Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ceil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of the Acoustic Measurement Capability of the NASA Langley V/STOL Wind Tunnel Open Test Section with Acoustically Absorbent Ceiling and Floor Treatments

The single source location used for helicopter model studies was utilized in a study to determine the distances and directions upstream of the model accurate at which measurements of the direct acoustic field could be obtained. The method used was to measure the decrease of sound pressure levels with distance from a noise source and thereby determine the Hall radius as a function of frequency and direction. Test arrangements and procedures are described. Graphs show the normalized sound pressure level versus distance curves for the glass fiber floor treatment and for the foam floor treatment.

Theobald, M. A.↗

Ceiling Fires Studied to Simulate Low-Gravity Fires

A unique new way to study low-gravity flames in normal gravity has been developed. To study flame structure and extinction characteristics in low-stretch environments, a normal gravity low-stretch diffusion flame was generated using a cylindrical PMMA sample of varying large radii, as shown in the photograph. These experiments have demonstrated that low-gravity flame characteristics can be generated in normal gravity through the proper use of scaling. On the basis of this work, it is feasible to apply this concept toward the development of an Earth-bound method of evaluating material flammability in various gravitational environments from normal gravity to microgravity, including the effects of partial gravity low-stretch rates such as those found on the Moon (1/6g) or Mars (1/3g). During these experiments, the surface regression rates for PMMA were measured for the first time over the full range of flammability in air, from blowoff at high stretch, to quenching at low stretch, as plotted in the graph. The solid line drawn through the central portion of the data (3<a<100 sec-1) has a slope of unity, which indicates regression is proportional to stretch. The figure coordinates assume that the values of stretch are equivalent, whether derived from forced stretch or from buoyant stretch. The excellent correlation of the regression-rate data over the two-order-of-magnitude variation of stretch shows the reasonableness of this assumption.

Olson, Sandra L.↗

Stable Low Cloud Phase II: Nocturnal Event Study

This report describes the work done by the Applied Meteorology Unit (AMU) in developing a database of nights that experienced rapid (< 90 minutes) low cloud formation in a stable atmosphere, resulting in ceilings at the Shuttle Landing Facility (TTS) that violated Space Shuttle Flight Rules (FR). This work is the second phase of a similar AMU task that examined the same phenomena during the day. In the first phase of this work, the meteorological conditions favoring the rapid formation of low ceilings include the presence of any inversion below 8000 ft, high relative humidity (RH) beneath the inversion and a clockwise turning of the winds from the surface to the middle troposphere (-15000 ft). The AMU compared and contrasted the atmospheric and thermodynamic conditions between nights with rapid low ceiling formation and nights with low ceilings resulting from other mechanisms. The AMU found that there was little to discern between the rapidly-forming ceiling nights and other low ceiling nights at TTS. When a rapid development occurred, the average RH below the inversions was 87% while non-events had an average RH of 79%. One key parameter appeared to be the vertical wind profile in the Cape Canaveral, FL radiosonde (XMR) sounding. Eighty-three percent of the rapid development events had veering winds with height from the surface to the middle troposphere (-15,000 ft) while 61% of the non-events had veering winds with height. Veering winds indicate a warm-advection regime, which supports large-scale rising motion and ultimately cloud formation in a moist environment. However, only six of the nights (out of 86 events examined) with low cloud ceilings had an occurrence of rapidly developing ceilings. Since only 7% rapid development events were observed in this dataset, it is likely that rapid low cloud development is not a common occurrence during the night, or at least not as common as during the day. In the AMU work on the daytime rapid low cloud development (Case and Wheeler 2005), nearly 30% of the low cloud ceiling cases investigated were identified as rapidly developing events. Forecasters at the Space Meteorology Group (SMG) issue 30 to 90 minute forecasts for low cloud ceilings at TTS to support Space Shuttle landings. Mission verification statistics have shown ceilings to be the number one forecast challenge. More specifically, forecasters at SMG are concerned with any rapidly developing clouds/ceilings below 8000 R in a stable, capped thermodynamic environment. Therefore, the AMU was tasked to examine archived events of rapid stable cloud formation resulting in ceilings below 8000 ft, and document the atmospheric regimes favoring this type of cloud development. The AMU examined the cool season months of November to March during the years of 1994-2005 for nights that had low-level inversions and rapid, stable low cloud formation that resulted in ceilings violating the Space Shuttle FR. The AMU wrote and modified existing code to identify inversions from the evening and morning XMR radiosonde during the cool season and output pertinent sounding information. They parsed all days with cloud ceilings below 8000 ft at TTS, forming a database of possible rapidly-developing low ceiling events. Nights with precipitation or noticeable fog burn-off situations were excluded from the database. Only the nighttime hours were examined for possible ceiling development events since the daytime events were examined in the first phase of this work. The report presents one sample case of rapidly-developing low cloud ceilings. The case depicts the representative meteorological and thermodynamic characteristics of such events. The case also illustrates how quickly the cloud decks can develop, sometimes forming in 30 minutes or less. The report also summarizes the composite meteorological conditions for 6 event nights with rapid low cloud ceiling formation and 80 non-events nights consisting of advection or widespread low cloud ceilings. The teorological conditions were quite similar for both the event and non-event nights, since both types of nights experienced low cloud ceilings. Both types of nights had a relatively moist environment beneath an inversion based below 8000 ft.

Bauman, William H., III↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Vertical Translation System for the Common Habitat Architecture

The Common Habitat is a large, long-duration habitat that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. Measuring 8.4 meters in diameter and 15 meters in length, it is manufactured as a habitat and launched as such into space. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. The Common Habitat Vertical Translation System provides a means for transporting crew and cargo between decks in a Common Habitat spacecraft in gravity levels varying from 0g to 1g. A crowdsourcing campaign was conducted through the GrabCAD platform to initially solicit ideas for restraints and mobility aids, including vertical translation. Four of the five top responses repeated ideas that would be incorporated into features of the Vertical Translation System. The first was a safety barrier (to prevent falls into the opening between decks) that could collapse to form a floor surface covering the opening when not in use. The second idea was a folding ladder that could be stowed in the ceiling when not in use. The third idea was an elevator platform that could traverse the ladder. Several key driving requirements were established for the Vertical Translation System: it may not penetrate into or through the lower deck; it must work on the Earth, Moon, Mars, and in microgravity; it must be easy to operate; it must enable translation of any item that can fit through the Common Habitat’s 40” x 60” hatches, inclusive of suited and unsuited crew with any degree of incapacitation and any equipment or cargo item; and it must include three component systems – deploying floor / safety barriers, a deployable ladder, and an elevator platform. Additional requirements were established for each of the component systems. The safety barriers must form a roughly 40-inch tall, complete wall enclosure on all four sides when deployed; it must include an easy to open gate that allows access to/from the ladder when deployed; and when retracted, the safety barrier must form a smooth, load-bearing floor that can be walked on, and wheeled objects can be rolled across in gravity, without being a trip hazard. The deployable ladder must be composed of multiple ladders that work together; it must stow in the ceiling when not in use; and it must not penetrate into the 40” x 60” vertical passage corridor. The elevator platform must work with the deployable ladder system; it must be able to bridge any gap in ladders between decks; it must stop at each deck flush with the deck surface; it must be capable of transporting an incapacitated crew member as a single rescuer operation; it must be capable of transporting a full-size subsystems pallet; it must function as an elevator for a crew member carrying large objects; it must have safety functions to prevent falls from the platform, or crew/cargo collisions with edges of hatch openings, or entanglement with ladder rungs/structure; it must stow when not in use; and it must autonomously both connect itself to the ladder and deploy itself to any deck where needed when called (e.g., a crew member on any deck can call for the platform and it must connect itself to the ladders without assistance and translate to the requestor’s deck). These requirements were developed into a system concept with the assistance of a NASA Pathways Intern who also added the requirement to size the design based on the use of commercial components, using existing motors and other mechanisms to ensure that the resulting system could be inexpensively produced. The Floor and Safety Barrier consists of four panels, two roughly 40 inches long and two roughly 60 inches long that can fold into the floor on top of each other when not in use. The uppermost panel is load bearing and acts as the floor surface. When deployed, they connect with each other to form a rigid barrier surrounding the vertical passageway. One of the panels contains a hinged gate that can be opened when deployed to allow for access to/from the passageway. The Deploying Ladder consists of two ladder segments, one mounted on the ceiling of the lower deck and the other mounted on the ceiling of the mid deck. A rotating mechanism is mounted on the ladder to allow it to rotate into a horizontal position against the ceiling for stowage, or down to a vertical position for use. A second rotating mechanism is built into the ladder, allowing the rungs to rotate. A toothed surface intended to work with the elevator platform covers the front of the ladder rails and the top and bottom of the rails are designed to be flush when aligned with another ladder segment. The elevator platform is essentially a motorized, self-propelled deck. It has a mechanism that holds it in contact with the ladder rails and drives itself against the toothed surface. This mechanism allows the elevator platform to ascend or descend the ladder. In order to stow the platform when not in use, a set of short ladder rails (without rungs) are mounted to the ceiling of the mid deck. When the mid deck ladder is stowed, it is flush with these rails and the platform can drive itself onto those short rails for stowage. An additional mechanism on the platform can pitch its deck surface 90 degrees, such that when the ladder is to be stowed, the platform can fold up against the ceiling. As a consequence of the ladder and elevator platform design, the opening between decks in the Common Habitat was enlarged to ensure that the elevator platform can accept a payload up to 40”x60” in dimension.

Human Centered Design↗

Flammability and dispersion of tritium in confined release scenarios

Ignition of a flammable tritium-air mixture is the most probable means to produce the water form (T 2 O or HTO), which is more easily absorbed by living tissue and is hence ~10,000 times more hazardous to human health when uptake occurs compared to the gaseous form (T 2 or HT; per Mishima and Steele, 2002). Tritium-air mixtures with T 2 concentrations below 4 mol% are considered sub-flammable and will not readily convert to the more hazardous water form. It is therefore desirable from a safety perspective to understand the dispersion behavior of tritium under different release conditions, especially since tritium is often stored in quantities and pressures much lower than is typical for normal hydrogen. The formation of a flammable layer at the ceiling is a scenario of particular concern because the rate of dispersion to nonflammable conditions is slowest in this configuration, which maximizes the time window over which the flammable tritium may encounter an ignition source. This report describes the processes of buoyant rise and dispersion of tritium. Accumulation of flammable concentrations of tritium next to the ceiling is a common safety concern for hydrogen, but this situation can only occur if dispersion rates are slow with respect to rates of release and rise. Theory and simulations demonstrate that buoyancy does not cause regions with flammable concentrations to form within buildings from sources that have previously been mixed to sub-flammable concentrations. A simulated series of tritium release events with their associated dispersion behavior are reported herein; these simulations apply computational fluid dynamics to rooms with three different ceiling heights and a variety of tritium release rates. Safety related quantities from these simulations are reported, including the mass and volume of tritium occurring in a flammable mixture, the presence or absence of a flammable layer at the ceiling, and the time required for dispersion to nonflammable conditions after the end of the tritium release event. These safety metrics are influenced by the magnitude and rate of the tritium release with respect to the air volume in the room and also the momentum of the plume or jet with respect to the ceiling height. Several screening criteria are recommended to assess whether a specific tritium release scenario is likely to form a flammable layer at the ceiling. The methods and results in this modeling study have applicability to explosion safety analysis for other buoyant flammable gases, including the lighter isotopes of hydrogen.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Head-up transition behavior of pilots during simulated low-visibility approaches

Each of 13 commercial pilots from four airlines flew a total of 108 manual flight director approaches in a moving base simulation of a medium-sized turbojet (95,000 lb gross weight) which had a day and night Redifon external scene. Three levels of runway visual range (RVR) (1,600; 2,400; and greater than 8,000 ft), three wind-shear profiles, nine ceiling heights, and continuous and intermittent visibility after initial breakout were tested. The results indicated that: (1) mean decision time ranged from 2 to 4.6 sec for ceilings under 380 ft across the three RVR conditions; (2) mean vertical distance traveled during the visual-cue assessment period was a relatively constant proportion below the existing ceiling; (3) a significant three way interaction in mean decision time between wind shear, day-night, and ceiling RVR variables occurred; (4) mean number of head-up transitions to VFR conditions after breakout ranged from 4.6 to 13.4 and increased as a function of ceiling and severity of wind shear; the typical duration of fixation out the window was 1.5 sec; and (5) subjective pilot ratings of controllability and precision of control as well as amount of skill, attention, or effort required to make the landing were influenced significantly by the wind shear, night conditions, and low breakout ceiling conditions.

Haines, R. F.↗

A Preliminary Analysis of Dose Rates Associated with ITER CVCS Equipment/Area Location

A preliminary analysis of the ITER Chemical and Volume Control System (CVCS) Area was performed to assess dose rates outside the walls and ceiling of the facility after 1.5 years of operation at shutdown, 2 days, and 10 days after shutdown. For this purpose a simplified Monte Carlo computer model was developed using the MCNP (MCNP5 Ver. 1.51) code. Two components are included: the smaller filter tank and the larger ion exchanger. These pieces of equipment are associated with the Integrated Blanket ELM Divertor Primary Heat Transfer System, which will have the largest dose rates associated with activated corrosion products during operation in comparison with other systems. The ion exchanger contained two source regions, a 1.2-m-thick resin bed above a 0.55 m-thick skirt, and a 0.8-m-thick water region. The filter constituted an additional source. Thus the model consisted of three sources (filter, resin, water), homogeneously distributed within the appropriate source regions. However, much of the results (that address individual isotopes) are presented with the two sources in the ion exchanger combined. In these cases the sources are referred to as the 'ion exchanger source' and the 'filter source.' Dimensions for the facility and components, as well as source isotopes and strengths, and material densities, were supplied by US ITER. Because of its simplification, the model does not contain pipes. Consequently, radiation streaming through pipe penetrations, radiation emanating from the pipes, and shielding from the pipes were not considered in this analysis. Dose rates on the outside of two walls and the ceiling were calculated. The two walls are labeled as the 'long' wall (aligned with the X-axis) and the 'short' wall (aligned with the Y-axis). These walls and ceiling were nominally set to 30-cm-thick concrete. In the original analysis, standard concrete (2.3 g/cc density) was used. In addition to the shielding walls/ceiling, a floor and an additional wall opposite the long wall were added for photon scattering contributions. These were both 10-cm-thick, standard concrete structures. Other components (tanks, pipes, etc.), that were not included in the model, would potentially add additional scattering and shielding. Possibly these additional effects will be addressed in a later, more detailed analysis. The room was 29.6 m in length (X-axis), but was limited to 15 m in the model. The inside width (Y axis) and height (Z axis) were 4 m and 3.4 m, respectively. The origin for the model was located inside the room at the corner opposite the long wall and adjacent to the short wall at the floor level. The room was filled with air at standard temperature and pressure. The stainless steel (SS304) wall thicknesses for the ion exchanger and filter were 2.2 cm and 0.8 cm, respectively. The axial center of the filter was located 140 cm from the short wall and 100 cm from the long wall (outer surface). The axial center of the ion exchanger was located 440 cm from the short wall and 250 cm from the long wall (inner surface). The resin was assumed to be a homogeneous mixture of equal atom density fractions of hydrogen and carbon* at a specified density of 1.136 g/cc. The filter material was assumed to be homogeneous carbon at a specified density of 1.8 g/cc. If the filter media were stainless steel and the accumulated activity were the same, the dose rate outside the filter would be lower, provided the density of the stainless steel sintered filter material is significantly higher than 1.8g/cc. The densities of the water and air were assumed to be 1.0 g/cc and 1.096E-3 g/cc, respectively. The model included 10 small volumes placed outside the model adjacent to the wall at locations where the dose rates were expected to be highest and which showed to a degree the fall-off of the dose rate with distance along a particular wall or ceiling. These 'tally cells' are shown in Fig. 2 and are described in Table 1. Each cell had dimensions of 50 cm x 50 cm x 1 cm and was oriented so that the 1-cm-thick dimension was perpendicular to the wall against which the cell was located. Also, smaller tally volumes were placed at 5 cm (updated model), 30 cm, 50 cm, and 100 cm from each source, both radially from the outside of each component at the height of each source mid-plane, and vertically, along the axial centerline, above the ion-exchanger and below the filter. (For the ion exchanger, the vertical distance was limited to 75 cm because of interference from the ceiling.) These tally regions can be seen in Fig. 3. Each cell had dimensions of 5 cm x 5 cm x 1 cm, oriented so that the 1-cm-thick dimension was perpendicular to the X, Y or Z axis.

08 HYDROGEN↗

Validation Study of Experimental Insulating and Air-Sealing Technology for Enclosed Roof Cavities

Validation Study of Experimental Insulating and Air-Sealing Technology for Enclosed Roof Cavities, explores a new minimally invasive system known as Pinhole Insulation ® for retroft insulation of cathedral ceilings, flat roofs, dormer roofs, and other enclosed roof cavities. It also explores the validation of the associated equipment, software, and materials used in this application. The Pinhole Insulation process essentially consists of drilling a ¼” hole in the ceiling surface and then injecting closed cell polyurethane foam such that the foam is deposited on the interior surface of the exterior roof sheathing. In a typical cathedral ceiling with R19 batts, the R value will be improved by at least 60% and the cavity will become completely air sealed. The system is quick, minimally invasive and at least an order of magnitude less expensive than alternatives such as removing the ceiling surface and spraying closed cell foam.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The DESI One-Percent Survey: exploring a generalized SHAM for multiple tracers with the UNIT simulation

We perform SubHalo Abundance Matching (SHAM) studies on UNIT simulations with {σ, V ceil , v smear }-SHAM and {σ, V ceil , $f$ sat }-SHAM. They are designed to reproduce the clustering on 5–30 h -1 Mpc of luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasi-stellar objects (QSOs) at 0.4 < z < 3.5 from DESI (Dark Energy Spectroscopic Instrument) One Percent Survey. V ceil is the incompleteness of the massive host (sub)haloes and is the key to the generalized SHAM. v smear models the clustering effect of redshift uncertainties, providing measurements consistent with those from repeat observations. A free satellite fraction $f$ sat is necessary to reproduce the clustering of ELGs. We find ELGs present a more complex galaxy–halo mass relation than LRGs reflected in their weak constraints on σ. LRGs, QSOs, and ELGs show increasing V ceil values, corresponding to the massive galaxy incompleteness of LRGs, the quenched star formation of ELGs and the quenched black hole accretion of QSOs. For LRGs, a Gaussian v smear presents a better profile for subsamples at redshift bins than a Lorentzian profile used for other tracers. The impact of the statistical redshift uncertainty on ELG clustering is negligible. The best-fitting satellite fraction for DESI ELGs is around 4 per cent, lower than previous estimations for ELGs. The mean halo mass log 10 ($\langle$M vir $\rangle$) in h -1 M ⊙ for LRGs, ELGs, and QSOs are 13.16 ± 0.01, 11.90 ± 0.06, and 12.66 ± 0.45, respectively. Our generalized SHAM algorithms facilitate the production of multitracer galaxy mocks for cosmological tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Heat Transfer Through a Passive Fire Protective Board from an Impinging Hydrogen Flame

This report documents analysis to determine whether a hydrogen jet flame impinging on a tunnel ceiling structure could result in permanent damage to the Callahan tunnel in Boston, Massachusetts. This tunnel ceiling structure consists of a passive fire protective board supported by stainless steel hangers anchored to the tunnel ceiling with epoxy. Three types of fire protective boards were considered to determine whether heat from the flame could reach the stainless-steel hangers and the epoxy and cause the ceiling structure to collapse. Heat transfer analyses performed showed that the temperature remains constant where the steel hangers are attached to the passive fire protective board. According to these results, the passive fire protective board should provide adequate protection to the tunnel structure in this release scenario. Tunnel structures with similar suspended fire-resistant liner board materials should protect the integrity of the structure against the extremely low probability of an impinging hydrogen jet flame.

08 HYDROGEN↗

An experimental investigation of the effect of boundary layer refraction on the noise from a high-speed propeller

Models of supersonic propellers were previously tested for acoustics in the Lewis 8- by 6-Foot Wind Tunnel using pressure transducers mounted in the tunnel ceiling. The boundary layer on the tunnel ceiling is believed to refract some of the propeller noise away from the measurement transducers. Measurements were made on a plate installed in the wind tunnel which had a thinner boundary layer than the ceiling boundary layer. The plate was installed in two locations for comparison with tunnel ceiling noise data and with fuselage data taken on the NASA Dryden Jetstar airplane. Analysis of the data indicates that the refraction increases with: increasing boundary layer thickness; increasing free stream Mach number; increasing frequency; and decreasing sound radiation angle (toward the inlet axis). At aft radiation angles greater than about 100 deg there was little or no refraction. Comparisons with the airplane data indicated that not only is the boundary layer thickness important but also the shape of the velocity profile. Comparisons with an existing two-dimensional theory, using an idealized shear layer to approximate the boundary layer, showed that the theory and data had the same trends. Analysis of the data taken in the tunnel at two different distances from the propeller indicates a decay with distance in the wind tunnel at high Mach numbers but the decay at low Mach numbers is not as clear.

Dittmar, J. H.↗

Progress in wind tunnel wall interference assessment/correction procedures at the NAE

Wall corrections as a function of wall porosity in the transonic wall interference problem was assessed. Effective porosities primarily for the two dimensional case were established as follows: (1) comparison of experimental data for two geometrically similar models of different chord/height ratio, an overall value of wall porosity could be deduced; (2) theoretical development which allows for unequal porosity for the floor and ceiling and wall boundary pressure measurements, porosities for floor and ceiling could be deduced; (3) a scheme was developed which allowed unequal porosity of floor and ceiling and streamwise varying porosity. The boundary layer development along the perforated floor and ceiling under the influence of the model pressure field, variations in boundary layer thickness underlining the difficulties in deducing meaningful values of wall porosity were determined. Wall boundary pressure measurement, in combination with singularity modelling of the airfoil, was sufficient to yield required information on the wall interference flow without having to establish some value for wall porosity. The singularity modelling of the airfoil initially covered only lift and volume but was extended to include drag and pitching moment, and second order volume term. It is shown by asymptotic transonic small disturbance analysis, that the derived corrections to angle of attack and free stream Mach number are correct to the first order.

Ohman, L. H.↗

Lead Paint Exposure Assessment in High Bays of Johnson Space Center

This slide presentation reviews the program to assess the possibility of lead paint exposure in the high bays of some of the Johnson Space Center buildings. Some of the buildings in the Manned Space Flight Center (MSC) were built in 1962 and predate any considerations to reduce lead in paints and coatings. There are many of these older buildings that contain open shops and work areas that have open ceilings, These shops include those that had operations that use leaded gasoline, batteries, and lead based paints. Test were planned to be conducted in three phases: (1) Surface Dust sampling, (2) personal exposure montioring, and (3) Ceiling paint Sampling. The results of the first two phases were reviewed. After considering the results of the first two phases, and the problems associated with the retrieval of samples from high ceilings, it was determined that the evaluation of ceiling coatings would be done on a project by project and in response to a complaint.

Stanch, Penney↗