Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Commercial Energy Code Compliance – Just the Facts, Ma’am

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. This paper builds on the methodology presented at the 2016 Summer Study and provides a first glimpse of the results as seen in the field. The field study team has implemented the pilot methodology, compiling a data set of over 200 office and retail buildings in climate zones 2A and 5A. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This paper will review the findings of that analysis, discuss critical aspects of the methodology, such as sampling and recruitment strategies, and identify areas where the greatest return—bang for the buck—exists in improving compliance with codes in commercial buildings. In addition, the team will make specific recommendations for jurisdictions looking to use the methodology to maximize energy code savings achieved in the field.

Cheslak, Kimberly↗

Methodology for Evaluating Energy Savings, Cost-Effectiveness, and Societal Impacts of Commercial Energy Code Changes

This document lays out the Department of Energy’s (DOE’s) methodology for evaluating the cost-effectiveness of energy code and standard proposals and editions. The evaluation is applied to new provisions or editions of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code. The methodology follows standard lifecycle cost (LCC) economic analysis procedures. A cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes; 2) evaluating the incremental and replacement costs related to the changes; and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methodology for Evaluating Commercial Energy Code Updates

This document lays out the Department of Energy’s (DOE’s) methodology for evaluating the cost-effectiveness of energy code and standard proposals and editions. The evaluation is applied to new provisions or editions of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code. The methodology follows standard lifecycle cost (LCC) economic analysis procedures. A cost-effectiveness evaluation requires three steps: 1) evaluating the energy and energy cost savings of code changes; 2) evaluating the incremental and replacement costs related to the changes; and 3) determining the cost-effectiveness of energy code changes based on those costs and savings over time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Continuum from Energy Codes to Advanced Technologies: A New Approach to Training

In July of 2020, the unamended 2018 IECC became the statewide energy code for the state of Nebraska. This represented a significant energy code advancement over the previous code – the 2009 IECC. To support the implementation of the new code, the Midwest Energy Efficiency Alliance (MEEA), along with in-state partners, including the Nebraska Energy Office and the Nebraska Code Officials Association, applied for and received a FOA award for an integrated and innovative training and education program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Readiness in Residential Energy Code: Technical Brief

This technical brief provides requirements for electric readiness that could be incorporated into model residential energy codes. It provides background on the basis and benefits of the provisions, and model code language that can be plugged into the IECC or adapted into other energy codes. This brief has been updated to reflect changes in the 2024 IECC.

2021 IECC↗

Modular Multi-family Construction: A Field Study of Energy Code Compliance and Performance through Offsite Prefabrication

Prefabrication in a controlled, factory setting may improve the energy code compliance and energy performance of modular buildings compared to traditional site-built buildings. To test this premise, the work detailed in this DOE-funded commercial field study (EE0009082) compares the energy code compliance of 25 modular and 30 site-built multifamily buildings under construction in Los Angeles, San Francisco, Philadelphia and Seattle representing climate zones 3B, 3C, 4A and 4C respectively. This dataset includes full data on 20 modular and site-built buildings and partial data on 35 modular and site-built buildings that had started prior to or were completed after the 18-month data collection period. This study also compares the post-occupancy energy performance or energy use intensity (EUI) of an additional 23 modular multifamily buildings and 128 site-built multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updating the Building Science Advisor (BSA): A Tool to Assist in the Design of Durable Building Envelopes

Predicting the moisture durability of building envelope components remains challenging due to multiple influencing factors, including material selection, assembly positioning, local climate conditions, air tightness, interior environment, and construction quality. Building codes increasingly emphasize energy efficiency through enhanced insulation and tighter envelopes but offer limited guidance on moisture durability considerations. Consequently, builders face uncertainty, particularly as new materials and assemblies enter the market.The Building Science Advisor (BSA) is a free, web-based expert system developed to address these challenges by providing actionable insights into the moisture durability and energy efficiency of both new and retrofit wall designs. Recently updated, we are now providing version 3.0 of the tool. BSA features significant user interface improvements, enhancing navigation and user interaction through a refreshed, intuitive design. Additionally, the tool incorporates a newly developed database containing pre-simulated wall assembly cases, significantly reducing response times and improving the accuracy of moisture durability assessments. Furthermore, the updated BSA includes moisture content as a performance criterion, providing users with a more comprehensive understanding of moisture-related durability risks. These enhancements enable rapid, reliable assessments tailored to specific climate zones and local building practices. BSA continues to offer targeted guidance on wall retrofit scenarios and delivers access to an expanded library of location-specific building science resources.This paper describes these key updates, highlighting the enhanced features, expanded capabilities, and overall improvements to user experience and educational content. The paper includes a demonstration that illustrates how the revised BSA effectively supports practitioners in designing durable, energy-efficient building envelope assemblies.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

All Hands On Deck: Raising the Bar on Whole Building Performance-Based Code Compliance and Above-Code Programs

In 2019 a large-scale national effort was launched with support from U.S. Department of Energy, Pacific Northwest National Laboratory and Northwest Energy Efficiency Alliance (NEEA). The project aimed to develop a long-term vision and a roadmap for achieving a practical application of whole building performance-based code and above code program compliance in commercial buildings. The work was aided by engaging over 70 stakeholders across the country representing jurisdictions, above-code programs such as LEED and ENERGY STAR Multifamily Program, members of the ASHRAE Standard 90.1 and other Standard committees, IBPSA and software developers. The performance path requires whole building energy modeling and is gaining momentum. Many see it as the future of the commercial energy codes and the main pathway for achieving zero energy buildings. The paper describes the findings from a stakeholder survey funded by NEEA on the current state of performance-based path, its market penetration, trends, implementation practices and adoption challenges. It discusses the patterns revealed by experience of the states with decades-long history of performance-based compliance such as Florida and California and opportunities for taking advantage of the synergies between code and above-code programs. In addition, the paper provides an overview of the tools and resources developed as part of the effort including the compliance form for ASHRAE Standard 90.1 Section 11 and Appendix G, modeling submittal review manual, and modeler and reviewer qualification requirements. The tools and resources would help remove market barriers, deliver immediate benefits to jurisdictions and rating authorities, and achieve energy efficiency through whole-building performance path.

TSPR, Performance Based Complinace, Washington Sta↗

An Assessment of Actual and Potential Building Climate Zone Change and Variability From the Last 30 Years Through 2100 Using NASA's MERRA and CMIP5 Simulations

Background: In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2 emission (DOE/EIA "Annual Energy Outlook 2013"). Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climate zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE. Establishing the current variability and potential changes to future building climate zones is very important for increasing the energy efficiency of buildings and reducing energy costs and emissions in the future. Objectives: This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the DOE/ASHRAE building climate zone maps and then using MERRA to define the last 30 years of variability in climate zones for the Continental US. An atmospheric assimilation is a global atmospheric model optimized to satellite, atmospheric and surface in situ measurements. Using MERRA as a baseline, we then evaluate the latest Climate Model Inter-comparison Project (CMIP) climate model Version 5 runs to assess potential variability in future climate zones under various assumptions. Methods: We derive DOE/ASHRAE building climate zones using surface and temperature data products from MERRA. We assess these zones using the uncertainties derived by comparison to surface measurements. Using statistical tests, we evaluate variability of the climate zones in time and assess areas in the continental US for statistically significant trends by region. CMIP 5 produced a data base of over two dozen detailed climate model runs under various greenhouse gas forcing assumptions. We evaluate the variation in building climate zones for 3 different decades using an ensemble and quartile statistics to provide an assessment of potential building climate zone changes relative to the uncertainties demonstrated using MERRA. Findings and Conclusions: These results show that there is a statistically significant increase in the area covered by warmer climate zones and a tendency for a reduction of area in colder climate zones in some limited regions. The CMIP analysis shows that models vary from relatively little building climate zone change for the least sensitive and conservation assumptions to a warming of at most 3 zones for certain areas, particularly the north central US by the end of the 21st century.

Stackhouse, Paul W., Jr.↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

Multi-technology building system retrofits for utility incentive programs: Savings, costs and baseline considerations

Utility incentive programs are an important channel to support the deployment of energy efficiency in buildings. To date, these programs have largely been limited to single-component strategies. However, many utilities are now motivated to identify and develop multi-component system retrofits to achieve deeper energy savings, which are essential to achieving broader energy and greenhouse gas reduction goals in the buildings sector. In this paper we present the energy savings, demand reductions, and cost-effectiveness of 16 systems retrofit packages in six utility regions in the United States. These results are being used by these utilities to inform and develop incentive programs for systems retrofits. Our analysis shows that packages with proven lighting and HVAC measures can provide 5–22% whole building annual energy savings, and 13–22% annual energy costs savings, using utility incentive program baselines (code and existing building). The packages are reasonably cost effective for replace-on-burnout but generally not for a retrofit scenario prior to end of equipment life. Demand response can increase both the energy savings and energy cost savings, further improving the cost effectiveness of these packages. We analyzed the impact of using existing building vs. code baselines for calculating savings, showing that the choice of baseline in developing utility incentive programs has a substantial impact on the attributable energy savings to a program, with significant implications for the overall viability of a program (generally savings against existing building condition are higher and improve project and program cost-effectiveness).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of future weather data for assessing climate change impacts on buildings and energy systems

The effectiveness of climate change impact assessments and the development of adaptation strategies depend on the availability of high-quality future weather data. However, significant gaps exist between the needs of the energy research community and the focus of the climate modeling community, primarily due to a historical lack of communication and collaboration between the two groups. Here, to address this issue, this work provides a comprehensive overview of the critical aspects involved in creating future weather data for building and energy system modeling, including emissions scenarios, general circulation models, downscaling methods, categories of future weather data, and uncertainties in climate simulations. Moreover, it critically evaluates the applicability and suitability of various types of future weather data in five key application scenarios: energy use analysis, resilience analysis, HVAC design, utility-scale analysis, and renewable energy analysis. Finally, this work presents recommendations for high-level actions and research directions to foster collaboration between the energy research and climate modeling communities and to promote the integration of future weather data into energy codes and the design practices of buildings and energy systems.

Climate change↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2022

The purpose of this analysis is to examine the cost-effectiveness of the 2022 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1 and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2022, compared to the previous 90.1-2019 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated energy codes. This information also informs the development of future editions of Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

National Cost-Effectiveness of the Residential Provisions of the 2024 IECC

This analysis focuses on single-family and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). The IECC is developed by the International Code Council (ICC) on a 3-year cycle through a public development and consensus process. While proponents of code changes often include the energy and cost-effectiveness criteria for their respective code change, the IECC process does not include an energy or cost-effectiveness analysis of the entire edition of the code. PNNL evaluated the cost effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2024 edition of the IECC, hereafter referred as the 2024 IECC, compared to those in the prior edition, the 2021 IECC. The simulated performance path and the Energy Rating Index (ERI) path (introduced in the 2015 IECC) are not considered in this analysis due to the wide variation in building construction characteristics that are allowed.

2024 IECC↗

End-Use Analysis of ASHRAE Standard 90.1-2019

This article summarizes the analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. The results represent simulated energy use based on) Commercial Prototype Building Models1 across representative climate zones in the United States, as defined by Standard 90.1. PNNL examined the resulting simulation outputs to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗