Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Radial heterogeneity of some analytical columns used in high-performance liquid chromatography

An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm x 4.6 mm C18 bonded silica-based monolithic column, a 150 mm x 4.6 mm column packed with 2.7 {micro}m porous shell particles of C18 bonded silica (HALO), and a 150 mm x 4.6 mm column packed with 3 {micro}m fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35-50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5-4.0% lower in the wall region for the two particle-packed columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra high pressure liquid chromatography column permeability and changes of the eluent properties

The behavior of four similar liquid chromatography columns (2.1 mm i.d. x30, 50, 100, and 150 mm, all packed with fine particles, average d{sub p} {approx} 1.7 {micro}m, of bridged ethylsiloxane/silica hybrid-C{sub 18}, named BEH-C{sub 18}) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of C in still air and C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144 {+-} 3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured {Delta}T = 25-30 K, ({Delta}{eta}/{eta}) {approx_equal} 100%, and ({Delta}{rho}/{rho}) {approx_equal} 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in UPLC is discussed.

36 MATERIALS SCIENCE↗

Multi-Column Experimental Test Bed Using CaSDB MOF for Xe/Kr Separation

Processing of spent nuclear fuel produces off-gas from which several volatile radioactive components must be separated for further treatment or storage. As part of the Off-gas Sigma Team, parallel research at INL and PNNL has produced several promising sorbents for the selective capture of xenon and krypton from these off-gas streams. In order to design full-scale treatment systems, sorbents that are promising on a laboratory scale must be proven under process conditions to be considered for pilot and then full-scale use. To that end, a bench-scale multi-column system with capability to test multiple sorbents was designed and constructed at INL. This report details bench-scale testing of CaSDB MOF, produced at PNNL, and compares the results to those reported last year using INL engineered sorbents. Two multi-column tests were performed with the CaSDB MOF installed in the first column, followed with HZ-PAN installed in the second column. The CaSDB MOF column was placed in a Stirling cryocooler while the cryostat was employed for the HZ-PAN column. Test temperatures of 253 K and 191 K were selected for the first column while the second column was held at 191 K for both tests. Calibrated volume sample bombs were utilized for gas stream analyses. At the conclusion of each test, samples were collected from each column and analyzed for gas composition. While CaSDB MOF does appear to have good capacity for Xe, the short time to initial breakthrough would make design of a continuous adsorption/desorption cycle difficult, requiring either very large columns or a large number of smaller columns. Because of the tenacity with which Xe and Kr adhere to the material once adsorbed, this CaSDB MOF may be more suitable for use as a long-term storage solution. Further testing is recommended to determine if CaSDB MOF is suitable for this purpose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anion exchange and extraction chromatography tandem column isolation of zirconium-89 ( 89 Zr) from cyclotron bombarded targets using an automated fluidic platform

The long-lived positron emitter 89 Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89 Zr for clinical use are traditionally performed with a single hydroxamate resin column. In this work, we present a tandem column purification method for the preparation of high-purity 89 Zr from cyclotron bombarded Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with HDEHP. A condition of “inverted selectivity” is presented, wherein the 89 Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89 Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89 Zr product. This approach assures delivery of very high purity 89 Zr . The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7±2.3% of the 89 Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89 Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89 Zr product volume of ~0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89 Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([M B ]) that exceed those reported by the traditional single hydroxamate column method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE COLUMN SYSTEM

Models have been developed to simulate the thermal characteristics of Crystalline Silicotitanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. The SCIX design includes CST columns inserted and supported in the tank top risers for cesium removal. Temperature distributions and maximum temperatures across the column were calculated with a focus on process upset conditions. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. The current full-scale design for the CST column includes one central cooling pipe and four outer cooling tubes. Most calculations assumed that the fluid within the column was stagnant (i.e. no buoyancy-induced flow) for a conservative estimate. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed, inadvertent column drainage, and loss of active cooling in the column. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature.

42 ENGINEERING↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

Applications of a dual-column technique in actinide separations

Selective separation of an individual actinide of interest from other actinides and accompanying lanthanides is a challenging task in radiochemistry and radioanalytical chemistry. This paper illustrates a dual column technique (i.e., stacked columns of two appropriate resins) to separate an individual actinide of interest, where the selection of two resins and a common effluent running through the stacked columns are key parameters in design of an appropriate dual column. This paper describes the dual column design and practice with two examples, one for a heavy actinide 249Bk and the other for a light actinide 230U. In the former case, stacked columns of anion exchange (AX) resin and LN resin replaced the traditional CX-AHIB method used at Oak Ridge National Laboratory for 60 years. In the latter case, an elution process with an AX column followed with a stacked column of AX resin and a DGA resin was applied, instead of traditional methods, e.g., PUREX or U-TEVA methods. Application results of the dual column method to the two example actinides are displayed, while the considerations in method design and the required conditions are discussed.

Du, Miting↗

Structural radial heterogeneity of a silica-based wide-bore monolithic column

The radial distribution of the main characteristics (elution time and standard deviation) of the elution profiles of a flat injected band recorded at the exit of a monolithic column were determined. These distributions provide the radial distributions of the average mobile phase velocity, the elution time and the maximum height of the peak of an analyte, the column efficiency and the analyte concentration. The band profiles were measured at the exit of a 10-mm i.d., 100-mm long silica-based monolithic column. An on-column local electrochemical amperometric detector allowed the recording of the elution profiles at different spatial positions throughout the column cross-section. The local spatial distribution of the mobile phase velocity does not follow a piston-flow behavior but exhibits radial heterogeneity. The local efficiency near the wall is lower than that near the column center. The radial distribution of the maximum concentration of the peaks varies throughout the column exit section, partially due to the radial variations of the column efficiency. These results might explain the rather large value of the A term of the Van Deemter or the Knox equations reported previously for monolithic columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical characterization of a shock interacting with an inclined gas column

We present a statistical characterization of the interaction between a planar shock and a finite-diameter, cylindrical column of dense gas based on three-dimensional, large-eddy simulation results. In the simulation, the column of gas is initially inclined at an angle $\alpha _0$ with respect to the shock plane. Effects of the initial column angle on the mixing characteristics are examined at Mach number 2.0 for column incline angles $1^\circ$ , $5^\circ$ , $10^\circ$ and $30^\circ$ . Mean velocity profiles show that the column angle affects the gas velocity components in the vertical plane, but not in the spanwise direction. The gas undergoes higher initial upward acceleration at larger initial column incline angles. With time, the gas motion tends to become one-dimensional in the streamwise direction. Initially, velocity fluctuations are most intense within the interior of the column, but concentrate near the column leading edge over time. At high wavenumbers $\kappa$ , the turbulent kinetic energy spectra follow a power-law scaling of $\kappa ^{-1}$ . The structure functions of the mass fraction do not clearly demonstrate power-law scaling except at early times for $\alpha _0=30^\circ$ , manifesting overall trends very similar to those observed in earlier experiments. Probability distributions of the mass fraction show independence of the mean and the standard deviation of the mixed gas on $\alpha _0$ . The column angle was also found to have little effect on the mixing efficiency characterized by the molecular mixedness. Velocity components in the streamwise and transverse directions tend towards a bimodal distribution for larger $\alpha _{0}$ .

42 ENGINEERING↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-column cryogenic air separation: enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N2-enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde's single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde's single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O2. However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

Cheng, Mao↗

Automation of Column-based Radiochemical Separations: A Comparison of Fluidic, Robotic, and Hybrid Architectures

Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on setting up samples and columns in parallel, and using disposable components so that no sample contacts any surface that any other sample has contacted. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL column bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions four rows of six vials below the columns. The samples are delivered to the columns via a manual 3-port valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is simpler and faster in performing anion exchange procedures for the recovery and purification of plutonium from samples.

99 GENERAL AND MISCELLANEOUS↗

Characterizing the Thermal Column Beam in the University of Massachusetts Lowell Research Reactor

The University of Massachusetts Lowell operates a 1 MW, light water cooled and moderated Research Reactor (UMLRR) fueled by low-enriched uranium to generate neutron flux that is used at a variety of in-core and beam port facilities within the reactor to perform irradiation experiments for academic and industrial research. One of the irradiation sites is a graphite-moderated thermal column designed to deliver a collimated beam of thermal neutrons to a neutron radiography imaging system. A detailed characterization of the neutron beam is essential for the design and interpretation of experiments at the facility and for radiation safety. This work aimed to characterize the neutron flux and energy spectrum in the UMLRR thermal column beam by employing experimental and computational methods known as the foil activation and spectrum unfolding technique. A previously existing Monte Carlo N-Particle transport (MCNP) model of the UMLRR reactor core has been extended to the thermal column where the neutron flux and energy spectrum have been computed and experimentally validated. This work employed the foil activation and spectrum unfolding technique along with neutron transport computation to extend the knowledge of the neutron fluence and energy spectrum from the UMLRR core to the adjacent thermal column beam. Radiography systems are used for materials characterization, studying dynamic behavior of engineering systems, and for nuclear forensics applications. Foil activation is an experimental method where thin foils of highly pure materials are placed in the beam where interactions between the neutrons and the foil material activate radioisotopes in the foils whose activities can be measured after the irradiation. Downstream computation with MCNP and the spectrum unfolding code SAND can deconvolute the neutron fluence and energy spectrum that must have been necessary to induce the production rates of radioisotopes that were obtained through foil activation. The necessary ingredients for successful spectrum unfolding are the experimentally measured production rates and some a priori (initial guess) knowledge of the flux spectrum. The thermal column is equipped with a neutron radiography imaging system, so any experimenters who desire to use neutron radiography at UMass Lowell will benefit significantly from knowing the characteristics of the neutron beam. Comprehensive knowledge of these characteristics of the beam is essential to compare and benchmark results obtained for similar experiments at other facilities. The Integrated Nuclear Security and Safeguards Laboratory (INSSL) is pursuing the investigation of the performance of self-healing materials under stress-strain environments and the characterization of radiation detectors and special containers for storing and transporting nuclear material. This work contributes to the improvement of the current radiography system, expands the utility of the system for nuclear safeguards and security application and provides information that will enhance the general safety of the UMLRR experimental facilities. The main objective of this work has been achieved; an appropriate neutron flux spectrum for the UMLRR thermal column beam has been determined using the foil activation method followed by spectrum unfolding. There now exists an experimentally validated computational model of the neutron flux spectrum and the thermal column's neutron environment is characterized. We can conclude that the thermal column is well characterized; an appropriate neutron flux spectrum has been determined through an experimentally validated computational model. Future experimenters interested in the thermal column may now expand on the computational model or use the spectral information for their own purposes. The knowledge gained herein will be helpful for the INSSL's future work using neutron radiography to analyze the effectiveness of self-healing materials and special containers. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

THERMAL ANALYSIS FOR IN-TANK ION-EXCHANGE COLUMN PROCESS

High Level Waste (HLW) at the Savannah River Site (SRS) is stored in three forms: sludge, saltcake, and supernate. A small column ion-exchange (SCIX) process is being designed to treat dissolved saltcake waste before feeding it to the saltstone facility to be made into grout. The waste is caustic with high concentrations of various sodium salts and lower concentrations of radionuclides. Two cation exchange media being considered are a granular form of crystalline silicotitanate (CST) and a spherical form of resorcinol-formaldehyde (RF) resin. CST is an inorganic material highly selective for cesium that is not elutable. Through this process, radioactive cesium from the salt solution is absorbed into ion exchange media (either CST or RF) which is packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. If engineering designs cannot handle this thermal load, hot spots may develop locally which could degrade the performance of the ion-exchange media. Performance degradation with regard to cesium removal has been observed between 50 and 80 C for CST [1] and at 65 C for RF resin [2]. In addition, the waste supernate solution will boil around 130 C. If the columns boiled dry, the sorbent material could plug the column and lead to replacement of the entire column module. Alternatively, for organic resins such as RF there is risk of fire at elevated temperatures. The objective of the work is to compute temperature distributions across CST- and RF-packed columns immersed in waste supernate under accident scenarios involving loss of salt solution flow through the beds and, in some cases, loss of coolant system flow. For some cases, temperature distributions are determined as a function of time after the initiation of a given accident scenario and in other cases only the final steady-state temperature distributions are calculated. In general, calculations are conducted to ensure conservative and bounding results for the maximum temperatures achievable using the current baseline column design. This information will assist in SCIX design and facility maintenance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water column particulate matter: A key contributor to phosphorus regeneration in a coastal eutrophic environment, the Chesapeake Bay: Particulate phosphorus in the Chesapeake Bay

Particulate phosphorus (PP) in the water column is an essential component of phosphorus (P) cycling in aquatic ecosystems yet its composition and transformations remain largely uncharacterized. To understand the roles of suspended particulates on regeneration of inorganic P (Pi) into the water column as well as sequestration into more stable mineral precipitates, we studied seasonal variation in both organic and inorganic P speciation in suspended particles in three sites in the Chesapeake Bay using sequential P extraction, 1D (31P) and 2D (1H-31P) nuclear magnetic resonance (NMR) spectroscopies, and electron microprobe analyses (EMPA). Remineralization efficiency of particulate P average 8% and 56% in shallow and deep sites respectively, suggesting the importance of PP remineralization is in resupplying water column Pi. Strong temporal and spatial variability of organic P composition, distributions, and remineralization efficiency were observed relating to water column parameters such as temperature and redox conditions: concentration of orthophosphate monoesters and diesters, and diester-to-monoester (D/M) ratios decreased with depth. Both esters and the D/M ratios were lower in the hypoxic July and September. In contrast, pyrophosphate and orthophosphate increased with depth, and polyphosphates was high in the anoxic water column. Sequential extraction and EMPA analyses of the suspended particles suggest presence of Ca-bound phosphate in the water column. We hypothesize authigenic precipitation of carbonate fluorapatite and/or its precursor mineral(s) in Pi rich water column, supported by our thermodynamic calculations. Our results, overall, reveal the important role suspended particles play in P remineralization and P sequestration in the Chesapeake Bay water column, provide important implications on P bioavailability and P sinks in similar eutrophic coastal environments.

58 GEOSCIENCES↗

Direct Effect of Solvent Viscosity on the Physical Mass Transfer for Wavy Film Flow in a Packed Column

ABSTRACT Post-combustion carbon capture via solvent absorption in a packed column can be a promising technology for mitigating greenhouse gas emissions. The mass transfer between gas and liquid solvent phases plays a critical role in determining the packing height of the packed column. Recent experiments [1] involving physical mass transfer for aqueous amine in a packed column have distinguished the direct and indirect impacts of viscosity (µ_L) on the mass transfer coefficient ?( k?_L). The direct impact of viscosity on the mass transfer coefficient has been found to be significantly higher for a packed column ?(k?_L~µ_L^(-0.38)) than a wetted wall column (WWC) ?(k?_L~µ_L^(-0.17)). To explain the deviation from the well-controlled uniform film flow in a WWC, we propose a mechanism involving the unavoidable wavy film flow and eddy-enhanced mass transfer in a packed column. A mathematical analysis based on fundamental flow and mass transfer equations is presented to quantify this deviation. The correlation for mass transfer coefficient derived from the mathematical analysis is found to match the corresponding one derived from the experiments for a packed column. Multiphase flow simulations using the Volume of Fluid method also are conducted to verify the direct impact of viscosity on the mass transfer coefficient for both uniform and wavy film flows. The mass transfer coefficient calculated from simulations shows steeper variation with viscosity for wavy film compared to the uniform film, further confirming our proposed theory. A similar relation ?(k?_L~µ^(-0.38)) for wavy film flow in a packed column is observed for aqueous solvent from both theory, experiment, and computer simulations.

Mass transfer, viscosity, eddy diffusion↗

Mo-99 Stripping Results and Column Designs for Mini-Medical Isotope Production System (MIPS)

Results from the column tests performed by using small volumes of irradiated solutions as tracers for depleted uranium (DU) solutions containing stable molybdenum (Mo) as Na 2 MoO 4 forced us to investigate the stripping parameters needed to obtain full Mo recovery. In an effort to optimize the stripping conditions, several column runs were done by using either 1 M NaOH or NH 4 OH as the stripping agent at different velocities. Overall, we obtained very inconsistent results that suggest stripping velocity does not affect Mo recovery as much as originally believed. In addition, we generated 0.1 M HNO 3 breakthrough curves after each run to determine if the performance of the column was changing. Future experiments will utilize columns packed with fresh sorbent after each run. The column designs for the mini-MIPS 5-liter (L) and 20-L experiments employed data obtained from using several different S80 columns at different loading, washing, and stripping velocities. Data were input into the VERSE code, and plant-scale column designs were generated. The mini-MIPS column designs and parameters are a direct downscale of the plant operation, where full Mo adsorption and recovery are expected.

Youker, Amanda J.↗