Systematic Review of Life Cycle Greenhouse Gas Emissions from Geothermal Electricity

The primary goal of this work was to assess the magnitude and variability of published life cycle greenhouse gas (GHG) emission estimates for three types of geothermal electricity generation technologies: enhanced geothermal systems (EGS) binary, hydrothermal (HT) flash, and HT binary. These technologies were chosen to align the results of this report with technologies modeled in National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment Systems (ReEDs) model. Although we did gather and screen life cycle assessment (LCA) literature on hybrid systems, dry steam, and two geothermal heating technologies, we did not analyze published GHG emission estimates for these technologies. In our systematic literature review of the LCA literature, we screened studies in two stages based on a variety of criteria adapted from NREL's Life Cycle Assessment (LCA) Harmonization study (Heath and Mann 2012). Of the more than 180 geothermal studies identified, only 29 successfully passed both screening stages and only 26 of these included estimates of life cycle GHG emissions. We found that the median estimate of life cycle GHG emissions (in grams of carbon dioxide equivalent per kilowatt-hour generated [g CO2eq/kWh]) reported by these studies are 32.0, 47.0, and 11.3 for EGS binary, HT flash, and HT binary, respectively (Figure ES-1). We also found that the total life cycle GHG emissions are dominated by different stages of the life cycle for different technologies. For example, the GHG emissions from HT flash plants are dominated by the operations phase owing to the flash cycle being open loop whereby carbon dioxide entrained in the geothermal fluids is released to the atmosphere. This is in contrast to binary plants (using either EGS or HT resources), whose GHG emissions predominantly originate in the construction phase, owing to its closed-loop process design. Finally, by comparing this review's literature-derived range of HT flash GHG emissions to data from currently operating geothermal plants, we found that emissions from operational plants exhibit more variability and the median of emissions from operational plants is twice the median of operational emissions reported by LCAs. Further investigation is warranted to better understand the cause of differences between published LCAs and estimates from operational plants and to develop LCA analytical approaches that can yield estimates closer to actual emissions.

15 GEOTHERMAL ENERGY↗

DOE-GTO Low Temperature Project Case Study

The US Department of Energy (DOE), Geothermal Technologies Office (GTO) has funded low temperature projects to demonstrate the technical and economic feasibility of power generation from geothermal resources at temperatures of 150°C and lower. To date three of the funded projects have completed their two year operation phase during which they supplied operating data to the GTO. This paper discusses the operation of two of these plants while they were providing data, including a review of facility performance, as well as an initial economic assessment of each.

15 GEOTHERMAL ENERGY↗

Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Production and Injection data for NV Binary facilities

Excel files are provided with well production and injection data for binary facilities in Nevada. The files contain the data that reported montly to the Nevada Bureau of Mines and Geology (NBMG) by the facility operators. this data has been complied into Excel spreadsheets for each of the facilities given on the NBMG web site.

15 GEOTHERMAL ENERGY↗

Experimental and Computational Investigation of High Entropy Alloys for Elevated-Temperature Applications

To create and design novel structural materials with enhanced creep-resistance, fundamental studies have been conducted on high-entropy alloys (HEAs), using (1) thermodynamic calculations, (2) mechanical tests, (3) neutron diffraction, (4) characterization techniques, and (5) crystal-plasticity finite-element modeling (CPFEM), to explore future candidates for next-generation power plants. All the constituent binary and ternary systems of the Al-Cr-Cu-Fe-Mn-Ni and Al-Co-Cr-Fe-Ni systems were thermodynamically modeled within the whole composition range. Comparisons between the calculated phase diagrams and literature data are in good agreement. Seven types of HEAs were fabricated from Al-Cr-Cu-Fe-Mn-Ni and Al-Co-Cr-Fe-Ni systems. The Al x CrCuFeMnNi HEAs have disordered [face-centered cubic (FCC) + body-centered cubic (BCC)] crystal structures, not FCC or BCC single structure. Excessive alloying of the Al element results in the change of both microstructural and mechanical properties in Al x CoCrFeNi HEAs. There are mainly three structural features in Al x CoCrFeNi: (1) the morphology, (2) the volume fractions of the constitute phases, and (3) existing temperatures of all six phases. After homogenization, the Al 0.3 CoCrFeNi material is a pure FCC solid solution. After aging at 700 °C for 500 hours, the optimal microstructure combinations, the FCC matrix, needle-like B2 phase within grains, and granular σ phase along grain boundary, is achieved for Al 0.3 CoCrFeNi. The cold-rolling process is utilized to reduce the grain size of Al 0.1 CoCrFeNi and Al 0.3 CoCrFeNi. The chemical elemental partitioning of FCC, BCC, B2, and σphases at different temperatures, before and after mechanical tests, in Al-Cr-Cu-Fe-Mn-Ni and Al-Co-Cr-Fe-Ni systems are quantitatively characterized by both synchrotron X-ray diffraction, neutron diffraction with levitation, scanning electron microscopy (SEM), advanced atom probe tomography (APT), and transmission electron microscopy (TEM). In-situ neutron diffraction experiments were conducted to study the strengthening effect of B2 phase on tensile properties of Al 0.3 CoCrFeNi HEAs directly. The results shows the creep behavior of Al 0.3 CoCrFeNi is superior to conventional alloys, and the heat treatment introduces secondary B2 phase into the FCC matrix, which increase the yielding strength, decrease the ductility, diminish the serrated flow during compression tests at high temperatures. In summary, the outcomes of the development of the HEAs with creep resistance include: (1) Suitable candidates, for the application to boilers and steam and gas turbines at temperatures above 760 °C and a stress of 35 MPa. (2) Fundamental understanding on the precipitate stability and deformation mechanisms of both single-phase and precipitate-strengthened alloys at room and elevated temperatures, and (3) The demonstration of an integrated approach, coupling modeling [thermodynamic calculations and crystal-plasticity finite-element modeling (CPFEM)] and focused experiments, to identify HEAs that outperform conventional alloys for high-temperature applications, which will be applicable for the discovery and development of other high-temperature materials in the power-generating industry.

36 MATERIALS SCIENCE↗

Energy 101 Geothermal [Slides]

The Energy 101: Geothermal presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of geothermal energy. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

15 GEOTHERMAL ENERGY↗

Discovery and analysis of a blind geothermal system in southeastern Gabbs Valley, Western Nevada

This study assessed the potential for high-temperature (≥130°C) blind geothermal systems in southeastern Gabbs Valley by employing a geothermal play fairway analysis approach involving integration of geologic, geophysical, and geochemical datasets. Gabbs Valley is a complex, tectonically active basin within the Great Basin on the boundary between the transtensional central Walker Lane domain and extensional Basin and Range province. The termination of the Petrified Springs fault, a major dextral fault of the central Walker Lane, in an array of normal faults indicates that southeastern Gabbs Valley occupies a displacement transfer zone, which is a favorable structural setting for geothermal activity. The displacement transfer zone is a structurally complicated area with many faults of varying geometries, kinematics, and ages. A substantial northwest-trending gravity high within the south-central part of southeastern Gabbs Valley is produced from offsets along concealed northwest-striking dextral-normal faults that intersect strands of north-northeast-to east-northeast-striking normal faults. This area of tightly spaced faults and fault intersections is a particularly favorable structural setting within the broader-scale displacement transfer zone. Multiple lines of direct and indirect evidence suggest the presence of a relatively high-temperature (≥130°C) blind geothermal system in this area, including collocated intersecting gravity gradients, magnetic-low, low-resistivity, and 2-m temperature anomaly. Potentially related, water samples from agricultural wells ~7 km northwest of the 2-m anomaly yield geothermometers indicating subsurface fluid temperatures of 130-140°C. Six temperature-gradient holes were drilled to target the extent of the shallow-temperature and geophysical anomalies to define the geothermal system in southeastern Gabbs Valley. Two wells contained high temperatures exceeding boiling with bottom-hole temperatures ii of 114.5°C and 124.9°C, respectively, and the remaining wells displayed elevated to background temperatures ranging from 79.2°C to 28.7°C. The observed temperature gradients for the two hottest drill holes necessitate drill-hole intercepts of convecting hydrothermal fluids. The 2-m survey is spatially and thermally consistent with the temperature-gradient holes and constrains the core of upflow at a shallow depth interval (<250m) to an area <0.5-1 km west-southwest of the hottest drill hole. The zone of inferred upwelling occupies the area corresponding to the center of the magnetic-low. This project has several significant implications. The newly discovered blind geothermal system in southeastern Gabbs Valley may be capable of supporting a binary-type geothermal power plant. This detailed study provides an initial validation of the play fairway approach to geothermal exploration. It also demonstrates both the broad applicability of the play fairway exploration strategy and the large untapped potential for commercial-grade blind geothermal systems in many of the basins in the Great Basin region.

15 GEOTHERMAL ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Auxin-Producing Bacteria from Duckweeds Have Different Colonization Patterns and Effects on Plant Morphology

The role of auxin in plant–microbe interaction has primarily been studied using indole-3-acetic acid (IAA)-producing pathogenic or plant-growth-promoting bacteria. However, the IAA biosynthesis pathway in bacteria involves indole-related compounds (IRCs) and intermediates with less known functions. Here, we seek to understand changes in plant response to multiple plant-associated bacteria taxa and strains that differ in their ability to produce IRCs. We had previously studied 47 bacterial strains isolated from several duckweed species and determined that 79% of these strains produced IRCs in culture, such as IAA, indole lactic acid (ILA), and indole. Using Arabidopsis thaliana as our model plant with excellent genetic tools, we performed binary association assays on a subset of these strains to evaluate morphological responses in the plant host and the mode of bacterial colonization. Of the 21 tested strains, only four high-quantity IAA-producing Microbacterium strains caused an auxin root phenotype. Compared to the commonly used colorimetric Salkowski assay, auxin concentration determined by LC–MS was a superior indicator of a bacteria’s ability to cause an auxin root phenotype. Studies with the auxin response mutant axr1-3 provided further genetic support for the role of auxin signaling in mediating the root morphology response to IAA-producing bacteria strains. Interestingly, our microscopy results also revealed new evidence for the role of the conserved AXR1 gene in endophytic colonization of IAA-producing Azospirillum baldaniorum Sp245 via the guard cells.

59 BASIC BIOLOGICAL SCIENCES↗

A Novel Gene Stacking Method in Plant Transformation Utilizing Split Selectable Markers

Gene stacking, the process of introducing multiple genes into a single plant to enhance desired traits, is essential for plant genetic improvement through both conventional breeding and genetic transformation. In general, transformation-based gene stacking can be achieved through either co-transformation to simultaneously introduce multiple genes or sequential multi-round transformation. While co-transformation is generally faster and more efficient than sequential multi-round transformation, it often requires two selectable marker genes, which confer resistance to antibiotics, for selecting transgenic events. However, in most cases, there is only one best selectable marker gene for a specific plant species or genotype. Also, it is harder to optimize the concentrations of two antibiotics for co-transformation than using one antibiotic for selecting transgenic events. To overcome this challenge, we recently developed an innovative split selectable marker system for plant co-transformation, allowing the use of one selectable marker gene to select transgenic events. This method involves constructing two binary vectors, each carrying a subset of genes of interest and a partial fragment of the selectable marker gene, which is connected to a partial intein fragment. Following Agrobacterium -mediated co-transformation, plants harboring both binary vectors are selected using a single antibiotic, such as kanamycin. This split-marker system can be used to co-transform multiple genes into both herbaceous and woody plants, accelerating genetic improvement of polygenic traits or integrative improvement of multiple traits to simultaneously increase crop yield and quality.

59 BASIC BIOLOGICAL SCIENCES↗

An optimization model for collection, haul, transfer, treatment and disposal of infectious medical waste: Application to a Greek region

Highlights: • We developed an optimization model to minimize cost of infectious waste management. •Two different software were used for model solution. • Model optimizes locations and capacities of treatment plants and transfer stations. • The higher percentage of total cost was due to construction of the treatment plant. • Sensitivity analysis with respect to fuel cost and waste production was conducted. - Abstract: The objective of this work was to develop an optimization model to minimize the cost of a collection, haul, transfer, treatment and disposal system for infectious medical waste (IMW). The model calculates the optimum locations of the treatment facilities and transfer stations, their design capacities (t/d), the number and capacities of all waste collection, transport and transfer vehicles and their optimum transport path and the minimum IMW management system cost. Waste production nodes (hospitals, healthcare centers, peripheral health offices, private clinics and physicians in private practice) and their IMW production rates were specified and used as model inputs. The candidate locations of the treatment facilities, transfer stations and sanitary landfills were designated, using a GIS-based methodology. Specifically, Mapinfo software with exclusion criteria for non-appropriate areas was used for siting candidate locations for the construction of the treatment plant and calculating the distance and travel time of all possible vehicle routes. The objective function was a non-linear equation, which minimized the total collection, transport, treatment and disposal cost. Total cost comprised capital and operation costs for: (1) treatment plant, (2) waste transfer stations, (3) waste transport and transfer vehicles and (4) waste collection bins and hospital boxes. Binary variables were used to decide whether a treatment plant and/or a transfer station should be constructed and whether a collection route between two or more nodes should be followed. Microsoft excel software was used as installation platform of the optimization model. For the execution of the optimization routine, two completely different software were used and the results were compared, thus, resulting in higher reliability and validity of the results. The first software was Evolver, which is based on the use of genetic algorithms. The second one was Crystal Ball, which is based on Monte Carlo simulation. The model was applied to the Region of East Macedonia – Thrace in Greece. The optimum solution resulted in one treatment plant located in the sanitary landfill area of Chrysoupolis, required no transfer stations and had a total management cost of 38,800 €/month or 809 €/t. If a treatment plant is sited in the most eastern part of the Region, i.e., the industrial area of Alexandroupolis, the optimum solution would result in a transfer station of 23 m{sup 3}, located near Kavala General Hospital, and a total cost of 39,800 €/month or 831 €/t. A sensitivity analysis was conducted and two alternative scenarios were optimized. In the first scenario, a 15% rise in fuel cost and in the second scenario a 25% rise in IMW production were considered. At the end, a cost calculation in €/t/km for every type of vehicle used for haul and transfer was conducted. Also, the cost of the whole system was itemized and calculated in €/t/km and €/t. The results showed that the higher percentage of the total cost was due to the construction of the treatment plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Depleted and enriched uranium exposure quantified in former factory workers and local residents of NL Industries, Colonie, NY USA

Background: Between 1958 and 1982, NL Industries manufactured components of enriched (EU) and depleted uranium (DU) at a factory in Colonie NY, USA. More than 5 metric tons of DU was deposited as microscopic DU oxide particles on the plant site and surrounding residential community. A prior study involving a small number of individuals (n=23) indicated some residents were exposed to DU and former workers to both DU and EU, most probably through inhalation of aerosol particles. Objectives: Our aim was to measure total uranium [U] and the uranium isotope ratios: {sup 234}U/{sup 238}U; {sup 235}U/{sup 238}U; and {sup 236}U/{sup 238}U, in the urine of a cohort of former workers and nearby residents of the NLI factory, to characterize individual exposure to natural uranium (NU), DU, and EU more than 3 decades after production ceased. Methods: We conducted a biomonitoring study in a larger cohort of 32 former workers and 99 residents, who may have been exposed during its period of operation, by measuring Total U, NU, DU, and EU in urine using Sector Field Inductively Coupled Plasma - Mass Spectrometry (SF-ICP-MS). Results: Among workers, 84% were exposed to DU, 9% to EU and DU, and 6% to natural uranium (NU) only. For those exposed to DU, urinary isotopic and [U] compositions result from binary mixing of NU and the DU plant feedstock. Among residents, 8% show evidence of DU exposure, whereas none shows evidence of EU exposure. For residents, the [U] geometric mean is significantly below the value reported for NHANES. There is no significant difference in [U] between exposed and unexposed residents, suggesting that [U] alone is not a reliable indicator of exposure to DU in this group. Conclusions: Ninety four percent of workers tested showed evidence of exposure to DU, EU or both, and were still excreting DU and EU decades after leaving the workforce. The study demonstrates the advantage of measuring multiple isotopic ratios (e.g., {sup 236}U/{sup 238}U and {sup 235}U/{sup 238}U) over a single ratio ({sup 235}U/{sup 238}U) in determining sources of uranium exposure. - Highlights: • Biomonitoring study of residents and former workers exposed to DU in Colonie NY. • Urine (99 residents+32 former workers) analyzed for depleted uranium (DU). • DU detected in 84% of workers and 8% of residents >30 years after plant closed. • Enriched uranium detected in 6% of former workers based on isotope ratios.

54 ENVIRONMENTAL SCIENCES↗

Summary of Historical Production for Nevada Binary Facilities

The analysis described was initiated to validate inputs used in the US Department of Energy’s (DOE) economic modeling tool GETEM (Geothermal Electricity Technology Evaluation Model) by using publically available data to identify production trends at operating geothermal binary facilities in the state of Nevada. Data required for this analysis was obtained from the Nevada Bureau of Mines and Geology (NBMG), whom received the original operator reports from the Nevada Division of Minerals (NDOM). The data from the NBMG was inputted into Excel files that have been uploaded to the DOE’s National Geothermal Data System (NGDS). Once data was available in an Excel format, production trends for individual wells and facilities could be established for the periods data was available (thru 2009). Additionally, this analysis identified relationships existing between production (temperature and flow rates), power production and plant conversion efficiencies. The data trends showed that temperature declines have a significant impact on power production, and that in some instances operators increased production flow rate to offset power declines. The production trends with time that were identified are being used to update GETEM’s default inputs.

15 GEOTHERMAL ENERGY↗

MultiGreen: A multiplexing architecture for GreenGate cloning

Genetic modification of plants fundamentally relies upon customized vector designs. The ever-increasing complexity of transgenic constructs has led to increased adoption of modular cloning systems for their ease of use, cost effectiveness, and rapid prototyping. GreenGate is a modular cloning system catered specifically to designing bespoke, single transcriptional unit vectors for plant transformation—which is also its greatest flaw. MultiGreen seeks to address GreenGate’s limitations while maintaining the syntax of the original GreenGate kit. The primary limitations MultiGreen addresses are 1) multiplexing in series, 2) multiplexing in parallel, and 3) repeated cycling of transcriptional unit assembly through binary intermediates. MultiGreen efficiently concatenates bespoke transcriptional units using an additional suite of level 1acceptor vectors which serve as an assembly point for individual transcriptional units prior to final, level 2, condensation of multiple transcriptional units. Assembly with MultiGreen level 1 vectors scales at a maximal rate of 2*⌈ log 6 n ⌉+3 days per assembly, where n represents the number of transcriptional units. Further, MultiGreen level 1 acceptor vectors are binary vectors and can be used directly for plant transformation to further maximize prototyping speed. MultiGreen is a 1:1 expansion of the original GreenGate architecture’s grammar and has been demonstrated to efficiently assemble plasmids with multiple transcriptional units. MultiGreen has been validated by using a truncated violacein operon from Chromobacterium violaceum in bacteria and by deconstructing the RUBY reporter for in planta functional validation. MultiGreen currently supports many of our in-house multi transcriptional unit assemblies and will be a valuable strategy for more complex cloning projects.

Science & Technology - Other Topics↗

Computational fluid dynamics simulations of a binary particle bed in a riser-based carbon stripper for chemical looping combustion

Chemical-looping combustion (CLC) is a next generation combustion technology that shows great promise as a solution for the need of high-efficiency low-cost carbon capture from fossil fueled power plants. In this paper, numerical simulations are conducted of a binary particle bed associated with a coal-direct CLC system consisting of coal (represented by plastic beads) and oxygen carrier particles and validated against an experimental riser-based carbon stripper. The detailed particle dynamics and solid-gas and solid-solid interactions are investigated using the Lagrangian particle-tracking approach known as the discrete element method coupled with the computational fluid dynamics solution for the flow field. The simulation results of the fluidization behavior and the separation ratio of the particles are in excellent agreement with the experiment. In conclusion, a credible simulation of a binary particle bed is of particular importance for understanding the details of the fluidization behavior; the baseline simulation established in this work can be used as a tool for designing and optimizing the performance of such systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗