Efficacy Testing of Biofouling Resistant Materials for Marine Hydrokinetic Technology.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Located on the U.S. Department of Energy's Hanford Site in Richland, Washington, the 200 West Pump and Treat Facility (200 West P and T) has a 9,464 L/min capacity designed to capture and treat an 8 km{sup 2} contaminated groundwater plume. The 200 West P and T system was designed and built by CH2M Hill Plateau Remediation Company to capture and treat contaminated groundwater to reduce the mass of carbon tetrachloride, chromium (trivalent and hexavalent), cyanide, nitrate, and trichloroethene. The system was constructed in calendar years 2010 and 2011 and started operation in 2012. Following treatment, the water is reinjected into the aquifer to serve as a recharge source and to provide flow-path control. Fouling of injection wells has occurred since system startup, characterized by reduced capacity and associated increases in dynamic water level during injection. In severe cases, the water level increases 30.5 m in the first 24 hours of injection. Video inspection of injection wells confirms that the accumulation of solids obstruct the well screens. Because replacement of treated groundwater to the aquifer is essential to the overall remedy, a comprehensive program was initiated to understand the nature/cause of well fouling and to identify mitigation strategies. As a result of this program, a sodium hypochlorite feed system was installed on the pipeline to one injection well to determine whether preventing biological growth would prevent well fouling. A residual of 0.5 to 1.0 mg/L as Cl{sub 2} not only halted fouling but also reversed fouling impacts. Current efforts focus on disinfecting the entire volume of injection water. (authors)
Explore the source record for details and available documents.
Biofouling is difficult to control and hinders the performance of membranes in all applications but is of particular concern when natural waters are purified. Fouling, via multiple mechanisms (organic-only, biofouling-only, cell-deposition-only, and organic + biofouling), of a commercially available membrane (control) and a corresponding membrane coated with an anti-biofouling 2-aminoimidazole (2-AI membrane) was monitored and characterized during the purification of a natural water. Results show that the amount of bacterial cell deposition and organic fouling was not significantly different between control and 2-AI membranes; however, biofilm formation, concurrent or not with other fouling mechanisms, was significantly inhibited (95–98%, p < 0.001) by the 2-AI membrane. The limited biofilm that formed on the 2-AI membrane was weaker (as indicated by the polysaccharide to protein ratio) and thus presumably easier to remove. The conductivity rejection by the 2-AI and control membranes was not significantly different throughout the 75-h experiments, but the rejection of dissolved organic carbon by biofouled (biofouling-only, cell-deposition-only, and organic + biofouling) 2-AI membranes was statistically higher (10–12%, p = 0.003–0.07). When biofouled, the water permeance of the 2-AI membranes decreased significantly less (p < 0.05) over 75 hours than that of the control membranes, whether or not other additional types of fouling occurred concurrently. Despite the initially lower water permeances of 2-AI membranes (11% lower on average than controls), the 2-AI membranes outperformed the controls (10–11% higher average water permeance) after biofilm formation occurred. Overall, 2-AI membranes fouled less than controls without detriment to water productivity and solute rejection.
PNNL has developed a recirculating flume system for exposing braided adsorbent material to natural seawater under realistic temperature and flow-rate exposure conditions. The flumes are constructed of transparent acrylic material; they allow external light to pass into the flumes and permit photosynthetic growth of naturally present marine organisms (biofouling). Because the system consists of two flumes, replicate experiments can be conducted in which one of the flumes can be manipulated relative to the other. For example, one flume can be darkened to eliminate light exposure by placing a black tarp over the flume such that dark/light experiments can be conducted. Alternatively, two different braided adsorbents can be exposed simultaneously with no potential cross contamination issues. This report describes the first use of the PNNL flume system to study the impact of biofouling on adsorbent capacity. Experiments were conducted with the ORNL AI8 braided adsorbent material in light-exposed and darkened flumes for a 42-day exposure experiment. The major objective of this effort is to develop a system for the exposure of braided adsorbent material to unfiltered seawater, and to demonstrate the system by evaluating the performance of adsorption material when it is exposed to natural marine biofouling as it would be when the technology is used in the marine environment. Exposures of amidoxime-based polymeric braid adsorbents prepared by Oak Ridge Natural Laboratory (ORNL) were exposed to ambient seawater at 20°C in a flume system. Adsorption kinetics and adsorption capacity were assessed using time series determinations of uranium adsorption and one-site ligand saturation modeling. Biofouling in sunlight surface seawater has the potential to significantly add substantial biogenic mass to adsorption material when it is exposed for periods greater than 21 days. The observed biomass increase in the light flume was approximately 80% of the adsorbent mass after 42 days. The amount of biomass increase retained by the adsorbent in the dark flume was only a quarter of that observed in the light-exposed flume. Biofouling in sunlit surface seawater has the potential to reduce uranium adsorption capacity by ~30% after 42 days of exposure. Minimal or no adsorption loss due to biofouling occurred in the dark flume exposure. Attempts to assess time series measurements of uranium adsorption capacity using “snips” off a master braid are fraught with problems due to the inability to easily determine the mass of the adsorbent material when the biofouling is present. The ability to determine the adsorption of biogenically important trace elements (e.g. Fe, Mn, Zn, Cu, and Sr) on biofouled adsorbents is also problematic.
Treated municipal wastewater is a common, widely available alternative source of cooling water for thermoelectric power plants across the U.S. However, the biodegradable organic matter, ammonia-nitrogen, carbonate and phosphates in the treated wastewater pose challenges with respect to enhanced biofouling, corrosion, and scaling, respectively. The overall objective of this study was to evaluate the benefits and life cycle costs of implementing tertiary treatment of secondary treated municipal wastewater prior to use in recirculating cooling systems. The study comprised bench- and pilot-scale experimental studies with three different tertiary treated municipal wastewaters, and life cycle costing and environmental analyses of various tertiary treatment schemes. Sustainability factors and metrics for reuse of treated wastewater in power plant cooling systems were also evaluated. The three tertiary treated wastewaters studied were: secondary treated municipal wastewater subjected to acid addition for pH control (MWW_pH); secondary treated municipal wastewater subjected to nitrification and sand filtration (MWW_NF); and secondary treated municipal wastewater subjected nitrification, sand filtration, and GAC adsorption (MWW_NFG). Tertiary treatment was determined to be essential to achieve appropriate corrosion, scaling, and biofouling control for use of secondary treated municipal wastewater in power plant cooling systems. The ability to control scaling, in particular, was found to be significantly enhanced with tertiary treated wastewater compared to secondary treated wastewater. MWW_pH treated water (adjustment to pH 7.8) was effective in reducing scale formation, but increased corrosion and the amount of biocide required to achieve appropriate biofouling control. Corrosion could be adequately controlled with tolytriazole addition (4-5 ppm TTA), however, which was the case for all of the tertiary treated waters. For MWW_NF treated water, the removal of ammonia by nitrification helped to reduce the corrosivity and biocide demand. Also, the lower pH and alkalinity resulting from nitrification reduced the scaling to an acceptable level, without the addition of anti-scalant chemicals. Additional GAC adsorption treatment, MWW_NFG, yielded no net benefit. Removal of organic matter resulted in pitting corrosion in copper and cupronickel alloys. Negligible improvement was observed in scaling control and biofouling control. For all of the tertiary treatments, biofouling control was achievable, and most effectively with pre-formed monochloramine (2-3 ppm) in comparison with NaOCl and ClO2. Life cycle cost (LCC) analyses were performed for the tertiary treatment systems studied experimentally and for several other treatment options. A public domain conceptual costing tool (LC3 model) was developed for this purpose. MWW_SF (lime softening and sand filtration) and MWW_NF were the most cost-effective treatment options among the tertiary treatment alternatives considered because of the higher effluent quality with moderate infrastructure costs and the relatively low doses of conditioning chemicals required. Life cycle inventory (LCI) analysis along with integration of external costs of emissions with direct costs was performed to evaluate relative emissions to the environment and external costs associated with construction and operation of tertiary treatment alternatives. Integrated LCI and LCC analysis indicated that three-tiered treatment alternatives such as MWW_NSF and MWW_NFG, with regular chemical addition for treatment and conditioning and/or regeneration, tend to increase the impact costs and in turn the overall costs of tertiary treatment. River water supply and MWW_F alternatives with a single step of tertiary treatment were associated with lower impact costs, but the contribution of impact costs to overall annual costs was higher than all other treatment alternatives. MWW_NF and MWW_SF alternatives exhibited moderate external impact costs with moderate infrastructure and chemical conditioner dosing, which makes them (especially MWW_NF) better treatment alternatives from the environmental sustainability perspective since they exhibited minimal contribution to environmental damage from emissions.
Uranium from seawater can act as an economic backstop by putting an effective ceiling on the cost of recovering uranium. Although it is not meant to be a direct competitor with conventionally mined uranium there is significant effort, by a consortium of five national labs and ten universities, to improve the recovery process. Accurately predicting the cost associated with this method of uranium production is an important factor in determining a cost ceiling for uranium fuels and assuring supply security for uranium based nuclear fuel cycles. Given the evolving nature of this technology, this paper aims to provide an update of the economic model to reflect recent progress. The recovery system analyzed here is a passive collection process under persistent development by Oak Ridge and Pacific Northwest National Labs (ORNL and PNNL). The process relies on an amidoxime based uranium adsorbents constructed by co-grafting an amidoxime precursor and a hydrophilic comonomer onto a high density polyethylene (HDPE) backbone. After further chemical processing the adsorbent fibers are braided into 60 meter segments. The braids are then sent out to sea where they are moored to the bottom of the ocean. Upon realization of their soaking campaign the braids are winched up so the uranium may be eluted off the adsorbent. The acidic chemicals used in the elution process require an alkaline regeneration procedure to be applied to the adsorbent before it can be redeployed for another campaign. The deployment and elution process is repeated as many times as economically feasible, as dictated by the severity of degradation suffered by the braid due to the elution process and exposure to seawater. A large number of design and deployment parameters influence the final uranium production cost. Some are strongly affected by the chemical technologies, such as uranium uptake and degradation rate, while others are operational parameters, such as number of adsorbent uses and length of soaking campaign. Still others are both intrinsic and affected by operational choices, such as the ocean temperature and degree of oceanic biofouling. Recent experiments have been focused on improved characterization of the effect of: oceanic temperature, a novel elution method, adsorbent degradation rates, and oceanic biofouling, and they will therefore be the focus of this paper. The degradation results presented here are likely to represent a worst case scenario. Since chemically similar adsorbents were able to achieve a much lower degradation rate with the previous acidic elution process it is very possible that modifications can be made to the new adsorbents to ameliorate the degradation suffered, especially with the new bicarbonate elution process, which is believed to be less harsh. Similarly, the 30% loss in uptake suffered as a result of biofouling is likely an upper-bound. The experiments were conducted in full light and at 20 deg. C. In reality however the braids will be submersed approximately 100 meters beneath the surface, potentially subject to a temperature gradient that may influence biofouling patterns. Also the light reaching the adsorbent surface may not be as intense as in laboratory conditions due to seawater turbidity and shadows cast by nearby braids. In light of these factors, it is appropriate to present a range of costs, reflecting the best and worst case scenarios of all of the parameters considered here. Table II shows the updated parameter ranges and uranium production costs. Ongoing work, particularly into the mitigation of biofouling and degradation, is expected to tighten this cost range and reduce the predicted cost. (authors)
The objective of this project was to move the testing of uranium adsorbents from the laboratory to the field. We were successfully able to test fibers in both a flume and ocean environment under varying conditions to quantify the adsorptive properties and uranium uptake of adsorbents under coastal ocean conditions. Through this testing we have identified numerous challenges to be overcome prior to large-scale deployment of these fibers This project began in Phase I with laboratory experiments examining the effects of flow rates and water filtration on the absorption of uranium to fibers in flowthrough columns. In this experiment we found that fibers adsorb most efficiently at a flow rate of 250 ml/min, on a per liter basis. However faster flow rates increase exposure volume and allowed for slightly greater total U absorption. Therefore a balance between current speeds that are too fast and potentially break down fibers and those that are slower will be important to consider, alongside bio-fouling and exposure time, when deciding which current regimes are best to place fibers in the ocean. Phase II examined biofouling, comparing exposure of fibers in filtered flume water to that in a coastal ocean environment. Results from the dock and flume parallel experiment indicate a strong effect of biofouling on the capacity of the adsorbent fibers to adsorb uranium towards the very end of the experiment. Dock and flume samples showed comparable adsorption rates with the flume maximum achieved at day 49 with an adsorbance of 3.4 g U/kg-ads while the dock maximum was reached at day 42 with an adsorbance of 2.7 g U/kg-ads. Biofouling mitigation techniques were also examined. A comparison of 5 m and 12 m samples showed less growth at 12 meters where there is less light as well as less growth on the copper cages, which are toxic to many marine organisms. Overall despite biofouling, particles and other elements present, the fibers adsorbed uranium up to 2.7 g U/kg-ads in our open water dock experiments. This is lower than the maximum achieved in the flume of 3.4 g U/kg-ads and much lower than rates observed with synthetic seawater in laboratory experiments. Phase III involved two parts: working at Woods Hole Oceanographic Institution (WHOI) we examined the feasibility of reusing fibers after ocean deployment. Fiber reuse is an important consideration for operational costs associated with deployment. At present our data implies that reuse after open ocean exposure may not be significantly more effective than a single long deployment of fibers. The second part of Phase III involved collaboration with A. Slocum and M. Haji at MIT to examine the effects of various enclosures for fibers. This also involved testing a rotating system, designed to be deployed as part of an offshore wind turbine.
Omniphobic fluorogel elastomers were prepared by photocuring perfluorinated acrylates and a perfluoropolyether crosslinker. By tuning either the chemical composition or the temperature that control the crystallinity of the resulting polymer chains, a broad range of optical and mechanical properties of the fluorogel can be achieved. After infusing with fluorinated lubricants, the fluorogels showed excellent resistance to wetting by various liquids and anti-biofouling behavior, while maintaining cytocompatiblity.
This technology exploits the organic decomposition capability and hydrophilic properties of the photocatalytic material titanium dioxide (TiO2), a nontoxic and non-hazardous substance, to address contamination and biofouling issues in field-deployed optical sensor systems. Specifically, this technology incorporates TiO2 coatings and materials applied to, or integrated as a part of, the optical surfaces of sensors and calibration sources, including lenses, windows, and mirrors that are used in remote, unattended, ground-based (land or maritime) optical sensor systems. Current methods used to address contamination or biofouling of these optical surfaces in deployed systems are costly, toxic, labor intensive, and non-preventative. By implementing this novel technology, many of these negative aspects can be reduced. The functionality of this innovative self-cleaning solution to address the problem of contamination or biofouling depends on the availability of a sufficient light source with the appropriate spectral properties, which can be attained naturally via sunlight or supplemented using artificial illumination such as UV LEDs (light emitting diodes). In land-based or above-water systems, the TiO2 optical surface is exposed to sunlight, which catalyzes the photocatalytic reaction, facilitating both the decomposition of inorganic and organic compounds, and the activation of superhydrophilic properties. Since underwater optical surfaces are submerged and have limited sunlight exposure, supplementary UV light sources would be required to activate the TiO2 on these optical surfaces. Nighttime operation of land-based or above-water systems would require this addition as well. For most superhydrophilic self-cleaning purposes, a rainwater wash will suffice; however, for some applications an attached rainwater collector/ dispenser or other fresh water dispensing system may be required to wash the optical surface and initiate the removal of contaminates. Deployment of this non-toxic,non-hazardous-technology will take advantage of environmental elements (i.e. rain and sunlight), increase the longevity of unattended optical systems, increase the amount of time between required maintenance, and improve the long-term accuracy of sensor measurements.
Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results were compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.