Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “damping controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental investigation of advanced turbine control strategies and load-mitigation measures with a model-scale floating offshore wind turbine system

To advance the control co-design of offshore wind energy systems, the authors perform basin-scale experiments with a fully instrumented and actuated floating offshore wind turbine model. The model consists of a 1:70 scale performance-matched model of the International Energy Agency Wind Technology Collaboration Programme 15-MW reference turbine atop the VolturnUS-S semisubmersible platform. The Reference OpenSource Controller provides real-time blade pitch and generator torque control. Here we aim to develop an open data set for the validation of numerical models in predicting the influence of turbine control and load-mitigation measures. For this purpose, we measure the effects of advanced turbine control features, including peak shaving and floating feedback as well as hull-based control using tuned mass dampers on the system. Overall, the results demonstrate measurable and consistent influences from the control and load-mitigation measures, thus confirming the usefulness as a validation data set. Peak shaving attenuates the response to wind turbulence at near-rated wind speed. Floating feedback reduces the load and platform pitch motion associated with the negative damping induced by blade pitch control. The tuned mass dampers also attenuate the system response near the targeted frequencies under suitable conditions. We also identify detrimental side effects of each load-mitigation measure.

17 WIND ENERGY↗

Data-driven Optimal Control Strategy for Virtual Synchronous Generator via Deep Reinforcement Learning Approach

This paper aims at developing a data-driven optimal control strategy for virtual synchronous generator (VSG) in the scenario where no expert knowledge or requirement for system model is available. Firstly, the optimal and adaptive control problem for VSG is transformed into a reinforcement learning task. Specifically, the control variables, i.e., virtual inertia and damping factor, are defined as the actions. Meanwhile, the active power output, angular frequency and its derivative are considered as the observations. Moreover, the reward mechanism is designed based on three preset characteristic functions to quantify the control targets: (1) maintaining the deviation of angular frequency within special limits; (2) preserving well-damped oscillations for both the angular frequency and active power output; (3) obtaining slow frequency drop in the transient process. Next, to maximize the cumulative rewards, a decentralized deep policy gradient algorithm, which features model-free and faster convergence, is developed and employed to find the optimal control policy. With this effort, a data-driven adaptive VSG controller can be obtained. By using the proposed controller, the inverter-based distributed generator can adaptively adjust its control variables based on current observations to fulfill the expected targets in model-free fashion. Finally, simulation results validate the feasibility and effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust multi‐loop control of a floating wind turbine

Abstract A principal challenge facing the control of floating offshore wind turbines (FOWTs) is the problem of instability, or “negative damping,” when using blade pitch feedback to control generator speed. This closed‐loop instability can be attributed to non‐minimum phase zeros in the transfer function from blade pitch to generator speed. Standard approaches to improving stability and performance include robust tuning of control gains and introducing multiple feedback loops to respond to platform motion. Combining these approaches is nontrivial because multiple control loops complicate the impact of coupling in the system dynamics. The single‐loop approach to analyzing stability robustness neglects inter‐loop coupling, while a simplistic multi‐loop approach is highly sensitive to dimensional scaling and overestimates the robustness of the single‐loop controller. This work proposes a sensitivity representation that separates some of the natural FOWT dynamic coupling into a parallel feedback loop in the sensitivity function loop to address both of these concerns. The modified robustness measure is used with a simplified linear FOWT model to optimize scheduled multi‐loop control parameters in an automated tuning procedure. This controller is implemented for the 10‐MW Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) and compared against conventional single‐ and multi‐loop controllers tuned using frequency‐domain analysis and high‐fidelity OpenFAST simulations. The multi‐loop robust controller shows the highest overall performance in generator speed regulation and tower load reduction, though consideration of power quality, actuator usage, and other structural loading leads to additional trade‐offs.

Stockhouse, David↗

On the Stability of Power Transmission Systems Under Persistent Inverter Attacks: A Bi-Linear Matrix Approach

We investigate the stability and robustness properties of a power transmission system under persistent deceiving attacks on inverter-interfaced energy resources. The attacks can corrupt the damping coefficients in the inverters' controllers and measurements of the frequency at the points of coupling. Leveraging tools from hybrid dynamical systems theory, we characterize a broad family of persistent (and not necessarily periodic) attacks acting on the inverters, under which the stability properties of the transmission system can be shown to not be compromised. To address potentially conservative conditions identified through conventional bounding techniques, sufficient conditions on the average activation time of the attacks are identified via Lyapunov theory, as well as the formulation and solution of a class of bilinear matrix inequalities (BMI). The results are obtained for constant and slowly time-varying loads via input-to-state stability (ISS) tools. Numerical simulations on the IEEE 39-bus test system are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of wind turbine design parameters on linearized physics-based models in OpenFAST

Abstract. While most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear wind system equations is often important for understanding the system response and exploiting well-established methods and tools for analyzing linear systems. Linearized models are important for eigenanalysis (to derive structural natural frequencies, damping ratios, and mode shapes), controls design (based on linear state-space models), etc. In controls co-design, wherein methods often rely on linearized time-domain models of the physics, the physical structure (often called the plant) and controller are designed and optimized concurrently, so it is important to understand how changes to the physical design affect the linearized system. This work summarizes efforts done to understand the impact of design parameter variations in the physical system (e.g., mass, stiffness, geometry, and aerodynamic and hydrodynamic coefficients) on the linearized system using OpenFAST.

17 WIND ENERGY↗

Control of magnon–photon coupling by spin torque

We demonstrate the influence of damping and field-like torques in the magnon–photon coupling process by classically integrating the generalized Landau–Lifshitz–Gilbert equation with RLC equation in which a phase correlation between dynamic magnetization and microwave current through combined Ampère and Faraday effects are considered. We show that the gap between two hybridized modes can be controlled in samples with damping parameter in the order of 10 –3 by changing the direction of the dc current density J if a certain threshold is reached. Furthermore, our results suggest that an experimental realization of the proposed magnon–photon coupling control mechanism is feasible in yttrium iron garnet/Pt hybrid structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of energy storage to reduce electric power system off-nominal frequency deviations

A hybrid power generation system is formed by the combination of an energy storage system (ESS) and a rotating synchronous power generator (SPG). Energy is stored in or released from the ESS in response to measurements of the at least one angle parameter, selected from rotor, torque, or power angle of the SPG, to provide active frequency damping of electrical power output. The control of ESS energy exchange increases the stabilizing impact of the SPG inertia on the frequency of electricity in an electrical network or power grid. The hybrid power generation system can have an effective equal area criterion for stability limit that is greater than that of the SPG operating without the ESS. The hybrid power generation system can enable the electrical network to have a greater proportion of variable or distributed energy resource (DER) power generation systems without otherwise exceeding stability limits.

Vartanian, Charles K.↗

Surface magnetic anisotropy-mediated spin Hall magnetoresistance and spin Seebeck effects in a YIG/Pt heterostructure

The role of magnon-phonon coupling in the low-temperature behavior of the spin Seebeck effect (SSE) in YIG/Pt has been puzzling for more than a decade. Here, to elucidate the origin of the anomalous peak around 80 K, we investigate the temperature evolution of SSE, spin Hall magnetoresistance (SMR), and magnetic anisotropy in the same YIG/Pt heterostructure. We find that these effects, along with magnetic damping, show the peaks at the same temperature (~80 K). This simultaneous occurrence, where no heat is applied in the case of SMR, rules out the phonon-magnon drag related origin of SSE in the YIG/Pt system. We further show that the intrinsic surface anisotropy behavior in YIG is responsible for controlling the SSE, SMR, and magnetic damping in the YIG/Pt structure. Our findings not only help to understand these effects fundamentally but also provide an effective way for improving them by manipulating the surface magnetic anisotropy for spin caloritronic applications.

36 MATERIALS SCIENCE↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms: Preprint

Floating offshore wind turbines have several advantages over their land-based counterparts, including access to stronger, more consistent winds and proximity to population centers. However, increased costs from the platform have been a challenge inhibiting their widespread adoption. New damping technologies with tunable target frequencies and damping ratios promise a greater degree of control over platform motions, allowing hulls to be designed smaller and reducing the overall cost of the turbines. In this work, a control strategy is proposed for these adjustable tuned mass dampers (TMDs). A frequency-domain model of the system is developed, from which response amplitude operators (RAOs) for the platform's rigid-body modes can be obtained for different natural frequencies and damping ratios of the dampers. Using these RAOs, and JONSWAP spectrums of operational and extreme sea states, the performance of the various damper settings are compared by evaluating the standard deviation of a rigid-body motion of interest (platform pitch or heave). By finding the optimal damper setting for a range of representative design load cases (DLCs), a lookup function is made to return the damper target frequency given the peak period of the sea state. To determine the current sea state, we propose a simple estimator that uses wave measurements (e.g., from a measurement buoy) to determine the peak period and significant wave height. The significant wave height is determined using the statistics of the past 100 seconds of wave elevation information and the peak period is computed using a frequency locked loop. Initial results show that we can use these estimated values to control the TMD natural frequency with an open loop controller. The controlled system is tested in a range of environmental conditions determined by the International Electrotechnical Commission design load cases (DLCs), which include normal and extreme wind and wave models. In these tests, we compare the performance of 4 cases: (1) no TMD, (2) a constant TMD based on the worst case DLC, (3) a controlled TMD based on known wind and wave environments, and (4) a real-time controlled TMD using estimated wind and wave environments. The effect of hull-based TMD control is also compared to changes in traditional wind turbine control via blade pitch.

control↗

Packetized Energy Management: Coordinating Transmission and Distribution (Final Report)

The project Packetized Energy Management (PEM): Coordinating Transmission and Distribution was part of the ARPA-E NODES program from 2015 to 2023. The high-level goal of the project was to develop and demonstrate novel, scalable, and impactful technologies related to the coordination of networked distributed energy resources (DERs). By demonstrating responsive means by which fleets of DERs could be coordinated to enhance grid operation and reliability, the U.S. could accelerate renewable integration and electrification efforts and meet decarbonization goals.

25 ENERGY STORAGE↗

Superconducting dome in ferroelectric-type materials from soft mode instability

Here we present a minimal theory of superconductivity enhancement in ferroelectric-type materials. Simple expressions for the optical mode responsible for the soft mode transition are assumed. A key role is played by the anharmonic phonon damping which is modulated by an external control parameter (electron doping or mechanical strain) causing the appearance of the soft mode. It is shown that the enhancement in the superconducting critical temperature T c upon approaching the ferroelectric transition from either side is due to the Stokes electron-phonon scattering processes promoted by strong phonon damping effects.

36 MATERIALS SCIENCE↗

Multilevel Conditional Disturbance Rejection Control for Satellite Attitude Tracking

Recently, the conditional disturbance rejection controller (CDRC) was proposed to improve control performance by leveraging disturbances that have beneficial effects on the system. However, it only considers disturbances acting on the state variable directly influenced by them. Although fast convergence of this state can be achieved with the CDRC, it may unintentionally affect the convergence of the output (i.e., the primary state). Here, in this article, a multilevel CDRC is proposed to enhance satellite attitude control performance by accounting for the effect of disturbances on both attitude (output) and angular velocity. The extended state observer is employed to estimate the lumped disturbance, including the modeling errors and external disturbances. Then, a backstepping-based controller with the multilevel disturbance rejection law (ML-DRL) is designed for attitude tracking. The ML-DRL is developed to improve the control performance by using a disturbance with a damping effect on both attitude and velocity. Faster convergence of attitude and velocity can be achieved by conditionally compensating for the disturbance. The stability of the proposed control method is analyzed by demonstrating that the errors are bounded as time tends to infinity. The attitude control performance of the proposed method is evaluated through numerical examples conducted using the MATLAB/Simulink Multibody tool.

Active disturbance rejection control (ADRC)↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. A wave energy converter (WEC) should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Furthermore, the WEC should be adaptable to different sea states. Herethis work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. It is hypothesized that opening the flaps should result in load shedding at the base of the support structure by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. Increased loads at the structure’s natural period can be mitigated by an axial power take-off damping acting as an additional design parameter to control the loads at the WEC’s support structure.

16 TIDAL AND WAVE POWER↗

Paper #50 Preliminary Sizing of Active Magnetic Bearings for sCO2 Waste-Heat Recovery Application

The team of Southwest Research Institute (SwRI) and GE Vernova (GE) is executing a project developing conceptual designs of high-temperature active magnetic bearings (AMBs) for sCO2 machinery applications. The goals of the project are to develop conceptual designs for radial and thrust AMBs capable of operating in sCO2 environments up to 1000°F. A waste-heat recovery (WHR) application with hermetic machinery is used as a reference case to apply AMBs. This application was previously investigated to compare hermetic machinery enabled by process-lubricated bearings and high-speed motors/generators with traditional machinery configurations using oil-lubricated bearings, gearboxes, and grid-frequency electric machines. In this paper, AMBs are sized for the WHR application machinery. Load capacity estimates are made using first-principle-derived formulas that consider operation at elevated temperatures. Estimates of linearized AMB system coefficients are also made to aid future controller development. Rotor models are developed that account for AMB rotor geometry and housing space requirements. Rotordynamics studies are performed to identify reasonable target values for closed-loop AMB stiffness and closed-loop AMB damping. These target values will be used in future control studies.

Lipham, Robert↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗