Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beta counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Beta-Adrenergic Blockade Does not Prevent Polycythemia or Decrease in Plasma Volume in Men at 4300 m Altitude

When humans ascend to high altitude (ALT) their plasma volume (PV) and total blood volume (BV) decrease during the first few days. With continued residence over several weeks, the hypoxia-induced stimulation of erythropoietin increases red cell production which tends to restore BV. Because hypoxia also activates the beta-adrenergic system, which stimulates red blood cell production, we investigated the effect of adrenergic beta-receptor inhibition with propranolol on fluid volumes and the polycythemic response in 11 healthy unacclimatized men (21-33 years old exposed to an ALT of 4300 m (barometric pressure 460 Torr) for 3 weeks on Pikes Peak, Colorado. PV was determined by the Evans blue dye method (PV(sub EB)), BV by the carbon monoxide method (BV(sub CO)), red cell volume (RCV)was calculated from hematocrit (Hct) and BV(sub CO), and serum erythropoietin concentration ([EPO]) and reticulocyte count, were also determined. All determinations were made at sea level and after 9-11 (ALT-10) and 9-20 (ALT-20) days at ALT. At sea level and ALT, six men received propranolol (pro, 240 mg/day), and five received a placebo (pla). Effective beta-blockade did not modify the mean (SE) maximal values of [EPO] [pla: 24.9 (3.5) vs pro: 24.5 (1.5) mU/ml] or reticulocyte count [pla: 2.7 (0.7) vs pro: 2.2 (0.5)%]; nor changes in PV(sub EB)[pla: -15.8 (3.8) vs pro: -19.9 (2.8)%], RCV(sub CO) [pla: +7.0 (6.7) vs pro: +10.1 (6.1)%], or BV(sub CO) [pla: -7.3 (2.3) vs pro: -7.1 (3.9)%]. In the absence of weight loss, a redistribution of body water with no net loss is implied. Hence, activation of the beta-adrenergic system did not appear to affect the hypovolemic or polycythemic responses that occurred during 3 weeks at 4300 m ALT in these subjects.

Grover, R. F.↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

2 νββ spectrum in chiral effective field theory

We investigate two-neutrino double beta decay (2νββ) in chiral effective field theory. We find contributions from weak magnetism and double-weak pion-exchange at next-to-leading-order in the chiral power counting. We discuss the impact of the chiral corrections on the electron spectra and find that they should be included in analyses of 2νββ decay that aim to uncover new physics signatures in the electron spectrum. We illustrate this point by revisiting the effect of sterile neutrinos and non-standard charged interactions. We also find that the pion-exchange contributions involve nuclear matrix elements that are related to those appearing in neutrinoless double beta decay (0νββ). We investigate whether the 0νββ nuclear matrix elements can be obtained from detailed measurements of the energy spectrum of the outgoing electrons in 2νββ transitions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectra of solar proton ground level events using neutron monitor and neutron moderated detector recordings

Recordings on relativistic solar flare protons observed at Sanae, Antarctic, show that the percentage increase in counting rates of the neutron moderated detector (4NMD) is larger than the percentage increase in counting rates of the 3NM64 neutron monitor. These relative increases are described by solar proton differential spectra j sub s(P) = AP(beta). The power beta is determined for each event and the hardnesses of the temporal variations of beta, found for the ground level events (GLE) of 7 May, 1978 and 22 November, 1977.

Stoker, P. H.↗

Recalibrated Equations for Determining Effect of Oil Filtration on Rolling Bearing Life

In 1991, Needelman and Zaretsky presented a set of empirically derived equations for bearing fatigue life (adjustment) factors (LFs) as a function of oil filter ratings. These equations for life factors were incorporated into the reference book, "STLE Life Factors for Rolling Bearings." These equations were normalized (LF = 1) to a 10-micrometer filter rating at Beta(sub x) = 200 (normal cleanliness) as it was then defined. Over the past 20 years, these life factors based on oil filtration have been used in conjunction with ANSI/ABMA standards and bearing computer codes to predict rolling bearing life. Also, additional experimental studies have been made by other investigators into the relationship between rolling bearing life and the size, number, and type of particle contamination. During this time period filter ratings have also been revised and improved, and they now use particle counting calibrated to a new National Institute of Standards and Technology (NIST) reference material, NIST SRM 2806, 1997. This paper reviews the relevant bearing life studies and describes the new filter ratings. New filter ratings, Beta(sub x(c)) = 200 and Beta(sub x(c)) = 1000, are benchmarked to old filter ratings, Beta(sub x) = 200, and vice versa. Two separate sets of filter LF values were derived based on the new filter ratings for roller bearings and ball bearings, respectively. Filter LFs can be calculated for the new filter ratings.

Needelman, William M.↗

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.↗

Hematological and TGF-beta variations after whole-body proton irradiation

The acute effects of proton whole-body irradiation on five bone-marrow-derived cell types and transforming growth factor-beta 1 (TGF-beta 1) were examined and compared to the effects of photons (60Co). C57BL/6 mice were exposed to 3 Gy (0.4 Gy/min) protons at spread-out Bragg peak (SOBP), protons at entry (E), or 60Co and euthanized on days 0.5-17 thereafter. 60Co-irradiated animals had decreased erythrocytes, hemoglobin and hematocrit at 12 hours post-exposure; depression was not noted in proton (SOBP or E)-irradiated groups until day 4. Significantly decreased leukocyte counts were observed at this same time in all irradiated groups, with lymphocyte loss being greater than that of monocytes, and the depression was generally maintained. In contrast, the levels of neutrophils and thrombocytes fluctuated, especially during the first week; significant differences were noted among irradiated groups in neutrophil levels. Plasma TGF-beta 1 was elevated on day 7 in the 60Co, but not proton, irradiated mice. Collectively, the data show that dramatic and persistent changes occurred in all irradiated groups. However, few differences in assay results were seen between animals exposed to protons (SOBP or E) or photons, as well as between the groups irradiated with either of the two regions of the proton Bragg curve.

Non-NASA Center↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗

Long-term modulation of galactic cosmic radiation and its model for space exploration

As the human exploration of space has received new attention in the United States, studies find that exposure to space radiation could adversely impact the mission design. Galactic Cosmic Radiation (GCR), with its very wide range of charges and energies, is particularly important for a mission to Mars, because it imposes a stiff mass penalty for spacecraft shielding. Dose equivalent versus shielding thickness calculations, show a rapid initial drop on exposure with thickness, but an asymptotic behavior at a higher shielding thickness. Uncertainties in the radiobiology are largely unknown. For a fixed radiation risk, this leads to large uncertainties in shielding thickness for small uncertainties in estimated dose. In this paper we investigate the application of steady-state, spherically-symmetric diffusion-convection theory of solar modulation to individual measurements of differential energy spectra from 1954 to 1989 in order to estimate the diffusion coefficient, kappa(r,t), as a function of time. We have correlated the diffusion coefficient to the Climax neutron monitor rates and show that, if the diffusion coefficient can be separated into independent functions of space and time: kappa(r,t)=K(t) k(sub 0) beta Pk(sub 1) (r), where beta is the particle velocity and P the rigidity, then (i) The time dependent quantity 1/K(t), which is proportional to the deceleration potential, phi(r,t), is linearly related to the Climax neutron monitor counting rate. (ii) The coefficients obtained from hydrogen or helium intensity measurements are the same. (iii) There are different correlation functions for odd and even solar cycles. (iv) The correlation function for the Climax neutron monitor counting rate for given time, t, can be used to estimate mean deceleration parameter phi(t) to within +/- 15% with 90% confidence. We have shown that k(r,t) determined from hydrogen and/or helium data, can be used to fit the oxygen and iron differential energy spectra with a root mean square error of about +/- 10%, and essentially independent of the particle charge or energy. We have also examined the ion chamber and C-14 measurements which allow the analysis to be extended from the year 1906 to 1990. Using this model we have defined reference GCR spectra at solar minimum and solar maximum. These can be used for space exploration studies and provide a quantitative estimate of the error in dose due to changes in GCR intensities.

Badhwan, G. D.↗

Diabetes and hypertension are related to amyloid-beta burden in the population-based Rotterdam Study

Abstract Higher vascular disease burden increases the likelihood of developing dementia, including Alzheimer’s disease. Better understanding the association between vascular risk factors and Alzheimer’s disease pathology at the predementia stage is critical for developing effective strategies to delay cognitive decline. In this work, we estimated the impact of six vascular risk factors on the presence and severity of in vivo measured brain amyloid-beta (Aβ) plaques in participants from the population-based Rotterdam Study. Vascular risk factors (hypertension, hypercholesterolaemia, diabetes, obesity, physical inactivity and smoking) were assessed 13 (2004–2008) and 7 years (2009–2014) prior to 18F-florbetaben PET (2018–2021) in 635 dementia-free participants. Vascular risk factors were associated with binary amyloid PET status or continuous PET readouts (standard uptake value ratios, SUVrs) using logistic and linear regression models, respectively, adjusted for age, sex, education, APOE4 risk allele count and time between vascular risk and PET assessment. Participants’ mean age at time of amyloid PET was 69 years (range: 60–90), 325 (51.2%) were women and 190 (29.9%) carried at least one APOE4 risk allele. The adjusted prevalence estimates of an amyloid-positive PET status markedly increased with age [12.8% (95% CI 11.6; 14) in 60–69 years versus 35% (36; 40.8) in 80–89 years age groups] and APOE4 allele count [9.7% (8.8; 10.6) in non-carriers versus 38.4% (36; 40.8) to 60.4% (54; 66.8) in carriers of one or two risk allele(s)]. Diabetes 7 years prior to PET assessment was associated with a higher risk of a positive amyloid status [odds ratio (95% CI) = 3.68 (1.76; 7.61), P < 0.001] and higher standard uptake value ratios, indicating more severe Aβ pathology [standardized beta = 0.40 (0.17; 0.64), P = 0.001]. Hypertension was associated with higher SUVr values in APOE4 carriers (mean SUVr difference of 0.09), but not in non-carriers (mean SUVr difference 0.02; P = 0.005). In contrast, hypercholesterolaemia was related to lower SUVr values in APOE4 carriers (mean SUVr difference −0.06), but not in non-carriers (mean SUVr difference 0.02). Obesity, physical inactivity and smoking were not related to amyloid PET measures. The current findings suggest a contribution of diabetes, hypertension and hypercholesterolaemia to the pathophysiology of Alzheimer’s disease in a general population of older non-demented adults. As these conditions respond well to lifestyle modification and drug treatment, further research should focus on the preventative effect of early risk management on the development of Alzheimer’s disease neuropathology.

van Arendonk, Joyce (ORCID:0000000172941633)↗

Cell contact as an independent factor modulating cardiac myocyte hypertrophy and survival in long-term primary culture

Cardiac myocytes maintained in cell culture develop hypertrophy both in response to mechanical loading as well as to receptor-mediated signaling mechanisms. However, it has been shown that the hypertrophic response to these stimuli may be modulated through effects of intercellular contact achieved by maintaining cells at different plating densities. In this study, we show that the myocyte plating density affects not only the hypertrophic response and features of the differentiated phenotype of isolated adult myocytes, but also plays a significant role influencing myocyte survival in vitro. The native rod-shaped phenotype of freshly isolated adult myocytes persists in an environment which minimizes myocyte attachment and spreading on the substratum. However, these conditions are not optimal for long-term maintenance of cultured adult cardiac myocytes. Conditions which promote myocyte attachment and spreading on the substratum, on the other hand, also promote the re-establishment of new intercellular contacts between myocytes. These contacts appear to play a significant role in the development of spontaneous activity, which enhances the redevelopment of highly differentiated contractile, junctional, and sarcoplasmic reticulum structures in the cultured adult cardiomyocyte. Although it has previously been shown that adult cardiac myocytes are typically quiescent in culture, the addition of beta-adrenergic agonists stimulates beating and myocyte hypertrophy, and thereby serves to increase the level of intercellular contact as well. However, in densely-plated cultures with intrinsically high levels of intercellular contact, spontaneous contractile activity develops without the addition of beta-adrenergic agonists. In this study, we compare the function, morphology, and natural history of adult feline cardiomyocytes which have been maintained in cultures with different levels of intercellular contact, with and without the addition of beta-adrenergic agonists. Intercellular contact, communication, and transmission of contractile forces between myocytes appears to play a primary role in remodeling the 2-dimensional cell layer into a parallel alignment of elongated myocytes with highly developed intercalated disk-like junctions. This highly differentiated state is very stable, and cultures which achieve this state exhibit significantly greater longevity than more sparsely plated myocytes. These myocytes typically continue beating, and survive from 6 to more than 12 weeks in culture. When this level of contact and differentiation are not achieved, even among beta-adrenergic stimulated myocytes, contractile activity is not sustained, myofibrils atrophy, there is little or no development of junctional complexes, and the period of myocyte viability is typically no more than 5 weeks in vitro.

Non-NASA Center↗

Rapid Monitoring of Bacteria and Fungi aboard the International Space Station (ISS)

Microorganisms within spacecraft have traditionally been monitored with culture-based techniques. These techniques involve growth of environmental samples (cabin water, air or surfaces) on agar-type media for several days, followed by visualization of resulting colonies or return of samples to Earth for ground-based analysis. Data obtained over the past 4 decades have enhanced our understanding of the microbial ecology within space stations. However, the approach has been limited by the following factors: i) Many microorganisms (estimated > 95%) in the environment cannot grow on conventional growth media; ii) Significant time lags (3-5 days for incubation and up to several months to return samples to ground); iii) Condensation in contact slides hinders colony counting by crew; and iv) Growth of potentially harmful microorganisms, which must then be disposed of safely. This report describes the operation of a new culture-independent technique onboard the ISS for rapid analysis (within minutes) of endotoxin and beta-1, 3-glucan, found in the cell walls of gramnegative bacteria and fungi, respectively. The technique involves analysis of environmental samples with the Limulus Amebocyte Lysate (LAL) assay in a handheld device, known as the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS). LOCADPTS was launched to the ISS in December 2006, and here we present data obtained from Mach 2007 until the present day. These data include a comparative study between LOCADPTS analysis and existing culture-based methods; and an exploratory survey of surface endotoxin and beta-1, 3-glucan throughout the ISS. While a general correlation between LOCAD-PTS and traditional culture-based methods should not be expected, we will suggest new requirements for microbial monitoring based upon culture-independent parameters measured by LOCAD-PTS.

Gunter, D.↗

Using Beta Cen to Probe the Photosphere-wind Connection in B Stars

In this project we began by identifying the large number of emission lines visible in the XMM-Newton RGS spectra of Beta Cen. A comprehensive analysis of the temperature structure of the hot gas was carried out by simultaneously fitting the data from all the instruments on the spacecraft. This resulted in a measured temperature range of 0.1-0.6 keV. In more detailed analysis, three characteristic plasma temperatures were found: 0.1, 0.2, and 0.6 keV. The research carried out at UW-Eau Claire primarily focused on two aspects of the data: the analysis of the forbidden line to intercombination line ratio for He-like ions and the time variability of the overall X-ray flux as detected in the direct X-ray images of the star. The analysis of the lines from He-like ions indicate that the Ne IX lines are formed no farther than about 4 stellar radii from the star's photosphere, while the N VI lines are formed within 11 stellar radii of the photosphere. X-ray flux variability would be particularly interesting for this star because it is a known Beta Cep-type variable as seen in optical light: similar variation in the X-ray region would forge an interesting link between the two wavebands. Initial analysis of the X-ray flux was complicated by spikes in the count rates early in the observation. Detailed analysis of the spectral characteristics these count rate anomalies indicated that these flares were probably not intrinsic to the star, rather they were contaminations of the data due to the passage of the satellite through soft proton clouds in the Earth's magnetosphere. An analysis of the light curve of the uncontaminated portions of the light curve did not reveal any variation on the known optical period of variation for this star, and a general search for periodic variability also did not find any significant periods of variation.

Miller, Nathan A.↗

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.↗

Evidence for a cytokine-sensitive network of iron-associated genes that protects pancreatic islets against ferroptosis

Background/Objectives: The micronutrient iron is closely connected to inflammation and is among the complex factors contributing to beta-cell failure in diabetes. High levels of dietary iron increase the risk of developing type 2 diabetes, and excessive iron uptake by beta-cells can cause oxidative stress and inhibit function. Elevated levels of proinflammatory cytokines in obese individuals, such as interleukin (IL)-1beta and IL-6, increase the risk of developing type 2 diabetes, and there is evidence that these low levels of circulating cytokines can lead to islet dysfunction. Methods: In this study, gene microarray and other data were analyzed for expression differences in islets treated for 48 h with 10 pg/mL IL-1beta + 20 pg/mL IL-6 as a model of low-grade inflammation versus untreated. Results: Three iron-associated genes were among the most cytokine-sensitive in the mouse genome: Hamp, Steap4, and Lcn2. These proteins are all involved with increasing/retaining cellular iron. We hypothesized that increased cellular iron would lead to increased susceptibility to ferroptosis. Surprisingly, 24 h pre-exposure to low-grade inflammation, which upregulates this iron-gene network, prevented subsequent erastin-induced ferroptosis. We also found that Steap4 overexpression reduced islet dysfunction caused by high-dose proinflammatory cytokines (10× low-dose), suggesting an overall protective effect. Steap4 overexpression also upregulated Hamp and Lcn2, suggesting Steap4 regulates these cytokine-sensitive iron genes.; in contrast, ferritin and ferroportin gene expression, which are not sensitive to cytokines, were unchanged. Conclusions: These data suggest an inflammation-induced network of genes involved in cellular iron uptake and retention plays a protective role in islets against oxidative stress and ferroptosis.

IL-1β↗

Fluorescence and phosphorescence of photomultiplier window materials under electron irradiation

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation were investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV grade, optical grade, and electron-irradiated samples of MGF2 and LiF, CaF2, BaF2, sapphire, fused silica, and UV transmitting glasses were obtained over the spectral range of 200 nm to 650 nm. Fluorescence yields, expressed as the number of counts in a solid angle of 2 pi steradian per 1MeV of incident electron energy deposited, were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively.

Viehmann, W.↗

The current status of REH theory

A response is made to the evaluation of Fitch (1980) of REH (random evolutionary hits) theory for the evolutionary divergence of proteins and nucleic acids. Correct calculations for the beta hemoglobin mRNAs of the human, mouse and rabbit in the absence and presence of selective constraints are summarized, and it is shown that the alternative evolutionary analysis of Fitch underestimates the total fixed mutations. It is further shown that the model used by Fitch to test for the completeness of the count of total base substitutions is in fact a variant of REH theory. Considerations of the variance inherent in evolutionary estimations are also presented which show the REH model to produce no more variance than other evolutionary models. In the reply, it is argued that, despite the objections raised, REH theory applied to proteins gives inaccurate estimates of total gene substitutions. It is further contended that REH theory developed for nucleic sequences suffers from problems relating to the frequency of nucleotide substitutions, the identity of the codons accepting silent and amino acid-changing substitutions, and estimate uncertainties.

Holmquist, R.↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗