Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Cements and a Modeling Tool to Calculate their Viability under Various Exploitation Conditions of HT RTES Systems

Primary cementing is the most important operation performed on a subterranean reservoir. Cement, placed in the annulus between the casing and the formations serves as a hydraulic seal preventing fluids and gas migrations, protecting steel casing from corrosion and supporting the well structure. Poor cementing jobs can be directly responsible for wells not reaching their full capacity, casing corrosion, compromised well integrity and, in the worst-case scenarios, well collapse.

15 GEOTHERMAL ENERGY↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential Chemical Impacts of Subsurface CO 2 : An Integrated Experimental and Numerical Assessment for a Case Study of the Ogallala Aquifer

Leakage from geologic CO 2 sequestration (GCS) reservoirs to overlying underground sources of drinking water (USDW) is a tangible risk. This study is an integrated assessment that combines column experiments and reactive transport simulations of sediments sampled from the Ogallala aquifer above an active commercial-scale GCS site (the Farnsworth Unit in northern Texas). Experimental and simulation results suggest that carbonate mineral (calcite and dolomite) dissolution is the most significant reaction following CO 2 intrusion, and is also the dominant source of trace metal release. Cation exchange is another key mechanism controlling trace metal release by cation interference. Most of the trace metals, including Ba, Sr, As, Pb, and Zn, show a short-term release and quickly drop to the baseline values, suggesting low risk to the overlying USDW quality. Other trace metals, such as Mn and U, exhibit a tangible increase of their concentrations in the beginning, and drop to a higher level compared to the baseline, which may become a potential concern of long-term USDW quality change with CO2introduction. This study provides a comprehensive example of combining laboratory experiments and simulations for assessment of CO 2 -sediment interactions with combined release mechanisms in shallow groundwater aquifers. Data presented here provides useful insights for quantitative risk assessment and effective public education regarding CO 2 geological sequestration, and trace metal reactive transport studies in shallow groundwater aquifers.

54 ENVIRONMENTAL SCIENCES↗

Epidemiology, Clinical Features, and Outcomes of Coccidioidomycosis, Utah, 2006–2015

On the basis of a 1957 geographic Coccidioides seropositivity survey, 3 counties in southwestern Utah, USA, were considered coccidioidomycosis-endemic, but there has been a paucity of information on the disease burden in Utah since. We report findings from a recent clinical and epidemiologic study of coccidioidomycosis in Utah. To describe clinical characteristics, we identified all coccidioidomycosis cases in an integrated health system in the state during 2006–2015. For epidemiologic analysis, we used cases reported to the Utah Department of Health during 2009–2015. Mean state incidence was 1.83 cases/100,000 population/year. Washington County, in southwestern Utah, had the highest incidence, 17.2 cases/100,000 population/year. In a generalized linear model with time as a fixed effect, mean annual temperature, population, and new construction were associated with regional variations in incidence. Using these variables in a spatiotemporal model, we estimated the adjusted regional variation by county to predict areas where Coccidioides infections might increase.

60 APPLIED LIFE SCIENCES↗

Business Case Analysis for Artificial Intelligence-Large Language Model Technology Integration

AI-assisted processes are expected to enhance operational efficiency and improve decision-making, supporting the long-term economic viability of nuclear power plants. However, detailed business analyses of AI-generated cost savings are rarely performed. Given the recent industry interest in Large Language Model (LLM), the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program has conducted a comprehensive business case analysis of LLM Artificial Intelligence (AI) implementation in nuclear plant engineering workflows. The research employed three complementary business case approaches to evaluate impact of an LLM, using three representative engineering processes as use-cases: Boric Acid Corrosion (BAC) Evaluations, Maintenance Rule Evaluations, and 10 CFR 50.59 Screenings. Through detailed workload analyses and structured interviews, the study quantified significant efficiency improvements ranging from 11% to 59% across these processes. The research further considers how these efficiency gains could translate into tangible reliability improvements through enhanced engineering capacity. Analysis of historical plant trip data indicates that enabling engineers to focus on proactive reliability activities could provide substantial financial benefits through avoided outages, potentially generating greater value than the direct efficiency improvements alone. By documenting successful applications, implementation challenges, and strategic opportunities, this research provides nuclear utilities with a practical framework for evaluating the value of AI technology to support long-term operations through advanced digital technologies.

97 MATHEMATICS AND COMPUTING↗

Eliminating the Derate of Carbon Capture Retrofits (Rev. 2)

This study presents updated cost and performance information on retrofitting pulverized coal (PC) power plants with post-combustion carbon capture based on an advanced solvent process, based on NETL's Fossil Energy Baseline, Revision 4A. Cases considered include those using a fully integrated capture system, a case that provides capture system steam via a natural gas boiler, and a case that provides combined heat and power via a natural gas simple cycle system. Comparison cases include both new build and retrofit analysis at 90% and 95% carbon capture.

20 FOSSIL-FUELED POWER PLANTS↗

Implementation of low-burnup swelling focused assessment case and enhancement of FIPD-BISON integration framework

This report summarizes the activities and achievements made by Argonne National Laboratory for the Nuclear Energy Advanced Modeling and Simulation (NEAMS) BISON code metallic fuel validation and verification (V&V) project in FY2023, with a focus on the capability development and assessment case development for steady state irradiation experiments. The X423 IFR experiment assessment case, which is focused on the evaluation of low burnup swelling behavior of both binary and ternary metallic fuel, has been developed. It covers 58 fuel pins with various fuel compositions and 158 sets of post-irradiation examination (PIE) data with burnup ranging from ~0.5 at.% to ~5.0 at.%, providing a powerful tool within BISON for the calibration, evaluation, verification and validation of both existing and future metallic fuel swelling models at low burnup. Meanwhile, the X447 IFR experiment assessment case established in FY2022 was enhanced to utilize the latest advanced features in BISON, such as automatic differentiation and Mortar contact models. With such enhancements, especially the Mortar mechanical contact model with friction, BISON is now capable of predicting axial fuel growth that is consistent with experimental measurements. Additionally, during the development, gaps and potential scopes were identified and explorative efforts were made, providing insight for future works.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pumped Storage Hydropower Augmented with Pressurized Air: The Ground-Level Integrated Diverse Energy Storage (GLIDES) System — GLIDES System Configurations and Use Cases

Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.

13 HYDRO ENERGY↗

Higher Education Buildings Recognized for Integrated Controls for HVAC and Lighting Systems - Case Study: California State University Dominguez Hills and University of Minnesota

This case study describes connected lighting system projects on two college campuses; Cal State Dominguez Hills and the University of Minnesota both implemented lighting and controls upgrades at mixed-use buildings, including advanced sensors, HVAC integration, and plug load control. Both projects were recognized by DOE's Integrated Lighting Campaign.

integrated lighting, higher education, college, un↗

Evaluation of integrated daylighting and electric lighting design projects: Lessons learned from international case studies

This article presents and discusses the lessons learned from the monitoring of 25 integrated daylighting and electric lighting international case study projects. The case studies consist of real occupied buildings that have been monitored as part of the International Energy Agency (IEA) SHC Task 61/EBC Annex 77 Programme. The general goal of the case studies was to balance lighting energy use with occupants’ visual and non-visual requirements. This was achieved using innovative solutions for daylighting and electric lighting with advanced controls, but also implementing simple and out-of-the-box strategies. The findings suggest that energy demands for lighting can significantly be reduced by combining sensible daylight provision, efficient lighting sources, and advances in controls. Yet, the effective achievement of project goals requires adequate monitoring, fine-tuning, and verification. The findings also suggest that the adoption of “integrative” lighting – that is, lighting systems that address both visual and non-visual responses – is getting increasingly popular. Catering to non-visual requirements will likely drive further innovation in lighting technology. Currently, there is limited investment available for developing daylighting systems for integrative lighting, and the current related electric strategies often come at the risk of energy rebound effects. Overall, providing daylighting and understanding user requirements are fundamental steps towards achieving quality projects, with potential benefits beyond saving energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A short note on the accuracy of the discontinuous Galerkin method with reentrant faces

In this work, we study the convergence of the discontinuous Galerkin (DG) method applied to the advection–reaction equation on meshes with reentrant faces. On such meshes, the upwind numerical flux is not smooth, and so the numerical integration of the resulting face terms can only be expected to be first-order accurate. Despite this inexact integration, we prove that the DG method converges with order $\mathscr{O}$(h p+1/2 ), which is the same rate as in the case of exact integration. Consequently, specialized quadrature rules that accurately integrate the non-smooth numerical fluxes are not required for high-order accuracy. These results are numerically corroborated on examples of linear advection and discrete ordinates transport equations.

97 MATHEMATICS AND COMPUTING↗

Integrated Controls for Plug Loads and Lighting Systems - Case Study: Minnesota DOT Cedar Avenue Truck Station

This case study highlights the strategies the Minnesota Department of Transportation used at Cedar Avenue Truck Station for integrating plug load and lighting systems. An integrated controls pilot project with retrofit installation was conducted from October 2019 to April 2020 and was recognized by DOE's Integrated Lighting Campaign.

integrated lighting, lighting, controls, plug load↗

Development and application of marginal likelihood optimization for integral parameter adjustment

When adjusting nuclear data with integral experiments, care must be taken that spurious adjustments are not made by assimilating poorly characterized integral parameters. If there are unaccounted for biases or poorly estimated uncertainties in the calculated and experimental values for an integral parameter, the Bayesian data assimilation may adjust the nuclear data in a manner that does not reflect the physics of the integral parameter. To identify and lessen the impact of these inconsistent integral parameters, in this study we present a Marginal Likelihood Optimization algorithm. In a data-driven way, the marginalized likelihood is used to modulate hyperparameter terms that decrease the influence of inconsistent integral parameters on the adjustment. The advantage of this approach over other methods in the literature is that it incorporates correlation information and does not remove an integral parameter from the adjustment. Herein, we present and motivate the algorithm, and apply it to an integral data assimilation case study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing a Prototype Methodology to Rank CO2-EOR Wells and Assess Their Reuse Potential for Geologic Carbon Storage

This paper presents a prototype methodology to assess the possible transition of Class II carbon dioxide-enhanced oil recovery (CO2-EOR) wells to Class VI wells. The focus is on wellbore construction materials—casing, cement, tubing, and the packer—and includes comprehensive workflows to evaluate these materials, with primary emphasis on compliance with Environmental Protection Agency (EPA) Class VI well construction and conversion guidelines. These workflows systematically assess material properties and performance criteria to ensure regulatory compliance and optimize long-term wellbore integrity and functionality. Utilizing Python scripts and JavaScript Object Notation (JSON) representations, the study automates checks on digitized Texas Railroad Commission (TRRC) data to rank wells based on workflow criteria. By emphasizing critical factors such as casing integrity, cementing techniques, tubing compatibility, and packer selection, the methodology helps well owners and operators prioritize wells for potential reuse as CO2 injection wells. Given limitations in digitized data, manual user verification is required in some sections. Future improvements include integrating non-digitized data through web scraping and machine learning techniques. This research serves as a practical guide for stakeholders, supporting environmental compliance and sustainable well operations.

geologic carbon sequestration↗