Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes: Measured Data From Select Southeastern States

Little data is available that quantifies IAQ or associates contaminant levels with air exchange in U.S. homes. To address this gap, the U.S. Department of Energy (DOE) Building America Program conducted a study to characterize IAQ in U.S. homes constructed since 2013, along with presence, functionality, and occupant use of control measures. Specific objectives of this study effort included: Measuring time-integrated concentrations and temporal profiles of established contaminants of concern; monitoring the use of ventilation equipment; and tracking activities that impact air pollutant emissions and removal processes in typical homes in various climate zones; Characterizing the prevalence, type, and installed performance of mechanical ventilation equipment in new homes; exploring regional variations in system designs and performance; Investigating associations between contaminant levels and the presence of control measures including whole-house mechanical ventilation (WHMV). The study engaged research teams to collect data at a regional level. This report introduces the study protocol and presents and discusses high-level results obtained from Florida Solar Energy Center (FSEC) data collection efforts in the southeastern U.S. states of Florida, Georgia, and South Carolina.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal to Decadal Variability in Focused Groundwater and Contaminant Discharge along a Channelized Stream

Abstract Focused groundwater discharge to streams is problematic at contaminated sites because high fluxes can limit natural attenuation in the hyporheic zone. However, information on location, spatial evolution, and temporal persistence of springs in unlithified sediments over multiyear time scales is limited. We examine discharge at point (~1‐m) to reach (~300‐m) scales along a stream that intercepts trichloroethene and technetium‐99 plumes from a Superfund site. During 2011 to 2012, we seasonally monitored stream and spring flow and contaminant concentrations, along with probing streambed temperatures on a grid in winter and summer, building on prior monitoring during 1999 to 2002. Baseflow measured by both gauging and dye dilution generally increased with distance downstream, and stream and spring discharge varied seasonally, from minima in October to January to maxima in February to June. Thermal anomalies identified by probing occupied approximately 3% to 6% of the reach and typically coincided with visible springs or seeps. Locations of anomalies were similar to those identified in summer 2002, although some orifices disappeared and others emerged. Vertical groundwater fluxes calculated from probing tended to be less than net fluxes calculated from stream discharge, perhaps in part because the assumption of one‐dimensional, steady‐state flow in calculating point fluxes was simplistic. Maximum contaminant concentrations and fluxes decreased between 1999 to 2001 and 2011 to 2012 as a result of partial capture by an upgradient pump‐and‐treat system. Our findings confirm that springs in unlithified sediments can remain stationary within a few meters over decadal time scales, and seasonal variability in discharge can be greater than decadal variability.

Tripathi, Ganesh N.↗

Project 57 Air Monitoring Report: (Jan 1 - Dec 31 2018)

During the late 1950s, the Atomic Energy Commission (AEC) (now the U.S. Department of Energy [DOE]) conducted a series of safety experiments to determine if a nuclear device subjected to a large conventional explosives detonation would result in a nuclear yield. The AEC obtained temporary use of a large portion of western Emigrant Valley from the U.S. Department of Defense (DOD) for one of these experiments: Project 57. Following the Project 57 safety experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Emigrant Valley is part of the Nevada Test and Training Range (NTTR). For safety and security reasons, access to the NTTR is controlled using both physical (i.e., fences) and administrative (e.g., signs and postings) controls. Therefore, the public cannot access the Project 57 site and there are no known human receptors that routinely access the site. Project 57 was detonated on April 24, 1957, in Emigrant Valley approximately 13 mi (21 km) northeast of the north end of Yucca Flat. This test was undertaken to develop: (1) a means of estimating immediate distribution and long-term redistribution of plutonium dispersed during a nonnuclear detonation; (2) biomedical evaluation techniques for use in likely plutonium-laden environments; (3) methods of decontaminating ground areas, pavements, and building materials; and (4) alpha survey instruments and field monitoring procedures to promptly estimate contaminant deposition. Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the ground surface. Various radiological surveys have been performed in the area since Project 57 was conducted. The AEC delineated the area containing radioactive material based on radioactivity surveys performed shortly after the test was conducted. A designated Contamination Area (CA), marked by a fence, was established later. The distribution of americium-241 (Am-241) in the area was determined again in a 1997 flyover, which showed Am-241 ranging from as much as 70,000 counts per second (cps) at ground zero to background (<70 cps). This survey also documented Am-241 radioactivity on the ground surface beyond the east side CA fence at levels of up to 150 cps. In 2007, the DOE expanded the CA by posting “Contamination Area” signs 200 ft to 400 ft (60 m to 120 m) beyond the original fence, which formed a new CA boundary.

54 ENVIRONMENTAL SCIENCES↗

3-D Radiological Data Acquisition, Visualization and Modeling - 20211

The U.S. Army Corps of Engineers (USACE) was tasked to investigate and remediate low activity radiological contamination from research and production of the nation's first nuclear weapons at the former DuPont Chambers Works Formerly Utilized Sites Remedial Action Program (FUSRAP) site (DuPont). The DuPont site had several buildings used for the Manhattan project that were demolished in the 1940's and 1950's apparently using heavy earthmoving equipment. Some of the contaminated rubble from the demolition appears to have been spread out by this equipment resulting in somewhat random scattering of radiologically contaminated soil and debris along with aqueous spills. Traditional investigative methods such as soil borings, test pits and 2-dimensional gamma walkovers were only partially successful in delineating the radiological contamination at the site. It was feared that even 'chasing' the contamination during remediation would miss contamination if the demolition resulted in discontinuous trails of radiologically contaminated soils. In evaluating the data generated over the interceding decades, the USACE determined that a better method to collect and process the remedial action radiological data was needed to enable the project team to optimize predictive planning and meet documentation expectations. The purpose of this paper is to provide an overview of the effort and progress to combine and organize radiological survey methods into a highly flexible sampling, modeling, and decision analysis approach that emphasizes the quality of decision-making during remediation. This innovative system blends multiple tools to develop a methodology that can extend MARRSIM [1] into the subsurface and provide tools that can be applied to other sites. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The TRANSCEND University Consortium: Theme 2 - Site Decommissioning, Deconstruction and Remediation - 20329

This paper will discuss the aims, objectives and progress to-date under Theme 2 of the TRANSCEND consortium project: Site decommissioning, deconstruction and remediation. Decommissioning nuclear sites involves waste retrieval, decontamination, deconstruction and, where necessary, containment and/or remediation of the remaining structure and surrounding land. Critical to management of these processes is limiting radiation exposure for the workforce, restricting the spread of radionuclides in groundwater, surface water and airborne particulates, and minimising the volume of contaminated waste for disposal. The aim of Theme 2 research is to develop new technologies for monitoring, remediation and containment that serve to minimise the volume of radioactively contaminated waste for disposal, for application prior to, during and after retrieval, deconstruction and decontamination operations. Prior research, conducted under the previous DISTINCTIVE project, demonstrated that colloidal silica grout can penetrate low permeability materials (including cement) for hydraulic barrier formation, and improved sorption capacity. The silica grout can be injected at surface using extremely small (potentially gravity-driven) fluid pressures, without the need for borehole drilling. Current work is investigating the erodibility of silica-grouted soils for inhibition of airborne and water-borne particulates as well as enhancing the grout's sorption capacity by addition of other materials to provide a chemical, as well as hydraulic, barrier to subsurface migration. EK remediation uses low voltage DC current to control migration of contaminants in porous media as well as to remove or degrade them. Researchers in the consortium have already demonstrated that low-energy ex-situ EK techniques can be used to provide remediation and volume minimisation for AWE legacy wastes in the UK. Under the current project researchers are building EK test cells containing simulated site materials at laboratory and intermediate(m)-scales to: remove, focus or degrade contaminants (remediation or waste minimisation); and direct subsurface water, chemical and colloid flow (fencing/containment or forced migration). This lab-based research is being informed by numerical models of EK processes that can subsequently be used to design full-scale on-site applications by nuclear site holders. Research under theme 2 of TRANSCEND will ultimately combine novel non-invasive detection technologies with EK techniques and colloidal silica grout barriers, to optimise the containment of radionuclide contamination in soils. Thus, allowing us to detect in-situ contamination, mobilise it to a selected location and grout it in-situ, prior to the initiation of decommissioning and deconstruction operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lawrence Livermore National Laboratory Experimental Test Site 300 (S300): S300 Roadway Improvements - 817 Complex Soil Sampling and Analysis Plan, Addendum 1 (June 2023)

The purpose of this addendum is to amend and update the S300 Roadway Improvements – 817 Complex [project] Soil Sampling and Analysis Plan (SAP) dated May 2023. Field activities to implement the SAP were completed in May 2023 except for SB-17. SB-17 is therefore included in this addendum. In addition, this addendum amends the SAP by covering an expanded scope of work and project limits. The project limits have been expanded to include areas around Building 818. Sampling at the expanded project area is addressed in this addendum by two additional borings for geotechnical and environmental analyses. The project area consists of the access gate and existing access roads for the Process Area complex. Excavation depths are anticipated to be no deeper than 5 feet from current grade. None of the proposed disturbance areas are within known areas of contamination or mapped controlled excavation area (LLNL 2008). Therefore, this addendum proposes a sampling spacing in the vicinity of Building 818 of about 172 feet (Tier 2) in accordance with the Soil Screening and Management Plan (LLNL 2022). The information contained in this addendum supersedes the May 2023 SAP. However, this addendum only addresses elements of the May 2023 SAP that were modified. Elements of the May 2023 SAP that have not been modified are relevant and will remain in effect.

54 ENVIRONMENTAL SCIENCES↗

CO 2 supplementation eliminates sugar-rich media requirement for plant propagation using a simple inexpensive temporary immersion photobioreactor

In vitro plant propagation systems such as temporary immersion bioreactors (TIBs) are valuable tools that enable production of disease-free plants with improved traits. However, TIB systems can be expensive, difficult to implement, and prone to contamination due to sugar rich propagation media. Using rapidly growing chicory root cultures to expedite design-build-test cycles, we report here an improved, low-cost version of a previously reported Hydrostatically-driven TIB (Hy-TIB) that facilitates economical use of gas mixtures. Bioreactor improvements include decreased material costs, expanded modes of operation, and a horizontal orientation of a plastic film plant growth chambers that increase propagule light exposure. To take advantage of these improvements, we describe here experiments that evaluate the impacts of elevated CO 2 on propagation of cacao (Theobroma cacao) secondary embryos and nodal cultures of yam (Dioscorea spp.) during both phototrophic and photomixotrophic growth. Our experiments show that elevated CO 2 during plant propagation significantly improved both cacao and yam propagule development and eliminated the need for supplemental sugars in tissue culture growth media. Thus, our improved Hy-TIB shows potential as a simple, low-cost, and scalable propagation platform with cost-effective gas composition control and reduced risk of contamination overgrowth. We provide detailed instructions for assembly of this Hy-TIB design and discuss the implications of its adoption in food-insecure regions of the world.

59 BASIC BIOLOGICAL SCIENCES↗

IER 555: Godiva Benchmark Update CED-2 (Final Design Report)

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluation of the Godiva IV critical assembly, HEU-MET-FAST-086: GODIVA-IV DELAYED-CRITICAL EXPERIMENTS (HMF-086), was completed by Russ Mosteller. Five critical experiment configurations performed at the Los Alamos National Laboratory (LANL) Technical Area (TA)-18 were evaluated as acceptable benchmark cases. The five cases consist of four delayed critical configurations which differ in control rod positions and one prompt critical configuration. All cases calculated a lower $k_{eff}$ than measured by experiment. This data is referred to as the TA-18 Godiva IV benchmark in this report. In 2005, Godiva IV was disassembled for relocation to the Nevada Test Site (NTS), now Nevada National Security Site (NNSS), at the National Criticality Experiments Research Center (NCERC). Following the disassembly and subsequent reassembly and startup of Godiva IV at NCERC, additional information about the Godiva IV components was obtained. An errata note was added to the HMF-086 evaluation in the ICSBEP handbook to provide this new information until a revision to the benchmark evaluation could be performed. In addition to those corrections, there are differences between the Godiva IV assembly at TA-18 and the Godiva IV assembly at NCERC. These differences include both assembly-specific differences (differences in the safety block gap, differences in the control rod positions, a new NCERC Top Hat and contamination shield) as well as environmental differences, such as the size and shape of the experimental building where the assembly is located. An additional model with similar cases, referred to as the NCERC Godiva IV benchmark in this report, will be added to the revised HMF-086 to capture these additional differences. This will provide the best benchmark model of Godiva for use by those performing experiments at NCERC. The IER 555 CED-2 report documents the information that will be updated in the HMF-086 revision, both the corrections to the TA-18 Godiva IV benchmark and the subsequent changes to create a NCERC Godiva IV benchmark. It describes the measurements that will be performed for cases similar to those performed at TA-18. It also describes measurements that will be included in the evaluation as additional data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling intrinsic galaxy alignment in the MICE simulation

The intrinsic alignment (IA) of galaxies is potentially a major limitation in deriving cosmological constraints from weak lensing surveys. In order to investigate this effect, we assign intrinsic shapes and orientations to galaxies in the light-cone output of the MICE simulation, spanning ~ 5000 deg 2 and reaching redshift Z = 1.4. This assignment is based on a semianalytic IA model that uses photometric properties of galaxies as well as the spin and shape of their host halos. Advancing on previous work, we include more realistic distributions of galaxy shapes and a luminosity-dependent galaxy-halo alignment. The IA model parameters are calibrated against COSMOS and BOSS LOWZ observations. The null detection of IA in observations of blue galaxies is accounted for by setting random orientations for these objects. We compare the two-point alignment statistics measured in the simulation against predictions from the analytical IA models NLA and TATT over a wide range of scales, redshifts, and luminosities for red and blue galaxies separately. We find that both models fit the measurements well at scales above 8h -1 Mpc, while TATT outperforms NLA at smaller scales. The IA parameters derived from our fits are in broad agreement with various observational constraints from red galaxies. Finally, we build a realistic source sample, mimicking DES Year 3 observations and use it to predict the IA contamination to the observed shear statistics. We find this prediction to be within the measurement uncertainty, which might be a consequence of the random alignment of blue galaxies in the simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods—A Practical Approach to the Reversible Hydrogen Electrode Scale

Accurately quantifying applied potential is important to ensuring the comparability, accuracy, and precision of electrochemical studies. Reference electrodes (REs) enable knowledge/determination of the applied potential at electrodes in electrochemical systems. Ultimately, the choice of RE will depend on the particular requirements of a given electrochemical system, however, we note it is imperative to ensure the accuracy of the RE potential and its proper translation to a standardized scale. In this work, we highlight that while there are many commercially available REs, these must be experimentally calibrated to a reliable and practical standard potential scale, for instance the reversible hydrogen electrode (RHE) scale for aqueous systems. With representative data, we provide streamlined instructions on how to calibrate any RE to the RHE scale. We also provide guidance to mitigate and/or avoid possible electrolyte contamination issues arising from REs. Moreover, we offer a step-by-step guide on how to build a practical RHE RE, which may be a suitable and desirable option in certain applications. Our work emphasizes the need for the continuous adoption of standardized reference potential scales and demonstrates the versatility of the RHE scale, particularly in aqueous electrochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensor Recommendations for Long Term Monitoring of the F-Area Seepage Basins

In mid-2018, a new paradigm for long-term monitoring was developed after of decade of applied research projects funded by the Department of Energy’s office of Environmental Management Technology Development program. The program at SRNL was focused on transitioning complex environmental waste sites from active to passive remediations strategies. A key result of these studies was that the use of enhanced attenuation approaches at radiologically contaminated sites will result in the creation of secondary source areas in the subsurface that will require monitoring for decades. Alternative monitoring approaches are being developed and tested at the Savannah River Site’s F-Area Hazardous Waste Management Facility, the new paradigm provides innovative solutions that will significantly lower costs of monitoring through the coupling of data collection, machine learning and deterministic groundwater modeling. The foundation of this approach is a well-optimized network of sensors for measuring hydrogeochemical master variables that control, and therefore act as indicators of groundwater contaminant transport. By monitoring changes in the controlling master variables over time arising from geological and environmental shifts, predictive modelling can assist with identifying new strategies for ensuring regulatory requirements are met if trends toward conditions for potential remobilization of attenuated contaminants are detected. In this report, we evaluated commercially available single parameter sensor platforms (e.g., temperature/depth) and configurable multi-parameter sensor platforms (e.g., pH, oxidation-reduction potential, temperature, depth, dissolved oxygen, and conductivity). Each was scored using an optimization function based on how well the system supports the proposed long-term monitoring paradigm, in general, and the site-specific conditions at F-Area, in particular. Several viable sensor systems were identified. Of these, a combined platform including the In-Situ Aqua TROLL 500 multi-parameter sensor platform and the In-Situ temperature/depth sensor had the highest rating and was identified as the most suitable candidate for installation and monitoring of the master variables and potentiometric surface that control groundwater contaminant plumes emanating from the F-Area Seepage Basins. The discussion of recommended potential deployment locations builds upon recommendations made by Denham et al (2019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phased Construction Completion Report for Decontamination Laundry Demolition at the Oak Ridge National Laboratory

This Phased Construction Completion Report (PCCR) documents completion of demolition, waste disposition, and slab stabilization activities of Building 2523 (Decontamination Laundry) for the Oak Ridge National Laboratory (ORNL). The Decontamination Laundry is located directly north of the intersection of White Oak Avenue and the 2519 Access Road. This demolition scope included the removal of the above-grade structures and facility components associated with Building 2523. This scope included the removal of Building 2523 (and all remaining contents inside), Trailer 2523A (and all remaining contents inside), an above-grade wastewater tank, and a wooden access porch connecting Buildings 2523 and Trailer 2523A. On the north side of Building 2523, above-grade portions of selected remaining foundations/stairs were removed from former Building 2517 to make room to stage waste containers. Building 2621 is west of the Laundry Building and Buildings 2547 and 2649 are to the east, while Building 2525 is to the north. Building 2523 is located within Bethel Valley Exposure Unit (EU) 3. The total area of the EU is approximately 39 acres. The area within EU 3 is bounded by First Street on the west, Central Avenue on the north, Third Street on the east and south. The slab of Building 2523 has been stabilized with a cap of flowable fill concrete and asphalt to contain residual radiological contamination and to provide surface suitable for vehicle parking. No below-grade demolition actions were performed during this task.

99 GENERAL AND MISCELLANEOUS↗

Grazer-induced changes in molecular signatures of cyanobacteria

Algal biomass production is an emerging renewable source of fuels, nutrients, manufacturing materials, and pharmaceuticals. Industrial-scale production is predominantly performed in open raceway ponds that are inexpensive to build, operate, and maintain compared to closed bioreactors. However, these open pond systems suffer from increased opportunities for biological contamination from predators, pathogens, and competitors, which result in reduced biomass quality and yields and often the complete destruction of the crop over a short period of time. Early detection of contaminants is a necessary step of integrated pest management for triggering and informing interventions to prevent crop losses. To develop a sensitive method of detection utilizing mass spectrometry (MS), we used three methods – imaging mass spectrometry (imaging MS), liquid chromatography MS/MS (LC-MS/MS) combined with molecular networking, and gas chromatography MS/MS (GC–MS/MS) – to observe and identify molecular signatures from a model predator-prey system of the heterolobosean amoeba HGG1 preying on the filamentous cyanobacterium Anabaena sp. PCC 7120. Imaging MS enabled the association of molecules with the crop, the predator, or the activity of protozoan grazing, while LC-MS/MS-based molecular networking identified a subset of the grazing-specific signals as the chlorophyll breakdown products pyropheophytin, pheophorbide A, and pyropheophorbide. Application of MS techniques to other amoebacyanobacterial predator-prey pairs allowed categorization of grazing signatures as universal or specific to the species of prey, predator, or the prey-predator pairing, indicating that MS-based techniques can distinguish crops from competitors and potentially identify predators. Finally, GCMS/MS was shown to be capable of monitoring novel volatile organic compounds (VOCs), including those predicted to be released through chlorophyll breakdown, in the headspace over algal cultures under predation. Furthermore, these results demonstrate that the combination of multiple MS technologies creates a predictive framework to identify and catalog relevant molecular signatures for informing crop protection strategies.

09 BIOMASS FUELS↗

Large-scale 2D heterostructures from hydrogen-bonded organic frameworks and graphene with distinct Dirac and flat bands

The current strategies for building 2D organic-inorganic heterojunctions involve mostly wet-chemistry processes or exfoliation and transfer, leading to interface contaminations, poor crystallizing, or limited size. Here we show a bottom-up procedure to fabricate 2D large-scale heterostructure with clean interface and highly-crystalline sheets. As a prototypical example, a well-ordered hydrogen-bonded organic framework is self-assembled on the highly-oriented-pyrolytic-graphite substrate. The organic framework adopts a honeycomb lattice with faulted/unfaulted halves in a unit cell, resemble to molecular “graphene”. Interestingly, the topmost layer of substrate is self-lifted by organic framework via strong interlayer coupling, to form effectively a floating organic framework/graphene heterostructure. The individual layer of heterostructure inherits its intrinsic property, exhibiting distinct Dirac bands of graphene and narrow bands of organic framework. Our results demonstrate a promising approach to fabricate 2D organic-inorganic heterostructure with large-scale uniformity and highly-crystalline via the self-lifting effect, which is generally applicable to most of van der Waals materials.

36 MATERIALS SCIENCE↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Penetration of Fission Products Ions into Complex Solids and the Effect of Ionic Wash Methods

During washing of radiologically impacted building surfaces, penetration of radionuclide ions into complex solids associated with these surfaces may occur. This study investigates the penetration of Cs-137, Sr-85, and Eu-152 solutions into numerous common building materials and radionuclide behavior when these materials were exposed to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for Cs-137 and Eu-152 and 50-80% for Sr-85. Water effectively removed all contaminants from hard nonporous surfaces. Finally, this paper illustrates that a wash penalty factor concept-defined as ratio of the depth at which 50% of the radioactivity is found in the washed sample divided by the depth at which 50% of radioactivity is found in the control-can serve as a way to quantify whether the wash method increases the depth at which contamination penetrates into the material and thus the material becomes more difficult to decontaminate.

building materials↗