Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost of excess load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Carbon-Based Wear Coatings: Properties and Applications

The technical function of numerous engineering systems - such as vehicles, machines, and instruments - depends on the processes of motion and on the surface systems. Many processes in nature and technology depend on the motion and dynamic behavior of solids, liquids, and gases. Smart surface systems are essential because of the recent technological push toward higher speeds, loads, and operating temperatures; longer life; lighter weight and smaller size (including nanotechnology); and harsh environments in mechanical, mechatronic, and biomechanical systems. If proper attention is not given to surface systems, then vehicles, machines, instruments, and other technical systems could have short lives, consume excessive energy, experience breakdowns, result in liabilities, and fail to accomplish their missions. Surface systems strongly affect our national economy and our lifestyles. At the NASA Glenn Research Center, we believe that proper attention to surface systems, especially in education, research, and application, could lead to economic savings of between 1.3 and 1.6 percent of the gross domestic product. Wear coatings and surface systems continue to experience rapid growth as new coating and surface engineering technologies are discovered, more cost-effective coating and surface engineering solutions are developed, and marketers aggressively pursue, uncover, and exploit new applications for engineered surface systems in cutting tools and wear components. Wear coatings and smart surface systems have been used widely in industrial, consumer, automotive, aerospace, and biomedical applications. This presentation expresses the author's views of and insights into smart surface systems in wear coatings. A revolution is taking place in carbon science and technology. Diamond, an allotrope of carbon, joins graphite, fullerenes, and nanotubes as its major pure carbon structures. It has a unique combination of extreme properties: hardness and abrasion resistance; adhesion and friction; thermal conductivity; chemical and thermal inertness; corrosion and wear resistance; radiation resistance and biocompatibility; electronic, acoustic, and electrochemical characteristics; and environmental compatibility. These properties make diamond attractive for a wide range of diverse applications. In particular, chemical-vapor-deposited (CVD) diamond coatings offer a broad potential, since size and cost are not as limiting. The production of large, superhard diamond films or sheets at low cost make designer materials possible. This presentation is divided into two sections: properties and applications of hard coatings. The first section is concerned with the fundamental properties of the surfaces of CVD diamonds and related materials. The surface properties of hard coatings with favorable coefficients of friction (less than or equal to 0.1) and dimensional wear coefficients (less than or equal to 10(exp -6) cubic millimeters/N.m) in specific environments are discussed. The second section is devoted to applications. Examples of actual, successful applications and of potential challenging applications of the coatings.such as CVD diamond, diamondlike carbon, and cubic boron nitride-are described. Cutting tools coated with CVD diamond are of immediate commercial interest. Other applications, such as microelectromechanical systems (MEMS), valves, and bearings of CVD diamond, are being developed, but at a slow pace. There is a continually growing interest in commercializing diamondlike carbon for wear parts applications, such as biomedical parts and implants, forming dies, transport guides, magnetic tapes and disks, valves, and gears. Cubic boron nitride films are receiving attention because they can be used on tools to machine ferrous materials or on wear parts in sliding contact with ferrous materials.

Miyoshi, Kazuhisa↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Definition study for photovoltaic residential prototype system

A site evaluation was performed to assess the relative merits of different regions of the country in terms of the suitability for experimental photovoltaic powered residences. Eight sites were selected based on evaluation criteria which included population, photovoltaic systems performance and the cost of electrical energy. A parametric sensitivity analysis was performed for four selected site locations. Analytical models were developed for four different power system implementation approaches. Using the model which represents a direct (or float) charge system implementation the performance sensitivity to the following parameter variations is reported: (1) solar roof slope angle; (2) ratio of the number of series cells in the solar array to the number of series cells in the lead-acid battery; and (3) battery size. For a Cleveland site location, a system with no on site energy storage and with a maximum power tracking inverter which feeds back excess power to the utility was shown to have 19 percent greater net system output than the second place system. The experiment test plan is described. The load control and data acquisition system and the data display panel for the residence are discussed.

Shepard, N. F.↗

Parametric-Based Heat Rejection Trade Study for Lunar and Martian Surface Operations

Establishing and maintaining a sustained presence on the lunar and/or Martian surfaces will require a diverse portfolio of surface elements (e.g., habitation, mobility, power generation, etc.). Many of these systems generate excess heat that must be rejected across a wide range of magnitudes, temperatures, and duty cycles and under variable environmental conditions. To identify the most promising heat rejection approaches for this diverse portfolio, a heat rejection trade study was conducted to evaluate the performance of different technology approaches across a spectrum of surface environments and heat-load requirements. The trade study consisted of three stages: (1) development of a parametric-based modeling framework, (2) creation of a database of heat rejection technologies, surface elements, and environmental conditions for the Moon and Mars, and (3) execution of a quantitative analysis of various heat rejection technologies across different operating conditions and surface elements. The modeling framework is developed in Python and Excel to prioritize small model size and hence low computational cost to enable large parametric sweeps while avoiding the reliance on proprietary software. Individual heat rejection processes are represented as simple Excel models, and a centralized Python script interfaces with the models to coordinate the parametric study. These simple sizing models were developed to take heat load requirements and environmental parameters as inputs and compute mass, power, and volume as outputs. Rather than assess each heat rejection technology separately for each surface element, a unified parametric space was developed to evaluate all technologies across all elements. This parametric space includes factors related to heat load (e.g., magnitude or temperature) and environment (e.g., surface temperature, sky temperature, solar flux). This effort generated a database containing information on over 60 heat rejection technologies and 30 surface elements. For each surface element, the expected heat rejection requirements were documented and analyzed to determine the most common needs shared across all elements. Environmental conditions at various lunar and Martian latitudes were also established for worst-case hot and worst-case cold scenarios. High-fidelity heat rejection models are currently under development. Preliminary trades between heat rejection technologies including radiators, venting technologies, convective coolers, and more have been conducted to identify promising options. This presentation will summarize the preliminary trade results and provide an overview and discussion of the expected heat loads and thermal environments for sustained surface operations on the Moon and Mars.

Heat Rejection↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

A scoping study of far-SOL main-wall protection limiters for steady-state operation of compact pilot plant tokamaks

We present a novel method for handling steady-state heat fluxes incident on the main wall of pilot plant-scale magnetic fusion devices, based on the utilization of protection limiters in the far scrape-off layer (SOL). This method helps avoid large plasma-wall gaps, without excessively compromising blanket performance. We present an optimization algorithm for determining the appropriate size and scale of these protection limiters given (1) probability distributions of SOL plasma parameters and (2) assumed risk tolerance. As part of this optimization, we have developed an analytic description of parallel heat fluxes across limiter shadows, and an objective cost function (the ‘Far-SOL Marginal Cost’) to quantify the impact that different main-wall thermal management design choices have on reactor capital cost. Applying the model to a midscale fusion pilot plant concept shows that making use of far-SOL protection limiters can reduce capital costs on the order of $500 M, relative to naively increasing the plasma-wall gap. Our analysis demonstrates that the far-SOL power decay length is the highest-leverage plasma assumption for thermal loading of the first wall, and the primary cost driver for main wall thermal management. The relative cost efficiency of protection limiters increases as assumptions on the far-SOL heat flux become more pessimistic. The concepts described in this paper motivate the further development of far-SOL protection limiters as part of larger efforts to design economical core-edge-wall compatible solutions for a fusion pilot plant.

Design under uncertainty↗

Fabrication of low-cost Mod-OA wood composite wind turbine blades

The wood composite blades were fabricated by using epoxy resin-bonded laminates of Douglas fir veneers for the leading edge spar sections and honeycomb-cored birch plywood panels for the blade trailing edge or afterbody sections. The blade was joined to the wind turbine hub assembly by epoxy resin-bonded steel load take-off studs. The wood composite blades were installed in the Mod-OA wind turbine test facility at Kahuku, Hawaii. The wood composite blades have successfully completed high power (average of 150 kW) operations for an eighteen month period (nearly 8,000 hr) before replacement with another set of wood composite blades. The original set of blades was taken out of service because of the failure of the shank on one stud. An inspection of the blades at NASA-Lewis showed that the shank failure was caused by a high stress concentration at a corrosion pit on the shank fillet radius which resulted in fatigue stresses in excess of the endurance limit.

Lark, R. F.↗

Identification of Rotorcraft Structural Dynamics from Flight and Wind Tunnel Data

Excessive vibration remains one one of the most difficult problems that faces the helicopter industry today, affecting all production helicopters at some phase of their development. Vibrations in rotating structures may arise from external periodic dynamic airloads whose frequencies are are close to the natural frequencies of the rotating system itself. The goal for the structures engineer would thus be to design a structure as free from resonance effects as possible. In the case of a helicopter rotor blade these dynamic loads are a consequence of asymmetric airload distribution on the rotor blade in forward flight, leading to a rich collection of higher harmonic airloads that force rotor and airframe response. Accurate prediction of the dynamic characteristics of a helicopter rotor blade will provide the opportunity to affect in a positive manner noise intensity, vibration level, durability, reliability and operating costs by reducing objectionable frequencies or moving them to a different frequency range and thus providing us with a lower vibration rotor. In fact, the dynamic characteristics tend to define the operating limits of a rotorcraft. As computing power has increased greatly over the last decade, researchers and engineers have turned to analyzing the vibrational characteristics of aerospace structures at the design and development stage of the production of an aircraft. Modern rotor blade construction methods lead to products with low mass and low inherent damping so careful design and analysis is required to avoid resonance and an undesirable dynamic performance. In addition, accurate modal analysis is necessary for several current approaches in elastic system identification and active control.

McKillip, Robert M., Jr.↗

Novel thermal energy storage component: Development, performance, and phase transition diagnosis

Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Preparing for Mars: the physiologic and medical challenges

As the twentieth century closes, retrospectives cite the Apollo moon missions as one of the important events of the past 100 years. A trip to Mars, however, would be even more challenging and significant. A round-trip Mars journey would require nearly three years away from Earth, a significant leap in complexity compared to the two week long Moon trips or the record-breaking fourteen-month flight on Mir. What would be the physiologic and medical challenges of a Mars flight? Two key areas of physiology present the greatest potential problems--calcium metabolism and radiation exposure. Data from Mir missions show that bone loss continues in space despite an aggressive countermeasure program. Average losses were 0.35% per month, but some load bearing areas lost >1% per month. A 1% loss rate, if it continued unabated for 30 months, could produce osteoporosis. Smaller losses could still increase fracture risk. Some bone loss can be well tolerated, particularly if the bone can be regained after the mission. But the effectiveness of post-flight rehabilitation to restore the density and quality of bone after spaceflight is not well known. Bone loss estimates are based on continuous weightlessness exposure, but this is not a requirement for a Mars trip. Most of the time on a Mars trip will be spent in the 1/3 Earth's gravity environment on Mars, and either intermittent or continuous artificial gravity can be provided for the transit between planets (although at an engineering cost). The dosing of the gravity exposure (e.g. the level and duration), however, has not been established. Radiation protection also requires a balance between engineering cost and human health. Excessive shielding could add billions of dollars to the cost of a mission. Trips in interplanetary space, however, expose the crew to heavy high-energy particles from cosmic rays (HZE particles), which have a high linear energy transfer. This high energy leads to significant biological damage (e.g. chromosomal aberrations, cancer induction). A recent report from the Committee on Space Biology and Medicine notes that only one systematic study of cancer induction from high-energy particles has been conducted (using the mouse Harderian gland). Predictions of cancer risk and acceptable radiation exposure in space are extrapolated from minimal data. Other areas of physiology also present problems, such as muscle loss, cardiovascular deconditioning, and vestibular adaptation. Despite all the issues, however, a focussed, aggressive research program that uses the resources of the International Space Station should pave the way for mankind's greatest adventure--a trip to Mars.

STS-90 Shuttle Project↗

Irrigation Modernization Task 4: Accelerating Energy Solutions (FY2022 Final Report)

This report offers insights on energy solutions for irrigation modernization that serve the needs of farmers as well as residents and industry in the local community. Solutions are found in the irrigation districts where local generation from renewable energy sources – solar, hydro, and wind – can be combined with energy storage and customer loads. These combined resources configured in microgrids can lower costs during peak loads and provide resiliency by maintaining electricity supply during outages. The goal of this project, as stated in the FY2022 AOP, is to promote realization of energy solutions that are tailored to physical location, community, infrastructure, and energy value streams. Further, it is to develop examples of how to increase value of, and overcome barriers to, energy solutions in the context of irrigation modernization. In pursuit of that goal, the project looked at options for: 1) Reducing the cost of energy consumed in irrigation systems, 2) Increasing the revenue from surplus power generation, and 3) Deploying new power generation configured as part of a local microgrid. Potential solutions to reducing energy costs and increasing surplus power revenue revolve around addressing regulatory and legal constraints tied to how power is purchased by and sold to the irrigator or irrigation district. Some headway was made in identifying barriers and ways to push utilities to be more accommodating to distributed energy sources; however, for the most part, real progress hinges on changes at the regulatory and legislative level. Deployment of local, renewable generation systems can be implemented provided the economics of the project and the location are favorable. In concert with Famers Conservation Alliance and Energy Trust of Oregon, a number of approaches were studied in the past year, including off-grid solar powered pumps, grid-tied community solar projects, and in-conduit canal hydropower systems. Ultimately three viable projects were identified: 1) North Unit Irrigation District/City of Redmond, Oregon Critical Facility Microgrid – offers combined in-conduit hydro and solar power generation. 2) Wallowa County/Joseph, Oregon Irrigation System Upgrades – centered on upgrades to a non-powered dam that will add a turbine as well as in-conduit power in canal feeders downstream. 3) Medford, Oregon Wastewater Treatment Plant Biogas Cogeneration System – centered on building out biogas storage and grid upgrades to power the plant, sell excess power, and provide emergency backup power (supplanting a diesel generator). Each of these projects has characteristics that broaden the understanding of the value of microgrids employing renewable energy to achieve resiliency and net-zero carbon goals. The first two projects are centered on new hydropower systems. Although the Medford project is only tangentially tied to an irrigation district, it was selected for study analysis as it was the only one mature enough (with sufficient data) to complete an analysis within this project year. Thus, we chose to move forward developing a case study, in concert with the Community Water-Power Resilience project, to demonstrate a method for evaluating such projects. Essentially, this case study serves as a template for studies to be carried out next year that more directly involve irrigation system hydropower, e.g., the project at the Wallowa County/Joseph, Oregon Irrigation System. Lastly, it is recognized that the locations and case studies in this report are all located in Oregon. We recognize this as a limitation. While the intent is not to ignore other states or regions, this result is driven by the fact that we have cultivated a collaboration with non-profit entities in Oregon that focus on these topics – Farmers Conservation Alliance and Energy Trust of Oregon. These partners were central to identifying projects that may be good fits for this program. A goal in the coming year is to establish collaboration with entities in other states/regions that, similarly, can connect us to potential projects in their geographic area. The potential benefits from the WPTO’s support for demonstration projects as energy solutions in irrigation districts include: (1) Alternative power supplies for communities and farms using renewable, carbon-free energy resources, (2) Cost savings for electricity for communities and farms, (3) Resiliency of power supplies for critical loads when electricity from the grid is not available, (4) Resiliency of power supplies for critical infrastructure in the event of catastrophic events, and (5) Demonstration of irrigation modernization projects that provide resilience and a reduced carbon footprint to irrigation districts and nearby communities. These deployments can serve as vanguards/archetypes spurring similar projects in other districts and states.

13 HYDRO ENERGY↗

Systems Biology-Based Optimization of Extremely Thermophilic Lignocellulose Conversion to Bioproducts

This was a collaborative project involving researchers at the University of Georgia, North Carolina State University, Sanford‐Burnham‐Prebys Med. Discovery Institute and the University of Rhode Island. The over-arching goal was to demonstrate that non-model microorganisms, specifically extreme thermophiles, can be a strategic metabolic engineering platform for industrial biotechnology. We engineered the most thermophilic lignocellulose-degrading organism known, Caldicellulosiruptor bescii (Cbes) , which grows optimally near 80°C, and the most thermophilic fermentative organism known, Pyrococcus furiosus (Pfu) , which grows optimally at 100°C, to produce several key industrial chemicals. This work leveraged recent breakthrough advances in the development of molecular genetic tools for these organisms, complemented by a deep understanding of its metabolism and physiology gained over the past decade of study in the PIs’ laboratories. We applied the latest metabolic reconstruction and modeling approaches to optimize biomass to product conversion. Bio-processing above 70°C can have important advantages over near-ambient operations. Highly genetically-modified microorganisms usually have a fitness disadvantage and can be easily overtaken in culture when contaminating microbes are present. The high growth temperature of extreme thermophiles precludes growth or survival of virtually any contaminating organism or phage. This reduces operating costs associated with reactor sterilization and maintaining a sterile facility. In addition, at industrial scales, heat production from microbial metabolic activity vastly outweighs heat loss through bioreactor walls such that cooling is required. Extreme thermophiles have the advantage that non-refrigerated cooling water can be used if needed, and heating requirements can be met with low-grade steam typically in excess capacity on plant sites. We assembled a highly interdisciplinary team that brought together all of the expertise for the project to have successful outcomes. This project also built upon and utilized extensive information already available in the PIs’ labs for both Cbes and Pfu to develop models that provide a comprehensive description of these organisms’ physiology and metabolism that were utilized to inform metabolic engineering strategies. The models were validated with experimental data and the results demonstrated that unpretreated lignocellulose has the potential to be converted into value-added industrial chemicals at high loading at bioreactor scale. The data generated from this research were published in twenty-one peer-reviewed papers in international journals with online access.

60 APPLIED LIFE SCIENCES↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

An Application of Molecular Recognition for the Efficient Removal of Cesium from Hanford Nuclear Waste by Modular Solvent Extraction

In this work, experimental results leading to flowsheet design are presented showing how a calixarene-crown ether based solvent-extraction process can meet the challenge of cesium removal from nuclear tank wastes stored at the US Department of Energy Hanford site. Cleanup of legacy Cold War nuclear waste stored in underground tanks represents one of the greatest environmental challenges facing the US Department of Energy in terms of risk, cost, and effectiveness of applicable science and technology. Planning for the cleanup at the Hanford Site calls for the removal of the radioactive fission product 137Cs from its alkaline salt waste, including the use of modular processes that can be deployed near the tank farms. To meet the resulting need for extremely high selectivity, the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process employing a calix[4]arene-crown ether in modified kerosene has been adapted to remove sub-millimolar cesium in competition with molar sodium and potassium in a high-nitrate alkaline matrix. Potassium loading in the solvent was determined in extraction, scrubbing, and stripping, leading to an empirical model closely approximating cesium distribution ratios for a variety of Hanford waste types. Process chemistry has been developed based on this molecular-recognition approach, focusing on the competitive effect of potassium loading and the mitigating process modifications needed, including extending the scrub section. The result is a modular flowsheet design that can achieve cesium decontamination factors well in excess of 15,000 even for the worst-case Hanford waste.

Williams, Neil [ORNL] (ORCID:000000023159226X)↗

Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flight demonstration of a self repairing flight control system in a NASA F-15 fighter aircraft

Battle damage causing loss of control capability can compromise mission objectives and even result in aircraft loss. The Self Repairing Flight Control System (SRFCS) flight development program directly addresses this issue with a flight control system design that measures the damage and immediately refines the control system commands to preserve mission potential. The system diagnostics process detects in flight the type of faults that are difficult to isolate post flight, and thus cause excessive ground maintenance time and cost. The control systems of fighter aircraft have the control power and surface displacement to maneuver the aircraft in a very large flight envelope with a wide variation in airspeed and g maneuvering conditions, with surplus force capacity available from each control surface. Digital flight control processors are designed to include built-in status of the control system components, as well as sensor information on aircraft control maneuver commands and response. In the event of failure or loss of a control surface, the SRFCS utilizes this capability to reconfigure control commands to the remaining control surfaces, thus preserving maneuvering response. Correct post-flight repair is the key to low maintainability support costs and high aircraft mission readiness. The SRFCS utilizes the large data base available with digital flight control systems to diagnose faults. Built-in-test data and sensor data are used as inputs to an Onboard Expert System process to accurately identify failed components for post-flight maintenance action. This diagnostic technique has the advantage of functioning during flight, and so is especially useful in identifying intermittent faults that are present only during maneuver g loads or high hydraulic flow requirements. A flight system was developed to test the reconfiguration and onboard maintenance diagnostics concepts on a NASA F-15 fighter aircraft.

Urnes, James M.↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗