Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyclic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Discovery of Cyclic Acylguanidines as Highly Potent and Selective β-Site Amyloid Cleaving Enzyme (BACE) Inhibitors: Part I–Inhibitor Design and Validation

A number of novel amidine containing heterocycles were designed to reproduce the unique interaction pattern, revealed by X-ray crystallography, between the BACE-1 catalytic diad and a weak NMR screening hit, with special attention paid to maintaining the appropriate basicity and limiting the number of H-bonding donors of these scaffolds. The iminohydantoin cores were examined first and found to interact with the catalytic diad in one of two binding modes (A and B), each with the iminohydantoin core flipped 180° in relation to the other. The amidine structural motif within each core forms a bidentate interaction with a different aspartic acid of the catalytic diad. Both modes reproduced a highly conserved interaction pattern between the inhibitors and the catalytic aspartates. Potent iminohydantoin BACE-1 inhibitors have been obtained, validating the molecular design as aspartyl protease catalytic site inhibitors. Brain penetrant small molecule BACE inhibitors with high ligand efficiencies have been discovered, enabling multiple strategies for further development of these inhibitors into highly potent, selective and in vivo efficacious BACE inhibitors.

Zhu, Zhaoning↗

Molecular dynamics simulations of cholesterol-rich membranes using a coarse-grained force field for cyclic alkanes

The architecture of a biological membrane hinges upon the fundamental fact that its properties are determined by more than the sum of its individual components. Studies on model membranes have shown the need to characterize in molecular detail how properties such as thickness, fluidity, and macroscopic bending rigidity are regulated by the interactions between individual molecules in a non-trivial fashion. Simulation-based approaches are invaluable to this purpose but are typically limited to short sampling times and model systems that are often smaller than the required properties. To alleviate both limitations, the use of coarse-grained (CG) models is nowadays an established computational strategy. We here present a new CG force field for cholesterol, which was developed by using measured properties of small molecules, and can be used in combination with our previously developed force field for phospholipids. The new model performs with precision comparable to atomistic force fields in predicting the properties of cholesterol-rich phospholipid bilayers, including area per lipid, bilayer thickness, tail order parameter, increase in bending rigidity, and propensity to form liquid-ordered domains in ternary mixtures. We suggest the use of this model to quantify the impact of cholesterol on macroscopic properties and on microscopic phenomena involving localization and trafficking of lipids and proteins on cellular membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of the chamber wall on fluorocarbon-assisted atomic layer etching of SiO{sub 2} using cyclic Ar/C{sub 4}F{sub 8} plasma

The authors studied the effect of the temperature and chemical state of the chamber wall on process performance for atomic layer etching of SiO{sub 2} using a steady-state Ar plasma, periodic injection of a defined number of C{sub 4}F{sub 8} molecules, and synchronized plasma-based Ar{sup +} ion bombardment. To evaluate these effects, the authors measured the quartz coupling window temperature. The plasma gas phase chemistry was characterized using optical emission spectroscopy. It was found that although the thickness of the polymer film deposited in each cycle is constant, the etching behavior changed, which is likely related to a change in the plasma gas phase chemistry. The authors found that the main gas phase changes occur after C{sub 4}F{sub 8} injection. The C{sub 4}F{sub 8} and the quartz window react and generate SiF and CO. The emission intensity changes with wall surface state and temperature. Therefore, changes in the plasma gas species generation can lead to a shift in etching performance during processing. During initial cycles, minimal etching is observed, while etching gradually increases with cycle number.

42 ENGINEERING↗

Cyclic strain increases protease-activated receptor-1 expression in vascular smooth muscle cells

Cyclic strain regulates many vascular smooth muscle cell (VSMC) functions through changing gene expression. This study investigated the effects of cyclic strain on protease-activated receptor-1 (PAR-1) expression in VSMCs and the possible signaling pathways involved, on the basis of the hypothesis that cyclic strain would enhance PAR-1 expression, reflecting increased thrombin activity. Uniaxial cyclic strain (1 Hz, 20%) of cells cultured on elastic membranes induced a 2-fold increase in both PAR-1 mRNA and protein levels. Functional activity of PAR-1, as assessed by cell proliferation in response to thrombin, was also increased by cyclic strain. In addition, treatment of cells with antioxidants or an NADPH oxidase inhibitor blocked strain-induced PAR-1 expression. Preincubation of cells with protein kinase inhibitors (staurosporine or Ro 31-8220) enhanced strain-increased PAR-1 expression, whereas inhibitors of NO synthase, tyrosine kinase, and mitogen-activated protein kinases had no effect. Cyclic strain in the presence of basic fibroblast growth factor induced PAR-1 mRNA levels beyond the effect of cyclic strain alone, whereas no additive effect was observed between cyclic strain and platelet-derived growth factor-AB. Our findings that cyclic strain upregulates PAR-1 mRNA expression but that shear stress downregulates this gene in VSMCs provide an opportunity to elucidate signaling differences by which VSMCs respond to different mechanical forces.

NASA Discipline Cell Biology↗

Nrf2 activation is involved in osteogenic differentiation of periodontal ligament stem cells under cyclic mechanical stretch

Highlights: • Cyclic mechanical stretch increases the nuclear accumulation of Nrf2 in PDLSCs. • T-BHQ promotes osteogenic differentiation under cyclic mechanical stretch. • Nrf2 activation may improve alveolar bone remodeling during orthodontic treatment. During orthodontic treatment, mechanical stretch serves a crucial function in osteogenic differentiation of periodontal ligament stem cells (PDLSCs). Up-regulated reactive oxygen species (ROS) level is a result of cyclic mechanical stretch in many cell types. Nuclear factor erythroid-2-related factor-2 (Nrf2) is a master regulator in various antioxidants expression. However, it is not known whether cyclic mechanical stretch could induce the ROS generation in PDLSCs and whether Nrf2 participated in this process. The present study was aimed to investigate the role of Nrf2 in PDLSCs under cyclic mechanical stretch. Our results showed that cyclic mechanical stretch increased ROS level and the nuclear accumulation of Nrf2 during osteoblast differentiation. Knocking down Nrf2 by siRNA transfection increased ROS formation and suppressed osteogenic differentiation in PDLSCs. T-BHQ, a Nrf2 activator, promoted the osteogenic differentiation in PDLSCs under cyclic mechanical stretch, and improved the microstructure of alveolar bone during orthodontic tooth movement in rats by employing micro-CT system. Taken together, Nrf2 activation was involved in osteogenic differentiation under cyclic mechanical stretch in PDLSCs. T-BHQ could promote the osteogenic differentiation in vitro and in vivo, suggesting a promising option for the remodeling of the alveolar bone during orthodontic tooth movement.

60 APPLIED LIFE SCIENCES↗

Co-Crystal Structures of PKG Iβ (92–227) with cGMP and cAMP Reveal the Molecular Details of Cyclic-Nucleotide Binding

Background: Cyclic GMP-dependent protein kinases (PKGs) are central mediators of the NO-cGMP signaling pathway and phosphorylate downstream substrates that are crucial for regulating smooth muscle tone, platelet activation, nociception and memory formation. As one of the main receptors for cGMP, PKGs mediate most of the effects of cGMP elevating drugs, such as nitric oxide-releasing agents and phosphodiesterase inhibitors which are used for the treatment of angina pectoris and erectile dysfunction, respectively. Methodology/Principal Findings: We have investigated the mechanism of cyclic nucleotide binding to PKG by determining crystal structures of the amino-terminal cyclic nucleotide-binding domain (CNBD-A) of human PKG I bound to either cGMP or cAMP. We also determined the structure of CNBD-A in the absence of bound nucleotide. The crystal structures of CNBD-A with bound cAMP or cGMP reveal that cAMP binds in either syn or anti configurations whereas cGMP binds only in a syn configuration, with a conserved threonine residue anchoring both cyclic phosphate and guanine moieties. The structure of CNBD-A in the absence of bound cyclic nucleotide was similar to that of the cyclic nucleotide bound structures. Surprisingly, isothermal titration calorimetry experiments demonstrated that CNBD-A binds both cGMP and cAMP with a relatively high affinity, showing an approximately two-fold preference for cGMP. Conclusions/Significance: Our findings suggest that CNBD-A binds cGMP in the syn conformation through its interaction with Thr193 and an unusual cis-peptide forming residues Leu172 and Cys173. Although these studies provide the first structural insights into cyclic nucleotide binding to PKG, our ITC results show only a two-fold preference for cGMP, indicating that other domains are required for the previously reported cyclic nucleotide selectivity.

59 BASIC BIOLOGICAL SCIENCES↗

Cyclic Axial-Torsional Deformation Behavior of a Cobalt-Base Superalloy

The cyclic, high-temperature deformation behavior of a wrought cobalt-base super-alloy, Haynes 188, is investigated under combined axial and torsional loads. This is accomplished through the examination of hysteresis loops generated from a biaxial fatigue test program. A high-temperature axial, torsional, and combined axial-torsional fatigue database has been generated on Haynes 188 at 760 C. Cyclic loading tests have been conducted on uniform gage section tubular specimens in a servohydraulic axial-torsional test rig. Test control and data acquisition were accomplished with a minicomputer. The fatigue behavior of Haynes 188 at 760 C under axial, torsional, and combined axial-torsional loads and the monotonic and cyclic deformation behaviors under axial and torsional loads have been previously reported. In this paper, the cyclic hardening characteristics and typical hysteresis loops in the axial stress versus axial strain, shear stress ,versus engineering shear strain, axial strain versus engineering shear strain. and axial stress versus shear stress spaces are presented for cyclic in-phase and out-of-phase axial-torsional tests. For in-phase tests, three different values of the proportionality constant lambda (the ratio of engineering shear strain amplitude to axial strain amplitude, are examined, viz. 0.86, 1.73, and 3.46. In the out-of-phase tests, three different values of the phase angle, phi (between the axial and engineering shear strain waveforms), are studied, viz., 30, 60, and 90 degrees with lambda equals 1.73. The cyclic hardening behaviors of all the tests conducted on Haynes 188 at 760 C are evaluated using the von Mises equivalent stress-strain and the maximum shear stress-maximum engineering shear strain (Tresca) curves. Comparisons are also made between the hardening behaviors of cyclic axial, torsional, and combined in-phase (lambda = 1.73 and phi = 0) and out-of-phase (lambda = 1.73 and phi = 90') axial-torsional fatigue tests. These comparisons are accomplished through simple Ramberg-Osgood type stress-strain functions for cyclic, axial stress-strain and shear stress-engineering shear strain curves.

Bonacuse, Peter J.↗

Cyclic Elastoplastic Performance of Aluminum 7075-T6 Under Strain- and Stress-Controlled Loading

Elastoplastic investigations of aerospace aluminum are important in the development of an understanding of the possible cyclic transient effects and their contribution to the material performance under cyclic loading. Cyclic plasticity can occur in an aerospace aluminum component or structure depending on the loading conditions and the presence of external and internal discontinuities. Therefore, it is vital that the cyclic transient effects of aerospace aluminum are recognized and understood. This study investigates experimentally the cyclic elastoplastic performance of aluminum 7075-T6 loaded in symmetric strain control, and asymmetric stress and strain control. A combination of cyclic hardening and softening was noticed from high strain amplitude symmetric strain-controlled tests and at low stress amplitude asymmetric stress-controlled tests. From asymmetric strain control results, the extent of mean stress relaxation depended on the size of the strain amplitude. Additionally, saturation of the ratcheting strain (plastic shakedown) was also found to occur during asymmetric stress control tests. The experimental results were further analyzed using published microstructure research from the past two decades to provide added explanation of the micro-mechanism contribution to the cyclic transient behavior.

36 MATERIALS SCIENCE↗

Gold(I) Cationization Promotes Ring Opening in Lysine-Containing Cyclic Peptides

A strategy to sequence lysine-containing cyclic peptides by MS{sup n} is presented. Doubly protonated cyclic peptides ions are transformed into gold (I) cationized peptide ions via cation switching ion/ion reaction. Gold(I) cationization facilitates the oxidation of neutral lysine residues in the gas phase, weakening the adjacent amide bond. Upon activation, facile cleavage N-terminal to the oxidized lysine residue provides a site-specific ring opening pathway that converts cyclic peptides into acyclic analogs. The ensuing ion contains a cyclic imine as the new N-terminus and an oxazolone, or structural equivalent, as the new C-terminus. Product ions are formed from subsequent fragmentation events of the linearized peptide ion. Such an approach simplifies MS/MS data interpretation as a series of fragment ions with common N- and C-termini are generated. Results are presented for two cyclic peptides, sunflower trypsin inhibitor and the model cyclic peptide, β-Loop. The power of this strategy lies in the ability to generate the oxidized peptide, which is easily identified via the loss of HAuNH{sub 3} from [M + Au]{sup +}. While some competitive processes are observed, the site of ring opening can be pinpointed to the lysine residue upon MS{sup 4} enabling the unambiguous sequencing of cyclic peptides. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}

In this paper, we study linear and cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}. The ring F{sub 2}+uF{sub 2}+vF{sub 2} is the smallest non-Frobenius ring. We characterize the structure of cyclic codes over the ring R=F{sub 2}+uF{sub 2}+vF{sub 2} using of the work Abualrub and Saip (Des Codes Cryptogr 42:273–287, 2007). We study the rank and dual of cyclic codes of odd length over this ring. Specially, we show that the equation |C||C{sup ⊥}|=|R|{sup n} does not hold in general for a cyclic code C of length n over this ring. We also obtain some optimal binary codes as the images of cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2} under a Gray map, which maps Lee weights to Hamming weights. Finally, we give a condition for cyclic codes over R that contains its dual and find quantum codes over F{sub 2} from cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}.

97 MATHEMATICS AND COMPUTING↗

Cyclic stretch increases mitochondrial biogenesis in a cardiac cell line

Unlike stable and immobile cell line conditions, animal hearts contract and relax to pump blood throughout the body. Mitochondria play an essential role by producing biological energy molecules to maintain heart function. In this study, we assessed the effect of heart mimetic cyclic stretch on mitochondria in a cardiac cell line. To mimic the geometric and biomechanical conditions surrounding cells in vivo, cyclic stretching was performed on HL-1 murine cardiomyocytes seeded onto an elastic micropatterned substrate (10% elongation, 0.5 Hz, 4 h/day). Cell viability, semi-quantitative Q-PCR, and western blot analyses were performed in non-stimulated control and cyclic stretch stimulated HL-1 cell lines. Cyclic stretch significantly increased the expression of mitochondria biogenesis-related genes (TUFM, TFAM, ERRα, and PGC1-α) and mitochondria oxidative phosphorylation-related genes (PHB1 and CYTB). Western blot analysis confirmed that cyclic stretch increased protein levels of mitochondria biogenesis-related proteins (TFAM, and ERRα) and oxidative phosphorylation-related proteins (NDUFS1, UQCRC, and PHB1). Consequently, cyclic stretch increased mitochondrial mass and ATP production in treated cells. Our results suggest that cyclic stretch transcriptionally enhanced mitochondria biogenesis and oxidative phosphorylation without detrimental effects in a cultured cardiac cell line.

60 APPLIED LIFE SCIENCES↗

Chemiluminescent Biosensors for Detection of Second Messenger Cyclic di-GMP

Bacteria colonize highly diverse and complex environments, from gastrointestinal tracts to soil and plant surfaces. This colonization process is controlled in part by the intracellular signal cyclic di-GMP, which regulates bacterial motility and biofilm formation. To interrogate cyclic di-GMP signaling networks, a variety of fluorescent biosensors for live cell imaging of cyclic di-GMP have been developed. However, the need for external illumination precludes the use of these tools for imaging bacteria in their natural environments, including in deep tissues of whole organisms and in samples that are highly autofluorescent or photosensitive. The need for genetic encoding also complicates the analysis of clinical isolates and environmental samples. Toward expanding the study of bacterial signaling to these systems, we have developed the first chemiluminescent biosensors for cyclic di-GMP. The biosensor design combines the complementation of split luciferase (CSL) and bioluminescence resonance energy transfer (BRET) approaches. Furthermore, we developed a lysate-based assay for biosensor activity that enabled reliable high-throughput screening of a phylogenetic library of 92 biosensor variants. The screen identified biosensors with very large signal changes (~40- and 90-fold) as well as biosensors with high affinities for cyclic di-GMP ($K_D$ < 50 nM). These chemiluminescent biosensors then were applied to measure cyclic di-GMP levels in $E. coli$. The cellular experiments revealed an unexpected challenge for chemiluminescent imaging in Gram negative bacteria but showed promising application in lysates. Taken together, this work establishes the first chemiluminescent biosensors for studying cyclic di-GMP signaling and provides a foundation for using these biosensors in more complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cyclic creep-rupture behavior of three high-temperature alloys.

Study of some important characteristics of the cyclic creep-rupture curves for the titanium alloy 6Al-2Sn-4Zr-2Mo at 900 and 1100 F (755 and 865 K), the cobalt-base alloy L-605 at 1180 F (910 K), and for two hardness levels of 316 stainless steel at 1300 F (980 K). The cyclic creep-rupture curve relates tensile stress and tensile time-to-rupture for strain-limited cyclic loading and has been found to be independent of the total strain range and the level of compressive stress employed in the cyclic creep-rupture tests. The cyclic creep-rupture curve was always found to be above and to the right of the conventional (constant load) monotonic creep-rupture curve by factors ranging from 2 to 10 in time-to-rupture. This factor tends to be greatest when the creep ductility is large. Cyclic creep acceleration was observed in every cyclic creep-rupture test conducted. The phenomenon was most pronounced at the highest stress levels and when the tensile and compressive stresses were completely reversed. In general, creep rates were found to be lower in compression than in tension for equal true stresses. The differences, however, were strongly material-dependent.

Halford, G. R.↗