Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Magnetically Arrested Circumbinary Accretion Flows

Abstract Binary systems with comparable masses and a surrounding accretion disk can accrete gas through spiral accretion streams penetrating the central cavity formed by tidal interactions. Using three-dimensional Newtonian magnetohydrodynamics simulations, we investigate the possibility of a magnetically arrested accretion flow through the cavity. Rather than solely continuously feeding the binary through spiral accretion streams, the accretion is regulated by the strong magnetic field inside the cavity. Transport of mass and angular momentum onto the binary then proceeds largely periodically in magnetic flux eruption episodes. The ejected flux tubes carry angular momentum outward and away from the binary, inject hot plasma into the disk, and can launch flares. This likely intermittent scenario could have potential implications for the emission signatures of supermassive black hole binaries and shed light onto the role magnetic fields play in the binary’s orbital evolution.

Astronomy & Astrophysics↗

Time-resolved 3D imaging of two-phase fluid flow inside a steel fuel injector using synchrotron X-ray tomography

The multiphase flow inside a diesel injection nozzle is imaged using synchrotron X-rays from the Advanced Photon Source at Argonne National Laboratory. Through acquisitions performed at several viewing angles and subsequent tomographic reconstruction, in-situ 3D visualization is achieved for the first time inside a steel injector at engine-like operating conditions. The morphology of the internal flow reveals strong flow separation and vapor-filled cavities (cavitation), the degree of which correlates with the nozzle's asymmetric inlet corner profile. Micron-scale surface features, which are artifacts of manufacturing, are shown to influence the morphology of the resulting liquid-gas interface. The data obtained at 0.1 ms time resolution exposes transient flow features and the flow development timescales are shown to be correlated with in-situ imaging of the fuel injector's hydraulically-actuated valve (needle). As more than 98.5% of the X-ray photon flux is attenuated within the steel injector body itself, we are posed with a unique challenge for imaging the flow within. Time-resolved imaging under these low-light conditions is achieved by exploiting both the refractive and absorptive properties of X-ray photons. The data-processing strategy converted these images with a signal-to-noise ratio of similar to 10 into a meaningful dataset for understanding internal flow and cavitation in a nozzle of diameter 200 mu m enclosed within 1-2 millimeters of steel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid helium fluid dynamics studies. Final Technical Report

Future high energy physics accelerators depend on a number of advanced technologies to open the many doors of scientific discovery. Among these advanced technologies, superconducting magnets and superconducting radio frequency (SRF) cavities are the backbone of the accelerator and detector systems. But all these low temperature systems depend critically on successful and reliable operation of their supporting technologies, among which the liquid helium cooling system is of the utmost importance. To improve the quality of these systems both in terms of efficiency and reliability, a robust helium cryogenics research and development (R&D) effort is required. The proposed research to be conducted by the FSU cryogenics group aims to produce fundamental knowledge that meets this R&D need. The projects that we have completed over the past grant period at Florida State University consist of experimental research on liquid helium fluid dynamics and heat transfer problems relevant to the development of future superconducting particle physics accelerators. Liquid helium is the coolant used in all such facilities and in many of these facilities He II (the low temperature phase of liquid helium also known as superfluid helium) is preferred due to its outstanding heat transfer characteristics. The work consists of two main experimental studies that probe both fundamental as well as practical aspects of liquid helium cooling. The first is a broad and fundamental study of the heat and mass transfer processes that can occur during a sudden catastrophic loss of vacuum (SCLV) incident in a superconducting accelerator. SCLV refers to the remote but extremely critical accident scenario where atmospheric pressure air is allowed to flood into the insulating vacuum system and impinge on the liquid helium cooled surfaces in the accelerator. Safe performance and recovery from such accidents is essential to the reliable operation of superconducting accelerators. The dynamics of this process is quite complex and so our approach is to conduct a series of well-orchestrated experiments that probe the various physical phenomena that can occur during an SCLV event. The experiments are coupled with analytic and numerical analysis in an effort to develop a general understanding of the process and to assist with future accelerator design and development. The second activity is directed toward fundamental understanding of heat and mass transfer in He II, which is essential to the design of superconducting magnets and radio frequency cavities in accelerators. The work consists of flow visualization of the dynamics of He II using laser assisted techniques. Two complementary techniques are used to study the fundamentals of the turbulent state. The first technique uses neutrally buoyant solid hydrogen particles to probe the flow fields of the superfluid and normal fluid components. The other technique uses laser excited He2* molecules as tracers of the normal fluid motion within the He II. The activities also included an effort to use visualization techniques to locate transient hot spots in radio frequency superconducting cavities. Such work provides valuable information about the heat transfer process in He II and its impact on the performance of superconducting devices. The research effort at Florida State University is not directly in support of a specific high energy physics experiment or facility. Rather, the work is general and coordinated with HEP accelerator laboratories to provide valuable insight that can assist with future accelerator development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment and Improvement Proposals for High-Pressure Rinsing Processes during Cleanroom Preparation of Superconducting Radio-Frequency Cavities for Particle Accelerators

The goal of this internship is to develop a fluid dynamics characterization of the high-pressure flow used for cleaning the internal surface of the SRF cavities. Initially, the High Pressure Rinsing (HPR) process is introduced, focusing on the problems of the SRF cavities and how this method can be used to increase their acceleration efficiency and performance. The characterization of the problem is then presented, including an introduction to the multiphase flow modeling and the analysis of the Fermilab facility for the HPR. To accomplish the goal, a preliminary estimation of the variables was performed using MATLAB. Then, multiple 2D simulations were developed with Ansys Fluent, and the influence of the main parameter was investigated. The simulation results are then presented and analysed, with a focus on the possible future developments of the HPR process fluid dynamic characterization.

43 PARTICLE ACCELERATORS↗

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparative study with two reduced test facilities for air-cooled RCCS scaling law

Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL) conducted steady-state tests at constant heat flux conditions to investigate the scale effect on heat removal behavior of the air-cooled Reactor Cavity Cooling System (RCCS). Two differently scaled-down test facilities were used in this study, KAERI’s ¼ scale with 4.0-m cavity height, and ANL’s ½ scale with 6.8-m cavity height. Two scaling laws were proposed to simulate the radiation across the cavity and the buoyancy-driven duct flow in the riser, respectively. The test matrix for KAERI and ANL test facilities focused on the scaling effect of the heated riser length with constant heat flux at the PMR200 RCCS design. The test results showed that mixed convection in the riser duct is an important factor for accurately extrapolating the thermo-fluid behavior in the prototype from the test results in the scale-down facilities. The system analysis code, GAMMA+, with improved heat transfer models predicted fairly well the air-cooled RCCS test data from two facilities. GAMMA+ analysis results showed that the predicted radiation fractions on the heated plate in the scale-down test conditions were larger than those on the reactor vessel in the prototype. The scaling law for air-cooled RCCS was improved by considering the mixed convection in the riser duct and the same radiation fraction on the heated plate. The mixed convection effect was calculated by the height ratio. The same radiation fraction provided a conservative extrapolation from the scale-down test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temperature Homogeneity under Selective and Localized Microwave Heating in Structured Flow Reactors

Selective heating of different phases of multiphase systems via microwaves can result in energy savings and suppression of side reactions. However, materials properties and operating conditions that maximize temperature gradients are poorly understood. Here we utilize computational fluid dynamics (CFD) computations and temperature measurements in structured flow reactors (monoliths) in a monomodal microwave cavity to assess the temperature difference between the walls and the fluid and develop a simple lumped model to estimate when temperature gradients exist. We also explore the material’s thermal and electrical properties of structured reactors for isothermal catalyst conditions. We propose that CFD simulations can be used as a nonintrusive, predictive tool of temperature homogeneity. Importantly, we demonstrate that localized heating in the bed under several conditions rather than selective heating is responsible for the selectivity enhancement. Furthermore, our results indicate that structured beds made of high thermal conductivity materials avoid arcing and enable temperature homogeneity and low electrical conductivity materials allow microwaves to penetrate the domain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pre-Sinkhole Seismicity at the Napoleonville Salt Dome: Implications for Local Seismic Monitoring of Underground Caverns

The formation of a sinkhole at the Napoleonville salt dome located near Bayou Corne in Assumption Parish, Louisiana, was preceded by an increase in seismicity, as observed 10 km away by a continuously recording broadband seismic sensor. The seismicity rate in the days prior to the sinkhole formation contained hundreds of long-period events, some of which could be detected using a power detector (short-term to long-term energy ratio) tuned to the duration and frequency content of the seismicity. A characteristic of some of these events is a resonance near 0.4 Hz, which could be due to either an acoustic resonance within the brine-filled cavity or possibly due to unsteady fluid flow through a crack. In this work, a more exhaustive catalog was obtained using some of the events detected by the power detector as templates in a correlation detector. Furthermore, the full pre-sinkhole sequence of detections could offer lessons in remote monitoring of underground caverns.

58 GEOSCIENCES↗

Summary Report Of The FY25 Computational Fluid Dynamics Verification And Validation Exercises In The Advanced Reactor Technologies - Gas-cooled Reactor Program

Verification and Validation (V&V) of numerical tools is critical for ensuring reasonable predictions during design, safety analysis, and licensing. Recent work in the Advanced Reactor Technologies - Gas-cooled Reactor (ART-GCR) program has focused on V&V of common Computational Fluid Dynamics (CFD) tools that are used within the Untied States. This report presents an update on these CFD V&V activities. These Generation IV Forum (GIF) Very High Temperature Reactor (VHTR) Computational Methods, Validation, and Benchmarking (CMVB) is an international organization dedicated to the verification and validation of High Temperature Gas-Cooled Reactor (HTGR) simulation tools. Participation in the CMVB provides additional value to the V&V activities, as it allows for access to a wider range of data, and provides valuable benchmarking exercises. Three HTGR phenomena are targeted: Reactor Cavity Cooling System (RCCS) performance, core bypass flow, and lower plenum mixing. Simulations of the University of Wisconsin-Madison (UW-Madison) RCCS facilities are performed with Reynolds Averaged Navier-Stokes (RANS) in StarCCM+. Results are compared for both forced and natural convection conditions, with both exhibiting good agreement with experimental measurements. The Idaho National Laboratory (INL) matched index of refraction (MIR) and Korean Atomic Energy Research Institute (KAERI) bypass flow expeirments are used to validation CFD predictions of bypass flow. Simulations are performed with RANS in StarCCM+ and with Large Eddy Simulation (LES) in NekRS. Finally, preliminary simulations of the Institute of Nuclear and New Energy Technology (INET) lower plenum mixing facilities are presented. Initial work has developed models with LES, RANS, and porous media models. These preliminary models are presented and compared to each other to gauge differences in predictions with each of the three methods.

and Benchmarking (CMVB)↗

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Explainable Data-Driven Turbulence Models with Application to Liquid Fuel Nuclear Reactors

Liquid fuel nuclear reactors offer innovative possibilities in terms of nuclear reactor designs and passive safety systems. Molten Salts Reactors (MSRs) with a fast spectrum are a particular type of these reactors using liquid fuel. MSFRs often involve large open cavities in their core in which the liquid fuel circulates at a high speed to transport the heat generated by the nuclear reactions into the heat exchangers. This high-speed flow yields a turbulent field with large Reynolds numbers in the reactor core. Since the nuclear power, the neutron precursor’s transport and the thermal exchanges are strongly coupled in the MSFR’s core cavity, having accurate turbulent models for the liquid fuel flow is necessary to avoid introducing significant errors in the numerical simulations of these reactors. Nonetheless, high-accuracy simulations of the turbulent flow field in the reactor cavity of these reactors are usually prohibitively expensive in terms of computational resources, especially when performing multiphysics numerical calculations. Therefore, in this work, we propose a novel method using a modified genetic algorithm to optimize the calculation of the Reynolds Shear Stress Tensor (RST) used for turbulence modeling. The proposed optimization methodology is particularly suitable for advanced liquid fuel reactors such as the MSFRs since it allows the development of high-accuracy but still low-computational-cost turbulence models for the liquid fuel. We demonstrate the applicability of this approach by developing high accuracy Reynolds-Averaged Navier–Stokes (RANS) models (averaged flow error less than 5%) for a low and a large aspect ratio in a Backward-Facing Step (BFS) section particularly challenging for RANS models. The newly developed turbulence models better capture the flow field after the boundary layer tipping, over the extent of the recirculation bubble, and near the boundary layer reattachment region in both BFS configurations. The main reason for these improvements is that the developed models better capture the flow field turbulent anisotropy in the bulk region of the BFS. Then, we illustrate the interest in using this turbulence modeling approach for the case of an MSFR by quantifying the impact of the turbulence modeling on the reactor key parameters.

42 ENGINEERING↗

Evaluating the Effects of Transient Purge Flow on Stator-Rotor Seal Performance

Abstract As modern engine designs target higher efficiencies through increased turbine inlet temperatures, critical turbine components are at increased risk of damage from conditions exceeding material melting temperatures. In particular, improperly designed underplatform hardware components are susceptible to damage when hot main gas path flow is ingested into the stator-rotor cavity. While all turbines inherently experience transients during operation, a majority of publicly available turbine studies have been executed using steady operating conditions or inherently transient “blowdown” rigs. For this reason, routine transient events are not well understood. To address this need, the present study utilized a combined experimental and computational approach. The test article is a continuous-duration, one-stage test turbine operating with true-scale engine hardware and seal geometries at engine-representative flow conditions. The nature of the continuous-duration facility uniquely supports the direct assessment of transient events through its ability to transition between steady-state operating conditions. The effects of a transient purge flow were investigated in this study to identify general trends for transient events in a full-scale engine. Results from multiple measurement techniques in the wheelspace region show an interdependence of transient purge flow with a thermal lag of the underplatform hardware. Through experiments conducted at different coolant-to-main gas path temperature ratios, the use of pressure measurements as an indicator of fully purged behavior was introduced, and a thermally driven influence on rim seal performance was quantified. The computational results show good agreement with experimental pressure measurements and provide insight into the physical mechanisms that drive the relationship between pressure and sealing effectiveness measurements observed for the tested geometry.

Engineering↗

Towards Field Emission Free Cavity Processing and String Assembly at Fermilab

Cavities and cryomodules assembled at Fermilab have demonstrated unprecedented field emission (FE) free gradients. However, consistent FE-free performance is not guaranteed. Many lessons were learned, and continued vigilance is a must. In addition, several improvements have been identified to further push the state-of-the-art low particulate cavity processing and assembly at Fermilab. Those included the optimization of nitrogen flow, robotic-assisted assembly, and low-particulate fasteners. We share our latest results and vision for the future clean assemblies of cavities and cryomodule strings.

43 PARTICLE ACCELERATORS↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY23 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY23. As a continuation of the modeling effort from FY22, this year’s work focuses on improving the RELAP5-3D model developed previously for two-phase flow simulations. The RELAP5-3D model is updated to more accurately capture the heat loss experienced by the facility. The updated model is compared against experimental data for benchmarking purposes of the RELAP5-3D input model. By correctly accounting for heat loss, the updated RELAP5-3D model can now predict the two-phase baseline case more accurately. The onset and the duration of instability are captured well by the model. Furthermore, analyses are performed to better understand the instability mechanism experienced by the flow where the expansion of the boiling boundary in the chimney is studied in details and the fundamental frequencies of the oscillations are obtained. The updated RELAP5-3D model is further compared against four fault conditions, namely the reduction of riser header inlet flow area, depletion of system inventory, blocked riser channels, and static boiling scenario. For each fault condition, minor modifications and tuning are performed to improve the predictions of the model. The purpose of the analyses is to investigate the capability of RELAP5-3D in predicting complex two-phase flows in possible accident scenarios in actual Reactor Cavity Cooling System (RCCS). Overall, the model is able to capture the behaviors and trends of these fault conditions relatively well. Some discrepancies remain between the experimental data and the predictions, many of which are likely due to the differences in the predicted and experimental vapor generation rate. Future work will focus on the continued development of the current RELAP5-3D input model of the NSTF to both improve the accuracy of the model’s predictive capability and continue supporting the experimental program needs. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗