Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary interactions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Shear stabilization of the capillary breakup of a cylindrical interface

A cylindrical interface containing a viscous liquid set into axial motion is subject to a capillary and to a surface-wave instability. Clues from previous studies suggest that, even though both mechanisms separately are destabilizing, under certain circumstances their mutual interaction can lead to a stable interface; shear can stabilize capillary breakup. Here, an axial flow through an annular cross section bounded on the inside by a rigid rod and on the outside by a deformable interface is considered. The competition between the two mechanisms is studied through the temporal growth of infinitesimal axisymmetric and nonaxisymmetric disturbances. This examination of temporal stability shows that, indeed, for geometries corresponding to thin annular layers both instabilities can be completely suppressed (disturbances of all wavelengths decay).

Russo, Mathew J.↗

Dissipative particle dynamics simulations of deformation and aggregation of healthy and diseased red blood cells in a tube flow

In this paper, we report simulation results assessing the deformation and aggregation of mixed healthy and malaria-infected red blood cells (RBCs) in a tube flow. A three dimensional particle model based on Dissipative Particle Dynamics (DPD) is developed to predict the tube flow containing interacting cells. The cells are also modelled by DPD, with a Morse potential to characterize the cell-cell interaction. As validation tests, a single RBC in a tube flow and two RBCs in a static flow are simulated to examine the cell deformation and intercellular interaction, respectively. The study of two cells, one healthy and the other malaria-infected RBCs in a tube flow demonstrates that the malaria-infected RBC (in the leading position along flow direction) has different effects on the healthy RBC (in the trailing position) at the different stage of parasite development or at the different capillary number. With parasitic development, the malaria-infected RBC gradually loses its deformability, and in turn the corresponding trailing healthy RBC also deforms less due to the intercellular interaction. With increasing capillary number, both the healthy and malaria-infected RBCs are likely to undergo an axisymmetric motion. The minimum intercellular distance becomes small enough so that rouleaux is easily formed, i.e., the healthy and malaria-infected RBCs are difficultly disaggregated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft

The Terra spacecraft is the flagship of NASA's Earth Science Enterprise. It provides global data on the state of atmosphere, land and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport System (CPHTS) for temperature control: Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.

Ku, Jentung↗

Capillary barriers for staged loading of microfluidic devices

Various aspects of the present disclosure are directed toward methods and apparatuses for interacting a first liquid and a second liquid in one or more fluidic channels of a capillary structure. The methods and apparatuses can include providing at least one capillary barrier that positions a meniscus of the first liquid at a fluid-interface region using capillary forces within the capillary structure. Additionally, a path is provided along one of the channels for the second liquid to flow toward the fluid-interface region. Additionally, gas pressure is released, via a gas-outflow port, from the fluid-interface region while flow of the first liquid is arrested. Further, the first liquid and the second liquid contact in the fluid-interface region with the capillary barrier holding the first liquid at the fluid-interface region.

Santiago, Juan G.↗

Numerical Simulation of Ion Transport in a Nano-Electrospray Ion Source at Atmospheric Pressure

Understanding ion transport properties from the ion source to the mass spectrometer (MS) is essential for optimizing device performance. Numerical simulation helps in understanding of ion transport properties and, furthermore, facilitates instrument design. In contrast to previously reported numerical studies, ion transport simulations in a continuous injection mode whilst considering realistic space-charge effects have been carried out. The flow field was solved using Reynolds-averaged Navier-Stokes (RANS) equations, and a particle-in-cell (PIC) method was applied to solve a time-dependent electric field with local charge density. A series of ion transport simulations were carried out at different cone gas flow rates, ion source currents, and capillary voltages. A force evaluation analysis reveals that the electric force, the drag force, and the Brownian force are the three dominant forces acting on the ions. Both the experimental and simulation results indicate that cone gas flow rates of ≤250 slph (standard liter per hour) are important for high ion transmission efficiency, as higher cone gas flow rates reduce the ion signal significantly. The simulation results also show that the ion transmission efficiency reduces exponentially with an increased ion source current. Additionally, the ion loss due to space-charge effects has been found to be predominant at a higher ion source current, a lower capillary voltage, and a stronger cone gas counterflow. The interaction of the ion driving force, ion opposing force, and ion dispersion is discussed to illustrate ion transport mechanism in the ion source at atmospheric pressure. .

42 ENGINEERING↗

Interfacial gauge methods for incompressible fluid dynamics

Designing numerical methods for incompressible fluid flow involving moving interfaces, for example, in the computational modeling of bubble dynamics, swimming organisms, or surface waves, presents challenges due to the coupling of interfacial forces with incompressibility constraints. A class of methods, denoted interfacial gauge methods, is introduced for computing solutions to the corresponding incompressible Navier-Stokes equations. These methods use a type of "gauge freedom" to reduce the numerical coupling between fluid velocity, pressure, and interface position, allowing high-order accurate numerical methods to be developed more easily. Making use of an implicit mesh discontinuous Galerkin framework, developed in tandem with this work, high-order results are demonstrated, including surface tension dynamics in which fluid velocity, pressure, and interface geometry are computed with fourth-order spatial accuracy in the maximum norm. Applications are demonstrated with two-phase fluid flow displaying fine-scaled capillary wave dynamics, rigid body fluid-structure interaction, and a fluid-jet free surface flow problem exhibiting vortex shedding induced by a type of Plateau-Rayleigh instability. The developed methods can be generalized to other types of interfacial flow and facilitate precise computation of complex fluid interface phenomena.

42 ENGINEERING↗

Microscopic Motion of Liquid Metal Plasma Facing Components In A Diverted Plasma

Liquid metal plasma facing components (PFCs) have been identified as an alternative material for fusion plasma experiments. The use of a liquid conductor where significant magnetic fields are present is considered risky, with the possibility of macroscopic fluid motion and possible ejection into the plasma core. Analysis is carried out on thermoelectric magnetohydrodynamic (TEMHD) forces caused by temperature gradients in the liquid-container system itself in addition to scrape-off-layer currents interacting with the PFC from a diverted plasma. Capillary effects at the liquid-container interface will be examined which govern droplet ejection criteria. Stability of the interface is determined using linear stability methods. In addition to application to liquidmetal PFCs, thin film liquidmetal effects have application to current and future devices where off-normal events may liquefy portions of the first wall and other plasma facing components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of human endothelial cells and nickel-titanium materials modified with silicon ions

The paper studies the influence of chemical and phase compositions of NiTi surface layers modified with Si ions by plasma immersion implantation on their interaction with endothelial cells. It is shown that certain technological modes of Si ion implantation enhance the adhesion, proliferation, and viability of endothelial cells. It is found that the Si-modified NiTi surface is capable of stimulating the formation of capillary-like structures in the cell culture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design for an Integrated Open-Loop System for Carbon Dioxide Removal using Liquid Amine

Manned Space missions require maintaining a safe environment for the crew that can both sustain a breathable atmosphere and remove pollutants. Carbon dioxide, while not toxic in low concentrations, accumulates as crew members work and breath and can eventually affect the crew’s health. Therefore, a constant, passive system to remove the carbon dioxide build up is necessary for long-term missions. Currently, the prevailing liquid sorbent used in submarines and industrial flue gas utilizes the primary amine, monoethanolamine (MEA), to capture, transfer, and remove carbon dioxide from air. Diglycolamine (DGA) is an alternate primary amine that has similar performance and less volatility. It is currently being studied at Ames Research Center (ARC) and is the primary candidate for the operation of the sub-scale liquid amine test stand. The test stand is used to investigate liquid flow and liquid gas interfaces to assist in a system design for microgravity applications. The test stand includes a wedge design utilizes capillary action to hold the liquid while allowing gas-liquid interaction for carbon dioxide transfer. These wedge trays are placed in a contactor unit to remove carbon dioxide from the air stream, a degasser unit to replenish the liquid amine, and a capillary condensing heat exchanger (CCHX) to recapture water lost in the degasser unit. Nominal operating conditions for the contactor are a gas flow rate of 26scfm enriched with pure CO2 to 2600ppm and a liquid mixture of 65/35 vol% DGA/H2O at 0.65mL/min while the degasser was operated at 100°C and 1 atm. This paper discusses the challenges and limitations of a fully integrated system which will influence the design of a new subscale test stand.

Adrian Cortez↗

Viewpoint 9--molecular structure of aqueous interfaces

In this review we summarize recent progress in our understanding of the structure of aqueous interfaces emerging from molecular level computer simulations. It is emphasized that the presence of the interface induces specific structural effects which, in turn, influence a wide variety of phenomena occurring near the phase boundaries. At the liquid-vapor interface, the most probable orientations of a water molecule is such that its dipole moment lies parallel to the interface, one O-H bond points toward the vapor and the other O-H bond is directed toward the liquid. The orientational distributions are broad and slightly asymmetric, resulting in an excess dipole moment pointing toward the liquid. These structural preferences persist at interfaces between water and nonpolar liquids, indicating that the interactions between the two liquids in contact are weak. It was found that liquid-liquid interfaces are locally sharp but broadened by capillary waves. One consequence of anisotropic orientations of interfacial water molecules is asymmetric interactions, with respect to the sign of the charge, of ions with the water surface. It was found that even very close to the surface ions retain their hydration shells. New features of aqueous interfaces have been revealed in studies of water-membrane and water-monolayer systems. In particular, water molecules are strongly oriented by the polar head groups of the amphiphilic phase, and they penetrate the hydrophilic head-group region, but not the hydrophobic core. At infinite dilution near interfaces, amphiphilic molecules exhibit behavior different from that in the gas phase or in bulk water. This result sheds new light on the nature of hydrophobic effect in the interfacial regions. The presence of interfaces was also shown to affect both equilibrium and dynamic components of rates of chemical reactions. Applications of continuum models to interfacial problems have been, so far, unsuccessful. This, again, underscores the importance of molecular-level information about interfaces.

Review, Tutorial↗

Molecular Alignment of a Meta-Aramid on Carbon Nanotubes by In Situ Interfacial Polymerization

Molecularly organized nanocomposites of polymers and carbon nanotubes (CNTs) have great promise as high-performance materials; in particular, conformal deposition of polymers can control interfacial properties for mechanical load transfer, electrical or thermal transport, or electro/chemical transduction. However, controllability of polymer-CNT interaction remains a challenge with common processing methods that combine CNTs and polymers in melt or in solution, often leading to nonuniform polymer distribution and CNT aggregation. In this work, we demonstrate CNTs within net-shape sheets can be controllably coated with a conformal coating of meta-aramid by simultaneous capillary infiltration and interfacial polymerization. We determine that π-interaction between the polymer and CNTs results in chain alignment parallel to the CNT outer wall. Subsequent nucleation and growth of the precipitated aramid forms a smooth continuous layered sheath around the CNTs. These findings motivate future investigation of mechanical properties of the resulting composites, and adaptation of the in situ polymerization method to other substrates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Guiding and Ionization Blueshift in Ablative Capillary Waveguide Accelerators

Laser wakefield acceleration (LWFA) in plasmas has been demonstrated with gradients which are orders of magnitude greater than the limit on conventional Radio Frequency accelerators. However, the acceleration length is limited by two factors, the dephasing length and the Rayleigh range of the laser pulse. Dephasing length is the distance in which electrons overtake the laser pulse and can be increased by decreasing plasma density. Alternatively the interaction length can be extended by orders of magnitude by using ablative wall discharge capillary targets, in which a plasma is preformed with a transverse density profile capable of guiding the focused laser. We have demonstrated guiding of high intensity laser pulses from the HERCULES laser over 3 cm for powers up to 35 TW. The quality of the laser spot can be retained and the intensity remains high even at the exit of the capillary. The transmitted laser spectrum shows blueshifting due to field ionization by the laser pulse. This ionization might enhance electron injection at low electron density for LWFA GeV accelerators. The field ionization affects carbon atoms and ions from the ablated capillary, which are not present in hydrogen-filled capillaries. This creates an additional challenge to guiding compared to hydrogen-filled capillaries. However, the setup and materials are easier to come by. The use of these capillary targets may also be of interest to other high intensity laser-plasma interactions requiring long interaction lengths such as high harmonic generation from gases and plasmas, or x-ray lasing in underdense plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Abstract - Cooperative Research and Development Agreement between Oxergy, Inc. and National Energy Technology Laboratory

The Raman Gas Analyzer (RGA) has been demonstrated to have an extremely fast response (<1 second), pressurized, multi-gas analysis capability. All but the noble gases are Raman active, although the Raman interaction is weak. The RGA uses a reflectively lined capillary as the optical cell, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations.

47 OTHER INSTRUMENTATION↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Oxergy, Inc.

The NETL Raman Gas Analyzer (RGA) has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, although the Raman interaction is weak. The RGA uses a reflectively lined capillary as the optical cell, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (carbon monoxide, carbon dioxide, nitrogen, oxygen, and water). This provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process – including improved fuel flexibility and efficiency for power generation systems. Research and development up to 2016 resulted in the construction of two field prototypes of the NETL RGA, which has been in applied to various laboratory applications for testing. The results of the testing have been used to improve the RGA design, with the intent to support technology transfer. The quality of the optical capillary used in the RGA is critical to its performance, and prior work at NETL produced a few optical capillaries superior to those commercially available. The production of high optical quality capillaries, however, was inconsistent in its results. With the support of the DOE Office of Technology Transitions, through the Technology Commercialization Fund program, this project was undertaken to address this commercialization barrier and to also evaluate the possible application of Raman gas analysis to a supercritical water gasification process being developed by Oxergy Inc. Oxergy, a small business located in Fairbanks, Alaska, is developing ultra-compact thermochemical reaction devices built with advanced manufacturing processes. Chief Technology Officer Jonathan Kamler holds the (pending) patent to Oxergy’s core reactor technology. Oxergy maintains wet-lab and combustion-lab space at the University of Alaska Fairbanks Center for Sustainable Living in Palmer, Alaska, where Mr. Kamler operates a pilot-scale, supercritical water gasification system designed and built by Oxergy. Mr. Kamler also operates an All Powers Labs Power Pallet gasifier coupled to a 10KW electrical generator as a dry biomass test platform at the Palmer facility. Both systems are suitable for real-world, collaborative testing of Raman gas analysis applications. The objectives of the CRADA include making the production of high-quality optical capillaries consistent and high yield, investigating other options for optical waveguides, and testing the capillaries for measurements in supercritical water gasification. Success on these objectives will support commercialization of both the RGA and supercritical water gasification technologies. Through the work performed on this project, a new apparatus was constructed and optimized to provide consistent production of high-quality optical capillaries. Several thick-walled capillaries were coated using this apparatus and shipped to Oxergy in September 2018 for testing in both dry gasification and supercritical water gasification process monitoring applications at University of Alaska Fairbanks facilities in Palmer. The strong earthquake near Anchorage and Palmer in November 2018 caused extensive damage and closure of the facilities used by Oxergy, preventing Oxergy from proceeding with experimental testing before the end of the project; the facility has been closed indefinitely. Earthquake damage prohibited the completion of all the project objectives prior to the end of the project. However, significant progress was made toward addressing a core technology commercialization barrier. The largest and most mature potential market for Raman gas analysis is its use in analytical instruments, which require sensitivity and low detection limits, and Oxergy’s market research found that market inertia is a barrier to commercial success in this market. Although NETL’s innovations in capillary coating have substantially improved Raman gas analysis capability, the likely market is expected to be niche applications that value the fast detection of real-time changes in gas composition.

Chorpening, Benjamin↗

Capillary, wettability and interfacial dynamics in polymer electrolyte fuel cells

In the present scenario of a global initiative toward a sustainable energy future, the polymer electrolyte fuel cell (PEFC) has emerged as one of the most promising alternative energy conversion devices for different applications. Despite tremendous progress in recent years, a pivotal performance/durability limitation in the PEFC arises from liquid water transport, perceived as the Holy Grail in PEFC operation. The porous catalyst layer (CL), fibrous gas diffusion layer (GDL) and flow channels play a crucial role in the overall PEFC performance due to the transport limitation in the presence of liquid water and flooding phenomena. Although significant research, both theoretical and experimental, has been performed, there is serious paucity of fundamental understanding regarding the underlying structure-transport-performance interplay in the PEFC. The inherent complex morphologies, micro-scale transport physics involving coupled multiphase, multicomponent, electrochemically reactive phenomena and interfacial interactions in the constituent components pose a formidable challenge. In this paper, the impact of capillary transport, wetting characteristics and interfacial dynamics on liquid water transport is presented based on a comprehensive mesoscopic modeling framework with the objective to gain insight into the underlying electrodynamics, two-phase dynamics and the intricate structure-transport-interface interactions in the PEFC.

08 HYDROGEN↗

Wetting of prototypical one- and two-dimensional systems: Thermodynamics and density functional theory

Consider a two-dimensional capped capillary pore formed by capping two parallel planar walls with a third wall orthogonal to the two planar walls. This system reduces to a slit pore sufficiently far from the capping wall and to a single planar wall when the side walls are far apart. Not surprisingly, wetting of capped capillaries is related to wetting of slit pores and planar walls. For example, the wetting temperature of the capped capillary provides the boundary between first-order and continuous transitions to condensation. We present a numerical investigation of adsorption in capped capillaries of mesoscopic widths based on density functional theory. The fluid-fluid and fluid-substrate interactions are given by the pairwise Lennard-Jones potential. We also perform a parametric study of wetting in capped capillaries by a liquid phase by varying the applied chemical potential, temperature, and pore width. This allows us to construct surface phase diagrams and investigate the complicated interplay of wetting mechanisms specific to each system, in particular, the dependence of capillary wetting temperature on the pore width.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling nuclear waste disposal in crystalline rocks at the Forsmark and Olkiluoto repository sites – Evaluation of potential thermal–mechanical damage to repository excavations

We conduct coupled thermo-hydro-mechanical modeling of a KBS-3V repository design in crystalline rocks, using data and conditions from the Forsmark in Olkiluoto repository sites in Sweden and Finland. The study focuses on repository performance related to the impact of thermal and hydraulic evolution on the potential for thermal–mechanical damage to underground repository excavations. For the designs and conditions considered at the Forsmark and Olkiluoto repository sites, the simulations show a peak temperature well under the adopted performance target of a 100°C maximum temperature, whereas there is still a high potential for thermal–mechanical damage to the KBS-3V waste deposition holes. The thermal–mechanical damage is much more likely if rock permeability is so low that it delays saturation and swelling of bentonite-clay-based backfill beyond the time for the thermal–mechanical peak, which occurs 50 to 100 years after nuclear waste deposition. We also found that sidewalls of the KBS-3V emplacement tunnels are vulnerable to tensile fracturing due to the combined effect of thermal stressing and backfill swelling. The study highlights a strong interaction between bentonite-based backfill and host rock through capillary suction along with induced rock desaturation. A careful design and selection of the bentonite-clay-based backfill materials for KBS-3V tunnels and deposition holes can facilitate a timely saturation and backfill swelling that in turn can minimize thermal–mechanical damage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗