Exploring Novel Configuration Designs Alternatives for Lazy Wave Submarine Power Cables

Floating offshore wind turbines require a complex integrated design to balance the platform response and station-keeping requirements in a highly dynamic environment. Dynamic subsea power cables are one of the critical components that have to be considered in detail to ensure both extreme, as well as repeated operational conditions do not exceed the cable design limits. This paper presents the design feasibility limits of a 66kV dynamic cable for a lazy wave configuration. The work explores an innovative staggered cable configuration that has the potential to provide additional compliance in shallow water conditions. Both configurations are evaluated using the motions of a representative floating wind platform under development for deployment in relatively shallow water depth of 150m. The assessment was conducted using the hydrodynamic software Orcaflex, incorporating a range of design inputs and design variations. Key parameters analysed include cable curvature and effective tension and bending stress. The alternative cable configuration provides a more gradual crossing of the water column, which would allow to support increased platform excursions in shallow water depths. The design uses a combined buoyancy and bend protection element, offering designers additional options for challenging operational conditions. The paper will be of interest to designers and developers of floating wind projects, providing a comparative assessment between the conventional lazy wave configuration and an innovative alternative that enables larger cable and mooring excursion envelopes in challenging conditions.

16 TIDAL AND WAVE POWER↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stabilizing dynamic subsea power cables using Bi-stable nonlinear energy sinks

This study investigates vibration mitigation of dynamic subsea cables through passive bi-stable nonlinear energy sinks (B-NESs). These devices suppress vibration energy in a broadband way, and can be regarded as extensions of classical linear tuned mass dampers (TMDs) which are narrowband devices. Through the open-source MoorDyn library, we simulated the vibrations of a vertical subsea cable equipped with a set of B-NESs. Multi-objective optimization was performed to detect the B-NES parameters for optimal mitigation of the cable vibrations. Advanced signal processing verified the efficacy of the optimized B-NESs not only to rapidly absorb and locally dissipate vibration energy, but also to nonlinearly scatter vibration energy from low to high frequencies within the cable itself. This last feature is especially beneficial for vibration mitigation of the undersea cable, as at higher frequencies the cable vibrations exhibit drastically reduced amplitudes and are more effectively dissipated by inherent structural damping and hydrodynamic radiation damping. This contrasts with traditional TMDs which can mitigate vibration only at a single frequency. Furthermore, our robustness study confirms the B-NES's effectiveness under even varying environmental conditions. Overall, the B-NES's capacity for broadband vibration mitigation renders it a promising retrofit solution for improving the performance and operational safety of dynamic power cables in offshore wind farms and other marine applications.

17 WIND ENERGY↗

Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test of Superconducting Wires and Rutherford Cables With High Specific Heat

High-field accelerator magnets made of state-of-the-art Nb 3 Sn Rutherford cables demonstrate relatively long trainings due to sudden heat depositions originated by thermo-mechanical perturbations in the magnet coils. Coil sensitivity to these perturbations can be reduced by increasing the specific heat, Cp, of major coil components - strands, or whole cable, or epoxy. The R&D on all these three approaches is in progress. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using a thin composite Cu/Gd 2 O 3 tape. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. In this work, Cu/Gd 2 O 3 ribbons with ~30% of Gd 2 O 3 powder and two different thicknesses were produced by Hyper Tech Research, Inc. Wire and cable samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for the Minimum Quench Energy (MQE). At 80%Ic, the MQE gain average over the tested magnetic field range of the NbTi cable with high-Cp tape on both sides was ~1.3. The MQE gain average of the NbTi wire wrapped with the high-Cp ribbon was 3.1.

43 PARTICLE ACCELERATORS↗

Ultra-low radioactivity flexible printed cables

Abstract Flexible printed cables and circuitry based on copper-polyimide materials are widely used in experiments looking for rare events due to their unique electrical and mechanical characteristics. However, past studies have found copper-polyimide flexible cables to contain 400-4700 pg 238 U/g, 16-3700 pg 232 Th/g, and 170-2100 ng nat K/g, which can be a significant source of radioactive background for many current and next-generation ultralow background detectors. This study presents a comprehensive investigation into the fabrication process of copper-polyimide flexible cables and the development of custom low radioactivity cables for use in rare-event physics applications. A methodical step-by-step approach was developed and informed by ultrasensitive assay to determine the radiopurity in the starting materials and identify the contaminating production steps in the cable fabrication process. Radiopure material alternatives were identified, and cleaner production processes and treatments were developed to significantly reduce the imparted contamination. Through the newly developed radiopure fabrication process, fully-functioning cables were produced with radiocontaminant concentrations of 20-31 pg 238 U/g, 12-13 pg 232 Th/g, and 40-550 ng nat K/g, which is significantly cleaner than cables from previous work and sufficiently radiopure for current and next-generation detectors. This approach, employing witness samples to investigate each step of the fabrication process, can hopefully serve as a template for investigating radiocontaminants in other material production processes.

36 MATERIALS SCIENCE↗

Consideration of Decabromodiphenyl Ether Flame Retardant in Thermal and Radiation Aging of Crosslinked Polyethylene Cable Insulation

Decabromodiphenyl ether (decaBDE) has been used as a flame-retardant additive in nuclear-grade electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. On January 6, 2021, the Environmental Protection Agency (EPA) published a final rule to phase out decaBDE. The 2021 rule set a two-year compliance deadline for “processing and distribution in commerce of decaBDE for use in wire and cable insulation in nuclear power generation facilities.” In recognition of industry concerns following a sudden discontinuation of decaBDE-containing Class 1E wire and cable essential for nuclear power operations and the time needed for qualifying the individual components using the alternative insulation technology, an extended compliance deadline was set in the finalized amendments to the 2021 rule as published by the Environmental Appeals Board on November 12, 2024. The 2024 rule set the compliance deadline for processing and distributing decaBDE-containing wire and cable insulation until the end of the service life of these materials. Since decaBDE has long been relied upon as the flame retardant in one of the most common cross-linked polyethylene (XLPE) nuclear cable insulation formulations, RSCC Firewall III insulation, questions have naturally arisen regarding whether changes in cable performance might be expected for XLPE containing a decaBDE alternative, especially for safety-related cables that must perform their safety function in a design basis event such as a loss of coolant accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of potential impact of magnetic fields from a subsea high-voltage DC power cable on migrating green sturgeon, Acipenser medirostris

Abstract Empirical evidence suggests that marine animals perceive and orient to local distortions in the earth’s natural magnetic field. Magnetic fields (MFs) generated by electrified underwater cables may produce similar local distortions in the earth’s main field. Concern exists that these distortions may impact migration movements of MF-sensitive animals. The Trans Bay Cable (TBC) is a ± 200-kV, 400-megawatt, 85-km high-voltage direct current transmission line buried through San Francisco Bay (37° 56′ 8.81″ N, 122° 27′ 0.19″ W). Detections of adult green sturgeon implanted with acoustic transmitters were used from six cross-bay receiver arrays from 2006 to 2015 to investigate how inbound and outbound migration movements through lower portions of their route to/from upstream breeding grounds are related to the TBC’s energization status (off/on) and other local environmental variables. Here, we assess how these variables impacted transit success, misdirection from the migration route, transit times, and migration path locations within stretches between the Bay’s mouth and the start of the Sacramento River. Overall, there was varied evidence for any effect on migration behavior associated with cable status (off/on). A higher percentage of inbound fish successfully transited after the cable was energized, but this effect was nonsignificant in models including temperature. Outbound fish took longer to transit after cable energization. Inbound and outbound migration path locations were not significantly influenced by cable energization, but results suggest a potential subtle relationship between energization and both inbound and outbound paths. Overall, additional migration-based studies are needed to investigate the impact of anthropogenic cables on marine species.

Wyman, Megan T. (ORCID:0000000256844603)↗

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING↗

Systems and methods for assessing cable insulation

Methods for assessing cable insulation are provided that can include engaging a first tine gap interdigital capacitor assembly with the exterior of the cable jacket to determine a first capacitance and dissipation factor value of the insulation using the first tine gap interdigital capacitor assembly; engaging a second tine gap interdigital capacitor assembly with the exterior of the cable jacket to determine a second capacitance and dissipation factor value of the insulation using the second tine gap interdigital capacitor assembly.Systems for assessing cable insulation are also provided. The systems can include a cable jacket encompassing cable insulation and conductive material; at least two tine gap interdigital capacitor assemblies engaged with the cable jacket; and processing circuitry operatively engaged with the capacitor assemblies.

Glass, III, Samuel W.↗

First Phase Consensus Roadmap for Development of Condition-Based Cable Reliability Assurance

The objective of this work was to develop a first phase consensus roadmap for condition-based qualification (CBQ) of electrical cables. With CBQ, qualification of Class 1E electrical cables moves from a time-based approach to a condition-based approach, which is anticipated to be safer in terms of reliability and conservatism, and more cost effective in the long run. However, due to barriers, the CBQ approach has not yet been adopted by U.S. nuclear power plants (NPPs). Based upon a review of current work evaluating CBQ, the limitation of available condition monitoring technology seems to be the largest barrier. The importance of condition monitoring, or more specifically selecting appropriate condition indicators, during CBQ cannot be understated. However, selecting appropriate condition indicators is challenged by techniques that are destructive and only evaluate cable degradation locally. Further, arguably, no one identified condition indicator fully establishes cable condition. Thus, additional work is necessary to evaluate potential condition indicators towards CBQ. In addition to the requirements of IEC/IEEE Std. 60780-323, ideal condition indicators should include a) both destructive and non-destructive approaches, b) both local and global measurements, c) real-time (i.e., online) monitoring that trends with degradation, d) enable correlation with qualified levels of degradation, and e) be established within a repository of condition indicators with applicable materials and/or components and their acceptance criteria. Additional work is needed in development of technology and methodology prior to adoption of CBQ, especially for extending qualified life of installed components. Education and early experience by the industry and regulators will be required for this change in approach as an alternative to re-analysis. A series of workshops that bring together stakeholders to identify and address gaps will be needed. The longstanding cooperative working group of cable researchers from the U.S. Department of Energy, the Electric Power Research Institute, and the Nuclear Regulatory Commission forms a valuable starting point for development of a consensus roadmap to condition-based qualification approach as a viable options for qualification of cable systems in U.S. light water reactors.

42 ENGINEERING↗

Phase Drifts and Signal Dispersion in Coaxial Cables

Phase reference distribution is a critical challenge in modern linear particle accelerators, such as European Spallation Source (ESS), European X-ray Free Electron Laser (E-XFEL), or Proton Improvement Plan II (PIP-II). Similar issues may also arise in other RF systems that need to synchronize many independent circuits. Achieving low phase drift of the reference signal requires careful selection of cables and their environmental operating conditions. Due to the limited data provided by cable manufacturers, it is necessary to characterize the cable performance. This article investigates the phase drifts in coaxial cables and presents a dedicated measurement methodology. The dispersion characteristics of the cables are also examined. The measurement results of various coaxial cables are presented, along with conclusions and practical guidelines for designers of phase reference distribution lines.

coaxial cables↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

A Reconfigurable Planar Capacitor Sensor for Thru the Jacket Dielectric Constant Measurement of Cable Insulation

Planar capacitor sensors have been proposed to measure the aging-related dielectric constant variation of the jacket or insulation materials of cables. Although capacitor sensors have been used to monitor the aging of cable insulation by removing the jacket, through the jacket measurement of cable insulation dielectric constant variation is difficult because once the sensor is placed on the jacket it would either measure the aging of the jacket or that of the jacket and insulation together. A reconfigurable sensor along with innovative cable-specific models could be used to determine the jacket and insulation aging using the same sensor. For the proposed novel reconfigurable sensor, the electric field penetration depth is changed by activating and deactivating PIN diode switches. In one instance, the sensor measures the dielectric constant variation of the jacket, while in the next, it measures the dielectric constant variation of both the jacket and the insulation. Here, by leveraging previously developed capacitance estimation models from large-scale finite element simulations for a specific cable, these two sets of measurement data are used to evaluate the aging-related dielectric constant variation of the insulation. Experimental data from aged cable specimens are presented to demonstrate the operation of the sensor.

47 OTHER INSTRUMENTATION↗

Evaluation of Copper Catalytic Effects in Cable Insulation Polymers

This paper summarizes work performed to evaluate a phenomenon that occurs in electrical cable insulation polymers subjected to accelerated aging while in contact with copper metal. This effect, commonly known as the copper catalytic effect, is a result of chemical reactions that occur when copper ions diffuse into insulation polymers. This diffusion process is observed in various types of polymeric materials exposed to elevated temperatures and happens at the interface between the insulation and metallic components (e.g., conductor, shielding, etc.) in a cable. This polymer-metal interaction has only been observed in cables constructed with copper components (i.e., no interactions observed in cables with aluminum or other metal conductor/shielding) and results in a significant catalytic effect that increases the oxidation rate (e.g., aging) of the material. Under this research, the copper catalytic effects observed in cross-linked polyethylene, cross-linked polyolefin and ethylene propylene rubber insulated cables subjected to thermal accelerated aging were evaluated. These evaluations involved applying infrared spectroscopy, microscopy, and energy dispersive X-ray spectroscopy cross-sectional depth profiling to obtain an in-depth understanding of the aging characteristics of the materials under accelerated conditions. Based on the results of these assessments, the copper catalytic effect can have a significant impact on the mechanical, thermal, chemical, and electrical properties of cable insulation polymers. Here, the results acquired from this research provided the information needed to characterize the copper catalytic effects observed in these polymers, analyze how this phenomenon affected the polymer degradation process, and compare and understand the differences in the properties of the materials.

42 ENGINEERING↗

Interdigital Capacitance Sensor for Cable Insulation Test and Monitoring

A substantial body of work suggests feasibility to measure cable jacket and insulation conditions using various forms of interdigital capacitance (IDC) sensors. The sensors can either be used to manually test local cable conditions or as permanently installed sensors. Eligible cables subject to these measurements do not include shielded cables but the set of candidate cables is expanded from only unjacketed cables by the ability to assess insulation condition through the jacket. Dual gap IDC sensors are confirmed to be able to sense the insulation condition beneath a polymer jacket and, moreover, the IDC is the only known way to assess the insulation condition through the jacket. PNNL has filed a patent for this approach and is exploring commercial partnerships to exploit IDC technology for actionable field measurements.

NDE, cable, IDC, capacitance, permittivity, insula↗