Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

National Park Service Bus Electrification Study: 2020 Report

This report summarizes important considerations for implementing BEBs in the three national park fleets, detailing information about current buses at each fleet, electric bus demonstration vehicles, as well as performance evaluations of BEBs in Zion, Bryce, and Yosemite. Results include in-use data collection results reporting metrics such as average bus speed, energy usage per trip, and daily distance traveled, as well as effects of high heating, ventilation, and air conditioning (HVAC) system use to both heat and cool the buses, emissions estimations before and after use of electric buses, operating costs, electric vehicle infrastructure, maintenance, and bus driver user experience survey information. Analysis results from this project will help the NPS understand how BEBs and future expansion of BEBs could assist in meeting their bottom line and operational goals and assist NPS in choosing appropriate locations for future BEB deployments.

33 ADVANCED PROPULSION SYSTEMS↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Zero-Emission Transit Bus Needs Assessment

The transition to zero-emissions vehicles (ZEVs) in public transit has gained traction due to significant federal investments from the Bipartisan Infrastructure Law (BIL) and the Inflation Reduction Act (IRA). This needs assessment, commissioned by the Joint Office of Energy and Transportation and conducted by researchers at the Idaho National Laboratory, explores the current state of electrification in transit agencies, identifying barriers to implementation, potential funding sources, and operational considerations necessary for a successful transition. The assessment involved qualitative interviews with representatives from 19 transit service providers across diverse geographic regions. Key findings highlight the challenges related to bus facilities and operations, which require careful planning for charging infrastructure and maintenance capabilities to accommodate battery electric buses (BEBs) and hydrogen fuel cell buses (HFCBs). Agencies reported operational hurdles due to the shorter range of BEBs compared to diesel buses, necessitating revised scheduling and routing strategies. Despite these challenges, many agencies expressed optimism about their capacity to adapt. Funding availability emerged as a critical factor influencing the transition to ZEVs. While agencies welcomed increased financial support, particularly from the Low or No Emission Grant Program (Lo-No), concerns about the sustainability of this funding and the ongoing operational costs were prevalent. The need for a comprehensive funding inventory was underscored to ensure transit agencies are aware of all available resources. Technological constraints were significant barriers to ZEV adoption. The limited range of BEBs was frequently cited as a concern, leading to operational challenges and reliability issues. Agencies reported difficulties in sourcing replacement parts, which exacerbated downtime and maintenance challenges. Workforce development and training were identified as pivotal for a successful transition. Many agencies rely heavily on manufacturers for technician training, highlighting the need for scalable training programs that equip staff with the necessary skills to maintain electric powertrains effectively. This assessment offers actionable recommendations for the Joint Office, including enhancing outreach to transit agencies, developing resources for effective utility partnerships, and facilitating comprehensive training programs. Establishing a zero-emission bus evaluation program to track performance metrics such as cost, range, and reliability could provide valuable insights for transit agencies. The needs assessment provides a detailed examination of the challenges and opportunities facing transit agencies in their transition to zero-emissions bus fleets. By addressing these issues through targeted support, stakeholders can collaboratively work towards a cleaner, more sustainable public transportation system that benefits all communities.

33 - ADVANCED PROPULSION SYSTEMS↗

A novel method for co-optimizing battery sizing and charging strategy of battery electric bus fleets: An application to the city of Paris

Battery-electric buses (BEBs) are a promising technology for replacing diesel buses and reducing their environmental burden. However, their charging process can take several hours, depending on the charging technique and strategy, making them susceptible to schedule disruptions. Furthermore, the selection of the charging strategy and battery size can increase the total capital investment and operational expenses of a BEB fleet, which is a major obstacle to its adoption. Therefore, to minimize the total cost of ownership (TCO) and prevent schedule disruptions, it is essential to establish a well-defined approach to determine an appropriate battery size and charging strategy for BEB fleets. This paper presents a method for reducing the TCO of BEB by determining the optimal battery size and charging strategy for each bus while satisfying operating constraints. The method involves a two-step optimization algorithm that uses Dynamic Programming and Genetic Algorithm. Further, the study applies this approach to the bus fleet serving line 21 in Paris and generates the optimal battery sizing, charging strategy, and required charging infrastructure. The results indicate that 100 kWh batteries offer the best trade-off between capital and operational expenditure for the fleet deployment if used with 65–85 kW chargers at bus terminals.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated charging infrastructure planning and charging scheduling for battery electric bus systems

We report studies on the electric bus system planning problem have typically focused exclusively on either the deployment of charging infrastructure or the scheduling of charging events; few have examined the impact of charging facility deployment on charging activities. Considering the interdependence of system design and operational strategies, this study proposes a two-phase optimization framework for charging infrastructure planning and charging scheduling for battery electric bus systems. An integrated optimization model is first developed to simultaneously optimize charger deployment, on-board battery capacity, and charging schedules. A charging scheduling model is further proposed and a rolling horizon approach is utilized in the second phase to optimize the real-time charging scheduling of electric buses. Compared to existing electric bus system planning methods, the proposed integrated model can reduce the total system cost by 19.5%. In addition, compared to uncontrolled charging, the proposed rolling horizon-based charging strategy can reduce the total charging cost by 68.3%.

25 ENERGY STORAGE↗

Dynamic Model of Active Front-End Converters with 2DOF-PI Controllers for DC Bus Voltage Control

In most of the research, a conventional one degree-of-freedom type proportional-integral controller (1DOF-PI) is used for the regulation of the dc bus voltage in an Active Front-End Converter (AFEC). This paper proposes a two degree-of-freedom type proportional-integral controller (2DOF-PI) for the regulation of dc bus voltage in an AFEC. Such a controller eliminates the left-half plane (LHP) zero in the command-to-output transfer function for dc bus voltage regulation that is inherent to the conventional 1DOF-PI for this application. The dynamic model of an AFEC in the synchronous reference frame (SRF) is presented. An inner current control and outer dc voltage control loop is built for controlling the AFEC. Vector-control scheme is employed to achieve decoupled control of direct-axis and quadrature-axis currents. The outer dc voltage control loop is designed with a 2DOF-PI to complete the control system. Transfer function (TF) of the controller is derived based on the presented model and used to calculate the controller gains. Transient and steady state performance of the designed controllers are investigated in MATLAB/Simulink and results presented.

Thapa, Anup↗

Dataset of U.S. School Bus Depots

A large body of public health literature describes how undesirable or dangerous facilities, such as truck depots and industrial plants, located in or near communities can lead to health harms. Research also describes the high levels of traffic-related air and noise pollution that is linked to health harms and may be disproportionately distributed near many schools. Therefore, a primary use case for this dataset is to analyze the location of school bus depots and to create an evidence base that would better enable the work of community members, advocates, and other stakeholders toward improving air quality and public health. Other possible uses for this school bus depot dataset include electricity grid planning and reliability, given recent momentum toward school bus electrification. This dataset was created using an object-based approach with remote sensing data. The primary source of aerial imagery was the National Agriculture Imagery Program (NAIP) dataset. NAIP imagery was analyzed to locate individual school buses based on their color and size, and then classified clusters of school buses as potential depots, which were then verified visually. The resulting dataset contains 11,309 depots across the 48 contiguous U.S. states and Washington, D.C. Fifty-one percent (5,730 depots) are at schools, defined as being 350 meters or less from the nearest school. The accuracy of the dataset was assessed by comparing it with independent reference datasets containing 506 depots from the records of two school transportation companies. We found good agreement, with an omission error rate of 15.2% (77 depots). This dataset represents one of the only remote sensing projects to conduct object detection using data at the sub-meter to 1-meter resolution for a continental-scale application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Analysis of the Bus Bars for the 800MeV Injection Era (Fermilab Summer School 2023)

My internship at IARC has been focused on the thermal analysis of the bus bars of the Booster. The bus bars are the conductors that bring the bias current from the bias supply to the ferrite tuners in each RF cavity of the synchrotron. Since they are not superconductors, during normal operations they will heat up due to the Joule effect. The goal of my work is to build a model of the bus bars assembly that describes effectively the experimental data and that can be used to predict the temperature increase and distribution among the components of the assembly, in present and future operational conditions.

43 PARTICLE ACCELERATORS↗

Apollo 14 mission: Inability to disconnect main bus A

During entry, the Apollo 14 spacecraft busses should have de-energized when the main bus-tie motor switches were switched to the off position. One motor switch did not transfer and main bus A remained energized until the battery bus-tie circuit breakers were opened after landing. Analysis revealed that residual catalyst caused the terminal pin seals to revert to a gummy state. Resulting reversion products then migrated to the motor commutator and caused brush degradation, increased and erratic commutator resistance, and reduced motor torque. The motor stalled when available motor torque was reduced below that required to drive through the maximum torque point of the switch.

Source record↗

A study of multiplex data bus techniques for the space shuttle

A comprehensive technology base for the design of a multiplexed data bus subsystem is provided. Extensive analyses, both analytical and empirical, were performed. Subjects covered are classified under the following headings: requirements identification and analysis; transmission media studies; signal design and detection studies; synchronization, timing, and control studies; user-subsystem interface studies; operational reliability analyses; design of candidate data bus configurations; and evaluation of candidate data bus designs.

Kearney, R. J.↗

Design of the HEAO main bus shunt regulator

The High Energy Astronomy Observatory (HEAO) is being built for NASA by an American company. The general requirements concerning the HEAO main bus regulator are examined. The bus regulated voltage is 33 V, the maximum shunt current is 45 A, and the regulator output impedance is to be less than 0.5 Ohm from dc to 100 kHz. Loop gain design considerations for the main bus regulator are discussed and a description is given of the general device configuration. Attention is also given to regulator loop design and performance.

Middlebrook, R. D.↗

The NASA bus communications listening device software

The development of the bus listener is presented. Special software was developed to control the 'bus interface units' (BIU) connecting each of these devices to a communications cable to form the bus communication network. The code used in the BTU is described.

Allen, M. A.↗

TMS communications hardware. Volume 2: Bus interface unit

A prototype coaxial cable bus communication system used in the Trend Monitoring System to interconnect intelligent graphics terminals to a host minicomputer is described. The terminals and host are connected to the bus through a microprocessor-based RF modem termed a Bus Interface Unit (BIU). The BIU hardware and the Carrier Sense Multiple Access Listen-While-Talk protocol used on the network are described.

Brown, J. S.↗

Fiber optic data bus using Frequency Division Multiplexing (FDM) and an asymmetric coupler

A fiber optic data bus, using frequency division multiplexing (FDM) is discussed. The use of FDM is motivated by the need to avoid central control of the bus operation. A major difficulty of such a data bus is introduced by the couplers. An efficient low loss access coupler with an asymmetric structure is presented, and manufacturing processes for the coupler are proposed.

Zanger, M.↗

Multi-access fiber optic data bus using FDM/FSK

The major thrust was to develop a T coupler with very low (0.1 0.2dB) in-line loss. This is essential to any multiaccess bus structure where the word multi implies fifteen or more nodes on the bus, and it is tacitly assumed to be a passive bus. (Reliability considerations tend to exclude the use of active nodes - repeater nodes.)

Zanger, H.↗

Interface of the transport systems research vehicle monochrome display system to the digital autonomous terminal access communication data bus

An upgrade of the transport systems research vehicle (TSRV) experimental flight system retained the original monochrome display system. The original host computer was replaced with a Norden 11/70, a new digital autonomous terminal access communication (DATAC) data bus was installed for data transfer between display system and host, while a new data interface method was required. The new display data interface uses four split phase bipolar (SPBP) serial busses. The DATAC bus uses a shared interface ram (SIR) for intermediate storage of its data transfer. A display interface unit (DIU) was designed and configured to read from and write to the SIR to properly convert the data from parallel to SPBP serial and vice versa. It is found that separation of data for use by each SPBP bus and synchronization of data tranfer throughout the entire experimental flight system are major problems which require solution in DIU design. The techniques used to accomplish these new data interface requirements are described.

Easley, W. C.↗

Data Bus Adapts to Changing Traffic Level

Access becomes timed when collisions threaten. Two-mode scheme used to grant terminals access to data bus. Causes bus to alternate between random accessibility and controlled accessibility to optimize performance and adapt to changing data-traffic conditions. Bus is part of 100-Mb/s optical-fiber packet data system.

Lew, Eugene↗