Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circulator pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improving Characterization of Miscellaneous Energy Loads in Energy Demand Models

Miscellaneous energy loads (MELs) comprise a significant and growing portion of total building energy consumption. However relatively little is known about the products that make up MELs end uses, and MELs are modeled with less granularity than major end uses in energy demand models such as the U.S. Department of Energy's Scout energy efficiency impact analysis tool or the U.S. Energy Information Administration's National Energy Modeling System (NEMS). This paper identifies differences in the way MELs versus major building end uses are modeled, and then reviews potential sources of MELs baseline technology data that could be used to improve their characterization in energy demand models. Case studies of dry distribution transformers, hot water circulation pumps, and Japanese-style automatic bidets are presented to compare and contrast the level of baseline data available for different end uses. We show that there is potential to use data from energy conservation standards and other sources to significantly improve representation of some MELs in energy demand models, while other emerging MELs require further data collection before they can be modeled precisely.

Fares, Robert↗

Absorption heat pump for space applications

In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

Nguyen, Tuan↗

Design, manufacture, and test of coolant pump-motor assembly for Brayton power conversion system

The design, development, fabrication, and testing of seven coolant circulating pump-motor assemblies are discussed. The pump-motor assembly is driven by the nominal 44.4-volt, 400-Hz, 3-phase output of a nominal 56-volt dc input inverter. The pump-motor assembly will be used to circulate Dow Corning 200 liquid coolant for use in a Brayton cycle space power system. The pump-motor assembly develops a nominal head of 70 psi at 3.7 gpm with an over-all efficiency of 26 percent. The design description, drawings, photographs, reliability results, and developmental and acceptance test results are included.

Gabacz, L. E.↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Preliminary design of a Primary Loop Pump Assembly (PLPA), using electromagnetic pumps

A preliminary design study of flight-type dc conduction-permanent magnetic, ac helical induction, and ac linear induction pumps for circulating 883 K (1130 F) NaK at 9.1 kg/sec (20 lb/sec) is described. Various electromagnetic pump geometrics are evaluated against hydraulic performance, and the effects of multiple windings and numbers of pumps per assembly on overall reliability were determined. The methods used in the electrical-hydraulic, stress, and thermal analysis are discussed, and the high temperature electrical materials selected for the application are listed.

Moss, T. A.↗

Diaphragm Pump With Resonant Piezoelectric Drive

A diaphragm pump driven by a piezoelectric actuator is undergoing development. This pump is intended to be a prototype of lightweight, highly reliable pumps for circulating cooling liquids in protective garments and high-power electronic circuits, and perhaps for some medical applications. The pump would be highly reliable because it would contain no sliding seals or bearings that could wear, the only parts subject to wear would be two check valves, and the diaphragm and other flexing parts could be designed, by use of proven methods, for extremely long life. Because the pump would be capable of a large volumetric flow rate and would have only a small dead volume, its operation would not be disrupted by ingestion of gas, and it could be started reliably under all conditions. The prior art includes a number piezoelectrically actuated diaphragm pumps. Because of the smallness of the motions of piezoelectric actuators (typical maximum strains only about 0.001), the volumetric flow rates of those pumps are much too small for typical cooling applications. In the pump now undergoing development, mechanical resonance would be utilized to amplify the motion generated by the piezoelectric actuator and thereby multiply the volumetric flow rate. The prime mover in this pump would be a stack of piezoelectric ceramic actuators, one end of which would be connected to a spring that would be part of a spring-and-mass resonator structure. The mass part of the resonator structure would include the pump diaphragm (see Figure 1). Contraction of the spring would draw the diaphragm to the left, causing the volume of the fluid chamber to increase and thereby causing fluid to flow into the chamber. Subsequent expansion of the spring would push the diaphragm to the right, causing the volume of the fluid chamber to decrease, and thereby expelling fluid from the chamber. The fluid would enter and leave the chamber through check valves. The piezoelectric stack would be driven electrically to make it oscillate at the resonance frequency of the spring and- mass structure. This frequency could be made high enough (of the order of 400 Hz) that the masses of all components could be made conveniently small. The resonance would amplify the relatively small motion of the piezoelectric stack (a stroke of the order of 10 m) to a diaphragm stroke of the order of 0.5 mm. The exact amplification factor would depend on the rate of damping of oscillations; this, in turn, would depend on details of design and operation, including (but not limited to) the desired pressure rise and volumetric flow rate. In order to obtain resonance with large displacement, the damping rate must be low enough that the energy imparted to the pumped fluid on each stroke is much less than the kinetic and potential energy exchanged between the mass and spring during each cycle of oscillation. To minimize the power demand of the pump, a highly efficient drive circuit would be used to excite the piezoelectric stack. This circuit (see Figure 2) would amount to a special-purpose regenerative, switching power supply that would operate in a power-source mode during the part of an oscillation cycle when the excitation waveform was positive and in a power-recovery mode during the part of the cycle when the excitation waveform was negative. The circuit would include a voltage-boosting dc-to-dc converter that would convert between a supply potential of 24 Vdc and the high voltage needed to drive the piezoelectric stack. Because of the power-recovery feature, the circuit would consume little power. It should be possible to build the circuit as a compact unit, using readily available components.

Izenson, Michael G.↗

Compact, Lightweight Electromagnetic Pump for Liquid Metal

A proposed direct-current electromagnetic pump for circulating a molten alkali metal alloy would be smaller and lighter and would demand less input power, relative to currently available pumps of this type. (Molten alkali metals are used as heat-transfer fluids in high-temperature stages of some nuclear reactors.) The principle of operation of this or any such pump involves exploitation of the electrical conductivity of the molten metal: An electric current is made to pass through the liquid metal along an axis perpendicular to the longitudinal axis of the flow channel, and a magnetic field perpendicular to both the longitudinal axis and the electric current is superimposed on the flowchannel region containing the electric current. The interaction between the electric current and the magnetic field produces the pumping force along the longitudinal axis. The advantages of the proposed pump over other such pumps would accrue from design features that address overlapping thermal and magnetic issues.

Godfroy, Thomas↗

A Selected Operational History of the Internal Thermal Control System (ITCS) for International Space Station (ISS)

The Internal Thermal Control System (ITCS) has been developed jointly by Boeing Corporation, Huntsville, Alabama and Honeywell Engines & Systems, Torrance, California to meet the internal thermal control needs for the International Space Station (ISS). The ITCS provides heat removal for the critical life support systems and thermal conditioning for numerous experiment racks. The ITCS will be fitted on a number of modules on the ISS. The first US Element containing the ITCS, Node 1, was launched in December 1998. Since Node 1 does not contain a pump to circulate the fluid it was not filled with ITCS fluid until after the US Laboratory Module was installed. The second US Element module, US Laboratory Module, which contains the pumps and all the major ITCS control hardware, was launched in February 2001. The third US Element containing the ITCS, the US Airlock, was launched in July 2001. The dual loop system of the ITCS is comprised of a lowtemperature loop (LTL) and a moderate-temperature loop (MTL). Each loop has a pump package assembly (PPA), a system flow control assembly (SFCA), a threeway mixing valve (TWMV), several rack flow control assemblies (RFCA), cold plates, pressure sensors, temperature sensors, pump bypass assembly (PBA) and a heat exchanger. In addition, the MTL has an additional TWMV, a payload regeneration heat exchanger (P/RHE) and a manual flow control valve (MFCV). The LTL has a service performance and checkout unit (SPCU) heat exchanger. The two loops are linked via one loop crossover assembly (LCA) providing cross loop capabilities and a single PPA, two-loop functionality. One important parameter monitored by the ground stations and on-orbit is the amount of fluid leakage from the ITCS. ISS fluid leakage is of importance since ITCS fluid is costly to re-supply, may be difficult to clean up in zero-g, and if uncontained could lead to equipment failures and potential hazards. This paper examines the nominal leakage observed over period of a year of on-orbit operation and compares this with analysis predictions. This paper also addresses the off-nominal leakage and a fluid transfer event causing significant changes in accumulator quantity.

Patel, Vipul P.↗

Design Improvements in Liquid Argon Purification Techniques in DUNE Cold Electronics Test Cryostat (Iceberg)

A proposed design improvement for the removal of electronegative impurities from liquid argon for the purpose of neutrino detector research is described. The design will utilize a commercially available submersible pump to circulate liquid argon through an external filter containing molecular sieve and activated copper media, removing water and oxygen, respectively. The existing state-of-the-art filter design provides a throughput of 0.5 L/min, while the capacity of the submersible pump design is at least 4 L/min, though could be even higher depending on total losses within the filtration piping assembly. An additional benefit of the new design will be the ability to regenerate the filter media in situ without stopping the experimental testing. The following work will describe the design, operation, and expected performance using CFD analysis.

Schwartz, F.↗

Miniature DC electromagnetic pumps of molten lead and sodium to support development of Gen-IV nuclear reactors

This work developed designs of submerged, dual-regions, miniature DC-EM pumps for circulating molten lead and liquid sodium at ≤500 °C without active cooling for use in ex-pile and in-pile test loops to support of materials and fuel developments for Gen-IV sodium and molten lead fast nuclear reactor. These pumps with two pumping regions are 57 mm, 66.8 mm, 95.4 mm, and 133.5 mm in diameter and have two Alnico 5 permanent magnets with Hiperco-50 pole pieces for focusing the magnetic field lines in the flow duct. The Equivalent Circuit Model (ECM) linked to the Finite Element Method Magnetics (FEMM) software in MATLAB platform calculated the pumps characteristics for a wide range of parameters. Also determined are the pumps dimensions for the highest cumulative pumping power and peak efficiency. These dimensions are the height, width, and length of the flow duct, the thickness of the Alnico magnets, the length of current electrodes, and the separation distance between the two pumping regions. For molten lead, the pumping power increases from 368 W to 728 W, and the peak efficiency from 14.7% to 31.6% with increased pump diameter from 57 mm to 133.5 mm. In conclusion, for liquid sodium, both the pumping power and peak efficiency are higher, increasing from 392 W to 767 W and from 44.3 to 51.2%, respectively, with increased pump diameter from 57 mm to 133.5 mm.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Case Study for the ARRA-funded GSHP Demonstration at Furman University

With funding provided by the American Recovery and Reinvestment Act, 26 ground source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects was proposed by Furman University for ten student housing buildings—the North Village located on the campus in Greeneville, South Carolina. All ten buildings are identical in floor plan and construction. Each building is conditioned by an identical GSHP system consisting of 25 water-to-air heat pump (WAHP) units, a closed-loop vertical ground heat exchanger (GHX) installed under an adjacent parking lot, and two redundant 7.5 hp variable-speed pumps to circulate water through the GHX and the WAHPs. The actual performance of the GSHP systems is analyzed with available measured data for 2014. The annual energy performance is compared with a baseline scenario in which the building is conditioned by air-source heat pumps (ASHPs) with the minimum allowed efficiencies specified in ASHRAE Standard 90.1-2013 (SEER 13 for cooling and 7.8 HSPF for heating) and supplemental electric heaters. The comparison is made in terms of energy savings, operating cost savings, cost-effectiveness, and environmental benefits. Finally, limitations in conducting this analysis are identified and recommendations for further improving the operational efficiency of the GSHP systems are made.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Pump Assembly - An Active Cooling System for Mars Pathfinder Thermal Control

The Mars Pathfinder spacecraft which will be launched in December 1996 features an active cooling system for controlling the temperature of the spacecraft. This will be the first time that such a mechanical pump cooling system is used on an interplanetary or long duration flight (over two weeks) in space. The major element of the cooling system is the Integrated Pump Assembly (IPA). It uses centrifugal pumps to circulate liquid Freon to transfer heat from spacecraft electronics to an external radiator. This paper describes the design, fabrication, assembly, and testing of the IPA.

cooling↗

Scalable Technologies Achieving Risk-Informed Condition-Based Predictive Maintenance Enhancing the Economic Performance of Operating Nuclear Power Plants

The primary objective of the research presented in this report is to develop scalable technologies that are deployable across plant assets and across the nuclear fleet to achieve risk-informed predictive maintenance (PdM) strategies at commercial nuclear power plants (NPPs). Over the years, the nuclear fleet has relied on labor-intensive and time-consuming preventive maintenance (PM) programs, driving up operation and maintenance (O&M) costs to achieve high capacity factors. A well-constructed risk-informed PdM approach for an identified plant asset has been developed in this research, taking advantage of advancements in data analytics, machine learning (ML), artificial intelligence (AI), physics-informed modeling, and visualization. These technologies would allow commercial NPPs to reliably transition from current labor-intensive PM programs to a technology driven PdM program, eliminating unnecessary O&M costs. The work presented in the report is being developed as part of a collaborative research effort between Idaho National Laboratory and Public Service Enterprise Group Nuclear, LLC. This report (1) reflects the results of work by LWRS Program researchers with PSEG, Nuclear LLC-owned Salem and Hope Creek Nuclear Power Plants; (2) presents utilization of circulating water system (CWS) heterogeneous data and fault modes from both the Salem and Hope Creek nuclear power plant sites to develop salient fault signatures associated with each fault mode; (3) describes the integration of component-level predictive models into a robust system-level model enabled by the federated-transfer learning; (4) describes the development of physics-informed model of circulating water pump and motor; (5) develops a scalable risk and economic model; and (6) outlines the development of a user-centric visualization application. The outcomes presented in this report lays the foundation and provides a much-needed technical basis to focus on explainability and trustworthiness of ML and AI-based technologies, as part of future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEMONSTRATION OF A PASSIVE CONDENSER LOOP

Building HVAC consumes significant amount of energy. It is estimated that about 7% of the total electricity consumed by water cooled chiller is used to drive the condenser water pump. A passive condenser loop is developed to curb this energy consumption by replacing the open pumped loop to a closed loop thermosyphon system. The loop thermosyphon uses waste heat to circulate the condenser fluid, eliminating the electrical pumping power requirement and the large circulation pump. Since it is a closed loop, it also reduces the maintenance cost and enables both wet and dry cooling modes. A demonstration unit with a riser about 40 feet (12.2 meters) tall is fabricated and tested at powers up to 25 kW. The result has successfully showed that the loop thermosyphon is able to transfer the heat near isothermally (∆T < 0.4C) over the long distance without the need of any pump and consuming any electricity.

Loop thermosyphon, building HVAC, condenser loop↗

An Experimental Test Facility to Support Development of the Fluoride Salt Cooled High Temperature Reactor

The need for high-temperature (greater than 600 C) energy exchange and delivery systems is significantly increasing as the world strives to improve energy efficiency and develop alternatives to petroleum-based fuels. Liquid fluoride salts are one of the few energy transport fluids that have the capability of operating at high temperatures in combination with low system pressures. The Fluoride Salt-Cooled High-Temperature Reactor design uses fluoride salt to remove core heat and interface with a power conversion system. Although a significant amount of experimentation has been performed with these salts, specific aspects of this reactor concept will require experimental confirmation during the development process. The experimental facility described here has been constructed to support the development of the Fluoride Salt Cooled High Temperature Reactor concept. The facility is capable of operating at up to 700 C and incorporates a centrifugal pump to circulate FLiNaK salt through a removable test section. A unique inductive heating technique is used to apply heat to the test section, allowing heat transfer testing to be performed. An air-cooled heat exchanger removes added heat. Supporting loop infrastructure includes a pressure control system; trace heating system; and a complement of instrumentation to measure salt flow, temperatures, and pressures around the loop. The initial experiment is aimed at measuring fluoride salt heat transfer inside a heated pebble bed similar to that used for the core of the pebble bed advanced high-temperature reactor. This document describes the details of the loop design, auxiliary systems used to support the facility, the inductive heating system, and facility capabilities.

fluoride salt reactor FLiNaK↗

Mixing Study for JT-71/72 Tanks

All modeling calculations for the mixing operations of miscible fluids contained in HB-Line tanks, JT-71/72, were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed by using the validated model to quantify the mixing time for the HB-Line tanks. The mixing study results for the JT-71/72 tanks show that, for the cases modeled, the mixing time required for blending of the tank contents is no more than 35 minutes, which is well below 2.5 hours of recirculation pump operation. Therefore, the results demonstrate the adequacy of 2.5 hours’ mixing time of the tank contents by one recirculation pump to get well mixed.

42 ENGINEERING↗

HYDRAULICS AND MIXING EVALUATIONS FOR NT-21/41 TANKS

The hydraulic results demonstrate that pump head pressure of 20 psi recirculates about 5.6 liters/min flowrate through the existing 0.131-inch orifice when a valve connected to NT-41 is closed. In case of the valve open to NT-41, the solution flowrates to HB-Line tanks, NT-21 and NT-41, are found to be about 0.5 lpm and 5.2 lpm, respectively. The modeling calculations for the mixing operations of miscible fluids contained in the HB-Line tank NT-21 were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed for the nominal case by using the validated model to quantify the mixing time for the HB-Line tank. The results demonstrate that when a pump recirculates a solution volume of 5.7 liters every minute out of the 72-liter tank contents containing two acid solutions of 2.7 M and 0 M concentrations (i.e., water), a minimum mixing time of 1.5 hours is adequate for the tank contents to get the tank contents adequately mixed. In addition, the sensitivity results for the tank contents of 8 M existing solution and 1.5 M incoming species show that the mixing time takes about 2 hours to get the solutions mixed.

42 ENGINEERING↗

Measure Guideline: Combined Space and Water Heating Installation and Optimization

Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗