Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coaxial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

First Results from a Broadband Search for Dark Photon Dark Matter in the 44 to 52 μ eV Range with a Coaxial Dish Antenna

We present first results from a dark photon dark matter search in the mass range from 44 to 52 μ eV (10.7–12.5 GHz) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area 0.5 m 2 and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon photon mixing parameters χ ≳ 10 − 12 in this range at 90% confidence level. This surpasses existing constraints by about 2 orders of magnitude and is the most stringent bound on dark photons in this range below 49 μ eV . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Prediction Method for Catchment Efficiency Loss due to Coaxial Nozzle Wear in Powder Fed Directed Energy Deposition Systems

Abstract Powder fed laser directed energy deposition systems show significant promise and their widespread adoption could greatly advance manufacturing technology; however, a significant amount of gas atomized metal powder is wasted during material deposition. As contaminated powder must be collected and disposed of as hazardous waste, this process is often criticized for its low catchment efficiency. This presents potential implementation and scaling issues, as widespread use of this technology would directly increase the amount of contaminated powder in need of safe disposal. A direct contribution to this waste issue was identified in past work as wearing exterior and interior surfaces on a replaceable nozzle component within the additive head of such a system integrated into a hybrid manufacturing machine tool. A computational fluid dynamics simulation is developed specifically for use within the manufacturing process by predicting catchment efficiency losses before a deposition operation is performed. The model is robust enough to calculate a catchment efficiency estimate within a reasonable transition time before deposition and is designed to replace visual estimation of nozzle deterioration by the machine operator. Both of two previously identified wear modes are represented in the simulation. Their effects on powder stream geometry are discussed in detail and the results are compared with in-situ measurements of powder stream geometry and concentrations. The resulting work contributes to the growing understanding of using prediction and prevention methods on catchment efficiency related part defects within these systems.

DeWitte, Lisa↗

Characterizing Microwave Losses in Superconducting Coaxial Cables for Quantum Systems

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present a detailed characterization of microwave losses in commercially available superconducting cables and discuss how material characterization techniques can be useful for understanding their microscopic origin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coaxial microneedle assemblies and methods thereof

The present invention is directed to devices including one or more hollow needles and a transducing wire disposed within at least one needle. In particular instances, arrays of such needles can be employed. Methods for fabricating and using such devices are also disclosed herein.

Miller, Philip Rocco↗

Out of the Lab: 3D Printing on Non-Ideal Surfaces

In this work, coaxial direct ink writing is utilized to print sensitive or encapsulated materials onto heterogeneous and rough substrates. By enclosing the core fluid within a rigid ceramic shell, continuity is maintained even when printing on substrates traditionally considered challenging. This work presents the development of a coaxial ceramic direct ink writing system and investigates co-flow dynamics through microfluidic principles. A specially designed coaxial nozzle enables the co-extrusion of an alumina shell, with indium-tin-oxide inks serving as the core material. This approach allows the fabrication of core-shell ceramic structures suitable for future high-temperature applications on rough surfaces. The colloidal inks are tailored to achieve the necessary rheological properties and sintering performance. Additionally, flow simulations, guided by microfluidic co-flow principles, are employed to define the processing parameters for coaxial printing, ensuring precise control over the core-shell architectures. Physical modeling is further applied to study core deformation and eccentricity. These simulations are experimentally validated, supporting the successful deposition of coaxial ceramic features on heterogeneous, high-temperature ceramic substrates.

20 FOSSIL-FUELED POWER PLANTS↗

Design considerations for optimizing the transient CHI injector on QUEST

Transient coaxial helicity injection (transient CHI) on the QUEST (Q-shu University Experiment with Steady-State ST) spherical tokamak (ST) has recently validated the floating biased electrode configuration for solenoid-free plasma startup. In support of a significant divertor upgrade on QUEST, the details of the transient CHI injector geometry on QUEST have been examined more closely using tokamak simulation code (TSC) simulations. QUEST uses a HIT-II-like (Helicity Injected Torus) injector configuration in which the injector region is comprised of coaxial injector electrodes located in the lower part of the machine. TSC simulations indicate high injector flux operation may benefit from an increased gap between the coaxial electrodes. This is the first study to examine the differences between an open and closed electrode configuration for solenoid-free plasma startup using transient CHI. Results show that both configurations can generate similar levels of closed flux, but the closed configuration may be easier to implement in some ST designs as a much smaller portion of the injector needs to be close to the injector flux coil. Results show that increasing the electrode gap width from the present 10.8 cm to about 15–20 cm would increase the closed flux fraction by about 40%. The results presented in this paper are generally applicable to the CHI design for other STs.

coaxial helicity injection↗