Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental Evaluation of Beam to Diamond Box Column Connection with Through Plate in Moment Frames

Moment resisting frames with built up section have very enhanced features due to high bending stiffness and strength characteristics in two principal axes and access to column faces for beam to column easy connections. But due to proper transfer of beam stresses to column faces there were always some specific controvertibly issues that how to make the load transfer through and in plane manner in order to mobilize the forces in column faces. Using diamond column instead of box column provide possibility to mobilize the load transfer mechanism in column faces. This section as a column has considerable benefit such as high plastic to elastic section modulus ratio which is an effective factor for force controlled components. Typical connection has no chance to be applied with diamond column.This paper elucidates the seismic behavior of through-plates moment connections to diamond box columns for use in steel moment resisting frames. This connection has a lot of economical benefits such as no need to horizontal continuity plates and satisfying the weak beam--strong column criteria in the connection region. They might serve as panel zone plates as well. According to high shear demand in panel zone of beam to column joint one should use the doublers plates in order to decrease the shear strength demand in this sensitive part of structure but these plates have no possibility to mobilize the load transfer mechanism in column web and transfer them to column flanges. In this type of connection, column faces have effective role in order to decrease the demands on through plate and they are impressive factors for improving the performance of the connection.Experimental analysis was conducted to elucidate the seismic behavior of this connection. The results of Experimental analysis established the effectiveness of the through plate in mitigating local stress concentrations and forming the plastic hinge zone in the beam away from the beam to column interface. The moment-rotation graphs form sub-assemblage show a desirable seismic performance of this connection.

58 GEOSCIENCES↗

HEAT TRANSFER ANALYSIS FOR FIXED CST AND RF COLUMNS

In support of a small column ion exchange (SCIX) process for the Savannah River Site waste processing program, transient and steady state two-dimensional heat transfer models have been constructed for columns loaded with cesium-saturated crystalline silicotitanate (CST) or spherical Resorcinol-Formaldehyde (RF) beads and 6 molar sodium tank waste supernate. Radiolytic decay of sorbed cesium results in heat generation within the columns. The models consider conductive heat transfer only with no convective cooling and no process flow within the columns (assumed column geometry: 27.375 in ID with a 6.625 in OD center-line cooling pipe). Heat transfer at the column walls was assumed to occur by natural convection cooling with 35 C air. A number of modeling calculations were performed using this computational heat transfer approach. Minimal additional calculations were also conducted to predict temperature increases expected for salt solution processed through columns of various heights at the slowest expected operational flow rate of 5 gpm. Results for the bounding model with no process flow and no active cooling indicate that the time required to reach the boiling point of {approx}130 C for a CST-salt solution mixture containing 257 Ci/liter of Cs-137 heat source (maximum expected loading for SCIX applications) at 35 C initial temperature is about 6 days. Modeling results for a column actively cooled with external wall jackets and the internal coolant pipe (inlet coolant water temperature: 25 C) indicate that the CST column can be maintained non-boiling under these conditions indefinitely. The results also show that the maximum temperature of an RF-salt solution column containing 133 Ci/liter of Cs-137 (maximum expected loading) will never reach boiling under any conditions (maximum predicted temperature without cooling: 88 C). The results indicate that a 6-in cooling pipe at the center of the column provides the most effective cooling mechanism for reducing the maximum temperature with either ion exchange material. Sensitivity calculations for the RF resin porosity, the ambient external column temperature, and the cooling system configuration were performed under the baseline conditions to assess the impact of these parameters on the maximum temperatures. It is noted that the cooling mechanism at the column boundary (forced versus natural convection) and the cooling system configuration significantly impact the maximum temperatures. The analysis results provide quantitative information associated with process temperature control requirements and management of the SCIX column.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THERMAL MODELING OF ION EXCHANGE COLUMNS WITH SPHERICAL RF RESIN

Models have been developed to simulate the thermal performance of RF columns fully loaded with radioactive cesium. Temperature distributions and maximum temperatures across the column were calculated during Small Column Ion Exchange (SCIX) process upset conditions with a focus on implementation at Hanford. A two-dimensional computational modeling approach was taken to include conservative, bounding estimates for key parameters such that the results will provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on RF. The current full-scale design for the SCIX system includes a central cooling tube, and one objective of these calculations was to examine its elimination to simplify the design. Results confirmed that a column design without a central cooling tube is feasible for RF, allowing for the possibility of significant design simplifications if it can be assumed that the columns are always filled with liquid. With active cooling through the four outer tubes, the maximum column diameter expected to maintain the temperature below the assumed media and safety limits is 26 inches, which is comparable to the current design diameter. Additional analysis was conducted to predict the maximum column temperatures for the previously unevaluated accident scenario involving inadvertent drainage of liquid from a cesium-saturated column, with retention of the ion exchange media and cesium in the column. As expected, much higher maximum temperatures are observed in this case due to the poor heat transfer properties of air versus liquid. For this hypothetical accident scenario involving inadvertent and complete drainage of liquid from a cesium-saturated column, the modeling results indicate that the maximum temperature within a 28 inch diameter RF column with external cooling is expected to exceed 250 C within 2 days, while the maximum temperature of a 12 inch column is maintained below 100 C. In addition, the calculation results demonstrate that the cooling tube system external to an air-filled column is not highly effective at reducing the maximum temperature, but the baseline design using a central cooling tube inside the column provides sufficient cooling to maintain the maximum temperature near the assumed safety limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Parameters Impacting Columnated Granular Soil Pneumatic Seal Performance

The ability of a column of loose granular soil to form a pneumatic seal was investigated by varying the diameter of the soil column, the effective column height, and the level of compaction in the soil. The soil column diameter was tested at three levels using pipes with inner diameters measuring 5.08, 10.16, and 15.24 centimeters (2, 4, and 6 inches). Soil was filled in each pipe to form 15, 30, and 45 centimeter (6, 12, and 18 inch) tall soil columns. Each diameter/height configuration was also tested at three levels of soil compaction, compared by calculating the bulk density of the soil with mass and volume measurements. GRC-1a simulant was used, with approximate low/medium/high bulk densities of 1.6, 1.75, and 1.9 g/cc achieved with a combination of vibration and tamping. The order of tests for a given column diameter was randomized and repeated three times. With the top of the soil open to atmosphere at room temperature, compressed air was injected through a small diffuser at the column base with several small downward-facing holes. The number and size of these holes was scaled such that a constant total inlet orifice area to column cross sectional area ratio was maintained for each column diameter. Inlet air pressure was slowly increased via a precision regulator to preserve quasi-static equilibrium in the soil column to minimize the impact of dynamics. Air pressure was increased all the way through the static and bubbling regimes until slugging or turbulent behavior was observed in the soil to ensure that the entire static regime had been captured during data collection. A three-factor, three-level analysis of variance (ANOVA) statistical analysis was performed on the resulting data to determine the extent to which each physical parameter impacted the soil column seal performance. It was concluded that there is statistically significant evidence that column height, and the interaction between column height and diameter impact soil seal performance. In all other cases there was insufficient data to identify a statistically significant causal relationship. Additionally, plots were generated comparing experimental data to the predictive formula developed by Ogino et al. for fluidized beds in 1993. Because this model was developed for industrial spouted fluidized beds, the accuracy of its output prior to fluidization in the static seal ‘edge case’ is unknown, especially considering in this application the working gas was diffused across the column base rather than being injected through a spout. Further, the fidelity of the model had not yet been tested with lunar soil simulants. Plotting the Ogino et al. model alongside test data allows for a more intuitive sense of the impact of test parameters on soil seal performance, as well as providing a quick means to further tune this predictive model for more accurate use with static seals across granular lunar soil simulants. The model provided by Ogino et al. was further tuned using test data to determine the degree to which a spouted bed model could be applied to a slightly modified set of testing conditions: lunar soil simulants and a more diffuse, homogeneous application of pneumatic pressure. A Matlab script was created to test different values for the leading coefficient and exponents in Ogino’s formula. The script swept preset ranges, then iterated with higher resolutions across narrower ranges to converge on the optimal value for each parameter. The resulting adjusted model was compared to the original, as well as test data with noticeable improvements across the entire test domain.

Jack Stewart↗

Biogeochemistry of Two Types of Permeable Reafctive Barriers, Organic Carbon and Iron-bearing Organic Carbon for Mine Drainage treatment: Column experiments

Permeable reactive barriers (PRBs) are an alternative technology to treat mine drainage containing sulfate and heavy metals. Two column experiments were conducted to assess the suitability of an organic carbon (OC) based reactive mixture and an Fe{sup 0}-bearing organic carbon (FeOC) based reactive mixture, under controlled groundwater flow conditions. The organic carbon mixture contains about 30% (volume) organic carbon (composted leaf mulch) and 70% (volume) sand and gravel. The Fe{sup 0}-bearing organic carbon mixture contains 10% (volume) zero-valent iron, 20% (volume) organic carbon, 10% (volume) limestone, and 60% (volume) sand and gravel. Simulated groundwater containing 380 ppm sulfate, 5 ppm As, and 0.5 ppm Sb was passed through the columns at flow rates of 64 (the OC column) and 62 (the FeOC column) ml d{sup -1}, which are equivalent to 0.79 (the OC column) and 0.78 (the FeOC column) pore volumes (PVs) per week or 0.046 m d{sup -1} for both columns. The OC column showed an initial sulfate reduction rate of 0.4 {mu}mol g (OC){sup -1} d{sup -1} and exhausted its capacity to promote sulfate reduction after 30 PVs, or 9 months of flow. The FeOC column sustained a relatively constant sulfate reduction rate of 0.9 {mu}mol g (OC){sup -1} d{sup -1} for at least 65 PVs (17 months). In the FeOC column, the {delta}34S values increase with the decreasing sulfate concentration. The {delta}34S fractionation follows a Rayleigh fractionation model with an enrichment factor of 21.6%. The performance decline of the OC column was caused by the depletion of substrate or electron donor. The cathodic production of H{sub 2} by anaerobic corrosion of Fe probably sustained a higher level of SRB activity in the FeOC column. These results suggest that zero-valent iron can be used to provide an electron donor in sulfate reducing PRBs. A sharp increase in the {delta}13C value of the dissolved inorganic carbon and a decrease in the concentration of HCO{sub 3}{sup -} indicate that hydrogenotrophic methanogenesis is occurring in the first 15 cm of the FeOC column.

36 MATERIALS SCIENCE↗

3D Simulations of Irradiated One-Sided Dual-Column 3D Silicon Detector

We undertook, at Brookhaven National Laboratory (BNL), full 3D simulations of one-sided dual-type column 3D Si detectors (p-type substrate) after irradiation levels up to 1 x 10{sup 16} n{sub eq}/cm{sup 2}. Etching does not extend all the way through the substrate, so that all electrodes are on the front side; the backside was neither supported nor processed, covered only with a layer of silicon dioxide. Hence, BNL's one-sided dual-type column 3D detectors are true one-sided detectors. Our simulations of the electric fields at various fluences will add to our knowledge about the practicable applicability of these detectors in the high-radiation environment of future colliders. Simulations show that the full depletion voltage, V{sub fd}, for a dual-column 3D detector is about 1.4 times higher than that of a 2D (planar) pad detector with a thickness d, the same as the column spacing, L{sub p}, in the 3D detector. Moreover, the highest E-field is near the n{sup +} column, while the high E-field mainly is distributed between the n{sup +} and p{sup +} columns. The low E-field is between the two p{sup +} columns, with its lowest point in the center of the unit cell with two p{sup +} columns and two n{sup +} columns. To fully deplete a dual-column 3D detector at 1 x 10{sup 16} n{sub eq}/cm{sup 2} with a reasonable bias ({le} 200 V) necessitates reducing the column spacing, L{sub p}, to 30 {mu}m. The volume under the columns (10% of the total volume) can be depleted with a modest bias ({le}200 V); this underlying volume is not a dead volume. In addition, this depletion volume can support detection sensitivity directly under the columns, thereby lowering the effective dead volume in a 3D Si detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Column Experimental Test Bed for Xe/Kr Separation

Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both tests. The effluent from the AgZ-PAN column was monitored via GC-TCD during the tests with no xenon being observed exiting the column during either test. Samples from each column were taken via evacuated sample bombs and were analyzed by GC-MS analysis. The results demonstrated the ability to separate xenon from krypton from a mixed gas feed utilizing the new multi-column system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

Influence of viscous friction heating on the efficiency of columns operated under very high pressures

When columns packed with very fine particles are operated at high mobile phase velocities, the friction of the mobile phase percolating through the column bed generates heat. This heat dissipates along and across the column and axial and radial temperature gradients appear. The wall region of the column tends to be cooler than its center, and due to the influence of temperature on the mobile phase viscosity and on the equilibrium constant of analytes, the band velocity is not constant across the column. This radial heterogeneity of the temperature distribution across the column contributes to band broadening. This phenomenon was investigated assuming a cylindrically symmetrical column and using the general dispersion theory of Aris, which relates the height equivalent to the theoretical plate (HETP) contribution due to a radial heterogeneity of the column to the radial distribution of the linear velocities of a compound peak and to the radial distribution of its apparent dispersion coefficients in the column bed. The former is known from the temperature gradient across the column, the temperature dependencies of the mobile phase viscosity, and the retention factor of the compound. The latter is derived from the known expression of the transverse reduced HETP equation for the column. The values of the HETP calculated with the Aris model and a classical HETP equation were compared to those measured on a 2.1 x 50 mm Acquity BEH-C{sub 18} column, run at flow rates of 0.6, 0.95, 1.30, and 1.65 mL/min, with pure acetonitrile as the mobile phase and naphtho[2,3-a]pyrene as the retained compound. These two sets of data are in generally good agreement, although the experimental values of the HETP tend to increase faster with increasing mobile phase velocity than the calculated values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cesium Ion Exchange Testing Using a Three-Column System with Crystalline Silicotitanate and Hanford Tank Waste 241-AP-107

Washington River Protection Solutions (WRPS) is working to support early production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which in effect filters tank waste supernate and processes it through a cesium ion exchange medium to remove 137Cs. The 137Cs-depleted product is sent to the WTP for vitrification. Rovira et al. (2018) reported the successful Cs removal from Hanford tank 241-AP-107 waste (hereafter called AP-107) using crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B, Batch 2081000057) in a lead-lag column system. Since that testing, WRPS has changed the column design to a three-column system. WRPS requested a repeated study with AP-107 tank waste using a different batch of IONSIVTM R9140-B, Lot 2002009604, in a three-column format. A small-scale test platform was constructed to demonstrate solids filtration, Cs removal, and LAW vitrification and installed at Pacific Northwest National Laboratory. This report describes the small-scale ion exchange testing system component of the test platform and the processing of approximately 8.55 L of filtered AP-107 supernate using CST, Lot 8056262-999, that passed through a 25-mesh filter. This report also describes the Cs ion exchange batch contact testing to determine the Cs distribution coefficient and the maximum Cs loading capacity in the AP-107 tank waste matrix. Batch contact testing helps to evaluate CST performance on tank waste supernate and is often used prior to processing tank waste through ion exchange columns to assess some performance metrics (e.g., 50% Cs breakthrough). Batch contact tests were performed with the filtered AP-107 tank waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass). The distribution coefficient (K d ) at the equilibrium condition of 9.2 µg Cs/mL (AP-107 feed condition) was determined to be 806 mL AP 107/g CST. With a CST bed density of 1.01 g/mL (<25 mesh CST), this K d corresponded to a predicted 50% Cs breakthrough of 814 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 8.3 mg Cs/g dry CST. The three-column format testing was prototypic to the intended TSCR operations, albeit on a small scale with 10-mL CST beds. Flowrate was adjusted to match the CST contact time expected for the full-scale operation, i.e., matched bed volumes per hour (BV/h) flow rate. The feed was processed downflow through the lead column, then through the middle column, and then through the polish column. Loading continued at an average of 1.88 BV/h (1.83 to 2.04 BV/h range) until the entire available AP-107 feed was processed. The Cs-decontaminated product will be provided for vitrification testing. The lead column only reached 45% Cs breakthrough after processing 855 BVs of feed. The 50% Cs breakthrough was extrapolated to occur at ~900 BVs. This extrapolated 50% Cs breakthrough value differed from the batch contact estimate (814 BVs) by 13%. The waste acceptance criteria (WAC) or contract limit for the WTP LAW vitrification facility is 3.18E-5 Ci 137 Cs per mole Na. For the AP-107 tank waste, only 0.127% of the influent 137 Cs concentration may be delivered to the WTP; this required a Cs decontamination factor of 787. The Cs effluent from the middle column reached the WAC after processing 590 BVs. Cs breakthrough from the polish column began at 590 BVs, reaching 6.3E-3 µCi/mL or 4.3E-3% Cs breakthrough after processing 844 BVs of feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radial heterogeneity of some analytical columns used in high-performance liquid chromatography

An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm x 4.6 mm C18 bonded silica-based monolithic column, a 150 mm x 4.6 mm column packed with 2.7 {micro}m porous shell particles of C18 bonded silica (HALO), and a 150 mm x 4.6 mm column packed with 3 {micro}m fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35-50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5-4.0% lower in the wall region for the two particle-packed columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra high pressure liquid chromatography column permeability and changes of the eluent properties

The behavior of four similar liquid chromatography columns (2.1 mm i.d. x30, 50, 100, and 150 mm, all packed with fine particles, average d{sub p} {approx} 1.7 {micro}m, of bridged ethylsiloxane/silica hybrid-C{sub 18}, named BEH-C{sub 18}) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of C in still air and C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144 {+-} 3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured {Delta}T = 25-30 K, ({Delta}{eta}/{eta}) {approx_equal} 100%, and ({Delta}{rho}/{rho}) {approx_equal} 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in UPLC is discussed.

36 MATERIALS SCIENCE↗

Multi-Column Experimental Test Bed Using CaSDB MOF for Xe/Kr Separation

Processing of spent nuclear fuel produces off-gas from which several volatile radioactive components must be separated for further treatment or storage. As part of the Off-gas Sigma Team, parallel research at INL and PNNL has produced several promising sorbents for the selective capture of xenon and krypton from these off-gas streams. In order to design full-scale treatment systems, sorbents that are promising on a laboratory scale must be proven under process conditions to be considered for pilot and then full-scale use. To that end, a bench-scale multi-column system with capability to test multiple sorbents was designed and constructed at INL. This report details bench-scale testing of CaSDB MOF, produced at PNNL, and compares the results to those reported last year using INL engineered sorbents. Two multi-column tests were performed with the CaSDB MOF installed in the first column, followed with HZ-PAN installed in the second column. The CaSDB MOF column was placed in a Stirling cryocooler while the cryostat was employed for the HZ-PAN column. Test temperatures of 253 K and 191 K were selected for the first column while the second column was held at 191 K for both tests. Calibrated volume sample bombs were utilized for gas stream analyses. At the conclusion of each test, samples were collected from each column and analyzed for gas composition. While CaSDB MOF does appear to have good capacity for Xe, the short time to initial breakthrough would make design of a continuous adsorption/desorption cycle difficult, requiring either very large columns or a large number of smaller columns. Because of the tenacity with which Xe and Kr adhere to the material once adsorbed, this CaSDB MOF may be more suitable for use as a long-term storage solution. Further testing is recommended to determine if CaSDB MOF is suitable for this purpose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anion exchange and extraction chromatography tandem column isolation of zirconium-89 ( 89 Zr) from cyclotron bombarded targets using an automated fluidic platform

The long-lived positron emitter 89 Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89 Zr for clinical use are traditionally performed with a single hydroxamate resin column. In this work, we present a tandem column purification method for the preparation of high-purity 89 Zr from cyclotron bombarded Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with HDEHP. A condition of “inverted selectivity” is presented, wherein the 89 Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89 Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89 Zr product. This approach assures delivery of very high purity 89 Zr . The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7±2.3% of the 89 Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89 Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89 Zr product volume of ~0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89 Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([M B ]) that exceed those reported by the traditional single hydroxamate column method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE COLUMN SYSTEM

Models have been developed to simulate the thermal characteristics of Crystalline Silicotitanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. The SCIX design includes CST columns inserted and supported in the tank top risers for cesium removal. Temperature distributions and maximum temperatures across the column were calculated with a focus on process upset conditions. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. The current full-scale design for the CST column includes one central cooling pipe and four outer cooling tubes. Most calculations assumed that the fluid within the column was stagnant (i.e. no buoyancy-induced flow) for a conservative estimate. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed, inadvertent column drainage, and loss of active cooling in the column. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature.

42 ENGINEERING↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗