle-borne telescopic experiment. The technique can also be applied to low-earth-orbit-debris environment monitoring systems. It is shown how the choice of mission orbit, season of launch, and time of day of launch may be employed to provide extended periods of favorable observing conditions.

Reynolds, Robert C.↗

Developing Low Noise, Rad-hard Detectors for Parity Violating Experiments

As parity-violating electron scattering (PVeS) experiments continue to push the frontiers of precision electro-weak asymmetry measurements, the demands on the experimental techniques and apparatus are also pushed. In particular, the need for higher resolution and radiation-hardness of the main integrating detectors has increased over the successive generations of PVeS experiments. The demand for precise measurement of GHz event rates has pushed the field toward the use of thin quartz Cerenkov light based detectors. We have been designing and testing such thin quartz detectors specifically for the upcoming experiments at Jefferson Lab, PREX-II and CREX, but this work also greatly influences the detector development for several future experiments including MOLLER at Jefferson Lab. These are all PVeS experiments that will use the new thin quartz Cerenkov detector design concept for their main asymmetry measurements (as well as for beam monitoring). The new design concept gives not only significant performance improvements compared to its predecessor from PREX-I, but also we have now thoroughly characterized its operational design and performance using a combination of test-beam data and detailed particle and optical Monte Carlo Geant4 simulations. These activities have culminated in the development and implementation of a "bench-marked" Monte Carlo package, QSIM, which constitutes a powerful design tool for present and future PVeS quartz detectors. The benchmarked simulation can replicate real photoelectron distributions (RMS and Mean) from testbeam data with ~5% precision – limited mainly by the systematic uncertainty of the PMT gain measurements.

Villarreal, Carlos Bula Villarreal↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗

CELIAS: Charge, Element and Isotope Analysis System for the SOHO mission

The status and further development as well as first calibration of the CELIAS experiment on SOHO is presented. CELIAS is designed to measure the mass, ionic charge, and energy of low and high speed solar wind of suprathermal ions and of low energy flare particles. Through analysis of the elemental and isotopic abundances (the ionic charge state and velocity distributions of ions originating on the solar atmosphere), the investigation focuses on studying the plasma processes in various temporal and spatial scales in the solar chromosphere, transition zone, and corona. Additionally, the CELIAS experiment includes the Solar EUV Monitor (SEM). This unit, which consists of an EUV transmission grating spectrometer and three isolated silicon photodiodes as detectors, is described. The three mass and charge discriminating sensors based on the time of flight technique are also described.

Hovestadt, D.↗

Performance of the large-area detectors for the Burst and Transient Source Experiment (BATSE) on the Gamma Ray Observatory

BATSE, one of four experiments on the Gamma Ray Observatory (GRO), is expected to provide the most sensitive observations of gamma-ray bursts yet obtained, as well as to provide long-term monitoring of hard X-ray and low-energy gamma-ray emission from bright pulsating sources, transients, and solar flares. Eight uncollimated modules, positioned at the corners of the spacecraft to provide an unobstructed view of the sky, detect sources by various techniques based on time variability. Use of detectors with anisotropic response allows location of gamma-ray bursts to be determined to an accuracy of about 1 deg using BATSE data alone. The completed BATSE underwent intensive testing and calibration prior to its delivery in October 1988.

Paciesas, W. S.↗

Current pyrheliometry for total solar irradiance observations

A Type IV active cavity radiometer (ACR IV) was developed at JPL in 1975-76 as part of the NASA Weather and Climate Program. It is capable of defining the absolute radiation scale with an uncertainty near 0.1% and a resolution of 0.02% at the nominal solar 'constant' level. The ACR IV is the first pyrheliometer capable of measurements at the 0.1% level, which is the threshold of solar 'constant' variability of significance for climatological modeling. A prototype has been tested, and a flight instrument was flown in a 1976 sounding rocket experiment which determined a solar 'constant' value of 1368 W/sq m. A three-detector version of the ACR IV is being developed to monitor the solar 'constant' during 1979-80 as part of NASA's Solar Maximum Mission. Another ACR IV will measure the solar 'constant' as part of the Spacelab I mission in 1980.

Willson, R. C.↗

Environmental Radiation Measurements on the Mir Space Station: Internal Experiment Program - Program 1

As part of the NASA/Mir Phase 1B Science Program, the ionizing radiation environment inside and outside the Russian Mir's Space Station was monitored using a combination of Thermoluminescent Detectors (TLD) and CR-39 Plastic Nuclear Track Detectors (PNTD). Radiation measurements inside the Mir station were carried out using six Area Passive Dosimeters (APD), four located inside the Mir Base Block and two located inside the Kvant 2 module, during the NASA-2/Mir-21, NASA-3/Mir-22 and NASA-4/Mir-23 missions. The radiation environment under low shielding was measured using an External Dosimeter Array (EDA) mounted on the outer surface of the Kvant 2 module. The external radiation environment and a location inside the Kvant 2 roughly corresponding to the location of the EDA were monitored for 130 days during the NASA- 4/Mir-23 and NASA-5/Mir-24 missions. Dose rates measured by APD TLDs ranged from 271 to 407 microGy/d during the NASA-2/Mir-21 mission, from 265 to 378 microGy/d during the NASA-3/Mir-22 mission, and from 287 to 421 microGy/d during the NASA-4/Mir-23 mission. APD PNTDs have been analyzed and LET spectra have been Cenerated for the five APDs exposed on the NASA-2/Mir-21 mission and for two APD PNTDs exposed on the NASA-3/Mir-22 mission. Dose equivalent rates on the NASA-2/Mir-21 mission ranged from 513 microSv/d in the Kvant 2 module to 710 microSv/d on the floor of the Base Block. Dose as a function of shielding depth in TLDs has been measured in the thin TLD stacks including in the EDA. EDA dose range from 72.5 Gy under 0.0146 g/sq cm to 0.093 Gy under 3.25 g/sq cm of shielding. Readout and analysis of the reaming PNTDs form the NASA-3/Mir-22 mission and PNTDs from the NASA-4/Mir-23 mission (including those from the EDA) is ongoing and will be completed during the final year of this experiment. Dose equivalent rates for the NASA-3/Mir-22 and NASA-4/Mir-23 APDs will then be determined and comparisons will be made with both model calculations and with results from similar measurements.