Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data amplification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Broadband radiometric measurements from GPS satellites reveal summertime Arctic Ocean Albedo decreases more rapidly than sea ice recedes

Abstract New measurements from the Arctic ± 40 days around the summer solstice show reflected sunlight from north of 80°N decreases 20–35%. Arctic sea ice coverage decreases 7–9% over this same time period (as reported by the NSIDC) implying Arctic sea ice albedo decreases in addition to the sea ice receding. Similar Antarctic measurements provide a baseline to which Arctic measurements are compared. The Antarctic reflected sunlight south of 80°S is up to 30% larger than the Arctic reflectance and is symmetric around the solstice implying constant Antarctic reflectivity. Arctic reflected sunlight 20 days after solstice is > 100W/m 2 less than Antarctic reflected sunlight. For perspective, this is enough heat to melt > 1 mm/hour of ice. This finding should be compared with climate models and in reanalysis data sets to further quantify sea ice albedo’s role in Arctic Amplification. The measurements were made with previously unpublished pixelated radiometers on Global Positioning System satellites from 2014 to 2019. The GPS orbits give each radiometer instantaneous and continuous views of 37% of the Earth, two daily full views of the Arctic and Antarctic. Furthermore, the GPS constellation gives full-time full-Earth coverage that may provide data that complements existing limited field of view instruments that provide a less synoptic Earth view.

54 ENVIRONMENTAL SCIENCES↗

Arctic amplification is caused by sea-ice loss under increasing CO 2

Warming in the Arctic has been much faster than the rest of the world in both observations and model simulations, a phenomenon known as the Arctic amplification (AA) whose cause is still under debate. By analyzing data and model simulations, here we show that large AA occurs only from October to April and only over areas with significant sea-ice loss. AA largely disappears when Arctic sea ice is fixed or melts away. Periods with larger AA are associated with larger sea-ice loss, and models with bigger sea-ice loss produce larger AA. Increased outgoing longwave radiation and heat fluxes from the newly opened waters cause AA, whereas all other processes can only indirectly contribute to AA by melting sea-ice. We conclude that sea-ice loss is necessary for the existence of large AA and that models need to simulate Arctic sea ice realistically in order to correctly simulate Arctic warming under increasing CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Memory effects in attenuation and amplification quantum processes

With increasing communication rates via quantum channels, memory effects become unavoidable whenever the use rate of the channel is comparable to the typical relaxation time of the channel environment. We introduce a model of a bosonic memory channel, describing correlated noise effects in quantum-optical processes via attenuating or amplifying media. To study such a channel model, we make use of a proper set of collective field variables, which allows us to unravel the memory effects, mapping the n-fold concatenation of the memory channel to a unitarily equivalent, direct product of n single-mode bosonic channels. We hence estimate the channel capacities by relying on known results for the memoryless setting. Our findings show that the model is characterized by two different regimes, in which the cross correlations induced by the noise among different channel uses are either exponentially enhanced or exponentially reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototypes of self-powered radiation detectors employing intrinsic high-energy current

Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm{sup 2} for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The chemoreceptor genes of the waterflea Daphnia pulex: many Grs but no Ors

Background: Chemoreception is vitally important for all animals, yet little is known about the genetics of chemoreception in aquatic organisms. The keystone species Daphnia pulex, a well known crustacean, is the first aquatic invertebrate to have its genome sequenced. This has allowed us the initial investigation of chemoreceptor genes in an aquatic invertebrate, and to begin the study of chemoreceptor evolution across the arthropod phylum. Results: We describe 58 Grs (gustatory receptors), belonging to the insect chemoreceptor superfamily, which were identified bioinformatically in the draft genome of the crustacean waterflea Daphnia pulex. No genes encoding proteins similar to the insect odorant receptors (Ors) were identified. These 58 Grs form 3 distinctive subfamilies of 37, 12, and 5 genes, as well as a highly divergent singleton (Gr58). In addition, Grs55–57 share distinctive amino acid motifs and cluster with the sugar receptors of insects, and may illuminate the origin of this distinctive subfamily. ESTs, tiling array, and PCR amplification results support 34 predicted gene models, and preliminary expression data comparing the sexes indicates potential female-biased expression for some genes. Conclusion: This repertoire of 58 chemoreceptors presumably mediates the many chemoperception abilities of waterfleas. While it is always possible that the entire Or gene lineage was lost at some point in the history of Daphnia pulex, we think it more likely that the insect Or lineage is indeed a relatively recently expanded gene lineage concomitant with the evolution of terrestriality in the insects or their hexapod ancestors.

59 BASIC BIOLOGICAL SCIENCES↗

Frequency mixer having ferromagnetic film

A frequency conversion device, which may include a radiofrequency (RF) mixer device, includes a substrate and a ferromagnetic film disposed over a surface of the substrate. An insulator is disposed over the ferromagnetic film and at least one microstrip antenna is disposed over the insulator. The ferromagnetic film provides a non-linear response to the frequency conversion device. The frequency conversion device may be used for signal mixing and amplification. The frequency conversion device may also be used in data encryption applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Asymmetric error field interaction with rotating conducting walls

The interaction of error fields with a system of differentially rotating conducting walls is studied analytically and compared to experimental data. Wall rotation causes eddy currents to persist indefinitely, attenuating and rotating the original error field. Superposition of error fields from external coils and plasma currents are found to break the symmetry in wall rotation direction. The vacuum and plasma eigenmodes are modified by wall rotation, with the error field penetration time decreased and the kink instability stabilized, respectively. Wall rotation is also predicted to reduce error field amplification by the marginally stable plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and optimization of single-pass laser amplifiers for high-repetition-rate laser pulses

We propose a model for a continuously pumped single-pass amplifier for continuous and pulsed laser beams. The model takes into account Gaussian shape and focusing geometry of pump and seed beam. As the full-wave simulation is complex we have developed a largely simplified numerical method that can be applied to rotationally symmetric geometries. With the tapered-shell model we treat (focused) propagation and amplification of an initially Gaussian beam in a gain crystal. The implementation can be done with a few lines of code that are given in this paper. With this code, a numerical parameter optimization is straightforward and example results are shown. We compare the results of our simple model with those of a full-wave simulation and show that they agree well. A comparison of model and experimental data also shows good agreement. We investigate in detail different regimes of amplification, namely the unsaturated, the fully saturated, and the intermediate regime. Because the amplification process is affected by spatially varying saturation and exhibits a nonlinear response against pump and seed power, no analytical expression for the expected output is available. For modeling of the amplification we employ a four-level system and show that if the fluorescence lifetime of the gain medium is larger than the inverse repetition rate of the seed beam, continuous-wave amplification can be employed to describe the amplification process of ultrashort pulse trains. We limit ourselves to this regime, which implies that if titanium:sapphire is chosen as gain medium the laser repetition rate has to be larger than a few megahertz. We show detailed simulation results for titanium:sapphire for a large parameter set.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The electronics, trigger and data acquisition system for the liquid argon time projection chamber of the DarkSide-50 search for dark matter

The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.

Agnes, P.↗

Kähler moduli double inflation

We show that double inflation is naturally realized in Kähler moduli inflation, which is caused by moduli associated with string compactification. We find that there is a small coupling between the two inflatons which leads to amplification of perturbations through parametric resonance in the intermediate stage of double inflation. This results in the appearance of a peak in the power spectrum of the primordial curvature perturbation. We numerically calculate the power spectrum and show that the power spectrum can have a peak on observationally interesing scales. We also compute the TT-spectrum of CMB based on the power spectrum with a peak and see that it better fits WMAP 7-years data.

79 ASTRONOMY AND ASTROPHYSICS↗

Relaxation of spheromak configurations with open flux

The relaxation of several kink unstable equilibria with open flux representative of spheromaks sustained by dc helicity injection is studied by means of three-dimensional, resistive magnetohydrodynamic simulations. No external driving is applied, but the initial conditions are chosen to reproduce the current profiles existing in a gun driven spheromak, which has a high current density in the open flux region and a low current density in the closed flux region. The growth and nonlinear saturation of various unstable modes, the dynamo action which converts toroidal flux into poloidal flux, and the evolution of the {lambda} profile ({lambda}={mu}{sub 0}J{center_dot}B/B{sup 2}) are studied. An initial condition is found which results in a dynamo that produces enough poloidal flux to compensate the resistive losses occurred during a characteristic time of the instability. The flux amplification factor around which this case oscillates is consistent with existing experimental data. During the relaxation, the central open flux tube develops a helical distortion and the closed flux surfaces are destroyed. After the relaxation event, close flux surfaces form again but the final profiles are not fully relaxed and the central open flux tube remains distorted. The effect of the Lundquist number on the evolution and its impact on the required level of fluctuations are evaluated. Finally, the dynamics of the system for different current levels in the open flux region is studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Evidence of Short Light Pulse Amplification Using Strong-Coupling Stimulated Brillouin Scattering in the Pump Depletion Regime

The energy transfer from a long (3.5 ps) pump pulse to a short (400 fs) seed pulse due to stimulated Brillouin backscattering in the strong-coupling regime is investigated. The two pulses, both at the same wavelength of 1.057 {mu}m are quasicounterpropagating in a preformed underdense plasma. Relative amplification factors for the seed pulse of up to 32 are obtained. The maximum obtained amplified energy is 60 mJ. Simulations are in agreement with the experimental results and suggest paths for further improvement of the amplification scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2018 Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated two Kinemetrics Q330M+ digitizers. The digitizers are intended to record sensor output for seismic and infrasound monitoring applications. Notable improvements to the Q330M+ include the support for transmission and authentication of CD1.1 data, integration of analog and digital weather stations, support for multiple gain amplification levels, and the use of a webpage for status and configuration of the digitizer. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Hot-spot model for inertial confinement fusion implosions with an applied magnetic field

Imposing a magnetic field on inertial confinement fusion implosions magnetizes the electrons in the compressed fuel; this suppresses thermal losses, which increases temperature and fusion yield. Indirect-drive experiments at the National Ignition Facility with 12 and 26 T applied magnetic fields demonstrate up to 40% increase in temperature, 3× increase in fusion yield, and indicate that magnetization alters the radial temperature profile [Moody et al., Phys. Rev. Lett. 129, 195002 (2022); Lahmann et al., APS DPP (2022)]. In this work, we develop a semi-analytic hot-spot model, which accounts for the two-dimensional (2D) Braginskii anisotropic heat flow due to an applied axial magnetic field. First, we show that hot-spot magnetization alters the radial temperature profile, increasing the central peakedness, which is most pronounced for moderately magnetized implosions (with 8–14 T applied field), compared to both unmagnetized (with no applied field) and highly magnetized (with 26 T or higher applied field) implosions. This model explains the trend in the experimental data, which finds a similarly altered temperature profile in the 12 T experiment. Next, we derive the hot-spot model for gas-filled (Symcap) implosions, accounting for the effects of magnetization on the thermal conduction and in changing the radial temperature (and density) profiles. Using this model, we compute predicted central temperature amplification and yield enhancement scaling with the applied magnetic field. The central temperature fits the experimental data accurately, and the discrepancy in the yield suggests a systematic (independent of applied field) degradation, such as mix, and additional degradation in the reference unmagnetized shot, such as reduced laser drive, increased implosion asymmetry, or the magnetic field suppressing ablator mixing into the hot-spot.

Alpha particles↗

Multi-omics approach to infer cancer therapeutic targets on chromosome 20q across tumor types

The identification of good targets is a critical step for the development of targeted therapies for cancer treatment. Here, we used a multi-omics approach to delineate potential targets on chromosome 20q, which frequently shows a complex pattern of DNA copy number amplification in many human cancers suggesting the presence of multiple driver genes. By comparing the amounts of individual mRNAs in cancer from 11 different human tissues with those in their corresponding normal tissues, we identified 18 genes that were robustly elevated across human cancers. Moreover, we found that higher expression levels of a majority of these genes were associated with poor prognosis in many human cancer types. Using DNA copy number and expression data for all 18 genes obtained from The Cancer Genome Atlas project, we discovered that amplification is a major mechanism driving overexpression of these 18 genes in the majority of human cancers. Our integrated analysis suggests that 18 genes on chromosome 20q might serve as novel potential molecular targets for targeted cancer therapy.

60 APPLIED LIFE SCIENCES↗

Parametrically amplified Josephson plasma waves in YBa 2 Cu 3 O 6+ x : Evidence for local superconducting fluctuations up to the pseudogap temperature T ∗

Experiments that subject underdoped YBa 2 Cu 3 O 6+x (YBCO) to intense terahertz pulses at temperatures between the transition temperature T c and the pseudogap scale T ∗ have revealed a reflectivity edge that resembles that of the superconducting state, together with second harmonic generation of a probe pulse modulated at a similar frequency. These have been interpreted in terms of parametric amplification of the lower Josephson plasmon mode. Since this mode is often associated with coherent oscillations between bilayers in the YBCO structure, these experiments have led to the suggestion that the intense pump has created (or revealed) in-plane pair coherence up to T ∗ ≈ 400 K. In this paper we propose an alternative explanation by assuming the existence of local pair amplitude and phase at equilibrium for T c < T < T ∗ . The phase correlation spans only a few lattice constants and we do not assume any pump-induced enhancement of this correlation, either in-plane or between bilayers. Instead, the coherent drive, via a parametric amplification process, induces coherence in the Josephson currents between members of bilayers. When combined with a Floquet framework, the reflectivity data can be explained. The key point is that in the lower Josephson plasmon, the coupling between bilayers is mainly capacitive; the Josephson current between bilayers can be set to zero without strongly affecting the parametric amplification process. Importantly, while superconducting coherence may not be created by the pump, the pseudogap phase must possess a local pairing amplitude at equilibrium. Consequently, these experiments have strong implications for the understanding of the pseudogap phase.

parametric amplification↗

Direct optical measurement of the on-shot incoherent focal spot and intensity contrast on the OMEGA EP laser

Characterizing the prepulse temporal contrast of optical pulses is required to understand their interaction with matter. Light with relatively low intensity can interact with the target before the main high-intensity pulse. Estimating the intensity contrast, instead of the spatially averaged power contrast, is important to understand intensity-dependent laser–matter interactions. A direct optical approach to determining the on-shot intensity of the incoherent pedestal on an aberrated high-intensity laser system is presented. The spatially resolved focal spot of the incoherent pedestal preceding the main coherent pulse and the intensity contrast are calculated using experimental data. Furthermore, this technique is experimentally validated on one of the chirped pulse amplification beamlines of the OMEGA EP Laser System. The intensity contrast of a 1-kJ, 10-ps laser pulse is shown to be ~10× higher than the power contrast because of the larger spatial extent of the incoherent focal spot relative to the coherent focal spot.

47 OTHER INSTRUMENTATION↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗