At least 73 records · Page 4

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-atom catalysts with anionic metal centers: promising electrocatalysts for the oxygen reduction reaction and beyond

Ongoing efforts to develop single-atom catalysts (SACs) for the oxygen reduction reaction (ORR) typically focus on SACs with cationic metal centers, while SACs with anionic metal centers (anionic SACs) have been generally neglected. However, anionic SACs may offer excellent active sites for ORR, since anionic metal centers could facilitate the activation of O2 by back donating electrons to the antibonding orbitals of O2. In this work, we propose a simple guideline for designing anionic SACs: the metal centers should have larger electronegativity than the surrounding atoms in the substrate on which the metal atoms are supported. By means of density functional theory (DFT) simulations, we identified 13 anionic metal centers (Co, Ni, Cu, Ru, Rh, Pd, Ag, Re, Os, Ir, Pt, Au, and Hg) dispersed on pristine or defective antimonene substrates as new anionic SACs, among which anionic Au and Co metal centers exhibit limiting potentials comparable to, or even better than, conventional Pt-based catalysts towards ORR. We also found that anionic Os and Re metal centers on the defective antimonene can electrochemically catalyze the nitrogen reduction reaction (NRR) with a limiting potential close to that of stepped Ru(0001). Overall, our work shows promise towards the rational design of anionic SACs and their utility for applications as electrocatalysts for ORR and other important electrochemical reactions.

36 MATERIALS SCIENCE↗

Lehigh University Industrial Assessment Center (Final Technical Report for the Period 2016 to 2021)

This is the final technical report summarizing the activities Industrial Assessment Center at Lehigh University sponsored by the Department of Energy for the period September 1, 2016 till September 30, 2021. During this period, the Industrial Assessment Center at Lehigh University was successful in training numerous energy engineers of the future, and helped many manufacturing plants in New Jersey and Eastern Pennsylvania. The center and its activities helped save a great deal of energy, related fuel costs and along the way mitigated tons of CO2 emissions. The report covers many of the numerical details related to the center activities. The Industrial Center at Lehigh University is one of the most successful ones and this is made evident by the statistics included as part of this report and best center award bestowed upon the center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence for Data Center Operations (AIOps): Cooperative Research and Development (Final Report)

High performance computing data centers will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence and machine learning approaches provide the means to improve HPC data center operational efficiency, by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. NREL has developed methods of real-time collection, aggregation and streaming of these data in the ESIF HPC Data Center and has collected a significant dataset of relevant metrics across computer systems, racks, environmental, building and utility sources for research into various predictive analytics problems. HPE's Advanced Technology Group (ATG) is doing comprehensive research into exascale monitoring and management for High Performance Computing (HPC) systems (hereinafter HPE's Data Monitoring/ Management Technology). NREL and HPE will collaborate to add Artificial Intelligence (AI) to NREL's real-time data collection/ aggregation/ streaming system and HPE's Data Monitoring/ Management System, with the goal of improving the operational efficiency of NREL's Energy Systems Integration Facility (ESIF) HPC Data Center through data analytics on both historical and real-time data from IT systems and facilities operations. This collaboration will consist of efforts in Data Management, Data Analytics, and AI/ML Optimization for both manual and autonomous intervention in data center operations. This will be a multi-year, multi-staged effort with a goal towards building capabilities for an Advanced Smart Facility, and demonstration of these techniques in the NREL ESIF HPC Data Center.

97 MATHEMATICS AND COMPUTING↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Group-III quantum defects in diamond are stable spin-1 color centers

Color centers in diamond have emerged as leading solid-state “artificial atoms” for a range of quantum technologies, from quantum sensing to quantum networks. Concerted research activities are now underway to identify new color centers that combine stable spin and optical properties of the nitrogen vacancy (NV – ) with the spectral stability of the silicon vacancy (SiV – ) centers in diamond, with recent research identifying other group-IV color centers with superior properties. In this paper, we investigate a class of diamond quantum emitters from first principles, the group-III color centers, which we show to be thermodynamically stable in a spin-1, electric-field-insensitive structure. Further, from ab initio electronic structure methods, we characterize the product Jahn-Teller (pJT) effect present in the excited-state manifold of these group-III color centers, where we capture symmetry-breaking distortions associated with strong electron-phonon coupling. These predictions can guide experimental identification of group-III vacancy centers and their use in applications in quantum information science and technology.

36 MATERIALS SCIENCE↗

Drought and Extreme Heat Impacts to Data Centers in Northern California

Commonly, data centers are designed and operated on the assumption of stationarity of the climate. Historical weather data informs the basis of their design and operations. However, as a result of climate change, this assumption is not valid and poses a great risk for data centers. In the coming decades, Northern California’s drought and extreme heat risk is projected to increase significantly. This report provides a drought and extreme heat impacts assessment of data centers in this region. Expert solicitation of data center experts enabled a tailored approach to this report. We identify the climate variables and analytics relevant for assessing data center-specific impacts from extreme heat and drought and demonstrate how to access and understand future climate projections from climate models. We emphasize the importance of including future climate projections into data center design and planning. This report is an important first step towards building an effective extreme heat and drought adaptation strategy for data centers in Northern California. While our geographical focus in this report is Northern California, many findings in this report are broadly applicable.

58 GEOSCIENCES↗

Probing Charge Dynamics in Diamond with an Individual Color Center

Control over the charge states of color centers in solids is necessary to fully utilize them in quantum technologies. However, the microscopic charge dynamics of deep defects in wide-band-gap semiconductors are complex, and much remains unknown. We utilize a single-shot charge-state readout of an individual nitrogen-vacancy (NV) center to probe the charge dynamics of the surrounding defects in diamond. We show that the NV center charge state can be converted through the capture of holes produced by optical illumination of defects many micrometers away. With this method, we study the optical charge conversion of silicon-vacancy (SiV) centers and provide evidence that the dark state of the SiV center under optical illumination is SiV 2– . These measurements illustrate that charge carrier generation, transport, and capture are important considerations in the design and implementation of quantum devices with color centers and provide a novel way to probe and control charge dynamics in diamond.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix↗

Artificial Intelligence for Data Center Operations (AI Ops)

HPC data centers such as the one at NREL's ESIF will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence (AI) and machine learning (ML) approaches provide the means to improve HPC data center efficiency (energy, operational, and managerial efficiency) and resiliency by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. The goal of coupled improvement of data center resiliency and energy efficiency through automated data collection and AI has led to a multi-year, multi-staged collaboration between NREL and Hewlett-Packard Enterprise's Advanced Technology Group, referred to as Artificial Intelligence for Data Center Operations (AIOps). The extended efforts within the AIOps project include a common goal of building capabilities for an advanced smart facility and demonstration of data collection and AI modeling techniques in the ESIF data center.

97 MATHEMATICS AND COMPUTING↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navigating Integration: Key Challenges for Data Centers, Nuclear Stakeholders, and Utility Operators

The rapid expansion of data centers, driven by the exponential growth in data-processing and storage needs, presents significant challenges and opportunities for various stakeholders, including data center developers, nuclear energy providers, and utility companies. Data centers are projected to consume 6.7–12% of United States (U.S.) electricity by 2028, driven by artificial intelligence (AI) and cloud-computing demands. Nuclear energy offers reliability and dispatchable baseload power, but data centers need power now while nuclear still needs time to address siting, fast power ramping, and regulatory hurdles. Utilities must keep pace with the unprecedented acceleration of large load interconnection requests and urgently adapt to high-density loads while maintaining grid stability, reliability, and accelerating interconnection timelines. This report dives into these challenges and proposes key collaboration strategies to streamline data center integration that aligns with recent federal initiatives like America’s AI Action Plan and related executive orders that emphasize the importance of data center growth, nuclear energy expansion, and maintaining a competitive edge in the global AI race.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Integrating Data Centers and Grid Technologies at Scale

This presentation focuses on the challenge of integrating AI-driven data centers with the power grid at scale. It examines the AI data center capacity challenge and the role of new Medium Voltage Direct Current (MVDC) and other grid-enhancing technologies in enabling efficient and reliable power delivery. The session will highlight the National Laboratory of the Rockies' ARIES capabilities and planning tools, along with collaborative examples involving Verrus, Compass, and Schneider through the Agora test bed for grid-friendly data center evaluations, and ON. Energy for UPS evaluation. It will showcase the NLR Stable Grid Platform for studying oscillations caused by large-scale data centers, along with planning tools to assess grid security and reliability. Additionally, the presentation covers reconductoring strategies to increase grid capacity and explores innovative data center architectures, including the Advanced DC Architectures with Power-electronic Transformers (ADAPT) platform, which enables testing of complete DC architectures for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗