Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compute tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Model studies of laser absorption computed tomography for remote air pollution measurement

Model studies of the potential of laser absorption-computed tomography are presented which demonstrate the possibility of sensitive remote atmospheric pollutant measurements, over kilometer-sized areas, with two-dimensional resolution, at modest laser source powers. An analysis of this tomographic reconstruction process as a function of measurement SNR, laser power, range, and system geometry, shows that the system is able to yield two-dimensional maps of pollutant concentrations at ranges and resolutions superior to those attainable with existing, direct-detection laser radars.

Wolfe, D. C., Jr.↗

Assessment of Localized Deformations in Sand Using X-Ray Computed Tomography

The internal fabric and localized deformation patterns of triaxial sand specimens were investigated using Computed Tomography (CT). Three displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses (0.05, 0.52, and 1.30 kPa) in a microgravity environment aboard the Space Shuttle during the NASA STS-79 mission. CT scanning was p'erformed on these flight specimens, as well as on an uncompressed specimen and a specimen tested in a terrestrial laboratory at 1.30 kPa effective confining stress. CT demonstrated high accuracy in detecting specimen inhomogeneity and localization patterns. Formation of deformation patterns is dependent on the effective confining stress and gravity. Multiple symmetrical radial shear bands were observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Nonsymmetrical spatial deformation was observed in the 1-G specimen. Analysis tools were developed to quantify the spatial density change. Void ratio variation within and outside the shear bands was calculated and discussed.

Alshibli, Khalid A↗

Impacts of Biomass Feedstock Pre-Processing on Heat and Mass Transfer During Pyrolysis Using X-Ray Computed Tomography and Multiscale Modeling

Knowledge of the transport properties of biomass particles such as porosity, tortuosity, and permeability is paramount for high-fidelity modeling of biomass pyrolysis due to the heat and mass transfer limitations imposed by particle microstructure. X-ray computed tomography (XCT) is a non-destructive imaging method that enables full 3D reconstructions of the biomass particle microstructure with high resolution, permitting direct calculation of porosity, tortuosity, and permeability from real particle geometries. In this study, XCT imaging revealed the 3D microstructures of particles and chars from pyrolytic conversion of cylindrically cut or milled/pelletized loblolly pine samples. The porosity, tortuosity, and permeability were calculated directly from the XCT geometries via open-source microstructural analysis tool MATBOX+TauFactor (https://github.com/NREL/MATBOX_Microstructure_analysis_toolbox) and computational fluid dynamics (CFD) simulations using our solver, Mesoflow (https://github.com/NREL/mesoflow). These properties were used in a reactor scale model developed in COMSOL of the single particle reactor at NREL to investigate the impact of feedstock pre-processing on biomass conversion during pyrolysis with rigorous experimental validation.

biomass↗

Quantitative Computer Tomography for Determining Composition of Microgravity and Ground Based Solid Solutions

Advances in x-ray Computer Tomography (CT) have been led by the medical profession, and by evaluation of industrial products, particularly castings. Porosity can readily be determined as a function of the density of a material, and CT is thus an industrially important NDE tool. Providing high purity, 100% dense standards of pure elements and compounds can be fabricated, the composition of solid solution alloys can be determined by measuring the CT number, which is a function of the absorption of the sample. Average densities across slices 1 mm thick can generally be determined to better than 1 percent. With present technology this spatial sensitivity is less than ideal, but important benefits can nevertheless be obtained by using CT, particularly single crystals, prior to making any destructive assault upon the sample. The sample can in fact be examined prior to removal from the mold within which it has been grown and, in the cases of microgravity flight samples, before removal from the cartridge assembly. This greatly assists the researcher in the characterization of the products, particularly as a guide to cutting and sampling. Examples of work with germanium-silicon alloys and mercury cadmium telluride taken with a radioactive cobalt source will be demonstrated.

Gillies, D. C.↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Post-irradiation examination of AGR-3/4 TRISO fuel compacts using three-dimensional X-ray computed tomography

The AGR-3/4 irradiation tests combined the third and fourth planned irradiation experiments in the US Department of Energy’s Advanced Gas Reactor (AGR) testing campaign of tri-structural isotropic (TRISO) fuel compacts. In this article, we present post-irradiation examination (PIE) using X-ray computed tomography (XCT) of two unirradiated and two irradiated compacts from the AGR-3/4 irradiation tests. The irradiated compacts studied (compact 7–1 and compact 12–4) represent the upper and lower limit of burnup within the AGR-3/4 irradiation experiment. This article presents a detailed quantitative analysis on the post-irradiation structure of TRISO fuel compacts. Various quantitative parameters including shape, size, and packing of kernels, and their spatial distribution, were utilized to gain insights into the structural changes caused by irradiation. The equivalent diameter and sphericity were found to increase and decrease, respectively, in irradiated compact 7–1 due to its higher burnup. Nearest neighbor distance between fuel kernels decreased after irradiation, suggesting irradiation-induced shrinkage of graphitic matrix. Furthermore, each compact in AGR-3/4 irradiation tests contained 20 designed-to-fail (DTF) fuel particles that were meant to act as a source of fission product release to the experiment test train. Furthermore, in the present work, all DTF fuel particles in the four compacts studied were identified, and it was found that they exhibited larger kernel swelling in compact 12–4 and smaller kernel swelling in compact 7–1, compared to the driver particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Computed Tomography and its Application for the 3D Characterization of Coarse Grained Meteorites

With judicious selection of parameters, computed tomography can provide high precision density data. Such data can lead to a non-destructive determination of the phases and phase distribution within large solid objects. Of particular interest is the structure of the Mundrabilla meteorite, which has 25 volumes, percent of a sulfide within a metallic meteorite. 3D digital imaging has enabled a quantitative evaluation of the distribution and contiguity of the phases to be determined.

Gillies, Donald C.↗

Defect And Damage Characterization Of Additively Manufactured Titanium Alloy Ti-5553 Using Traditional Computed Tomography Volume Segmentation And Machine Learning Algorithms

The mechanical response of a component is affected by defects, such as porosity, arising from the laser powder bed fusion (LPBF) fabrication process. Thus, it is important to develop accurate and efficient inspection methods for identifying porosity. In this work, porosity identified in an X-ray computed tomography (XCT) volume of a Ti-5553 coupon was compared to pores identified in a serial sectioned volume that represented the ground truth. The porosity of the XCT scan was identified using contrast-based, ISO-based, and machine learning (ML) methods for segmentation. Large inherent porosity was easy to identify, but the ISO thresholding still struggled due to the intensity gradient resulting from both the beam hardening in XCT and the uneven lighting of the serial sectioning panels. Further, the results show that ML-based methods were better suited for identifying small pores and reducing the amount of false positives. Additionally, high strain-rate impact testing was done on some of the XCT samples as well as post-mortem XCT inspection, and the same suite of segmentation and quantification tools were used to identify the large spallation cavities. The comparison of porosity pre- and post-mortem provides insight on the influence of the LPBF porosity on the formation of spall cavities.

36 MATERIALS SCIENCE↗

Measuring thermal curing induced shrinkage of material extrusion based additive manufacturing silicone elastomer lattices by X-ray computed tomography

Thermal curing induces shrinkage in material extrusion based additive manufacturing silicone elastomer samples, resulting in discrepancies between as printed and final geometries. Knowing the extent to which the samples change in shape and size allows us to make appropriate modifications to the printing design to better control the geometry of the samples. We present an X-ray computed tomography (CT) based approach to determine filament-level shrinkage due to thermal curing of silicone elastomer samples printed with direct ink writing (DIW). The approach relies on custom-designed build plates that are resistant to the elevated curing temperatures and that have sufficiently distinct X-ray absorption characteristics from the silicone elastomer to ensure adequate segmentation of the latter in X-ray imaging data. We implement the approach to evaluate shrinkage in DIW ‘log pile’ samples with three distinct strand arrangements and demonstrate of how filament-level information can be extracted from the X-ray CT data.

Additive manufacturing↗

Fabrication of a Point-Like Transmission Target for Reducing Computed Tomography Imaging Artifacts

In this study, we address the challenge of enhancing image quality and spatial resolution in computed tomography (CT) imaging by introducing simulation and fabrication of high aspect ratio, point-like transmission targets. Utilizing advanced electroplating techniques, traditionally employed in the fabrication of Through Substrate Via (TSV) interconnects for CMOS circuitry, we successfully embed copper targets within silicon substrates. This method allows us to create high-aspect-ratio features specifically designed for X-ray transmission targets, resulting in micro targets that exhibit a volume increase compared to conventional evaporated surface targets. Furthermore, we present simulation results of the X-ray spectrum generated by these targets, demonstrating their potential to significantly improve both image quality and spatial resolution in CT applications. Our findings suggest that leveraging advanced fabrication techniques can open new avenues for the development of enhanced imaging technologies in medical diagnostics and beyond.

47 OTHER INSTRUMENTATION↗

Investigating the Impact of X-Ray Computed Tomography Imaging on Soluble Organic Matter in the Murchison Meteorite: Implications for Bennu Sample Analyses

X-ray computed tomography (XCT) is a valuable reconnaissance tool for three-dimensional imaging and identification of distinct lithologies in extraterrestrial samples. It will be used as part of the preliminary examination of samples returned from asteroid (101955) Bennu by the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission. However, it must first be established whether x-rays generated during XCT could degrade or alter the organic composition of the returned samples by radiolysis. To test this, we split a crushed sample of the Murchison CM2 meteorite, kept one portion as a control, and irradiated the other portion up to the maximum x-ray dosage (~180 Gy) that a Bennu sample would experience during an XCT imaging experiment. We then extracted organic compounds from both splits and conducted (i) nontargeted soluble organic analyses to compare the chemical distributions of C-, H-, O-, N-, and S-bearing species and (ii) targeted measurements to quantify the abundances of 96 individual soluble organic molecules that included protein amino acids, amines, carboxylic acids, hydroxy acids, carbonyl compounds, polycyclic aromatic hydrocarbons, alcohols, sugars, and N-heterocycles. We found that XCT imaging of the Murchison meteorite had no measurable impact on the relative abundances or enantiomeric compositions of most of the soluble organic compounds targeted in this study. Elevated total abundances of several soluble organic compound classes were observed in the XCT-scanned Murchison sample relative to the control. This is likely related to particle size heterogeneity and specific surface area differences between the sample aliquots used for the extractions, rather than a result of the x-ray exposure. Assuming the samples returned from asteroid Bennu by OSIRIS-REx have a similar composition to carbonaceous chondrites, these data provide confidence that XCT will not significantly alter their soluble organic compositions.

Daniel P Glavin↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Mapping Bone Mineral Density Obtained by Quantitative Computed Tomography to Bone Volume Fraction

Methods for relating or mapping estimates of volumetric Bone Mineral Density (vBMD) obtained by Quantitative Computed Tomography to Bone Volume Fraction (BVF) are outlined mathematically. The methods are based on definitions of bone properties, cited experimental studies and regression relations derived from them for trabecular bone in the proximal femur. Using an experimental range of values in the intertrochanteric region obtained from male and female human subjects, age 18 to 49, the BVF values calculated from four different methods were compared to the experimental average and numerical range. The BVF values computed from the conversion method used data from two sources. One source provided pre bed rest vBMD values in the intertrochanteric region from 24 bed rest subject who participated in a 70 day study. Another source contained preflight vBMD values from 18 astronauts who spent 4 to 6 months on the ISS. To aid the use of a mapping from BMD to BVF, the discussion includes how to formulate them for purpose of computational modeling. An application of the conversions would be used to aid in modeling of time varying changes in vBMD as it relates to changes in BVF via bone remodeling and/or modeling.

Pennline, James A.↗

A Novel Automated Method for Analyzing Cylindrical Computed Tomography Data

A novel software method is presented that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography. This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2-D sheets in the vertical direction in addition to volume rendering and normal plane views provided by traditional CT software. The method is based on interior and exterior surface edge detection and under proper conditions, is FULLY AUTOMATED and requires no input from the user except the correct voxel dimension from the CT scan. The software is available from NASA in 32- and 64-bit versions that can be applied to gigabyte-sized data sets, processing data either in random access memory or primarily on the computer hard drive. Please inquire with the presenting author if further interested. This software differentiates itself in total from other possible re-slicing software solutions due to complete automation and advanced processing and analysis capabilities.

Roth, D. J.↗

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗