Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compton Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

COMPTEL: Instrument description and performance

The imaging Compton telescope (COMPTEL) is one of the four gamma ray detectors aboard the Compton Gamma Ray Observatory (GRO). COMPTEL is sensitive to gamma rays from 800 keV to 30 MeV with a field of view of approximately 1 sr. Its angular resolution ranges between 1 and 2 degrees depending on the energy and incidence angle. The energy resolution of better than 10 percent FWHM enables COMPTEL to provide spectral resolution in the regime of astrophysical nuclear lines. The effective area varies typically from 10 to 50 cm(exp 2) depending on the energy and event selections made. In its telescope mode, COMPTEL is able to study a wide variety of objects, pointlike as well as extended in space. With 0.125 msec timing resolution, pulsed emission can be studied. In the single detector mode, COMPTEL uses two of its detectors to study the temporal spectral evolution of strong gamma ray bursts or transients.

Denherder, J. W.↗

Data analysis of the COMPTEL instrument on the NASA gamma ray observatory

The Compton imaging telescope (COMPTEL) on the Gamma Ray Observatory (GRO) is a wide field of view instrument. The coincidence measurement technique in two scintillation detector layers requires specific analysis methods. Straightforward event projection into the sky is impossible. Therefore, detector events are analyzed in a multi-dimensional dataspace using a gamma ray sky hypothesis convolved with the point spread function of the instrument in this dataspace. Background suppression and analysis techniques have important implications on the gamma ray source results for this background limited telescope. The COMPTEL collaboration applies a software system of analysis utilities, organized around a database management system. The use of this system for the assistance of guest investigators at the various collaboration sites and external sites is foreseen and allows different detail levels of cooperation with the COMPTEL institutes, dependent on the type of data to be studied.

Diehl, R.↗

Neutron induced background in the COMPTEL detector on the Gamma Ray Observatory

Interactions of neutrons in a prototype of the Compton imaging telescope (COMPTEL) gamma ray detector for the Gamma Ray Observatory were studied to determine COMPTEL's sensitivity as a neutron telescope and to estimate the gamma ray background resulting from neutron interactions. The IUCF provided a pulsed neutron beam at five different energies between 18 and 120 MeV. These measurements showed that the gamma ray background from neutron interactions is greater than previously expected. It was thought that most such events would be due to interactions in the upper detector modules of COMPTEL and could be distinguished by pulse shape discrimination. Rather, the bulk of the gamma ray background appears to be due to interactions in passive material, primarily aluminum, surrounding the D1 modules. In a considerable fraction of these interactions, two or more gamma rays are produced simultaneously, with one interacting in the D1 module and the other interacting in the module of the lower (D2) detector. If the neutron interacts near the D1 module, the D1 D2 time of flight cannot distinguish such an event from a true gamma ray event. In order to assess the significance of this background, the flux of neutrons in orbit has been estimated based on observed events with neutron pulse shape signature in D1. The strength of this neutron induced background is estimated. This is compared with the rate expected from the isotropic cosmic gamma ray flux.

Morris, D. J.↗

COMPTEL neutron response at 17 MeV

The Compton imaging telescope (COMPTEL) instrument of the Gamma Ray Observatory was exposed to 17 MeV d,t neutrons prior to launch. These data were analyzed and compared with Monte Carlo calculations using the MCNP(LANL) code. Energy and angular resolutions are compared and absolute efficiencies are calculated at 0 and 30 degrees incident angle. The COMPTEL neutron responses at 17 MeV and higher energies are needed to understand solar flare neutron data.

Oneill, Terrence J.↗

The Gamma Ray Observatory - Viewing the violent universe

An overview is given of the Gamma Ray Observatory (GRO) experimental satellite and the four instruments that permit the study of space phenomena from 0.03 to 30,000 MeV. The GRO comprises: (1) the Burst and Transient Source Experiment; (2) the Oriented Scintillation Spectrometer Experiment; (3) the Imaging Compton Telescope; and (4) the Energetic Gamma-Ray Experiment Telescope. The GRO is expected to provide data regarding the active galaxies, extragalactic diffuse radiation, the Galactic center, matter-antimatter annihilation, and gamma-ray emission from quasars.

Thompson, D. J.↗

The Crab nebula and pulsar in the MeV energy range

The imaging Compton Telescope (COMPTEL) is sensitive in the energy range of 0.75 to 30 MeV. COMPTEL observed the Crab several times during the Compton Gamma Ray Observatory (CGRO) sky survey and CGRO Phase II. Both the Crab pulsar and nebula are detected over the entire COMPTEL energy range. The phase-averaged energy spectra of the Crab Pulsar and Nebula are presented. The combined observations provide sufficient statistics for a phase-resolved analysis of the Crab pulsar spectrum.

Much, R.↗

COMPTEL upper limits on gamma-ray line emission from Supernova 1991T

The imaging Compton telescope COMPTEL on board the Compton Gamma-Ray Observatory (CGRO) measures gamma-rays in the energy range 0.75-30 MeV with an energy resolution of 9.7% full width at half maximum (FWHM) at 1 MeV. From June 15 to 28, 1991 and again from October 3 to 17, 1991 the region containing the supernova SN 1991T was observed. A search for gamma-ray line emission from the supernova yields no detection of line emission from the supernova. 2 sigma upper limits for the two predicted lines at 847 keV and at 1.238 MeV of approximately equal to 3 x 10(exp -5) photons/(sq cm)(s) were derived. These limits are compared with the predictions of some theoretical models and constraints imposed by these limits on these models are discussed.

Lichti, G. G.↗

All-Sky Medium-Energy Gamma-Ray Observatory (AMEGO)

The gamma-ray energy range from a few hundred keV (kiloelectronvolts) to a few hundred MeV (megaelectronvolts) has remained largely unexplored since the pioneering but limited observations by COMPTEL (The Imaging Compton Telescope) on the CGRO (Compton Gamma Ray Observatory) (1991-2000). Fundamental astrophysics questions can be addressed by a mission in the MeV range, from astrophysical jets and extreme physics of compact objects to a large population of unidentified objects. Such a mission will also provide critical inputs for multimessenger astrophysics by identifying and exploring the astrophysical objects that produce gravitational waves and neutrinos. To address these questions, we are developing AMEGO: All-sky Medium Energy Gamma-ray Observatory, as a NASA probe-class mission, to investigate the energy range from 200 keV to greater than10 GeV with good energy (ranging from less than 1 percent at the low end to approximately 10 percent at the high end) and angular resolution (from 2 to 6 degrees depending on energy) and with sensitivity a factor of 20-50 better than previous instruments. Measurements at these energies are challenging, mainly due to the fact that two photon interaction processes, Compton scattering and pair production, compete. These interaction processes require different approaches in both detection and data analysis, and consequently in the instrument concept. AMEGO will be capable of measuring both Compton-scattering events at lower energies and pair-production events at higher energies. AMEGO will also have sensitivity to linear polarization of detected radiation at a level of 20 percent minimum detectable polarization from a source 1 percent of the Crab intensity, observed for 106 seconds. AMEGO will be operating mainly in scanning (discovery) mode with a field-of-view of 2.5 sr (Special Relativity) (20 percent of the sky observation any time), with the capability to be pointed to particular regions of interest..

Moiseev, Alexander↗

Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Likelihood Compton Polarimetry with the Compton Spectrometer and Imager

Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an ideal Compton polarimeter can be improved by ∼21% when an unbinned, maximum likelihood method (MLM) is used instead of the standard approach of fitting a sinusoid to a histogram of azimuthal scattering angles. Here we outline a procedure for implementing this maximum likelihood approach for real, nonideal polarimeters. As an example, we use the recent observation of GRB 160530A with the Compton Spectrometer and Imager. We find that the MDP for this observation is reduced by 20% when the MLM is used instead of the standard method.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging

In this paper we present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proofof-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response and showlinear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, our preliminary measurements show energy resolutions of 40-180eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.

47 OTHER INSTRUMENTATION↗

Crystal Compton Camera

Stand-off detection is one of the most important radiation detection capabilities for arms control and the control of illicit nuclear materials. For long range passive detection one requires a large detector and a means of “seeing through” the naturally occurring and varying background radiation, i.e. imaging. Arguably, Compton imaging is the best approach over much of the emission band suitable for long range detection. It provides not only imaging, but more information about the direction of incidence of each detected gamma-ray than the alternate approach of coded-aperture imaging. The directional information allows one to reduce the background and hence improve the sensitivity of a measurement. However, to make an efficient Compton imager requires localizing and measuring the simultaneous energy depositions when gamma-rays Compton scatter and are subsequently captured within a single, large detector volume. This concept has been demonstrated in semi-conductor detectors (HPGe, CZT, Si) but at ~ $1k/cm 3 these materials are too expensive to build the large systems needed for standoff detection. Scintillator detectors, such as NaI(Tl), are two orders of magnitude less expensive and possess the energy resolution required to make such an imager. However, they do not currently have the ability to localize closely spaced, simultaneous energy depositions in a single large crystal. In this project we are applying a new technique that should, for the first time ever, allow cubic-millimeter event localization in a bulk scintillator crystal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gamma-ray momentum reconstruction from Compton electron trajectories by filtered back-projection

Gamma-ray imaging utilizing Compton scattering has traditionally relied on measuring coincident gamma-ray interactions to map directional information of the source distribution. This coincidence requirement makes it an inherently inefficient process. We present an approach to gamma-ray reconstruction from Compton scattering that requires only a single electron tracking detector, thus removing the coincidence requirement. From the Compton scattered electron momentum distribution, our algorithm analytically computes the incident photon's correlated direction and energy distributions. Because this method maps the source energy and location, it is useful in applications, where prior information about the source distribution is unknown. We demonstrate this method with electron tracks measured in a scientific Si charge coupled device. While this method was demonstrated with electron tracks in a Si-based detector, it is applicable to any detector that can measure electron direction and energy, or equivalently the electron momentum. For example, it can increase the sensitivity to obtain energy and direction in gas-based systems that suffer from limited efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗