Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contour estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The intensity of forbidden torsional transitions in electronic spectra of molecules with a 6-fold barrier: Application to toluenes

Franck-Condon forbidden transitions involving methyl rotor modes are seen in the S{sub 1} ← S{sub 0} spectrum of toluene and toluene-like molecules. The strongest of these rotor transitions (m{sup ″} = 1 → m{sup ′} = 2, m{sup ″} = 0 → m{sup ′} = 3a{sub 1}{sup ″}, and m{sup ″} = 1 → m{sup ′} = 4) have been shown by Walker et al. [J. Chem. Phys. 102, 8718 (1995)] to gain intensity through the rotor equivalent of the Herzberg-Teller mechanism. Despite the m{sup ″} = 0 → m{sup ′} = 3a{sub 2}{sup ″} transition being forbidden in this formalism, it is sporadically observed. We show that this transition derives oscillator strength from incomplete mixing of the −3 and +3 free rotor basis states due to torsion-rotation coupling. Calculations demonstrate that this mechanism quantitatively explains the intensities observed for toluene, including their temperature dependence. Because the −3/+3 mixing is weakest when the torsional barrier height, V{sub 6}, is small, the m{sup ″} = 0 → m{sup ′} = 3a{sub 2}{sup ″} transition increases in intensity as |V{sub 6}| decreases. The temperature and |V{sub 6}| dependencies explain why reports of the 0 → 3a{sub 2}{sup ″} transition have been intermittent. The torsion-rotation coupling mechanism is predicted to also give significant intensity to m = 0 → m = 6a{sub 2}{sup ′} transitions relative to m = 0 → m = 6a{sub 1}{sup ′} transitions and to provide intensity to 0 → 3a{sub 2} transitions in molecules with a 3-fold (V{sub 3}) barrier. Comparison between the observed and calculated rotor band contours shows, unexpectedly, that the 3a{sub 1}{sup ″} constants fail to predict the 3a{sub 2}{sup ″} contour despite these two states being derived from the same free rotor basis states. Comparison with the observed spectrum also reveals differences in the separation of the S{sub 1} 3a{sub 2}{sup ″} and 3a{sub 1}{sup ″} levels. The V{sub 6} value determined from analysis of the high resolution, rotationally resolved m{sup ″} = 0 → m{sup ′} = 3a{sub 1}{sup ″} spectrum overestimates the 3a{sub 2}{sup ″}–3a{sub 1}{sup ″} separation by 0.6 cm{sup −1}. We postulate that this may be due to torsion-vibration coupling. The observed toluene torsion-rotation contours have been modeled to provide estimates of the rotational constants for several of the torsional states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Learning Functions Varying along a Central Subspace

Many functions of interest are in a high-dimensional space but exhibit low-dimensional structures. This paper studies regression of an s-Hölder function in $R^D$ which varies along a central subspace of dimension $d$ while $d \ll D$. A direct approximation of $f$ in $R^D$ with an accuracy $\varepsilon$ requires the number of samples in the order of $\varepsilon^{-(2s+D)/s}$. In this paper, we analyze the generalized contour regression (GCR) algorithm for the estimation of the central subspace and use piecewise polynomials for function approximation. GCR is among the best estimators for the central subspace, but its sample complexity is an open question. In this paper, we partially answer this questions by proving that if a variance quantity is exactly known, GCR leads to a mean squared estimation error of $O(n^{-1})$ for the central subspace. The estimation error of this variance quantity is also given in this paper. The mean squared regression error of $f$ is proved to be in the order of $(n/\log n)^{-\frac{2s}{2s+d}}$, where the exponent depends on the dimension of the central subspace instead of the ambient space . This result demonstrates that GCR is effective in learning the low-dimensional central subspace. We also propose a modified GCR with improved efficiency. Here, the convergence rate is validated through several numerical experiments.

97 MATHEMATICS AND COMPUTING↗

Meteorological atlas of the Northern Hemisphere lower stratosphere for January and February 1989 during the Airborne Arctic Stratospheric Expedition

Northern Hemisphere meteorological data for the months of January and February 1989 in the lower stratosphere are shown. National Meteorological Center (NMC) data, and Total Ozone Mapping Spectrometer (TOMS) data are used to display polar stereographic projections of 100-mb temperatures, 50-mb temperatures, 50-mb geopotential heights, total ozone, and Ertel's potential vorticity (Epv) on both 400 K and 460 K isentropic surfaces. In addition, latitude/height cross sections at 10 E of balanced wind isotachs, wind vectors, potential temperature, and temperature are also shown. Horizontal traces of NASA ER-2 and DC-8 flight tracks are also included. Vertical profiles of NMC temperatures following flight paths of both aircraft are shown. In addition, vertical profiles of wind speed are contoured following the ER-2 for estimating the lateral penetration into the polar vortex, while vertical profiles of Ertel's potential vorticity are included for estimating the vertical penetration of the DC-8 into the stratosphere.

Newman, Paul A.↗

Advanced Multiphysics Thermal-Hydraulics Models for the High Flux Isotope Reactor

Engineering design studies to determine the feasibility of converting the High Flux Isotope Reactor (HFIR) from using highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel are ongoing at Oak Ridge National Laboratory (ORNL). This work is part of an effort sponsored by the US Department of Energy (DOE) Reactor Conversion Program. HFIR is a very high flux pressurized light-water-cooled and moderated flux-trap type research reactor. HFIR s current missions are to support neutron scattering experiments, isotope production, and materials irradiation, including neutron activation analysis. Advanced three-dimensional multiphysics models of HFIR fuel were developed in COMSOL software for safety basis (worst case) operating conditions. Several types of physics including multilayer heat conduction, conjugate heat transfer, turbulent flows (RANS model) and structural mechanics were combined and solved for HFIR s inner and outer fuel elements. Alternate design features of the new LEU fuel were evaluated using these multiphysics models. This work led to a new, preliminary reference LEU design that combines a permanent absorber in the lower unfueled region of all of the fuel plates, a burnable absorber in the inner element side plates, and a relocated and reshaped (but still radially contoured) fuel zone. Preliminary results of estimated thermal safety margins are presented. Fuel design studies and model enhancement continue.

COMSOL↗

High-Grade Glioma Radiation Therapy Target Volumes and Patterns of Failure Obtained From Magnetic Resonance Imaging and {sup 18}F-FDOPA Positron Emission Tomography Delineations From Multiple Observers

Purpose: The objective of this study was to compare recurrent tumor locations after radiation therapy with pretreatment delineations of high-grade gliomas from magnetic resonance imaging (MRI) and 3,4-dihydroxy-6-[{sup 18}F]fluoro-L-phenylalanine ({sup 18}F-FDOPA) positron emission tomography (PET) using contours delineated by multiple observers. Methods and Materials: Nineteen patients with newly diagnosed high-grade gliomas underwent computed tomography (CT), gadolinium contrast-enhanced MRI, and {sup 18}F-FDOPA PET/CT. The image sets (CT, MRI, and PET/CT) were registered, and 5 observers contoured gross tumor volumes (GTVs) using MRI and PET. Consensus contours were obtained by simultaneous truth and performance level estimation (STAPLE). Interobserver variability was quantified by the percentage of volume overlap. Recurrent tumor locations after radiation therapy were contoured by each observer using CT or MRI. Consensus recurrence contours were obtained with STAPLE. Results: The mean interobserver volume overlap for PET GTVs (42% ± 22%) and MRI GTVs (41% ± 22%) was not significantly different (P=.67). The mean consensus volume was significantly larger for PET GTVs (58.6 ± 52.4 cm{sup 3}) than for MRI GTVs (30.8 ± 26.0 cm{sup 3}, P=.003). More than 95% of the consensus recurrence volume was within the 95% isodose surface for 11 of 12 (92%) cases with recurrent tumor imaging. Ten (91%) of these cases extended beyond the PET GTV, and 9 (82%) were contained within a 2-cm margin on the MRI GTV. One recurrence (8%) was located outside the 95% isodose surface. Conclusions: High-grade glioma contours obtained with {sup 18}F-FDOPA PET had similar interobserver agreement to volumes obtained with MRI. Although PET-based consensus target volumes were larger than MRI-based volumes, treatment planning using PET-based volumes may not have yielded better treatment outcomes, given that all but 1 recurrence extended beyond the PET GTV and most were contained by a 2-cm margin on the MRI GTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-108: TMR Correction Factor Based Online Adaptive Radiotherapy for Stereotactic Radiosurgery (SRS) of L-Spine Tumors Using Cone Beam CT

Purpose: To investigate the feasibility of using TMR ratio correction factors for a fast online adaptive plan to compensate for anatomical changes in stereotactic radiosurgery (SRS) of L-spine tumors. Methods: Three coplanar treatment plans were made for 11 patients: Uniform (9 IMRT beams equally distributed around the patient); Posterior (IMRT with 9 posterior beams every 20 degree) and VMAT (2 360° arcs). For each patient, the external body and bowel gas were contoured on the planning CT and pre-treatment CBCT. After registering CBCT and the planning CT by aligning to the tumor, the CBCT contours were transferred to the planning CT. To estimate the actual delivered dose while considering patient’s anatomy of the treatment day, a hybrid CT was created by overriding densities in planning CT using the differences between CT and CBCT external and bowel gas contours. Correction factors (CF) were calculated using the effective depth information obtained from the planning system using the hybrid CT: CF = TMR (delivery)/TMR (planning). The adaptive plan was generated by multiplying the planned Monitor Units with the CFs. Results: The mean absolute difference (MAD) in V16Gy of the target between planned and estimated delivery with and without TMR correction was 0.8 ± 0.7% vs. 2.4 ± 1.3% for Uniform and 1.0 ± 0.9% vs. 2.6 ± 1.3% for VMAT plans(p<0.05), respectively. For V12Gy of cauda-equina with and without TMR correction, MAD was 0.24 ± 0.19% vs. 1.2 ± 1.02% for Uniform and 0.23 ± 0.20% vs. 0.78 ± 0.79% for VMAT plans(p<0.05), respectively. The differences between adaptive and original plans were not significant for posterior plans. Conclusion: The online adaptive strategy using TMR ratios and pre-treatment CBCT information was feasible strategy to compensate for anatomical changes for the patients treated for L-spine tumors, particularly for equally spaced IMRT and VMAT plans.

60 APPLIED LIFE SCIENCES↗

Quantifying Contaminant Mass for the Feasibility Study of the DuPont Chambers Works FUSRAP Site - 13510

The U.S. Army Corps of Engineers (USACE) - Philadelphia District is conducting an environmental restoration at the DuPont Chambers Works in Deepwater, New Jersey under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Discrete locations are contaminated with natural uranium, thorium-230 and radium-226. The USACE is proposing a preferred remedial alternative consisting of excavation and offsite disposal to address soil contamination followed by monitored natural attenuation to address residual groundwater contamination. Methods were developed to quantify the error associated with contaminant volume estimates and use mass balance calculations of the uranium plume to estimate the removal efficiency of the proposed alternative. During the remedial investigation, the USACE collected approximately 500 soil samples at various depths. As the first step of contaminant mass estimation, soil analytical data was segmented into several depth intervals. Second, using contouring software, analytical data for each depth interval was contoured to determine lateral extent of contamination. Six different contouring algorithms were used to generate alternative interpretations of the lateral extent of the soil contamination. Finally, geographical information system software was used to produce a three dimensional model in order to present both lateral and vertical extent of the soil contamination and to estimate the volume of impacted soil for each depth interval. The average soil volume from all six contouring methods was used to determine the estimated volume of impacted soil. This method also allowed an estimate of a standard deviation of the waste volume estimate. It was determined that the margin of error for the method was plus or minus 17% of the waste volume, which is within the acceptable construction contingency for cost estimation. USACE collected approximately 190 groundwater samples from 40 monitor wells. It is expected that excavation and disposal of contaminated soil will remove the contaminant source zone and significantly reduce contaminant concentrations in groundwater. To test this assumption, a mass balance evaluation was performed to estimate the amount of dissolved uranium that would remain in the groundwater after completion of soil excavation. As part of this evaluation, average groundwater concentrations for the pre-excavation and post-excavation aquifer plume area were calculated to determine the percentage of plume removed during excavation activities. In addition, the volume of the plume removed during excavation dewatering was estimated. The results of the evaluation show that approximately 98% of the aqueous uranium would be removed during the excavation phase. The USACE expects that residual levels of contamination will remain in groundwater after excavation of soil but at levels well suited for the selection of excavation combined with monitored natural attenuation as a preferred alternative. (authors)

54 ENVIRONMENTAL SCIENCES↗

FEMA Asteroid Impact Tabletop Exercise Simulations

We describe the computational simulations and damage assessments that we provided in support of a tabletop exercise (TTX) at the request of NASA's Near-Earth Objects Program Office. The overall purpose of the exercise was to assess leadership reactions, information requirements, and emergency management responses to a hypothetical asteroid impact with Earth. The scripted exercise consisted of discovery, tracking, and characterization of a hypothetical asteroid; inclusive of mission planning, mitigation, response, impact to population, infrastructure and GDP, and explicit quantification of uncertainty. Participants at the meeting included representatives of NASA, Department of Defense, Department of State, Department of Homeland Security/Federal Emergency Management Agency (FEMA), and the White House. The exercise took place at FEMA headquarters. Sandia's role was to assist the Jet Propulsion Laboratory (JPL) in developing the impact scenario, to predict the physical effects of the impact, and to forecast the infrastructure and economic losses. We ran simulations using Sandia's CTH hydrocode to estimate physical effects on the ground, and to produce contour maps indicating damage assessments that could be used as input for the infrastructure and economic models. We used the FASTMap tool to provide estimates of infrastructure damage over the affected area, and the REAcct tool to estimate the potential economic severity expressed as changes to GDP (by nation, region, or sector) due to damage and short-term business interruptions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion. Feasibility of delivery to the pulmonary veins and left ventricular myocardium will be investigated in future studies. D. Packer Disclosures: Abiomed, Biosense Webster, Inc., Boston Scientific Corp., CardioFocus, Inc., Johnson and Johnson, Excerpta Medica, Ortho-McNeil-Jannsen, Sanofi Aventis, CardioInsight Technologies, InfoBionic, SIEMENS, Medtronic, Inc., CardioDx, Inc., CardioInsight Technologies, FoxP2 Medica, Mediasphere Medical, Wiley-Blackwell, St. Jude Medical, Endosense, Thermedical, EP Advocate LLC, Hansen Medical, American Heart Association, EpiEP, NIH.

60 APPLIED LIFE SCIENCES↗

SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours

Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure by a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.

60 APPLIED LIFE SCIENCES↗

Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Asymmetry and non-random orientation of the inflight effective beam pattern in the WMAP data

Tentative evidence for statistical anisotropy in the Wilkinson Microwave Anisotropy Probe data was alleged to be due to 'insufficient handling of beam asymmetries'. In this paper, we investigate this issue and develop a method to estimate the shape of the inflight effective beam, particularly the asymmetry and azimuthal orientation. We divide the whole map into square patches and exploit the information in the Fourier space. For patches containing bright extragalactic point sources, we can directly estimate their shapes, from which the inflight effective beam can be estimated. For those without, we estimate the pattern from iso-power contours in two-dimensional Fourier space. We show that the inflight effective beam convolving the signal is indeed non-symmetric for most of the sky, and it is not randomly oriented. Around the ecliptic poles, however, the asymmetry is smaller due to the averaging effect from different orientations of the beam from the scan strategy. The orientations of the effective beam with significant asymmetry are parallel to the lines of ecliptic longitude. In the foreground-cleaned Internal Linear Combination map, however, the systematics caused by beam effect is significantly lessened.

79 ASTRONOMY AND ASTROPHYSICS↗

Lung tumor tracking in fluoroscopic video based on optical flow

Respiratory gating and tumor tracking for dynamic multileaf collimator delivery require accurate and real-time localization of the lung tumor position during treatment. Deriving tumor position from external surrogates such as abdominal surface motion may have large uncertainties due to the intra- and interfraction variations of the correlation between the external surrogates and internal tumor motion. Implanted fiducial markers can be used to track tumors fluoroscopically in real time with sufficient accuracy. However, it may not be a practical procedure when implanting fiducials bronchoscopically. In this work, a method is presented to track the lung tumor mass or relevant anatomic features projected in fluoroscopic images without implanted fiducial markers based on an optical flow algorithm. The algorithm generates the centroid position of the tracked target and ignores shape changes of the tumor mass shadow. The tracking starts with a segmented tumor projection in an initial image frame. Then, the optical flow between this and all incoming frames acquired during treatment delivery is computed as initial estimations of tumor centroid displacements. The tumor contour in the initial frame is transferred to the incoming frames based on the average of the motion vectors, and its positions in the incoming frames are determined by fine-tuning the contour positions using a template matching algorithm with a small search range. The tracking results were validated by comparing with clinician determined contours on each frame. The position difference in 95% of the frames was found to be less than 1.4 pixels ({approx}0.7 mm) in the best case and 2.8 pixels ({approx}1.4 mm) in the worst case for the five patients studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Taming Landau singularities in QCD perturbation theory: The analytic approach 2.0

The aim of this topical article is to outline the fundamental ideas underlying the recently developed Fractional Analytic Perturbation Theory (FAPT) of QCD and present its main calculational tools together with key applications. For this, it is first necessary to review previous methods to apply QCD perturbation theory at low spacelike momentum scales, where the influence of the Landau singularities becomes inevitable. Several concepts are considered and their limitations are pointed out. The usefulness of FAPT is discussed in terms of two characteristic hadronic quantities: the perturbatively calculable part of the pion’s electromagnetic form factor in the spacelike region and the Higgs-boson decay into a b b-bar pair in the timelike region. In the first case, the focus is on the optimization of the prediction with respect to the choice of the renormalization scheme and the dependence on the renormalization and the factorization scales. The second case serves to show that the application of FAPT to this reaction reaches already at the four-loop level an accuracy of the order of 1%, avoiding difficulties inherent in the standard perturbative expansion. The obtained results are compared with estimates from fixed-order and contour-improved QCD perturbation theory. Using the brand-new Higgs mass value of about 125 GeV, measured at the Large Hadron Collider (CERN), a prediction for Γ{sub H→b b-bar }= 2.4 ± 0.15 MeV is extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of propeller/nacelle interactions in the PTA program

Advanced highly-loaded propellers are proposed to power transport aircraft that cruise at high subsonic speeds giving significant fuel savings over the equivalent turbofan engine. In order to realize these savings, the propeller must be installed so that the aerodynamics of the propeller/nacelle combination do not lead to excessive cyclic blade stresses or installation losses. The on-going, NASA sponsored, Propfan Test Assessment Program (PTA) has provided the first high-speed wind-tunnel data on an installed propfan complete with an inlet. This paper presents computational techniques that allow: (1) optimization of inlet plane location, (2) contouring of lip and cowl, and (3) estimation of propeller cyclic loads due to a nonuniform flowfield. These computational methods, in spite of the complexity of the configuration and the slipstream effects, provide predictions of aerodynamic performance which are in excellent agreement with wind-tunnel data.

Aljabri, A. S.↗

Quick look Atlantic Ocean rain maps for gale

A set of quick look maps of Atlantic Ocean rainfall were made. The maps are based entirely on information extracted from geostationary satellite images. The maps and the process by which they were made are briefly described. The major shortcomings of such a project are pointed out. For convenience the maps are presented in rectangular format. Each map covers one day. Rainfall is contoured in units of millimeters. Rainfall was estimated by the Arkin technique.

Martin, David W.↗

Statistical shape model-based reconstruction of a scaled, patient-specific surface model of the pelvis from a single standard AP x-ray radiograph

Purpose: The aim of this article is to investigate the feasibility of using a statistical shape model (SSM)-based reconstruction technique to derive a scaled, patient-specific surface model of the pelvis from a single standard anteroposterior (AP) x-ray radiograph and the feasibility of estimating the scale of the reconstructed surface model by performing a surface-based 3D/3D matching. Methods: Data sets of 14 pelvises (one plastic bone, 12 cadavers, and one patient) were used to validate the single-image based reconstruction technique. This reconstruction technique is based on a hybrid 2D/3D deformable registration process combining a landmark-to-ray registration with a SSM-based 2D/3D reconstruction. The landmark-to-ray registration was used to find an initial scale and an initial rigid transformation between the x-ray image and the SSM. The estimated scale and rigid transformation were used to initialize the SSM-based 2D/3D reconstruction. The optimal reconstruction was then achieved in three stages by iteratively matching the projections of the apparent contours extracted from a 3D model derived from the SSM to the image contours extracted from the x-ray radiograph: Iterative affine registration, statistical instantiation, and iterative regularized shape deformation. The image contours are first detected by using a semiautomatic segmentation tool based on the Livewire algorithm and then approximated by a set of sparse dominant points that are adaptively sampled from the detected contours. The unknown scales of the reconstructed models were estimated by performing a surface-based 3D/3D matching between the reconstructed models and the associated ground truth models that were derived from a CT-based reconstruction method. Such a matching also allowed for computing the errors between the reconstructed models and the associated ground truth models. Results: The technique could reconstruct the surface models of all 14 pelvises directly from the landmark-based initialization. Depending on the surface-based matching techniques, the reconstruction errors were slightly different. When a surface-based iterative affine registration was used, an average reconstruction error of 1.6 mm was observed. This error was increased to 1.9 mm, when a surface-based iterative scaled rigid registration was used. Conclusions: It is feasible to reconstruct a scaled, patient-specific surface model of the pelvis from single standard AP x-ray radiograph using the present approach. The unknown scale of the reconstructed model can be estimated by performing a surface-based 3D/3D matching.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The estimation of Poisson’s ratio by time-averaging and Cornu’s method for isotropic beams

Prior research suggests that direct static (e.g., uniaxial testing) and dynamic (e.g., ultrasonic wave propagation analysis) measurements differ in the estimation of Poisson’s ratio because anisotropies and heterogeneities in the sample material affect the two types of tests differently. Even assuming isotropic and homogeneous material properties, prior research further suggests that discrepancies between static/dynamic test results will exist because the error of the diagnostic techniques for the measurand are inherently different. Finally, thermodynamic effects are not present in static tests but can significantly affect dynamic test results. Given the potential for all these variables to produce discrepancies, it would be helpful to have the measurement of Poisson’s ratio obtainable from the same theory and experimental measurements by either static or dynamic testing methods. Our finite element calculations show that by combining time-averaged scanning digital holography with Cornu’s method, it is theoretically possible to estimate the effective Poisson’s ratio from the anticlastic contours at the antinode of the first out-of-plane bending mode shape. This is true regardless of frequency and therefore applicable for both static and dynamic measurements. Our results show that the estimate of Poisson’s ratio by Cornu’s method using data from simulations of mode shapes approaches the true value of Poisson’s ratio. Additionally, our research suggests that beam geometry and boundary conditions are fundamental factors limiting the convergence of the estimate of Poisson’s ratio to the true value of Poisson’s ratio regardless of performing a static or dynamic test.

42 ENGINEERING↗