Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “burn-in”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

68 records · Page 4

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

Results of All Polyimide, Etched Foil Heater Qualification and Failure Limit Testing

Standard FEP (Fluorinated Ethylene Propylene resin) polyimide (SFP) or Kapton film heaters—which have a long history of space flight—are output-power limited by the melting point of Teflon which is used as an adhesive and insulator between the encasing layers of Kapton. The limit is expressed as a power density or through maximum operating temperature limits. All-polyimide (AP) heaters (also known as adhesive-less heaters) do not contain FEP Teflon between the layers of Kapton so the heaters are unconstrained by the melting point of Teflon. Thus, AP heaters have a higher maximum power density and operating temperature. AP heaters have not been qualified or flown on JPL missions but could be useful in applications that require a higher power density (Watt density) than the SFP heaters can support. The purpose of this paper is to document the qualification and property testing of the AP heaters for flight purposes. JPL (Jet Propulsion Lab.) tested several varieties of all-polyimide heaters to determine their functional equivalence to the standard heater which has substantial flight heritage and to determine their maximum limits. Tests included standard in-air burn-in tests, maximum power testing, lead pull strength, process qualification verification (PQV), long duration thermal cycling, and electro-magnetic compatibility shielding properties for copper-cladded shielded heaters. The results show that the all-polyimide heater appears to be functionally equivalent to the standard heater and has a higher Watt density and maximum operating temperature limit. The tests, test articles, failure analysis of the test articles, and results are described herein. These test results indicate that the all-polyimide heater is ready for flight applications.

Cucullu, Gordon C., III↗

PHALANX: Expendable Projectile Sensor Networks for Planetary Exploration

Technologies enabling long-term, wide-ranging measurement in hard-to-reach areas are a critical need for planetary science inquiry. Phenomena of interest include flows or variations in volatiles, gas composition or concentration, particulate density, or even simply temperature. Improved measurement of these processes enables understanding of exotic geologies and distributions or correlating indicators of trapped water or biological activity. However, such data is often needed in unsafe areas such as caves, lava tubes, or steep ravines not easily reached by current spacecraft and planetary robots. To address this capability gap, we have developed miniaturized, expendable sensors which can be ballistically lobbed from a robotic rover or static lander - or even dropped during a flyover. These projectiles can perform sensing during flight and after anchoring to terrain features. By augmenting exploration systems with these sensors, we can extend situational awareness, perform long-duration monitoring, and reduce utilization of primary mobility resources, all of which are crucial in surface missions. We call the integrated payload that includes a cold gas launcher, smart projectiles, planning software, network discovery, and science sensing: PHALANX. In this paper, we introduce the mission architecture for PHALANX and describe an exploration concept that pairs projectile sensors with a rover “mothership.” Science use cases explored include reconnaissance using ballistic cameras, volatiles detection, and building timelapse maps of temperature and illumination conditions. Strategies to autonomously coordinate constellations of deployed sensors to self-discover and localize with peer ranging (i.e. a “local GPS”) are summarized, thus providing communications infrastructure beyond-line-of-sight (BLOS) of the rover. Capabilities were demonstrated through both simulation and physical testing with a terrestrial prototype. The approach to developing a terrestrial prototype is discussed, including design of the launching mechanism, projectile optimization, micro-electronics fabrication, and sensor selection. Results from early testing and characterization of commercial-off-the-shelf (COTS) components are reported. Nodes were subjected to successful burn-in tests over 48 hours at full logging duty cycle. Integrated field tests were conducted in the Roverscape, a half-acre planetary analog environment at NASA Ames, where we tested up to 10 sensor nodes simultaneously coordinating with an exploration rover. Ranging accuracy has been demonstrated to be within +/-10cm over 20m using commodity radios when compared to high-resolution laser scanner ground truthing. Evolution of the design, including progressive miniaturization of the electronics and iterated modifications of the enclosure housing for streamlining and optimized radio performance are described. Finally, lessons learned to date, gaps toward eventual flight mission implementation, and continuing future development plans are discussed.

Dille, Michael↗

Development of the GeoNEX Level 2G Products: Exploiting the Diurnal Variability of TOA Reflectance in Atmospheric Correction

This study develops a new atmospheric correction algorithm to generate the Level 2G products, in particular the gap-filled Surface Reflectance at 10-minute time steps, for the Geostationary-NASA Earth Exchange (GeoNEX) project. The algorithm is based on the MODIS MAIAC (Multi-Angle Implementation of Atmospheric Correction) framework but with significant modifications to exploit angular/temporal information from the diurnal variability of the GeoNEX L1G TOA (Top-of-Atmosphere) reflectance. The algorithm starts by evaluating the roughness/smoothness of the diurnal time series of the TOA reflectance. Because rapid changes in TOA reflectance are generally caused by passing clouds or shadows, rough segments of the time series are automatically filtered out while the smooth segments are further tested for brightness and temperature to identify clear-sky and snow-free observations. Next the algorithm runs the MAIAC RTM (Radiative Transfer Model) to retrieve the Ross-Thick-Li-Sparse (RTLS) BRDF model parameters and the daily-mean atmospheric optical depth (AOD) that allow the RTM to optimally simulate the observed diurnal variability of clear-sky TOA reflectance. Once the initial RTLS parameters are retrieved after the algorithm’s burn-in period, they are used as the prior information to predict the AOD level for the next days, while the subsequent clear-sky observations are used to make necessary adjustments to the RTLS parameters in an continuous fashion. This “prediction-analysis” cycle is then iterated to process the full time series of the L1G data, skipping only total-cloudy days or when surface snow is detected. We tested the algorithm over a list of selected AERONET sites. The retrieved results (the daily mean AOD and the RTLS parameters) reasonably agree with the ground-based measurements. Importantly, the results indicate that the diurnal cycles of surface reflectance are continuous functions of the illumination-view geometry. Thus we can use the retrieved RTLS model to accurately fill in data gaps on partial cloudy days. Also, our algorithm is totally independent from the traditional approaches based on the use of spectral band ratios between the shortwave infrared (e.g., 2.2µm) and the visible (e.g., 0.47µm and 0.64µm) bands. Our results thus demonstrate that the high-frequent diurnal geostationary observations contain unique information that helps us improve atmospheric correction of remote sensing data.

GeoNEX↗

A Paradigm Shift in Quality Assurance of COTS Capacitors for Space Applications

Limitations of a traditional approach to screening and qualification of COTS capacitors for space applications that is based on burn-in and life test requirements described in the relevant military specifications are analyzed. An alternative approach that is originated from analysis of highly accelerated life testing (HALT) of capacitors susceptible to wear-out failures and allows for assessments of the risks of failure during the mission is suggested. Examples include results of reliability testing of advanced BME ceramic capacitors, polymer tantalum capacitors and multianode manganese oxide tantalum capacitors.

Alexander A Teverovsky↗

Infant Mortality and Wear-Out Failures in Polymer and MnO2 Tantalum Capacitors

Reliability testing of modern tantalum capacitors shows the presence of both types, infant mortality (IM) and wearout (WO) failures. To assure reliable operation, the probability of IM failures should be reduced to below the specified level, and the time of WO inception should be greater than the required useful life of the parts at operation conditions. In this work, several types of MnO2 and polymer cathode tantalum capacitors have been tested at highly accelerated conditions to assess voltage acceleration factors, determine adequate burn-in conditions, and assess the useful life. A modified time dependent dielectric breakdown (TDDB) model has been suggested to explain both types of failure, and a physical mechanism of degradation that is based on migration and reactions of oxygen vacancies explains increase of the defect related, IM failures with the level of stress.

tantalum capacitors↗

A Novel Atmospheric Correction Algorithm to Exploit the Diurnal Variability in Hypertemporal Geostationary Observations

This study developed a new atmospheric correction algorithm, GeoNEX-AC, that is independent from the traditional use of spectral band ratios but dedicated to exploiting information from the diurnal variability in the hypertemporal geostationary observations. The algorithm starts by evaluating smooth segments of the diurnal time series of the top-of-atmosphere (TOA) reflectance to identify clear-sky and snow-free observations. It then attempts to retrieve the Ross-Thick–Li-Sparse (RTLS) surface bi-directional reflectance distribution function (BRDF) parameters and the daily mean atmospheric optical depth (AOD) with an atmospheric radiative transfer model (RTM) to optimally simulate the observed diurnal variability in the clear-sky TOA reflectance. Once the initial RTLS parameters are retrieved after the algorithm’s burn-in period, they serve as the prior information to estimate the AOD levels for the following days and update the surface BRDF information with the new clear-sky observations. This process is iterated through the full time span of the observations, skipping only totally cloudy days or when surface snow is detected. We tested the algorithm over various Aerosol Robotic Network (AERONET) sites and the retrieved results well agree with the ground-based measurements. This study demonstrates that the high-frequency diurnal geostationary observations contain unique information that can help to address the atmospheric correction problem from new directions.

atmospheric correction↗

Reliability Assurance for COTS Capacitors

Burn-in (BI) and life testing (LT) are the most important reliability related elements of quality assurance for components used in space systems. This presentation discusses the need of transition from the existing approach to BI, LT, and destructive physical analysis (DPA) of COTS capacitors that is based on military specifications to an alternative approach that is based on Physics of Failure and HALT.

reliability↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Power Prediction

INL has evaluated and refurbished General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. The generator has passed all the INL internal reviews, an end item data package has been delivered to NASA and is ready fueling for a mission. NASA requested a user’s guide for F5R with enough detail for a prospective mission proposal. This report documents the development of the power prediction model used in the user’s guide. The prediction evaluated the thermoelectric “burn-in” and the graceful degradation modes of the missions and developed a thermal inventory dependent equation that predicts the power that matches Galileo, Cassini, and PNH within a three-standard deviation of ±1%. This prediction is only valid for the 30 VDC load voltage of these missions.

30 - DIRECT ENERGY CONVERSION↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Power Prediction

INL has evaluated and refurbished General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. The generator has passed all the INL internal reviews, an end item data package has been delivered to NASA and is ready fueling for a mission. NASA requested a user’s guide for F5R with enough detail for a prospective mission proposal. This report documents the development of the power prediction model used in the user’s guide. The prediction evaluated the thermoelectric “burn-in” and the graceful degradation modes of the missions and developed a thermal inventory dependent equation that predicts the power that matches Galileo, Cassini, and PNH within a three-standard deviation of ±1%. This prediction is only valid for the 30 VDC load voltage of these missions.

30 - DIRECT ENERGY CONVERSION↗

Unveiling the Morphological and Physical Mechanism of Burn–in Loss Alleviation by Ternary Matrix Toward Stable and Efficient All–Polymer Solar Cells

All–polymer solar cells (All–PSCs) are considered the most promising candidate in achieving both efficient and stable organic photovoltaic devices, yet the field has rarely presented an in–depth understanding of corresponding device stability while efficiency is continuously boosted via the innovation of polymer acceptors. Herein, a ternary matrix is built for all–PSCs with optimized morphology, improved film ductility and importantly, boosted efficiency and better operational stability than its parental binary counterparts, as a platform to study the underlying mechanism. The target system PQM–Cl:PTQ10:PY–IT (0.8:0.2:1.2) exhibits an alleviated burn–in loss of morphology and efficiency under light soaking, which supports its promoted device lifetime. The comprehensive characterizations of fresh and light–soaked active layers lead to a clear illustration of opposite morphological and physical degradation direction of PQM–Cl and PTQ10, thus resulting in a delicate balance at the optimal ternary system. Specifically, the enlarging tendency of PQM–Cl and shrinking preference of PTQ10 in terms of phase separation leads to a stable morphology in their mixing phase; the hole transfer kinetics of PQM–Cl:PY–IT host is stabilized by incorporating PTQ10. Finally, this work succeeds in reaching a deep insight into all–PSC's stability promotion by a rational ternary design, which booms the prospect of gaining high–performance all–PSCs.

14 SOLAR ENERGY↗

NRC Multiphysics Analysis Capability Deployment (FY2021--Part 1)

This report details progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” The tasks completed for this report are as follows: First, Task 1d: The net radiation transfer method was implemented into MOOSE for modeling reactor cavity cooling system geometries. RCCS models for two experiments were created: (1) Natural Convection Shutdown Heat Removal Test Facility (NSTF) experiment R022, and (2) HTTR VCS mockup. For validation, computed temperature distributions were compared to measured temperatures. Next, Task 4c: An algorithm for computing the pebble bed reactor equilibrium core isotopic com-position was developed and an initial version is implemented into the reactor multi-physics code Griffin. Initial results for a simplified axisymmetric pebble bed reactor are presented. Finally, Task 7: generation of a reference plant model for molten salt cooled pebble bed reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗