Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building prototypes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

On the applicability of various levels of detail for occupant behavior representation and modeling in building performance simulation

Occupant behavior (OB) is one of the significant sources of uncertainty in building performance simulation. While OB modeling has received increased attention in the past decade, research on the degree of granularity or level of detail (LoD) required for representing occupants is still in the nascent stages. This paper analyzes the modeling and applicability of three LoDs to represent occupants in building performance assessment. A medium-sized prototype office building located in Chicago, Illinois is used as the simulation case study. Ten occupant-centric attributes are adopted to develop the LoDs for OB representation. We first demonstrate the different modeling approaches required for simulating the three fidelity levels. Later, we illustrate the suitability of the developed LoDs in supporting six building performance use cases across different lifecycle stages. Furthermore, this study intends to provide guidance for the building simulation community on appropriate OB representation to support various use cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Solar Heat and Power Co-Generation System. Final Report, CRADA No. TC02152.0

Final Report, CRADA No. TC02152.0. Date Technical Work Ended: October 28, 2013. This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building. This project was originally designated as an eight (8) month project. However, it was ultimately extended by an additional thirty-five (35) months, for total project duration of forty-three (43) months.

14 SOLAR ENERGY↗

Development of a Solar Heat and Power Co-Generation System. Final CRADA Report

Final Report CRADA No. TC02152.0 Date Technical Work Ended: October 28, 2013. This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Tassajara Technologies, Inc. (TTI), to develop, fabricate and demonstrate a Solar Heat and Power Co-generation System. The technical objectives of this CRADA were to engineer, design and build a prototype Solar Thermal Process Heat and Power Demonstration System that would be suitable for use at the Arc of Hilo food processing facility. This would be accomplished in two phases. The first phase would entail the building of a prototype at Tassajara facilities. Base design parameters, including the subsystem interactions that would produce reliable performance at the lowest cost per watt of energy generated with the desired balance of power and heat to meet the requirements of the designated food processing applications from Arc of Hilo, would be provided by LLNL. The data and design development would be integrated into the second phase engine prototype and solar thermal system that would be built and delivered, with interface requirements to the Miko Building.

14 SOLAR ENERGY↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

An Organic, Direct Bonded Copper, Multi-Layered, Ultra-Low Inductance Package for High-Power UWBG MOSFETs

The most common metalized substrates used in high-power switching packages consist of a ceramic layer such as Aluminum Nitride (AlN) sandwiched between two copper layers. Ceramic substrates are used because it has the key characteristic of having high dielectric strength while being thermally conductive. A large drawback to ceramic substrates is that they do not allow for a multi-layered circuit design. By replacing the traditional ceramic substrate with organic direct bonded copper (ODBC) we can open a wide range of possibilities when it comes to power module layout such as multi-layered circuits and double-sided cooling. Both benefits are critical while packaging high-performance Gallium Oxide (Ga2O3) MOSFETs. Because of Ga2O3's relatively poor thermal conductivity, a double-sided cooled package becomes necessary. Therefore, the use of ODBC provides the flexibility to fabricate copper traces carrying much higher currents, and by creating a multi-layered package, we can drastically reduce the parasitic inductance inside the power module. Achieving lower parasitic inductance is critical for an ultra-fast Ga2O3 package to avoid excessive voltage overshoot and ringing. Using ODBC, we have designed novel packages capable of handling the challenges presented by fast Ga2O3 switching. Using multi-physics modeling software, we can validate our design before building the prototype. Due to the simple process parameters needed to work with ODBC, we can rapidly create prototypes without using external vendors. This flexibility allows us to quickly design, build, and validate highly complex switching power modules to accommodate next generation, Ga2O3 switching devices.

ADVANCED PROPULSION SYSTEMS,ENGINEERING↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Using Gamification to Enhance Mastery of Network Security Concepts

Gamification has proven to be effective in engaging and encouraging people to work towards and achieve goals. Many students struggle to focus on schoolwork, due to a lack of interest, lack of understanding, or other factors unique to the student. Applying gamification elements to education can help engage these students in learning their course material and help them excel academically. This study examines the effectiveness of using gamification techniques to enhance the learning experience in college Computer Science courses. A video game application is utilized to review and reinforce cybersecurity concepts that students have already been taught in class. Previous work has been made on a prototype game build that teaches about ARP (Address Resolution Protocol) components. The focus of this study is to refine and develop the structure of the prototype into a more interactive and enjoyable format with non-competitive and captivating activities that allow students to study at their own pace. An updated version of the game was created that focused on reaching a balance between education and entertainment. The game was used by students enrolled in a cybersecurity class, where pre-survey, post-survey and a focus group interview were conducted to determine how effective the updated version is compared to the current build, in addition to how effective the gamification method is regarding student retention of taught material. The pre-survey and post-survey results revealed an increase in interest and mastery of cybersecurity concepts as a result of playing the game. Students found value in the game as both a method of reviewing material taught in class and an entertaining and engaging game. These results show potential in using gamification in cybersecurity and education.

Hilliard, Kevin↗

National Cost-effectiveness of ANSI/ASHRAE/IES Standard 90.1-2016

The purpose of this analysis is to examine the cost-effectiveness of the 2016 edition of ANSI/ASHRAE/IES Standard 90.1 (ASHRAE 2016). Standard 90.1 is developed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard Standing Project Committee (SSPC) 90.1. It is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2013 to 90.1-2016, as applied in commercial buildings across the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of ASHRAE Standard Standing Project Committee (SSPC) 90.1. The ASHRAE process, however, does not include analysis of the cost-effectiveness of the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting State and local governments. Providing States with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1. To establish the cost-effectiveness of Standard 90.1-2016, three main tasks were addressed: (1) Identification of building elements impacted by the updated standard; (2) Allocation of associated installation, maintenance, and replacement costs; and (3) Cost-effectiveness analysis of required changes In addition to installation, maintenance, and replacement costs, energy cost differences were needed to determine cost-effectiveness. The energy costs for each edition of Standard 90.1 were determined previously under the development of Standard 90.1-2016, as described below. The current analysis builds on the previous PNNL analysis (as outlined in Section 5.2) of the energy use and energy cost saving impacts of Standard 90.1-2016 compared to previous editions. The overall energy savings analysis of Standard 90.1 utilized a suite of 16 prototype EnergyPlus building models in 15 climate locations representing all eight U.S. climate zones. Detailed methodology and overall energy saving results from Standard 90.1-2016 are documented in the DOE technical report titled Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016 (DOE. 2018b).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward a glycyl radical enzyme containing synthetic bacterial microcompartment to produce pyruvate from formate and acetate

Formate has great potential to function as a feedstock for biorefineries because it can be sustainably produced by a variety of processes that don’t compete with agricultural production. However, naturally formatotrophic organisms are unsuitable for large-scale cultivation, difficult to engineer, or have inefficient native formate assimilation pathways. Thus, metabolic engineering needs to be developed for model industrial organisms to enable efficient formatotrophic growth. Here, we build a prototype synthetic formate utilizing bacterial microcompartment (sFUT) encapsulating the oxygen-sensitive glycyl radical enzyme pyruvate formate lyase and a phosphate acyltransferase to convert formate and acetyl-phosphate into the central biosynthetic intermediate pyruvate. This metabolic module offers a defined environment with a private cofactor coenzyme A that can cycle efficiently between the encapsulated enzymes. To facilitate initial design-build-test-refine cycles to construct an active metabolic core, we used a “wiffleball” architecture, defined as an icosahedral bacterial microcompartment (BMC) shell with unoccupied pentameric vertices to freely permit substrate and product exchange. The resulting sFUT prototype wiffleball is an active multi enzyme synthetic BMC functioning as platform technology.

59 BASIC BIOLOGICAL SCIENCES↗

A Multichannel Silicon Package for Large-Scale Skipper-CCD Experiments

The next generation of experiments for light-dark-matter and neutrino searches based on skipper charge-coupled devices (skipper-CCDs) introduces new challenges for the sensor packaging and readout architecture. Scaling the active mass while simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present a silicon multichip module design capable of hosting up to 16 skipper-CCDs, along with the fabrication process for the first prototypes. We thoroughly tested and characterized the assembled prototypes to build an empirical model for the video output signal of skipper-CCDs integrated into the silicon package. We then used this model in simulations to optimize the fabrication process and achieve the robust performance required for the full-scale array, which we validated through a new round of prototype fabrication. We outline the specifications selected for the ongoing production of 1500 silicon wafers that will ultimately add up to a 10-kg skipper-CCD array with 24000 readout channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Engineering Prototype of a Late Stage Ionization Cooling Cell for a Muon Collider

Achieving the low emittances required for a muon collider requires ionization cooling. Much of that cooling occurs in compact cooling cells where superconducting coils and conventional RF cavities are closely interleaved. The real challenges for these cooling cells reside in their engineering challenges: high field solenoids, RF cavities, and absorbers, often designed near technological limits, placed in close proximity to each other. We thus propose to build a prototype ionization cooling cell to demonstrate the capability of constructing an ionization cooling channel reaching the lowest emittances and to provide engineering input for the design of such beamlines.

43 PARTICLE ACCELERATORS↗

An engineering prototype of a late stage ionization cooling cell for a muon collider

Achieving the low emittances necessary for a muon collider requires ionization cooling. Much of that cooling occurs in compact cooling cells where superconducting coils and conventional RF cavities are closely interleaved [1]. The real challenges for these cooling cells reside in their engineering challenges: high field solenoids, RF cavities, and absorbers, often designed near technological limits, placed in close proximity to each other. We thus propose to build a prototype ionization cooling cell to demonstrate the capability of constructing an ionization cooling channel reaching the lowest emittances and to provide engineering input for the design of such beamlines. The magnets and cavities will be powered at their design values, and an absorber will be included along with a mechanism for heating the absorber similarly to how a beam would.

43 PARTICLE ACCELERATORS↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comprehensive review of solar only and hybrid solar driven multigeneration systems: Classifications, benefits, design and prospective

Depending on the application and demands, different products can be generated utilizing multigeneration systems. To drive such systems, solar energy can be used as a primary energy source or in hybridization with other renewable or nonrenewable energy sources. Solar driven multigeneration systems are appealing due to the broad availability of solar energy and related technologies. Here, the objective of this study is to review, categorize and discuss different configurations, benefits, potentials, challenges, future research directions and market perspectives of solar energy-driven multigeneration systems, comprehensively. This study also reviews how solar energy systems can be used to hybridize systems for multigeneration purposes. Regardless of using fossil fuel backup sources, these systems are classified as (1) solar only-driven and (2) hybrid solar-driven, in which solar energy is used together with other renewable sources. Reviewing the literature demonstrates numerous ways to build solar energy-driven multigeneration systems by coupling a variety of different cycles and devices. Such systems offer multiple benefits such as enhancing the efficiency, reducing capital and operating costs and carbon dioxide emission. Hybridizing solar with other renewable energies enables continuous operation and dispatchability management. This review shows that for configuration selection and design, different thermodynamics, economic and environmental aspects should be considered. To advance the solar driven multigeneration systems development, further multidisciplinary research on different aspects of such systems is necessary. Particularly, investigations should focus on building different prototypes and on conducting experimental assessments. Also, new incentives and long-term purchase agreements for the products must be established.

14 SOLAR ENERGY↗

Open-Source Architecture for Multi-Party Update Verification for Data Acquisition Devices

Power grids are integral parts of modern daily life and are increasingly under cyberattack. Common software update processes for grid control devices rely on only one organization to provide verification. This paper roposes a multi-signature software update process to help better secure data acquisition devices from malicious actions by using standard cryptosystems such as TLS. A prototype system build on Linux and off-the-shelf hardware has shown successful update and attack prevention with our customized multi-party update software.

Newberg, Benjamin↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-Development of Oscillating Water Column (OWC) and Offshore Power Station

The project proposed an Oscillating Water Column (OWC) at a low power rating (1-5kW); to build a prototype and perform field testing within 1–3 years and achieving a commercial version of the OWC 3–5 years. We selected the OWC off-the-shelf components to secure the supply-chain sources and to warrant stable and minimum pricing. We want to curtail the capital cost by reducing the weight and volume of the overall system structure at the design level by designing a high-speed turbine generator and optimizing the airspeed amplification. We want to minimize the operational and maintenance (O&M) costs through simplified architecture, minimal parts, modular/plug-and-play, and easy access designs.

16 TIDAL AND WAVE POWER↗