Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “breakdown spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Establishing Isotopic Measurement Capabilities using Laser-Induced Breakdown Spectroscopy for the Molten Salt Reactor Campaign

Proof-of-principle H isotope ratios of aqueous aerosol systems and liquid droplets on filter paper have been measured using laser-induced breakdown spectroscopy (LIBS) with root mean square error of prediction values down to 1.9%. Molten salt reactors (MSRs) will consist of a complex chemical and radiological system consistently producing new fission products as the reactor operates. Some of these fission products and/or their daughter species will leave the salt in the reactor off-gas. Monitoring the composition of the off-gas, as well as the salt itself, is important for monitoring reactor performance, including burnup, corrosion, and the concentration of impurities. Tritium is of concern for MSRs because it will be produced from the irradiation of key salt constituents, including Li and Be. LIBS offers an avenue for in situ salt and off-gas monitoring by firing a laser onto or into the sample stream to generate a plasma. The plasma light can be monitored to measure an elemental fingerprint of the sample. Extending this analysis to include isotopic ratios offers a critical expansion of the in situ monitoring capabilities being developed. This study demonstrates the expansion of Oak Ridge National Laboratory’s LIBS capabilities to monitor isotopes and shows how simple calibrations may provide rapid semiquantitative models.

07 ISOTOPE AND RADIATION SOURCES↗

Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dust Removal on Mars Using Laser-Induced Breakdown Spectroscopy

Dust coatings on the surface of Mars complicate and, if sufficiently thick, mask the spectral characteristics and compositional determination of underlying material from in situ and remote sensing instrumentation. The Laser-Induced Breakdown Spectroscopy (LIBS) portion of the Chemistry & Camera (ChemCam) instrument, aboard the Mars Science Laboratory (MSL) rover, will be the first active remote sensing technique deployed on Mars able to remove dust. ChemCam utilizes a 5 ns pulsed 1067 nm high-powered laser focused to less than 400 m diameter on targets at distances up to 7 m [1,2]. With multiple laser pulses, dust and weathering coatings can be remotely analyzed and potentially removed using this technique [2,3]. A typical LIBS measurement during MSL surface operations is planned to consist of 50 laser pulses at ~14 mJ, with the first 5 to 10 pulses used to analyze as well as remove any surface coating. Additionally, ChemCam's Remote Micro-Imager (RMI) is capable of resolving 200 m details at a distance of 2 m, or 1 mm at 10 m [1,4]. In this study, we report on initial laboratory experiments conducted to characterize the removal of dust coatings using similar LIBS parameters as ChemCam under Mars-like conditions. These experiments serve to better understand the removal of surface dust using LIBS and to facilitate the analysis of ChemCam LIBS spectral data and RMI images.

Graff, T. G.↗

Filament-induced breakdown spectroscopy of solids through highly scattering media

Ultrafast laser pulse filamentation in the air can be used for remote sensing by exciting a characteristic optical emission, which is usually referred to as filamentation-induced breakdown spectroscopy. In environments that impede light propagation, such as fog, haze, or clouds, scattering makes it challenging to propagate laser beams and retrieve generated optical signatures. We demonstrate the effectiveness of laser filamentation for simultaneously clearing the path for intense femtosecond pulse propagation in a highly scattering medium, generation of luminous plasma on a solid target, and counter-propagation of a characteristic spectroscopic signal over a cleared channel along the filament path. In a dense cloud, the counter-propagating signal predominantly transits the cleared on-axis path but is highly affected by the negative thermal lensing of a Gaussian beam. Furthermore, these insights enhance our understanding of laser filamentation in atmospheric sensing and could substantially improve remote detection capabilities in poor visibility conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partial Least Squares and Neural Networks for Quantitative Calibration of Laser-induced Breakdown Spectroscopy (LIBs) of Geologic Samples

The ChemCam instrument [1] on the Mars Science Laboratory (MSL) rover will be used to obtain the chemical composition of surface targets within 7 m of the rover using Laser Induced Breakdown Spectroscopy (LIBS). ChemCam analyzes atomic emission spectra (240-800 nm) from a plasma created by a pulsed Nd:KGW 1067 nm laser. The LIBS spectra can be used in a semiquantitative way to rapidly classify targets (e.g., basalt, andesite, carbonate, sulfate, etc.) and in a quantitative way to estimate their major and minor element chemical compositions. Quantitative chemical analysis from LIBS spectra is complicated by a number of factors, including chemical matrix effects [2]. Recent work has shown promising results using multivariate techniques such as partial least squares (PLS) regression and artificial neural networks (ANN) to predict elemental abundances in samples [e.g. 2-6]. To develop, refine, and evaluate analysis schemes for LIBS spectra of geologic materials, we collected spectra of a diverse set of well-characterized natural geologic samples and are comparing the predictive abilities of PLS, cascade correlation ANN (CC-ANN) and multilayer perceptron ANN (MLP-ANN) analysis procedures.

Anderson, R. B.↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic deuterium retention properties of tungsten measured using laser-induced breakdown spectroscopy

Dynamic deuterium (D) retention properties of tungsten (W) are investigated under steady-state D plasma exposure in the PISCES-A linear plasma device. In contrast to static retention, dynamic retention is quickly released from the material at the termination of the incident plasma flux, and thus in-operando laser-induced breakdown spectroscopy (LIBS) measurements have been conducted during steady-state D plasma exposure. A procedure is, first, established to extract the dynamic retention component from the in-operando LIBS D I 656.1 nm line intensity, which can contain contributions from dynamic and static retention as well as background D/D 2 gas, excited by both steady-state and laser-induced plasmas. Using the developed procedure, the dynamic D retention in W is systematically examined while scanning the following plasma exposure parameters: incident ion energy, E i , sample temperature, T s , incident ion flux, Γ i . No clear E i dependence is seen in the range of E i ~ 45–175 eV, as expected from a small variation in the average implantation depth (~3-6 nm) of D in W. The dynamic retention is found to monotonously decrease with increasing T s from 348 to 573 K, while the total static retention is reported to peak at T s ~ 500–600 K. It is revealed that the dynamic retention linearly increases with increasing Γ i , and then saturates at Γ i ≥ 0.75 × 10 21 m –2 s –1 . Possible physical mechanisms for the observed dependence of the dynamic retention on T s and Γ i are discussed. Furthermore, sequential pure He, followed by pure D, plasma exposures show that the dynamic D retention is not strongly affected by He bubbles in the near-surface region.

super-saturated surface layer↗

Laer-induced Breakdown Spectroscopy Instrument for Element Analysis of Planetary Surfaces

One of the most fundamental pieces of information about any planetary body is the elemental and mineralogical composition of its surface materials. We are developing an instrument to obtain such data at ranges of up to several hundreds of meters using the technique of Laser-Induced Breakdown Spectroscopy (LIBS). We envision our instrument being used from a spacecraft in close rendezvous with small bodies such as comets and asteroids, or deployed on surface-rover vehicles on large bodies such as Mars and the Moon. The elemental analysis is based on atomic emission spectroscopy of a laser-induced plasma or spark. A pulsed, diode pumped Nd:YAG laser of several hundred millijoules optical energy is used to vaporize and electronically excite the constituent elements of a rock surface remotely located from the laser. Light emitted from the excited plasma is collected and introduced to the entrance slit of a small grating spectrometer. The spectrally dispersed spark light is detected with either a linear photo diode array or area CCD array. When the latter detector is used, the optical and spectrometer components of the LIBS instrument can also be used in a passive imaging mode to collect and integrate reflected sunlight from the same rock surface. Absorption spectral analysis of this reflected light gives mineralogical information that provides a remote geochemical characterization of the rock surface. We performed laboratory calibrations in air and in vacuum on standard rock powders to quantify the LIBS analysis. We performed preliminary field tests using commercially available components to demonstrate remote LIBS analysis of terrestrial rock surfaces at ranges of over 25 m, and we have demonstrated compatibility with a six-wheeled Russian robotic rover vehicle. Based on these results, we believe that all major and most minor elements expected on planetary surfaces can be measured with absolute accuracy of 10-15 percent and much higher relative accuracy. We have performed preliminary systems analysis of a LIBS instrument to evaluate probable mass and power requirements; results of this analysis are summarized.

Blacic, J.↗

Real-Time Elemental and Isotopic Measurements of Molten Salt Systems through Laser-Induced Breakdown Spectroscopy

Molten salt reactors are an emerging advanced nuclear reactor concept in which the fuel is dissolved into the working fluid in the form of a high-temperature molten salt. The complex, mobile, and corrosive nature of this fluid presents a fundamental challenge for analytical measurements. Tracking species throughout the reactor is important for ensuring proper operation. This article presents laser-induced breakdown spectroscopy (LIBS) used to monitor the elemental composition of a molten salt and corresponding hydrogen isotopic shifts in real-time. A NaNO 3 –KNO 3 eutectic salt was saturated with protium and deuterium gases, then the effluent aerosol stream formed using an argon sparging vessel was monitored with LIBS. This modular LIBS system permitted several spectrometers to be used simultaneously to capture high-resolution isotopic shifts and provide broadband elemental coverage. Further, the results exhibit how LIBS can be used to understand salt–gas chemical and physical interactions such as diffusion. Furthermore, LIBS’ broad elemental coverage can provide greater insight into the chemical reactions within the salt vessel such as the formation of water vapor by monitoring hydrogen and oxygen signatures simultaneously. Ultimately, this study demonstrates the analytical possibilities of LIBS for real-time monitoring of isotopes and elemental composition in molten salt systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

Surface Characterization of Carbon Fiber Reinforced Polymers by Picosecond Laser Induced Breakdown Spectroscopy

Adhesive bonding of composite materials requires reliable monitoring and detection of surface contaminants as part of a vigorous quality control process to assure robust and durable bonded structures. Surface treatment and effective monitoring prior to bonding are essential in order to obtain a surface which is free from contaminants that may lead to inferior bond quality. In this study, the focus is to advance the laser induced breakdown spectroscopy (LIBS) technique by using pulse energies below 100 μJ (μLIBS) for the detection of low levels of silicone contaminants in carbon fiber reinforced polymer (CFRP) composites. Various CFRP surface conditions were investigated by LIBS using ∼10 ps, 355 nm laser pulses with pulse energies below 30 μJ. Time-resolved analysis was conducted to optimize the gate delay and gate width for the detection of the C I emission line at 247.9 nm to monitor the epoxy resin matrix of CFRP composites and the Si I emission line at 288.2 nm for detection of silicone contaminants in CFRP. To study the surface sensitivity to silicone contamination, CFRP surfaces were coated with polydimethylsiloxane (PDMS), the active ingredient in many mold release agents. The presence of PDMS was studied by inspecting the Si I emission lines at 251.6 nm and 288.2 nm. The measured PDMS areal densities ranged from 0.15 to 2 μg/cm(sup 2). LIBS measurements were performed before and after laser surface ablation. The results demonstrate the successful detection of PDMS thin layers on CFRP using picosecond μLIBS.

Rodolfo Ledesma↗

Filament-induced breakdown spectroscopy with structured beams

Filament-induced ablation represents an attractive scheme for long-range material identification via optical spectroscopy. However, the delivery of laser energy to the target can be severely hindered by the stochastic nature of multiple-filamentation, ionization of ambient gas, and atmospheric turbulence. In order to mitigate some of these adverse effects, we examine the utility of beam shaping for femtosecond filament-induced breakdown spectroscopy with Gaussian and structured (Laguerre-Gaussian, Airy, and Bessel-Gaussian) beams in the nonlinear regime. Interaction of filaments with copper, zinc, and brass targets was studied by recording axially-resolved broadband emission from the filament-induced plasma. The laser-solid coupling efficacy was assessed by inferring thermodynamic parameters such as excitation temperature and electron density. While under our experimental conditions the ablation rate with Gaussian- and Laguerre-Gaussian beams is found to be similar, the Airy and Bessel-Gaussian beams offer the advantage of longitudinally extended working zones. These results provide insights into potential benefits of structuring ultrafast laser beams for standoff sensing applications.

47 OTHER INSTRUMENTATION↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. This data set contains the raw LIBS spectral data for the summarized results described inRush, et. al. 2024

elemental profiling↗

Detection and quantification of trace technetium in the presence of molybdenum using laser-induced breakdown spectroscopy

Technetium (Tc) is a very important element that is encountered in many aspects, from its presence in radioactive waste and its potential environmental impact to its use as a medical radioisotope. Its detection and quantification in liquid samples is traditionally cumbersome, involving detailed sample preparation and analysis by mass spectrometry or scintillation. This article demonstrates the first comprehensive emission spectral analysis of Tc from a liquid sample by immobilization in a polymer and analysis by laser-induced breakdown spectroscopy (LIBS). A survey of LIBS spectra was completed to identify the strongest analytical lines for quantification of trace Tc in the presence of Mo. The quantification of Tc in a Mo-containing matrix was selected because Tc radioisotopes are the daughter products of Mo isotope decay. The first reported calibration curves by LIBS are provided with limits of detection and quantification down to 0.710 µg mL −1 and 1.39 µg mL −1 , respectively. Ultimately, this study demonstrated the feasibility of trace Tc quantification using LIBS and will serve as a reference for future research related to monitoring this radioactive species.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Optimization of laser-induced breakdown spectroscopy for liquid sodium analysis

Next-generation nuclear power reactors based on liquid sodium coolant are in development to improve efficiency and safety. Fast breeder reactors could potentially achieve considerably higher fuel burn-up while producing less nuclear waste compared with current commercial technology. Monitoring of impurities in these types of reactors is important in order to prevent blockage of the cooling system or hazardous reactions due to the high reactivity of sodium with water. In this work, laser-induced breakdown spectroscopy is performed on a liquid sodium sample using a custom-built immersion probe system. The probe provides direct line of sight to the sample vessel in argon atmosphere for laser delivery and signal collection. Signatures of sodium, and impurities such as potassium and oxygen have been obtained. The probe height and immersion have a strong influence on the signal level and stability. Argon flow rates of 2 to 5 liters per minute produce no substantial change in signal, suggesting a steady laminar flowing regime. A high signal-to-noise ratio for impurity elements confirms the suitability of this technique for reliable impurity detection and monitoring in the reactor environment.

Gardette, V. [University of Michigan, Ann Arbor, M↗

Closed-Loop Control of Laser Surface Treatment via Laser Induced Breakdown Spectroscopy

Current composite manufacturing rates need to be improved to meet the projected demand of on-demand mobility (ODM) and commercial aircraft transports. Some processes in the composite manufacturing chain require touch labor such as manual sanding of surfaces prior to bonding and installing thousands of mechanical fasteners in bonded primary structures to achieve Federal Aviation Administration (FAA) certification. The consequences are insufficient repeatability in bond quality resulting in increased manufacturing time. The FAA has indicated that robust process control is one potential means of certifying bondlines in primary structure. This work describes an integrated closed-loop control system between a laser machining system and laser induced breakdown spectroscopy (LIBS) instrumentation as a means of assuring bond performance and achieving certified composite bondlines. Preliminary results from in-situ treatment and inspection are presented. Results indicate that LIBS inspection and laser treatment can be conducted simultaneously to achieve high quality, reliable adhesive bonds.

Rodolfo Ledesma↗

Closed-Loop Control of Laser Surface Treatment via Laser Induced Breakdown Spectroscopy

Current composite manufacturing rates need to be improved to meet the projected demand of on-demand mobility (ODM) and commercial aircraft transports. Some processes in the composite manufacturing chain require touch labor such as manual sanding of surfaces prior to bonding and installing thousands of mechanical fasteners in bonded primary structures to achieve Federal Aviation Administration (FAA) certification. The consequences are insufficient repeatability in bond quality resulting in increased manufacturing time. The FAA has indicated that robust process control is one potential means of certifying bondlines in primary structure. This work describes an integrated closed-loop control system between a laser machining system and laser induced breakdown spectroscopy (LIBS) instrumentation as a means of assuring bond performance and achieving certified composite bondlines. Preliminary results from in-situ treatment and inspection are presented. Results indicate that LIBS inspection and laser treatment can be conducted simultaneously to achieve high quality, reliable adhesive bonds.

Rodolfo Ledesma↗