Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dark fiber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Semi-analytical covariance matrices for two-point correlation function for DESI 2024 data

We present an optimized way of producing the fast semi-analytical covariance matrices for the Legendre moments of the two-point correlation function, taking into account survey geometry and mimicking the non-Gaussian effects. We validate the approach on simulated (mock) catalogs for different galaxy types, representative of the Dark Energy Spectroscopic Instrument (DESI) Data Release 1, used in 2024 analyses. We find only a few percent differences between the mock sample covariance matrix and our results, which can be expected given the approximate nature of the mocks, although we do identify discrepancies between the shot-noise properties of the DESI fiber assignment algorithm and the faster approximation (emulator) used in the mocks. Importantly, we find a close agreement (≤ 8% relative differences) in the projected errorbars for distance scale parameters for the baryon acoustic oscillation measurements. This confirms our method as an attractive alternative to simulation-based covariance matrices, especially for non-standard models or galaxy sample selections, making it particularly relevant to the broad current and future analyses of DESI data.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing the 10 spectrograph units for DESI: approach and results

The recently commissioned Dark Energy Spectroscopic Instrument (DESI) will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sqdeg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope delivers light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. A consortium of Aix-Marseille University (AMU) and CNRS laboratories (LAM, OHP and CPPM) together with LPNHE (CNRS, IN2P3, Sorbonne Université and Université de Paris) and the WINLIGHT Systems company based in Pertuis (France), were in charge of integrating and validating the performance requirements of the ten full spectrographs, equipped with their cryostats, shutters and other mechanisms. We present a summary of our activity which allowed an efficient validation of the systems in a short-time schedule. We detail the main results. We emphasize the benefits of our approach and also its limitations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HETDEX Public Source Catalog 1: 220 K Sources Including Over 50 K Ly$α$ Emitters from an Untargeted Wide-area Spectroscopic Survey*

We present the first publicly released catalog of sources obtained from the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX). HETDEX is an integral field spectroscopic survey designed to measure the Hubble expansion parameter and angular diameter distance at 1.88 < z < 3.52 by using the spatial distribution of more than a million Lyα-emitting galaxies over a total target area of 540 deg 2 . The catalog comes from contiguous fiber spectra coverage of 25 deg 2 of sky from 2017 January through 2020 June, where object detection is performed through two complementary detection methods: one designed to search for line emission and the other a search for continuum emission. The HETDEX public release catalog is dominated by emission-line galaxies and includes 51,863 Ly$α$-emitting galaxy (LAE) identifications and 123,891 [O ii]-emitting galaxies at z < 0.5. Also included in the catalog are 37,916 stars, 5274 low-redshift (z < 0.5) galaxies without emission lines, and 4976 active galactic nuclei. The catalog provides sky coordinates, redshifts, line identifications, classification information, line fluxes, [O ii] and Ly$α$ line luminosities where applicable, and spectra for all identified sources processed by the HETDEX detection pipeline. Extensive testing demonstrates that HETDEX redshifts agree to within Δz < 0.02, 96.1% of the time to those in external spectroscopic catalogs. We measure the photometric counterpart fraction in deep ancillary Hyper Suprime-Cam imaging and find that only 55.5% of the LAE sample has an r-band continuum counterpart down to a limiting magnitude of r ~ 26.2 mag (AB) indicating that an LAE search of similar sensitivity to HETDEX with photometric preselection would miss nearly half of the HETDEX LAE catalog sample. Data access and details about the catalog can be found online at http://hetdex.org/. A copy of the catalogs presented in this work (Version 3.2) is available to download at Zenodo doi:10.5281/zenodo.7448504.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Vacuum Nuller Testbed Performance, Characterization and Null Control

The Visible Nulling Coronagraph (VNC) can detect and characterize exoplanets with filled, segmented and sparse aperture telescopes, thereby spanning the choice of future internal coronagraph exoplanet missions. NASA/Goddard Space Flight Center (GSFC) has developed a Vacuum Nuller Testbed (VNT) to advance this approach, and assess and advance technologies needed to realize a VNC as a flight instrument. The VNT is an ultra-stable testbed operating at 15 Hz in vacuum. It consists of a MachZehnder nulling interferometer; modified with a "W" configuration to accommodate a hexpacked MEMS based deformable mirror (DM), coherent fiber bundle and achromatic phase shifters. The 2-output channels are imaged with a vacuum photon counting camera and conventional camera. Error-sensing and feedback to DM and delay line with control algorithms are implemented in a real-time architecture. The inherent advantage of the VNC is that it is its own interferometer and directly controls its errors by exploiting images from bright and dark channels simultaneously. Conservation of energy requires the sum total of the photon counts be conserved independent of the VNC state. Thus sensing and control bandwidth is limited by the target stars throughput, with the net effect that the higher bandwidth offloads stressing stability tolerances within the telescope. We report our recent progress with the VNT towards achieving an incremental sequence of contrast milestones of 10(exp 8) , 10(exp 9) and 10(exp 10) respectively at inner working angles approaching 2A/D. Discussed will be the optics, lab results, technologies, and null control. Shown will be evidence that the milestones have been achieved.

Lyon, R. G.↗

Production of alternate realizations of DESI fiber assignment for unbiased clustering measurement in data and simulations

A critical requirement of spectroscopic large scale structure analyses is correcting for selection of which galaxies to observe from an isotropic target list. This selection is often limited by the hardware used to perform the survey which will impose angular constraints of simultaneously observable targets, requiring multiple passes to observe all of them. In SDSS this manifested solely as the collision of physical fibers and plugs placed in plates. In DESI, there is the additional constraint of the robotic positioner which controls each fiber being limited to a finite patrol radius. A number of approximate methods have previously been proposed to correct the galaxy clustering statistics for these effects, but these generally fail on small scales. To accurately correct the clustering we need to upweight pairs of galaxies based on the inverse probability that those pairs would be observed (Bianchi & Percival 2017). This paper details an implementation of that method to correct the Dark Energy Spectroscopic Instrument (DESI) survey for incompleteness. To calculate the required probabilities, we need a set of alternate realizations of DESI where we vary the relative priority of otherwise identical targets. These realizations take the form of alternate Merged Target Ledgers (AMTL), the files that link DESI observations and targets. We present the method used to generate these alternate realizations and how they are tracked forward in time using the real observational record and hardware status, propagating the survey as though the alternate orderings had been adopted. We detail the first applications of this method to the DESI One-Percent Survey (SV3) and the DESI year 1 data. We include evaluations of the pipeline outputs, estimation of survey completeness from this and other methods, and validation of the method using mock galaxy catalogs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

The Spectroscopic Data Processing Pipeline for the Dark Energy Spectroscopic Instrument

Abstract We describe the spectroscopic data processing pipeline of the Dark Energy Spectroscopic Instrument (DESI), which is conducting a redshift survey of about 40 million galaxies and quasars using a purpose-built instrument on the 4 m Mayall Telescope at Kitt Peak National Observatory. The main goal of DESI is to measure with unprecedented precision the expansion history of the universe with the baryon acoustic oscillation technique and the growth rate of structure with redshift space distortions. Ten spectrographs with three cameras each disperse the light from 5000 fibers onto 30 CCDs, covering the near-UV to near-infrared (3600–9800 Å) with a spectral resolution ranging from 2000 to 5000. The DESI data pipeline generates wavelength- and flux-calibrated spectra of all the targets, along with spectroscopic classifications and redshift measurements. Fully processed data from each night are typically available to the DESI collaboration the following morning. We give details about the pipeline’s algorithms, and provide performance results on the stability of the optics, the quality of the sky background subtraction, and the precision and accuracy of the instrumental calibration. This pipeline has been used to process the DESI Survey Validation data set, and has exceeded the project’s requirements for redshift performance, with high efficiency and a purity greater than 99% for all target classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of the Instrumentation for the Dark Energy Spectroscopic Instrument

Abstract The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii ] doublet at 8 × 10 −17 erg s −1 cm −2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near field excited state imaging via stimulated electron energy gain spectroscopy of localized surface plasmon resonances in plasmonic nanorod antennas

Continuous wave (cw) photon stimulated electron energy loss and gain spectroscopy (sEELS and sEEGS) is used to image the near field of optically stimulated localized surface plasmon resonance (LSPR) modes in nanorod antennas. An optical delivery system equipped with a nanomanipulator and a fiber-coupled laser diode is used to simultaneously irradiate plasmonic nanostructures in a (scanning) transmission electron microscope. The nanorod length is varied such that the m = 1, 2, and 3 LSPR modes are resonant with the laser energy and the optically stimulated near field spectra and images of these modes are measured. Various nanorod orientations are also investigated to explore retardation effects. Optical and electron beam simulations are used to rationalize the observed patterns. As expected, the odd modes are optically bright and result in observed sEEG responses. The m = 2 dark mode does not produce a sEEG response, however, when tilted such that retardation effects are operative, the sEEG signal emerges. Thus, we demonstrate that cw sEEGS is an effective tool in imaging the near field of the full set of nanorod plasmon modes of either parity.

36 MATERIALS SCIENCE↗

Waveform analysis of a large-area superconducting nanowire single photon detector

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum communications. However, the long meander-line length of such large-area SNSPDs results in a proportionately large kinetic inductance that affects the waveform generated by the device. Here, we explore changes in the rising edge of the readout pulse for a single-pixel large-area SNSPD as a function of the optical spot size on the detector and compare to the rising edge of the dark-count waveform. We observe a bimodal distribution of bright-count rise times and show that the probability of a slow rise time increases in the limit of large spot sizes, indicative of a position sensitive response. Additionally, in the limit of low bias currents, the dark-count readout pulse is most similar to the large spot-size bright-count readout pulse, which suggests that dark counts arise from locations spanning the device. Overall, these results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CALET Results After Three Years on Orbit on the International Space Station

The CALorimetric Electron Telescope (CALET) is an astroparticle physics experiment installed on the International Space Station since August 2015. The CALET mission was conceived to address several outstanding questions of high-energy astroparticle physics, like indirect detection of dark matter, the origin of cosmic rays (CRs), their mechanisms of acceleration and galactic propagation, the presence of possible nearby astrophysical CR sources. That can be achieved by precise measurements of the fluxes of CR electrons and gamma-rays up to the unexplored region above 1 TeV, and the energy spectra and composition of CR nuclei from a few tens of GeV to hundreds of TeV. In order to perform these observations, the instrument combines a thick total absorption PWO crystal calorimeter for energy measurement, a scintillator hodoscope for charge identi cation and thin imaging tungsten-scintillating fiber calorimeter providing accurate particle tracking and complementary charge measurement. In this paper, we will present an overview of the main CALET results based on the data collected in the first three years of the mission.

P Maestro↗

Target Selection and Sample Characterization for the DESI LOW-Z Secondary Target Program

Abstract We introduce the DESI LOW- Z Secondary Target Survey, which combines the wide-area capabilities of the Dark Energy Spectroscopic Instrument (DESI) with an efficient, low-redshift target selection method. Our selection consists of a set of color and surface brightness cuts, combined with modern machine-learning methods, to target low-redshift dwarf galaxies ( z < 0.03) between 19 < r < 21 with high completeness. We employ a convolutional neural network (CNN) to select high-priority targets. The LOW- Z survey has already obtained over 22,000 redshifts of dwarf galaxies ( M * < 10 9 M ⊙ ), comparable to the number of dwarf galaxies discovered in the Sloan Digital Sky Survey DR8 and GAMA. As a spare fiber survey, LOW- Z currently receives fiber allocation for just ∼50% of its targets. However, we estimate that our selection is highly complete: for galaxies at z < 0.03 within our magnitude limits, we achieve better than 95% completeness with ∼1% efficiency using catalog-level photometric cuts. We also demonstrate that our CNN selections z < 0.03 galaxies from the photometric cuts subsample at least 10 times more efficiently while maintaining high completeness. The full 5 yr DESI program will expand the LOW- Z sample, densely mapping the low-redshift Universe, providing an unprecedented sample of dwarf galaxies, and providing critical information about how to pursue effective and efficient low-redshift surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

The HETDEX Instrumentation: Hobby–Eberly Telescope Wide-field Upgrade and VIRUS

The Hobby–Eberly Telescope (HET) Dark Energy Experiment (HETDEX) is undertaking a blind wide-field low-resolution spectroscopic survey of 540 deg 2 of sky to identify and derive redshifts for a million Ly α -emitting galaxies in the redshift range 1.9 < z < 3.5. The ultimate goal is to measure the expansion rate of the universe at this epoch, to sharply constrain cosmological parameters and thus the nature of dark energy. A major multiyear Wide-Field Upgrade (WFU) of the HET was completed in 2016 that substantially increased the field of view to 22' diameter and the pupil to 10 m, by replacing the optical corrector, tracker, and Prime Focus Instrument Package and by developing a new telescope control system. The new, wide-field HET now feeds the Visible Integral-field Replicable Unit Spectrograph (VIRUS), a new low-resolution integral-field spectrograph (LRS2), and the Habitable Zone Planet Finder, a precision near-infrared radial velocity spectrograph. VIRUS consists of 156 identical spectrographs fed by almost 35,000 fibers in 78 integral-field units arrayed at the focus of the upgraded HET. VIRUS operates in a bandpass of 3500–5500 Å with resolving power R ≃ 800. VIRUS is the first example of large-scale replication applied to instrumentation in optical astronomy to achieve spectroscopic surveys of very large areas of sky. This paper presents technical details of the HET WFU and VIRUS, as flowed down from the HETDEX science requirements, along with experience from commissioning this major telescope upgrade and the innovative instrumentation suite for HETDEX.

79 ASTRONOMY AND ASTROPHYSICS↗

Circadian force and EMG activity in hindlimb muscles of rhesus monkeys

Continuous intramuscular electromyograms (EMGs) were recorded from the soleus (Sol), medial gastrocnemius (MG), tibialis anterior (TA), and vastus lateralis (VL) muscles of Rhesus during normal cage activity throughout 24-h periods and also during treadmill locomotion. Daily levels of MG tendon force and EMG activity were obtained from five monkeys with partial datasets from three other animals. Activity levels correlated with the light-dark cycle with peak activities in most muscles occurring between 08:00 and 10:00. The lowest levels of activity generally occurred between 22:00 and 02:00. Daily EMG integrals ranged from 19 mV/s in one TA muscle to 3339 mV/s in one Sol muscle: average values were 1245 (Sol), 90 (MG), 65 (TA), and 209 (VL) mV/s. The average Sol EMG amplitude per 24-h period was 14 microV, compared with 246 microV for a short burst of locomotion. Mean EMG amplitudes for the Sol, MG, TA, and VL during active periods were 102, 18, 20, and 33 microV, respectively. EMG amplitudes that approximated recruitment of all fibers within a muscle occurred for 5-40 s/day in all muscles. The duration of daily activation was greatest in the Sol [151 +/- 45 (SE) min] and shortest in the TA (61 +/- 19 min). The results show that even a "postural" muscle such as the Sol was active for only approximately 9% of the day, whereas less active muscles were active for approximately 4% of the day. MG tendon forces were generally very low, consistent with the MG EMG data but occasionally reached levels close to estimates of the maximum force generating potential of the muscle. The Sol and TA activities were mutually exclusive, except at very low levels, suggesting very little coactivation of these antagonistic muscles. In contrast, the MG activity usually accompanied Sol activity suggesting that the MG was rarely used in the absence of Sol activation. The results clearly demonstrate a wide range of activation levels among muscles of the same animal as well as among different animals during normal cage activity.

NASA Discipline Musculoskeletal↗

Direct-detection Free-space Laser Transceiver Test-bed

NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.

Krainak, Michael A.↗

6 um Pulsed OP-GaAs OPO Laser for Unambiguous Water Ice Detection on the Moon and Other Planetary Bodies

NASA demands a laser transmitter for planetary remote sensing to detect water-ice on the Moon and other planetary bodies. Based on the measurement of the Moon Mineralogy Mapper (M3) instrument, the discovery of water ice on the Moon was acclaimed, but the measurement is disputed because OH- and/or H2O-bearing materials share the absorption line around 3 μm wavelength. Lunar Flashlight, another mission project exploring the surface of Moon which will be launched later this year, enables to map the minerals on dark area of the Moon, but could not resolve the above-mentioned ambiguity. The absorption of 6.08 μm light is uniquely associated with the bending resonance of H2O since there is no comparable vibration in confounding OH-bearing materials. 6.08 μm laser between the atmospheric windows: middle-wave infrared (3-5 μm) and long-wave infrared (8-12 μm) has not been commercially available. Our approach is a Q-switched Ho:YLF laser pumped the orientation-pattern Gallium Arsenide optical parametric oscillator (OP-GaAs OPO) for generating high-energy laser pulses at the wavelength of 6.08 μm. In the current design, a 1.94 μm Tm:fiber is used as the pump source. In the compact design, a 1.94 μm laser diode will replace the Tm:fiber laser as the pump source. We will combine this proposed mid-infrared laser with the latest HgCdTe avalanche photodiode (APD) array to design a lidar for detecting water ice on the Moon and Mars from their respective orbits, enabling novel science and in-situ resource utilization. Our instrument is an enabling technology aboard the Artemis program and others.

mid-infrared laser↗