Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “concurrent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Concurrent Chemo-Radiation With or Without Induction Gemcitabine, Carboplatin, and Paclitaxel: A Randomized, Phase 2/3 Trial in Locally Advanced Nasopharyngeal Carcinoma

Purpose: To compare survival, tumor control, toxicities, and quality of life of patients with locally advanced nasopharyngeal carcinoma (NPC) treated with induction chemotherapy and concurrent chemo-radiation (CCRT), against CCRT alone. Patients and Methods: Patients were stratified by N stage and randomized to induction GCP (3 cycles of gemcitabine 1000 mg/m{sup 2}, carboplatin area under the concentration-time-curve 2.5, and paclitaxel 70 mg/m{sup 2} given days 1 and 8 every 21 days) followed by CCRT (radiation therapy 69.96 Gy with weekly cisplatin 40 mg/m{sup 2}), or CCRT alone. The accrual of 172 was planned to detect a 15% difference in 5-year overall survival (OS) with a 5% significance level and 80% power. Results: Between September 2004 and August 2012, 180 patients were accrued, and 172 (GCP 86, control 86) were analyzed by intention to treat. There was no significant difference in OS (3-year OS 94.3% [GCP] vs 92.3% [control]; hazard ratio 1.05; 1-sided P=.494]), disease-free survival (hazard ratio 0.77, 95% confidence interval 0.44-1.35, P=.362), and distant metastases–free survival (hazard ratio 0.80, 95% confidence interval 0.38-1.67, P=.547) between the 2 arms. Treatment compliance in the induction phase was good, but the relative dose intensity for concurrent cisplatin was significantly lower in the GCP arm. Overall, the GCP arm had higher rates of grades 3 and 4 leukopenia (52% vs 37%) and neutropenia (24% vs 12%), but grade 3 and 4 acute radiation toxicities were not statistically different between the 2 arms. The global quality of life scores were comparable in both arms. Conclusion: Induction chemotherapy with GCP before concurrent chemo-irradiation did not improve survival in locally advanced NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Radiation Therapy to the Primary Tumor With Concurrent Chemotherapy in Patients With Stage IV Non-Small Cell Lung Cancer: Results of a Multicenter Phase 2 Study From PPRA-RTOG, China

Purpose: The aim of this prospective multi-institutional phase 2 study was to investigate disease control, survival outcomes, and toxicity after thoracic three-dimensional radiation therapy (3D-RT) with concurrent chemotherapy for newly diagnosed stage IV non-small cell lung cancer (NSCLC). Methods and Materials: Eligible patients were 18 to 80 years of age, had a Karnofsky performance status (KPS) score ≥70%, and newly diagnosed stage IV NSCLC with limited metastatic disease (defined as involving ≤3 organs). Patients received platinum-doublet chemotherapy with concurrent irradiation to the primary tumor. Primary endpoints were overall survival (OS) and acute toxicity. Results: From May 2008 to May 2012, 198 eligible patients were enrolled from 7 cancer centers. Most patients died with distant metastasis; only 10% died with isolated primary recurrence. Median OS time was 13.0 months (95% confidence interval [CI]: 11.7-14.3); OS rates were 53.5% at 1 year, 15.8% at 2 years, and 9.2% at 3 years. Median progression-free survival (PFS) time was 9.0 months (95% CI: 7.7-10.3); corresponding PFS rates were 30.8%, 8.2%, and 6.1%. The 1-year, 2-year, and 3-year local (primary tumor) control rates were 78.8%, 57.7%, and 55.4%. Multivariate analysis showed that delivery of ≥63 Gy to the primary tumor (P=.014), having a primary tumor volume <134 cm{sup 3} (P=.008), and having a stable or higher KPS score after treatment (P=.01) were independent predictors of better OS. The most common severe (grades 3-4) acute toxicities were hematologic: leukopenia (37.9%), thrombocytopenia (10.1%), and anemia (6.9%). No patients experienced grade 4 or 5 radiation-related toxicity; 2.5% had acute grade 3 pneumonitis, and 6.6% had acute grade 3 radiation esophagitis. Conclusions: Thoracic 3D-RT to the primary tumor with concurrent chemotherapy led to satisfactory survival outcomes with acceptable toxicity. Radiation dose, primary tumor volume, and PFS after treatment all predicted survival in these patients with limited-metastasis NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Dose Escalation Study of Accelerated Radiation Therapy With Concurrent Chemotherapy for Locally Advanced Lung Cancer

Purpose: To determine the maximum tolerated dose of radiation therapy (RT) given in an accelerated fashion with concurrent chemotherapy using intensity modulated RT. Methods and Materials: Patients with locally advanced lung cancer (non-small cell and small cell) with good performance status and minimal weight loss received concurrent cisplatin and etoposide with RT. Intensity modulated RT with daily image guidance was used to facilitate esophageal avoidance and delivered using 6 fractions per week (twice daily on Fridays with a 6-hour interval). The dose was escalated from 58 Gy to a planned maximum dose of 74 Gy in 4 Gy increments in a standard 3 + 3 trial design. Dose-limiting toxicity (DLT) was defined as acute grade 3-5 nonhematologic toxicity attributed to RT. Results: A total of 24 patients were enrolled, filling all dose cohorts, all completing RT and chemotherapy as prescribed. Dose-limiting toxicity occurred in 1 patient at 58 Gy (grade 3 esophagitis) and 1 patient at 70 Gy (grade 3 esophageal fistula). Both patients with DLTs had large tumors (12 cm and 10 cm, respectively) adjacent to the esophagus. Three additional patients were enrolled at both dose cohorts without further DLT. In the final 74-Gy cohort, no DLTs were observed (0 of 6). Conclusions: Dose escalation and acceleration to 74 Gy with intensity modulated RT and concurrent chemotherapy was tolerable, with a low rate of grade ≥3 acute esophageal reactions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase 2 Trial of Concurrent Chemotherapy and Proton Therapy for Stage III Non-Small Cell Lung Cancer: Results and Reflections Following Early Closure of a Single-Institution Study

Purpose: Proton therapy has been shown to reduce radiation dose to organs at risk (OAR) and could be used to safely escalate the radiation dose. We analyzed outcomes in a group of phase 2 study patients treated with dose-escalated proton therapy with concurrent chemotherapy for stage 3 non-small cell lung cancer (NSCLC). Methods and Materials: From 2009 through 2013, LU02, a phase 2 trial of proton therapy delivering 74 to 80 Gy at 2 Gy/fraction with concurrent chemotherapy for stage 3 NSCLC, was opened to accrual at our institution. Due to slow accrual and competing trials, the study was closed after just 14 patients (stage IIIA, 9 patients; stage IIIB, 5 patients) were accrued over 4 years. During that same time period, 55 additional stage III patients were treated with high-dose proton therapy, including 7 in multi-institutional proton clinical trials, 4 not enrolled due to physician preference, and 44 who were ineligible based on strict entry criteria. An unknown number of patients were ineligible for enrollment due to insurance coverage issues and thus were treated with photon radiation. Median follow-up of surviving patients was 52 months. Results: Two-year overall survival and progression-free survival rates were 57% and 25%, respectively. Median lengths of overall survival and progression-free survival were 33 months and 14 months, respectively. There were no acute grade 3 toxicities related to proton therapy. Late grade 3 gastrointestinal toxicity and pulmonary toxicity each occurred in 1 patient. Conclusions: Dose-escalated proton therapy with concurrent chemotherapy was well tolerated with encouraging results among a small cohort of patients. Unfortunately, single-institution proton studies may be difficult to accrue and consideration for pragmatic and/or multicenter trial design should be considered when developing future proton clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon Ion Radiation Therapy With Concurrent Gemcitabine for Patients With Locally Advanced Pancreatic Cancer

Purpose: To determine, in the setting of locally advanced pancreatic cancer, the maximum tolerated dose of carbon ion radiation therapy (C-ion RT) and gemcitabine dose delivered concurrently and to estimate local effect and survival. Methods and Materials: Eligibility included pathologic confirmation of pancreatic invasive ductal carcinomas and radiographically unresectable disease without metastasis. Concurrent gemcitabine was administered on days 1, 8, and 15, and the dose levels were escalated from 400 to 1000 mg/m{sup 2} under the starting dose level (43.2 GyE) of C-ion RT. The dose levels of C-ion RT were escalated from 43.2 to 55.2 GyE at 12 fractions under the fixed recommended gemcitabine dose determined. Results: Seventy-six patients were enrolled. Among the 72 treated patients, dose-limiting toxicity was observed in 3 patients: grade 3 infection in 1 patient and grade 4 neutropenia in 2 patients. Only 1 patient experienced a late grade 3 gastric ulcer and bleeding 10 months after C-ion RT. The recommended dose of gemcitabine with C-ion RT was found to be 1000 mg/m{sup 2}. The dose of C-ion RT with the full dose of gemcitabine (1000 mg/m{sup 2}) was safely increased to 55.2 GyE. The freedom from local progression rate was 83% at 2 years using the Response Evaluation Criteria in Solid Tumors. The 2-year overall survival rates in all patients and in the high-dose group with stage III (≥45.6 GyE) were 35% and 48%, respectively. Conclusions: Carbon ion RT with concurrent full-dose gemcitabine was well tolerated and effective in patients with unresectable locally advanced pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vorinostat and Concurrent Stereotactic Radiosurgery for Non-Small Cell Lung Cancer Brain Metastases: A Phase 1 Dose Escalation Trial

Purpose: To determine the maximum tolerated dose (MTD) of vorinostat, a histone deacetylase inhibitor, given concurrently with stereotactic radiosurgery (SRS) to treat non-small cell lung cancer (NSCLC) brain metastases. Secondary objectives were to determine toxicity, local failure, distant intracranial failure, and overall survival rates. Materials and Methods: In this multicenter study, patients with 1 to 4 NSCLC brain metastases, each ≤2 cm, were enrolled in a phase 1, 3 + 3 dose escalation trial. Vorinostat dose levels were 200, 300, and 400 mg orally once daily for 14 days. Single-fraction SRS was delivered on day 3. A dose-limiting toxicity (DLT) was defined as any Common Terminology Criteria for Adverse Events version 3.0 grade 3 to 5 acute nonhematologic adverse event related to vorinostat or SRS occurring within 30 days. Results: From 2009 to 2014, 17 patients were enrolled and 12 patients completed study treatment. Because no DLTs were observed, the MTD was established as 400 mg. Acute adverse events were reported by 10 patients (59%). Five patients discontinued vorinostat early and withdrew from the study. The most common reasons for withdrawal were dyspnea (n=2), nausea (n=1), and fatigue (n=2). With a median follow-up of 12 months (range, 1-64 months), Kaplan-Meier overall survival was 13 months. There were no local failures. One patient (8%) at the 400-mg dose level with a 2.0-cm metastasis developed histologically confirmed grade 4 radiation necrosis 2 months after SRS. Conclusions: The MTD of vorinostat with concurrent SRS was established as 400 mg. Although no DLTs were observed, 5 patients withdrew before completing the treatment course, a result that emphasizes the need for supportive care during vorinostat administration. There were no local failures. A larger, randomized trial may evaluate both the tolerability and potential local control benefit of vorinostat concurrent with SRS for brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent reaction-bonded joining and densification of additively manufactured silicon carbide by liquid silicon infiltration

Here, in this study, additive-manufactured silicon carbide preforms were joined and densified by reaction bonding via liquid silicon infiltration. The silicon carbide preforms were first printed by binder jetting additive manufacturing. To demonstrate concurrent joining and densification, two preforms with carbon or parchment papers at the interface were concurrently joined and infiltrated by liquid silicon. Results showed a robust interface with thicknesses ranging from 150 to 500 µm, depending on the paper type and the number of paper layers. High-energy synchrotron X-ray revealed that β-phase silicon carbide was formed inside the interface. Finally, two additively manufactured samples with complicated channel geometry were successfully joined. Energy dispersive spectroscopy of the interface of the channeled samples showed a consistent and robust joining. This concurrent approach of joining and densification enables efficiency improvement of fabricating silicon carbide parts with complicated geometries and widens geometry freedom for additive manufacturing of silicon carbide.

36 MATERIALS SCIENCE↗

A comparative study of concurrence and negativity of general three-level quantum systems of two particles

Quantum entanglement is at the heart of quantum information processing. Ordering the quantum systems due to their entanglement is a popular problem of the field. For two level (qubit) systems of two particles, state ordering has been studied with respect to well-known entanglement measures such as Concurrence, Negativity and Relative Entropy of Entanglement (REE) [1-5]. In this work, we study the state ordering of the three-level quantum systems of two particles with respect to Concurrence and Negativity. In particular, constructing 10K random states and calculating their Concurrences and Negativities, we obtain the orderings of the states and present our results which are interesting when compared to that of two-level systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Concurrent atomistic-continuum modeling of crystalline materials

In the work reported here, we present a concurrent atomistic-continuum (CAC) method for modeling and simulation of crystalline materials. The CAC formulation extends the Irving-Kirkwood procedure for deriving transport equations and fluxes for homogenized molecular systems to that for polyatomic crystalline materials by employing a concurrent two-level description of the structure and dynamics of crystals. A multiscale representation of conservation laws is formulated, as a direct consequence of Newton's second law, in terms of instantaneous expressions of unit cell-averaged quantities using the mathematical theory of distributions. Finite element (FE) solutions to the conservation equations, as well as fluxes and temperature in the FE representation, are introduced, followed by numerical examples of the atomic-scale structure of interfaces, dynamics of fracture and dislocations, and phonon thermal transport across grain boundaries. In addition to providing a methodology for concurrent multiscale simulation of transport processes under a single theoretical framework, the CAC formulation can also be used to compute fluxes (stress and heat flux) in atomistic and coarse-grained atomistic simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of particle in cell methods on highly concurrent computational architectures

Particle in cell (PIC) methods are effective in computing Vlasov-Poisson system of equations used in simulations of magnetic fusion plasmas. PIC methods use grid based computations, for solving Poisson’s equation or more generally Maxwell’s equations, as well as Monte-Carlo type methods to sample the Vlasov equation. The presence of two types of discretizations, deterministic field solves and Monte-Carlo methods for the Vlasov equation, pose challenges in understanding and optimizing performance on today large scale computers which require high levels of concurrency. These challenges arises from the need to optimize two very different types of processes and the interactions between them. Modern cache based high-end computers have very deep memory hierarchies and high degrees of concurrency which must be utilized effectively to achieve good performance. The effective use of these machines requires maximizing concurrency by eliminating serial or redundant work and minimizing global communication. A related issue is minimizing the memory traffic between levels of the memory hierarchy because performance is often limited by the bandwidths and latencies of the memory system. This paper discusses some of the performance issues, particularly in regard to parallelism, of PIC methods. The gyrokinetic toroidal code (GTC) is used for these studies and a new radial grid decomposition is presented and evaluated. Scaling of the code is demonstrated on ITER sized plasmas with up to 16K Cray XT3/4 cores.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Changes in Concurrent Precipitation and Temperature Extremes

While numerous studies have addressed changes in climate extremes, analyses of concurrence of climate extremes are scarce, and climate change effects on joint extremes are rarely considered. This study assesses the occurrence of joint (concurrent) monthly continental precipitation and temperature extremes in Climate Research Unit (CRU) and University of Delaware (UD) observations, and in 13 Coupled Model Intercomparison Project Phase 5 (CMIP5) global climate simulations. Moreover, the joint occurrences of precipitation and temperature extremes simulated by CMIP5 climate models are compared with those derived from the CRU and UD observations for warm/wet, warm/dry, cold/wet, and cold/dry combinations of joint extremes. The number of occurrences of these four combinations during the second half of the 20th century (1951–2004) is assessed on a common global grid. CRU and UD observations show substantial increases in the occurrence of joint warm/dry and warm/wet combinations for the period 1978–2004 relative to 1951–1977. The results show that with respect to the sign of change in the concurrent extremes, the CMIP5 climate model simulations are in reasonable overall agreement with observations. The results reveal notable discrepancies between regional patterns and the magnitude of change in individual climate model simulations relative to the observations of precipitation and temperature.

54 ENVIRONMENTAL SCIENCES↗

Lower bound on concurrence and distillation for arbitrary-dimensional bipartite quantum states

We present a lower bound of concurrence for arbitrary-dimensional bipartite quantum states. This lower bound may be used to improve all the known lower bounds of concurrence. Moreover, the lower bound gives rise to an operational sufficient criterion of distillability of quantum entanglement. The significance of our result is illustrated by quantitative evaluation of entanglement for entangled states that fail to be identified by the usual concurrence estimation method and by showing the distillability of mixed states that cannot be recognized by other distillability criteria.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

STU attractors from vanishing concurrence

Concurrence is an entanglement measure characterizing the mixed state bipartite correlations inside of a pure state of an n-qubit system. We show that after organizing the charges and the moduli in the STU model of N=2, d=4 supergravity to a three-qubit state, for static extremal spherically symmetric Bogomolny-Prasad-Sommerfield (BPS) black-hole solutions the vanishing condition for all of the bipartite concurrences on the horizon is equivalent to the attractor equations. As a result of this, the macroscopic black hole entropy given by the three-tangle can be reinterpreted as a linear entropy characterizing the pure state entanglement for an arbitrary bipartite split. Both for the BPS and non-BPS cases, explicit expressions for the concurrences are obtained, with their vanishing on the horizon is demonstrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Concurrent conversation modeling and parallel simulation of the naming game in social networks

The Naming Game is an effective self-organization model to understand the emergence of linguistic consensus and to investigate the system dynamics in a variety of phenomena over social networks of autonomous agents. The Naming Game is an effective description for the evolution of consensus despite the absence of any central coordination or specialized initialization even in large-scale networks. While the classical game is effective in description, it was defined with inherently sequential evaluation semantics over the entire network. Here, we develop a new concurrent model as a relaxation of the classical formulation and express it in a discrete event style of evaluation. Further, with the uncovered concurrency that was absent in the classical algorithm, we map the concurrent model to parallel discrete event simulation. Using a prototype implementation, we present an initial parallel performance study on networks containing hundreds of thousands of individuals, with a decrease in simulation time in the best-observed case from 4800 seconds down to 1400 seconds.

Perumalla, Kalyan↗

Positioning Accuracy in a Concurrent Robot-CNC Hybrid Manufacturing System

Abstract Additive manufacturing (AM) has gained notoriety for offering advantages over traditional manufacturing methods, such as increased design complexity and flexibility. However, it has not found widespread use beyond rapid prototyping. One hindrance to the acceptance of AM processes in industry is the time and cost of fabrication per component. While metal AM by itself can be inexpensive, extra manufacturing steps in the form of subtractive manufacturing (SM) may need to be performed to reach final part tolerances, leading to hybrid additive-subtractive manufacturing (HASM) of a part, which increases time and cost. A potential area to reduce cost is through increasing the efficiency of the HASM process by conducting additive and subtractive manufacturing simultaneously. Usually, HASM is performed in a process where AM is completed in one machine or cell and transferred to another machine or cell for SM in a sequential assembly line process. This efficiency decreases part cost, but high aspect ratio parts or parts with internal geometry that require interleaved additive deposition and machining cannot be produced. One unexplored solution to simultaneous HASM that allows for interleaved operations is to operate the deposition head and machining spindle concurrently within the same machine envelope, known as concurrent HASM (CHASM). In this type of process, both AM and SM occur simultaneously on a batch of small parts or a single large part, maintaining a high efficiency without sacrificing the full range of complex geometries that AM allows for. A potential approach to the single-machine method could be to combine a robot and mill within the same envelope. A challenge to this approach, however, is control of both systems. Most machine controllers have limited external communication or, if a robot has been integrated, only offer movement of either the robot or mill at any given time. As a result, systems must pause either the AM or SM process to switch between them rather than working simultaneously. The present work investigates the positional accuracy of such a CHASM system comprised of a robotic arm and a 3-axis mill. Open-loop tests with limited communication between machines are performed on the system to verify positional error during concurrent robot-mill movements. Under certain conditions, it is demonstrated that position error can stay within 2 mm for the duration of a single layer; however, these tests show that, generally, the open-loop positioning performance of the system is inadequate for CHASM without part-specific hand-tuning of parameters. Based on these results, a set of requirements for successful robot-CNC CHASM is proposed for future integrations.

Goodwin, Jesse↗

Concurrent segmentation of the prostate on MRI and CT via linked statistical shape models for radiotherapy planning

Purpose: Prostate gland segmentation is a critical step in prostate radiotherapy planning, where dose plans are typically formulated on CT. Pretreatment MRI is now beginning to be acquired at several medical centers. Delineation of the prostate on MRI is acknowledged as being significantly simpler to perform, compared to delineation on CT. In this work, the authors present a novel framework for building a linked statistical shape model (LSSM), a statistical shape model (SSM) that links the shape variation of a structure of interest (SOI) across multiple imaging modalities. This framework is particularly relevant in scenarios where accurate boundary delineations of the SOI on one of the modalities may not be readily available, or difficult to obtain, for training a SSM. In this work the authors apply the LSSM in the context of multimodal prostate segmentation for radiotherapy planning, where the prostate is concurrently segmented on MRI and CT. Methods: The framework comprises a number of logically connected steps. The first step utilizes multimodal registration of MRI and CT to map 2D boundary delineations of the prostate from MRI onto corresponding CT images, for a set of training studies. Hence, the scheme obviates the need for expert delineations of the gland on CT for explicitly constructing a SSM for prostate segmentation on CT. The delineations of the prostate gland on MRI and CT allows for 3D reconstruction of the prostate shape which facilitates the building of the LSSM. In order to perform concurrent prostate MRI and CT segmentation using the LSSM, the authors employ a region-based level set approach where the authors deform the evolving prostate boundary to simultaneously fit to MRI and CT images in which voxels are classified to be either part of the prostate or outside the prostate. The classification is facilitated by using a combination of MRI-CT probabilistic spatial atlases and a random forest classifier, driven by gradient and Haar features. Results: The authors acquire a total of 20 MRI-CT patient studies and use the leave-one-out strategy to train and evaluate four different LSSMs. First, a fusion-based LSSM (fLSSM) is built using expert ground truth delineations of the prostate on MRI alone, where the ground truth for the gland on CT is obtained via coregistration of the corresponding MRI and CT slices. The authors compare the fLSSM against another LSSM (xLSSM), where expert delineations of the gland on both MRI and CT are employed in the model building; xLSSM representing the idealized LSSM. The authors also compare the fLSSM against an exclusive CT-based SSM (ctSSM), built from expert delineations of the gland on CT alone. In addition, two LSSMs trained using trainee delineations (tLSSM) on CT are compared with the fLSSM. The results indicate that the xLSSM, tLSSMs, and the fLSSM perform equivalently, all of them out-performing the ctSSM. Conclusions: The fLSSM provides an accurate alternative to SSMs that require careful expert delineations of the SOI that may be difficult or laborious to obtain. Additionally, the fLSSM has the added benefit of providing concurrent segmentations of the SOI on multiple imaging modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-BRE-04: Modeling Optimal Concurrent Chemotherapy Schedules

Purpose: Concurrent chemo-radiation therapy (CCRT) has become a more common cancer treatment option with a better tumor control rate for several tumor sites, including head and neck and lung cancer. In this work, possible optimal chemotherapy schedules were investigated by implementing chemotherapy cell-kill into a tumor response model of RT. Methods: The chemotherapy effect has been added into a published model (Jeong et al., PMB (2013) 58:4897), in which the tumor response to RT can be simulated with the effects of hypoxia and proliferation. Based on the two-compartment pharmacokinetic model, the temporal concentration of chemotherapy agent was estimated. Log cell-kill was assumed and the cell-kill constant was estimated from the observed increase in local control due to concurrent chemotherapy. For a simplified two cycle CCRT regime, several different starting times and intervals were simulated with conventional RT regime (2Gy/fx, 5fx/wk). The effectiveness of CCRT was evaluated in terms of reduction in radiation dose required for 50% of control to find the optimal chemotherapy schedule. Results: Assuming the typical slope of dose response curve (γ50=2), the observed 10% increase in local control rate was evaluated to be equivalent to an extra RT dose of about 4 Gy, from which the cell-kill rate of chemotherapy was derived to be about 0.35. Best response was obtained when chemotherapy was started at about 3 weeks after RT began. As the interval between two cycles decreases, the efficacy of chemotherapy increases with broader range of optimal starting times. Conclusion: The effect of chemotherapy has been implemented into the resource-conservation tumor response model to investigate CCRT. The results suggest that the concurrent chemotherapy might be more effective when delayed for about 3 weeks, due to lower tumor burden and a larger fraction of proliferating cells after reoxygenation.

60 APPLIED LIFE SCIENCES↗

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

60 APPLIED LIFE SCIENCES↗