Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building stock modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Technical Reference Documentation (V.3.3.0)

ResStock™ is the best-in-class building stock energy model for simulating and publishing energy use, utility bills, and greenhouse gas emissions from the residential sector of the U.S. ResStock answers two primary questions: (1) How is energy used in the U.S. residential building stock? and (2) What is the timeseries aggregate impact of energy technologies? Specifically, ResStock quantifies energy use across geographical locations, demographic groups, building types, fuels, end uses, and time of day. Additionally, it details the impact of efficiency or electrification measures: total changes in the amount of energy used by measure; where or in what use cases efficiency or electrification upgrade measures save energy; when or at what times of day savings occur; and which building stock or demographic segments have the biggest savings potential. This model, and the datasets it produces, are foundational to identifying pathways to affordable and equitable decarbonization of the U.S. residential buildings sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Photovoltaics With 40% Rooftop Coverage

This study investigates the impact of adding 40% rooftop coverage of photovoltaics to the U.S. commercial building stock. Panels are modeled as higher performance with 21% rated efficiency, 96% inverter efficiency, 1.10 DC/AC ratio,14% system losses, and azimuth/tilt angles that vary by location. Total panel area is modeled at 40% of the roof area for each model. Total rated PV power for a building is based on the calculated total panel area and the assumed efficiency of 21%. This measure is applied to all buildings modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States

Electrification of fossil-fuel combustion in buildings is a key component of achieving global greenhouse gas emissions targets. We use physics simulations of 550,000 statistically representative households to analyze distributions of the costs and benefits of three air-to-air heat pump performance levels, with and without insulation upgrades, across the diversity of the US housing stock. We find positive greenhouse gas reductions in every US state for all performance levels across five 2022-2038 electric grid scenarios, with full adoption reducing national emissions by 5%-9%. We find that air-to-air heat pumps could be cost effective without subsidies in 59% of households (65 million). However, efficiency is key: whereas minimum-efficiency equipment could increase energy bills in 39% of households, this fraction is only 19% when also upgrading insulation or 5% when using higher-efficiency equipment, though both strategies have higher upfront costs. Such affordability challenges could be addressed through supportive incentives, policy, and innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of behavioral and geographic heterogeneity on residential-sector carbon abatement costs

Analyses of monetary and emissions savings from residential efficiency upgrades usually neglect behavioral differences between consumers. Variations in behavior are frequently large: 13% of the U.S. population sets thermostats for cooling at 20 °C (68 °F) or lower and 15% at 25.5 °C (78 °F) or higher. Efficiency analyses should account for behavioral heterogeneity as well as variations in climate and housing characteristics. We model energy and economic savings of efficiency upgrades for U.S. single-family detached houses, accounting for differences in thermostat settings, climate zone, fuel prices, and home characteristics. We consider five efficiency interventions: wall insulation, attic insulation, air sealing, high-efficiency furnaces, and high-efficiency air conditioners. Energy and economic savings vary widely by consumer; the average net present value for wall insulation is $3,020 United States Dollar (USD), but considering heterogeneity, it has a 10th percentile value of -$231 and 90th percentile value of $5,000. Neglecting heterogeneity, technology upgrades can be prioritized from lower to higher carbon abatement costs: air conditioners, wall insulation, furnace, air sealing, and attic insulation. Accounting for heterogeneity reorders this prioritization, and consumer-specific conditions affect mitigation costs such that technologies are mixed in with one another and are no longer arranged one after another. These results indicate that interventions to improve efficiency should consider differences between consumers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BuildStockQuery [SWR-23-58]

BuildStockQuery is a python library designed to simplify and streamline the process of querying massive, terabyte-scale datasets generated by ResStock(TM). ResStock (SWR-19-15) is a U.S. DOE-supported, NREL-built, national residential building energy stock model that enables a new approach to large-scale residential energy analysis across the U.S. by combining large public and private data sources, statistical sampling, detailed sub-hourly building simulations, and high-performance computing. BuildStockQuery offers an intuitive Object-Oriented Programming (OOP) interface to the ResStock output dataset allowing users to easily perform common queries and receive results in familiar pandas DataFrame format, abstracting away the need for complex SQL query. By initializing a query object with the pertinent Athena database and table names, users can easily query for various kinds of insights, for example, timeseries electricity for an end use for a given state grouped by building types.

Adhikari, Rajendra↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock™ v3.2.0 [SWR-19-15 and SWR-20-07]

The ResStock™ analysis tool was built on NREL's OpenStudio® platform, and is a project geared at modeling existing residential building stocks at national, regional, or local scales with a high-degree of granularity (e.g., one physics-based simulation model for every 200 dwelling units), using the EnergyPlus® simulation engine. Information about ComStock™, a sister tool for modeling the commercial building stock, can be found here: https://www.nrel.gov/buildings/comstock.html This repository contains: Housing characteristics of the U.S. residential building stock, in the form of conditional probability distributions stored as tab-separated value (.tsv) files. Comments at the bottom of each file document data sources and assumptions for each. A library of housing characteristic "options" that translate high-level characteristic parameters into arguments for OpenStudio measures, and which are referenced by the housing characteristic .tsv files and building energy upgrades defined in project definition files Project definition files: v2.3.0 and later: buildstockbatch YML files openable in any text editor v2.2.5 and prior: Project folder openable in PAT Unit-level OpenStudio Measures for automatically constructing OpenStudio Models of each representative dwelling unit model: v3.0.0 and later: OpenStudio-HPXML Measures v2.5.0 and prior: OpenStudio Measures Higher-level OpenStudio Measures for controlling simulation inputs and outputs This repository does not contain software for running ResStock simulations, which can be found as follows: Versions 2.3.0 and later only support the use of buildstockbatch for deploying simulations on high-performance or cloud computing. Version 2.3.0 also removed separate projects for single-family detached and multifamily buildings, in lieu of a combined project_national representing the U.S. residential building stock. See the changelog for more details. Versions 2.2.5 and prior support the use of the publicly available OpenStudio-PAT software as an interface for deploying simulations on cloud computing. Read the documentation for v2.2.5.

Horowitz, Scott↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock 2024.2 Dataset [Slides]

In the ResStock 2024.2 dataset, ResStock runs are used to create "what-if" scenarios including energy efficiency measures such as heat pumps, envelope improvements, and electrification of appliances. This dataset release includes 15 measure packages across two weather years and incorporates ResStock improvements in variable speed heat pump modeling, geothermal heat pump modeling, and housing characteristic data updates from RECS 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Natural Gas Demand Response Potential during Extreme Cold Events in Electricity-Gas Coupled Energy Systems

In regions where natural gas is used for both power generation and heating buildings, extreme cold weather events can place the electrical system under enormous stress and challenge the ability to meet residential heating and electric demands. Residential demand response has long been used in the power sector to curtail summer electric load, but these types of programs in general have not seen adoption in the natural gas sector during winter months. Natural gas demand response (NG-DR) has garnered interest given recent extreme cold weather events in the United States; however, the magnitude of savings and potential impacts—to occupants and energy markets—are not well understood. We present a case-study analysis of the technical potential for residential natural gas demand response in the northeast United States that utilizes diverse whole-building energy simulations and high-performance computing. Our results show that NG-DR applied to residential heating systems during extreme cold-weather conditions could reduce natural gas demand by 1–29% based on conservative and aggressive strategies, respectively. This indicates a potential to improve the resilience of gas and electric systems during stressful events, which we examine by estimating the impact on energy costs and electricity generation from natural gas. We also explore relationships between hourly indoor temperatures, demand response, and building envelope efficiency.

03 NATURAL GAS↗