Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ionic Control over Ferroelectricity in 2D Layered van der Waals Capacitors

The van der Waals layered material CuInP 2 S 6 features interesting functional behavior, including the existence of four uniaxial polarization states, polarization reversal against the electric field through Cu ion migration, a negative-capacitance regime, and reversible extraction of Cu ions. At the heart of these characteristics lies the high mobility of Cu ions, which also determines the spontaneous polarization. Therefore, Cu migration across the lattice results in unusual ferroelectric behavior. Here, we demonstrate how the interplay of polar and ionic properties provides a path to ionically controlled ferroelectric behavior, achieved by applying selected DC voltage pulses and subsequently probing ferroelectric switching during fast triangular voltage sweeps. Using current measurements and theoretical calculations, we observe that increasing DC pulse duration results in higher ionic currents, the buildup of an internal electric field that shifts polarization loops, and an increase in total switchable polarization by ~50% due to the existence of a high polarization phase which is stabilized by the internal electric field. Apart from tuning ferroelectric behavior by selected square pulses, hysteretic polarization switching can even be entirely deactivated and reactivated, resulting in three-state systems where polarization switching is either inhibited or can be performed in two different directions.

36 MATERIALS SCIENCE↗

Interplay between magnetism and superconductivity in UTe 2

Time-reversal symmetry breaking (TRSB) in UTe 2 was inferred from observations of a spontaneous Kerr response in the superconducting state after cooling in zero magnetic field, while a finite c-axis magnetic field training was further used to determine the nature of the nonunitary composite order parameter of this material. Here, we present an extensive study of the magnetic-field-trained Kerr effect, which unveils a unique critical state of pinned “ferromagnetic vortices.” We show that a remanent Kerr signal appears following the removal of a training magnetic field, which reflects the response to the TRSB order parameter and the external magnetic field through the paramagnetic susceptibility. Furthermore, this unambiguously demonstrates the importance of the magnetic fluctuations and their intimate relation to the composite order parameter. Focusing the beam on the center of the sample, we are able to accurately determine the maximum field that is screened by the critical state and the respective critical current. Measurements in the presence of magnetic field show the tendency of the superconductor to produce shielding currents that oppose the increase in vortex-induced magnetization due to the diverging paramagnetic susceptibility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial and Kinematic Clustering of Stars in the Galactic Disk

The Galactic disk is expected to be spatially and kinematically clustered on many scales due to both star formation and the Galactic potential. In this work we calculate the spatial and kinematic two-point correlation functions (TPCF) using a sample of 1.7 × 10 6 stars with radial velocities from Gaia DR2. Clustering is detected on spatial scales of 1–300 pc and a velocity scale of 15 km s –1 . After removing bound structures, the data have a power-law index of γ ≈ –1 for 1 pc < Δr < 100 pc and γ ≲ –1.5 for Δr > 100 pc. We interpret these results with the aid of a star-by-star simulation of the Galaxy, in which stars are born in clusters orbiting in a realistic potential that includes spiral arms, a bar, and giant molecular clouds. We find that the simulation largely agrees with the observations at most spatial and kinematic scales. In detail, the TPCF in the simulation is shallower than the data at ≲20 pc scales, and steeper than the data at ≳30 pc. We also find a persistent clustering signal in the kinematic TPCF for the data at large Δv (>5 km s –1 ) that is not present in the simulations. We speculate that this mismatch between observations and simulations may be due to two processes: hierarchical star formation and transient spiral arms. Furthermore, we also predict that the addition of ages and metallicities measured with a precision of 50% and 0.05 dex, respectively, will enhance the clustering signal beyond current measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

A trapping tolerant drain current based temperature measurement of β -Ga 2 O 3 MOSFETs

The drain current temperature dependence is an efficient way to determine the channel temperature in semiconductor devices; however, it has been challenging to use due to the potential interference of trapping effects. A trapping tolerant method is proposed, illustrated here for Ga 2 O 3 MOSFETs, making in situ temperature measurements possible, allowing a thermal resistance of 59 K∙mm/W to be measured in Ga 2 O 3 MOSFETs. However, neglecting the effect of trapping causes an error of ~15% in the channel temperature measured using the drain current. 3D simulations show that the measured channel temperature is the average temperature value between source and drain contact.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inference of the Mass Composition of Cosmic Rays with Energies from 10 18.5 to 10 20 eV Using the Pierre Auger Observatory and Deep Learning

We present measurements of the atmospheric depth of the shower maximum X max , inferred for the first time on an event-by-event level using the surface detector of the Pierre Auger Observatory. Using deep learning, we were able to extend measurements of the X max distributions up to energies of 100 EeV ( 10 20 eV ), not yet revealed by current measurements, providing new insights into the mass composition of cosmic rays at extreme energies. Gaining a 10-fold increase in statistics compared to the fluorescence detector data, we find evidence that the rate of change of the average X max with the logarithm of energy features three breaks at 6.5 ± 0.6 ( stat ) ± 1 ( syst ) EeV , 11 ± 2 ( stat ) ± 1 ( syst ) EeV , and 31 ± 5 ( stat ) ± 3 ( syst ) EeV , in the vicinity to the three prominent features (ankle, instep, suppression) of the cosmic-ray flux. The energy evolution of the mean and standard deviation of the measured X max distributions indicates that the mass composition becomes increasingly heavier and purer, thus being incompatible with a large fraction of light nuclei between 50 and 100 EeV. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The two-photon exchange experiment at DESY

We propose a new measurement of the ratio of positron-proton to electron-proton elastic scattering at DESY. The purpose is to determine the contributions beyond single-photon exchange, which are essential for the Quantum Electrodynamic (QED) description of the most fundamental process in hadronic physics. By utilizing a 20 cm long liquid hydrogen target in conjunction with the extracted beam from the DESY synchrotron, we can achieve an average luminosity of 2.12 x 10 35 cm –2 •s –1 (≈ 200 times the luminosity achieved by OLYMPUS). The proposed two-photon exchange experiment (TPEX) entails a commissioning run at a beam energy of 2 GeV, followed by measurements at 3 GeV, thereby providing new data up to Q 2 = 4.6 (GeV/c) 2 (twice the range of current measurements). We present and discuss the proposed experimental setup, run plan, and expectations.

Physics↗

Towards a 𝜈 𝜇 CC 1𝜇 + 1p exc. cross section measurement at the NOvA Near Detector

In the recent past, the NOvA near detector has been used to perform several neutrino-matter cross section measurements as a function of final state muon or electron kinematics around $E_\nu = 2$ GeV. In this talk, I show how the muon neutrino charged-current measurement in particular can be extended into a more exclusive region of phase space in order to probe nuclear effects. This can be done by selecting a final state with 1$\mu$, 1 proton, and nothing else, and measuring the cross section in terms of transverse kinematic imbalance (TKI) variables. The measurement I describe here would also be sensitive to quasi-elastic (QEL), two-particle two-hole (2p2h), and resonant (RES) neutrino interactions. Currently, I am optimizing the selection cuts for this analysis and developing a proton momentum estimator, which is necessary for reconstructing the TKI variables.

Weber, Colin [Minnesota U.]↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Large-volume CdZnTe bar detectors characterized by laser-induced transient currents

In this work, we studied the free-carrier transport properties and space-charge formation/polarization in a CdZnTe bar-shaped radiation detector using the Laser-Induced Transient Current technique. We found out that a steady-state space charge ranging from 8 x 10 8 to 2.1 x 10 9 cm -3 is formed throughout the detector at about 0.5 s following biasing. The measured current waveforms were modeled by Monte Carlo simulations after taking into account the electric and weighting fields inside the detector and shielding box. Modeling of the unpolarized waveforms revealed an exceptionally high electron mobility-lifetime product μ e τ e ≥0.095cm 2 V -1 . The observed formation of positive space charge in the biased detector and linear scaling of the current waveform shapes on applied bias revealed that the detector polarization is attributed to carrier injection at the anode. In conclusion, measurements in pulsed and DC bias in modified electrode geometry proved the surface-charge formation.

47 OTHER INSTRUMENTATION↗

Measurements of the electron energy distribution function in partially magnetized low temperature plasmas

While Langmuir probes (LPs) are relatively simple and inexpensive plasma diagnostics for the electron density, temperature, and the electron energy distribution function (EEDF), the interpretation of the measured current–voltage (I–V) characteristic is complicated considerably by the presence of a magnetic field. In regimes where the electron gyroradius is comparable to the probe radius, the electron flux to the probe surface is retarded by reduced mobility across field lines and can no longer be described by a thermal model. Predicting the current collected by the probe in these regimes requires accurate estimates of the plasma diffusion coefficients, which are usually difficult to obtain. In this work, we measure electron energy distribution functions in E×B plasmas with magnetized electrons and non-magnetized ions in argon and krypton gases, using both a LP and laser Thomson scattering (LTS) at various magnetic fields. Using the LTS measurements to provide a robust benchmark for comparison, we compare existing theories describing the flux to the probe under magnetized conditions. We find that even when the electron gyroradius associated with the effective electron temperature is small compared to the probe radius, the EEDF computed using classical probe theory is still robust at energies higher than the energy at which the gyroradius becomes larger than the probe size. For plasmas that are not strongly non-Maxwellian, we formulate a method to extract robust density and temperature measurements using physics-informed fitting techniques to analyze EEDFs computed using classical theory.

Devin, E. G. [Princeton Plasma Physics Laboratory ↗

Photometric Objects Around Cosmic Webs (PAC) Delineated in a Spectroscopic Survey. III. Accurate Measurement of Galaxy Stellar Mass Function with the Aid of Cosmological Redshift Surveys

We present a novel method to accurately measure the galaxy stellar mass function (GSMF) based upon the Photometric objects Around Cosmic webs (PAC) method developed in our first paper (Paper I) of the series. The method allows us to measure the GSMF to a lower-mass end that is not accessible to the spectroscopic sample used in the PAC. Compared with Paper I, the current measurement of GSMF is direct and model independent. We measure the GSMFs in the redshift ranges of z$^{3}_{s}$ < 0.2, 0.2 < z s < 0.4, and 0.5 < z s < 0.7 down to stellar masses of M* = 10 8.2 , 10 10.6 , and 10 10.6 M ⊙ , using the data from the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys and the spectroscopic samples of Slogan Digital Sky Survey (i.e., Main, LOWZ, and CMASS samples). Our results show that there is no evolution of GSMF from z s = 0.6 to z s = 0.1 for M* > 10 10.6 M ⊙ , and that there is a clear upturn at M* ≈ 10 9.5 M ⊙ toward smaller galaxies in the local GMSF at z s = 0.1. We provide an accurate double Schechter fit to the local GSMF for the entire range of M* and a table of our measurements at the three redshifts, which can be used to test theories of galaxy formation. Our method can achieve an accurate measurement of GSMF to the stellar mass limit where the spectroscopic sample is already highly incomplete (e.g., ~ 10 -3 ) for its target selection.

79 ASTRONOMY AND ASTROPHYSICS↗

Physical Properties of Candidate X-ray Detector Material Rb 4 Ag 2 BiBr 9

Recently, metal halide perovskites have emerged as promising semiconductor candidates for sensitive X-ray photon detection due to their suitable band gap energies, excellent charge transport properties, and low material cost afforded by their low-temperature solution-processing preparation. Furthermore, we report an improved methodology for single crystal growth and thermal and electrical properties of a two-dimensional (2D) layered halide material Rb 4 Ag 2 BiBr 9 , which has been identified as a potential candidate for X-ray radiation detection applications. The measured heat capacity for Rb 4 Ag 2 BiBr 9 implies that there are no structural phase transitions upon cooling. Temperature dependence of thermal transport measurements further suggests remarkably low thermal conductivities of Rb 4 Ag 2 BiBr 9 that are comparable to the lowest reported in literature. The bulk crystal resistivity is determined to be 2.59 × 10 9 Ω·cm from the current–voltage (I–V) curve. Density of trap states is estimated to be ~10 10 cm –3 using the space-charge-limited-current measurements. The fabricated Rb 4 Ag 2 BiBr 9 -based X-ray detector shows good operational stability with no apparent current drift, which may be ascribed to the 2D crystal structure of Rb 4 Ag 2 BiBr 9 . Finally, by varying the X-ray tube current to change the corresponding dose rate, the Rb4Ag2BiBr9 X-ray detector sensitivity is determined to be 222.03 μC Gy –1 cm –2 (at an electric field of E = 24 V/mm).

36 MATERIALS SCIENCE↗

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

Measurement of CP asymmetries in ${D}_{(s)}^{+}\to \eta {\pi}^{+}$ and ${D}_{(s)}^{+}\to {\eta}^{\prime }{\pi}^{+}$ decays

Searches for CP violation in the decays ${D}_{(s)}^{+}\to \eta {\pi}^{+}$ and ${D}_{(s)}^{+}\to {\eta}^{\prime }{\pi}^{+}$ are performed using pp collision data corresponding to 6 fb –1 of integrated luminosity collected by the LHCb experiment. The calibration channels ${D}_{(s)}^{+}\to \phi {\pi}^{+}$ are used to remove production and detection asymmetries. The resulting CP-violating asymmetries are $\mathcal{A}^{CP} = (D^+ \to ηπ^+) = (0.34 ± 0.66 ± 0.16 ± 0.05)$ %, $\mathcal{A}^{CP} = (D^+_s \to ηπ^+) = (0.32 ± 0.51 ± 0.12)$ %, $\mathcal{A}^{CP} = (D^+ \to η'π^+) = (0.49 ± 0.18 ± 0.06 ± 0.05)$ %, $\mathcal{A}^{CP} = (D^+_s \to η'π^+) = (0.01 ± 0.12 ± 0.08)$ %, where the first uncertainty is statistical, the second is systematic and the third, relevant for the D + channels, is due to the uncertainty on ${\mathcal{A}}^{CP}=\left({D}^{+}\to \phi {\pi}^{+}\right)$. These measurements, currently the most precise for three of the four channels considered, are consistent with the absence of CP violation. A combination of these results with previous LHCb measurements is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Initial Verification Testing of an In Situ Load Retention Aging Fixture

Load retention is a key metric used to evaluate long-term mechanical functionality of polymeric materials. Its measurement currently requires periodically removing the aging fixtures from the ovens, removing the specimens from the fixtures, and performing load testing on the specimens. The ability to perform load measurement in situ (i.e., without having to remove the specimens from the fixtures, and possibly even the ovens) would facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of specimens which is more representative of the actual application.

36 MATERIALS SCIENCE↗