Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “battery heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

Lithium-Ion Batteries with Safer Current Collectors

The US Department of Energy’s Oak Ridge National Laboratory and Soteria Battery Innovation Group collaborated to develop a metallized polymer film as a current collector for lithium-ion batteries and design slit patterns for electrodes to improve battery safety. The metallized polymer film serves as a fuse that will break under high temperature resulting from a short circuit. Consequently, the short circuit will be broken and the heat generated from the short circuit will be alleviated to avoid thermal runaway. The electrodes with slit patterns are expected to be broken into small segments upon mechanical impact, which can isolate the damaged electrodes from the rest. Thus, the heat generation associated with the mechanical impact will be reduced, along with the likelihood of thermal runaway. This effort aimed to improve lithium-ion battery safety by replacing traditional metal foils with metallized polymer films as current collector and introducing slit patterns to battery electrodes. The metallized polymer films were polyethylene terephthalate with a thin metal (aluminum for cathodes and copper for anodes) coating on both sides. Slit patterns with various geometries and dimensions were designed via simulation. Temperature distribution on cells with electrodes with and without slit patterns was also simulated via nemerical modeling. Electrodes on traditional metal foils and metallized polymer films were coated via a pilot-scale slot-die coater at the US Department of Energy Battery Manufacturing Facility at Oak Ridge National Laboratory. The electrodes were calendered to 35% porosity and punched out with and without slit patterns. Pouch cells were assembed with the electrodes inside a dry room for electrochemical and safety testing. Electrodes coated on metallized polymer films exhibited comparable electrochemical performance to their counterparts coated on traditional metal foils. They also showed improved safety in nail penetration and indentation tests.

25 ENERGY STORAGE↗

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries↗

Wind power demonstration and siting problems

Technical and economic feasibility studies on a small windmill to provide overnight charging for an electrically driven car are reported. The auxiliary generator provides power for heating and cooling the vehicle which runs for 25 miles on battery power alone, and for 50 miles with the onboard charger operating. The blades for this windmill have a diameter of 12 feet and are coupled through to a conventional automobile alternator so that they are able to completely recharge car batteries in 8 hours. Optimization of a windmill/storage system requires detailed wind velocity information which permits rational sitting of wind power system stations.

Bergey, K. H.↗

Development of an All-Aqueous Thermally Regenerative Redox Flow Battery to Support Fossil Fuel Assets

Low-temperature thermal energy, a largely untapped resource, holds significant promise for large-scale electrical power generation globally. Various stationary sources, including industrial entities and thermal power plants, emit considerable low-temperature heat that currently remains unutilized. This energy is often overlooked because its low temperature renders it unsuitable for efficient power generation using conventional methods. However, current research is exploring diverse technologies capable of converting low-temperature heat into grid-scale power, aiming to enhance grid efficiency, further decarbonization initiatives, and facilitate a shift toward more decentralized power systems. One such innovative technology is the thermally regenerative battery (TRB), noted for its high power and energy densities compared to similar technologies, positioning it as a potential game-changer in power generation. TRBs integrate two scalable and well-established unit operations: a redox flow battery and a distillation column. This integration suggests that once an effective TRB chemistry is established, the pathway to commercialization could be expedited. The copper-based thermally regenerative ammonia battery (Cu aq -TRAB) stands out as the first TRB that circumvents electrodeposition/dissolution reactions, stabilizing Cu(I) and Cu(II) within the electrolyte and maintaining stability of all electroactive species in an aqueous phase. This stabilization has led to improvements in coulombic efficiency, open circuit potential, and copper solubility, thereby enhancing power density, energy density, and overall energy efficiency. Preliminary tests were conducted to determine the effects of various electrolyte species on the performance metrics of the battery, both theoretically and experimentally. These tests revealed that the solubility of copper in the Cu aq -TRAB electrolyte was constrained by the Cu(I)-NH 3 complex. Adjusting the background electrolyte to 5 M NH4Br and the ligand concentration to 4 M NH 3 enabled the copper concentration to reach a maximum of 0.6 M. This modification led to an estimated theoretical maximum energy density of 9.5 Wh L -1 for the Cu aq -TRAB. Additionally, full cell testing indicated a tradeoff between peak power and energy density with varying copper and ammonia concentrations. Increasing the applied current density during discharge linearly raised the average power output, with a minimal reduction in energy density due to a balance between higher ohmic overpotential and reduced time for undesirable ammonia crossover. Furthermore, a comprehensive numerical sensitivity analysis of the complete Cu aq -TRAB system was performed. This analysis aimed to assess how the battery and the distillation column responded to changes in system input parameters, providing insights into optimal research directions for enhancing system performance. The analysis revealed that at room temperature, battery power was significantly more sensitive to ohmic losses than to mass transfer, with reaction rates having minimal impact. This trend continued even at higher temperatures. Also, the thermal energy required for ammonia separation was studied, showing that increased temperatures generally reduced energy requirements, except in low-pressure scenarios above 65 °C. An investigation into membrane performance in the Cu aq -TRAB was undertaken, given the significant impact of ammonia transport control and ohmic losses on system performance. Various membranes were evaluated to identify key performance metrics. Among the tested membranes, Selemion CMVN exhibited the highest performance, with a peak power density of 84 mW cm -2 and average values of 26 ± 6.8 mW cm -2 for power density and 2.9 Wh L -1 for energy density at an applied current density of 50 mA cm -2 . An economic assessment indicated a levelized cost of storage at $410 per MWh under optimal conditions, highlighting the commercial potential of the Cu aq -TRAB when utilizing cost-effective, readily available materials.

25 ENERGY STORAGE↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Heat Battery for Electrical Grid Energy

In this paper, the fundamental principles from the Georgetown Systems Engineering Fundamentals course will be leveraged to provide a viable solution to the problem of providing cost effective energy storage for renewable electricity generation. As described in the need statement, this is necessary due to the non-dispatchable nature of renewable energy sources. Upon describing the need, several key stakeholders were identified, who may or may not directly interact with the system. They provided several characteristics and capabilities that the system should contain, as well as specific key acceptance criteria which serve as a pass/fail metric for the concept selection process. Out of three different concepts, a Pugh matrix was used to determine that a heat battery system would be the right fit for the scope of work needing to be done.

25 ENERGY STORAGE↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

CHARACTERIZATION AND DEVELOPMENT OF THE ALL–AQUEOUS COPPER THERMALLY REGENERATIVE AMMONIA BATTERY

Low temperature thermal energy is an abundant and untapped energy source for large scale electrical power and energy production around the world. Many different stationary sources such as industrial and thermal power plants produce significant amounts of low temperature heat that goes unused. The primary reason for the energy loss is because the temperature of the heat is often too low for traditional systems to economically generate power from this waste heat. Many different technologies are being researched to produce grid–scale power from low temperature heat to increase grid efficiency, advance decarbonization efforts, and progress electrical power production to a more distributed system. A thermally regenerative battery (TRB) is one promising technology in this space, as it has large power and energy densities relative to competitive technologies and therefore has the potential to disrupt the current power generation mix. TRBs combine two unit operations (a redox flow battery and a distillation column) which are easily scalable and mature, meaning that if a viable TRB chemistry can be identified, its development to pilot and commercial scale can be streamlined. The all–aqueous, copper thermally regenerative ammonia battery (Cuaq–TRAB) was the first TRB that did not use an electrodeposition/dissolution reaction by stabilizing Cu(I) and Cu(II) in the electrolyte, allowing all electroactive species to be stable in an aqueous phase. Through these electrolyte modifications, coulombic efficiency, open circuit potential, and copper solubility all increased, resulting in large gains to power density, energy density, and energy efficiency.

Cross, Nicholas↗

Quantifying Socioeconomic Impacts of Electricity Generating Technologies

The levelized cost of energy (LCOE) and other cost metrics used in energy planning do not account for out-of-market impacts of the technology choice. While a decision-maker at the utility or asset owner level may compare multiple forms of electricity generating technology using LCOE, a decision-maker over energy policy or community stakeholders may be interested in considering impacts beyond those that LCOE measures. This report quantifies economic impacts such as jobs and wage growth across electricity generation technologies then develops an approach to systematically compare socioeconomic metrics across technology choices. To address additional workforce related impacts, this report also compares the typical workforce education requirements and annual income levels for multiple types of electricity generating facilities. The grid scale electricity generating technologies analyzed in this report produce power using conventional hydroelectric dams, coal, natural gas, nuclear reactors, solar PV, land-based wind turbines, geothermal heat, and woody biomass combustion. Although it doesn’t generate electricity itself, the economic impacts associated with battery storage equipment manufacturing and installation were also analyzed.

03 NATURAL GAS↗

Nano Goes Magnetic to Attract Big Business

Glenn Research Center has combined state-of-the-art electrical designs with complex, computer-aided analyses to develop some of today s most advanced power systems, in space and on Earth. The center s Power and On-Board Propulsion Technology Division is the brain behind many of these power systems. For space, this division builds technologies that help power the International Space Station, the Hubble Space Telescope, and Earth-orbiting satellites. For Earth, it has woven advanced aerospace power concepts into commercial energy applications that include solar and nuclear power generation, battery and fuel cell energy storage, communications and telecommunications satellites, cryocoolers, hybrid and electric vehicles, and heating and air-conditioning systems.

Source record↗

Phase Change Material Thermal Power Generator

An innovative modification has been made to a previously patented design for the Phase Change Material (PCM) Thermal Generator, which works in water where ocean temperature alternatively melts wax in canisters, or allows the wax to re-solidify, causing high-pressure oil to flow through a hydraulic generator, thus creating electricity to charge a battery that powers the vehicle. In this modification, a similar thermal PCM device has been created that is heated and cooled by the air and solar radiation instead of using ocean temperature differences to change the PCM from solid to liquid. This innovation allows the device to use thermal energy to generate electricity on land, instead of just in the ocean.

Jones, Jack A.↗

A Thermodynamic Reassessment of Lithium-Ion Battery Cathode Calorimetry

This work demonstrates how staged heat release from layered metal oxide cathodes in the presence of organic electrolytes can be predicted from basic thermodynamic properties. These prediction methods for heat release are an advancement compared to typical modeling approaches for thermal runaway in lithium-ion batteries, which tend to rely exclusively on calorimetry measurements of battery components. These calculations generate useful new insights when compared to calorimetry measurements for lithium cobalt oxide (LCO) as well as the most common varieties of nickel manganese cobalt oxide (NMC) and nickel cobalt aluminum oxide (NCA). Accurate trends in heat release with varying state of charge are predicted for all of these cathode materials. These results suggest that thermodynamic calculations utilizing a recently published database of properties are broadly applicable for predicting decomposition behavior of layered metal oxide cathodes. Aspects of literature calorimetry measurements relevant to thermal runaway modeling are identified and classified as thermodynamic or kinetic effects. The calorimetry measurements reviewed in this work will be useful for development of a new generation of thermal runaway models targeting applications where accurate maximum cell temperatures are required to predict cascading cell-to-cell propagation rates.

25 ENERGY STORAGE↗

Thermal Systems Modeling of Chemical Integrated Power Source (CHIPS) to Survive Lunar Night Environments

This paper presents the results of the systems level thermal modeling for a conceptual Chemical Heat Integrated Power Source (CHIPS). This proposed system offers a combined thermal and electrical power source to support survival of spacecraft operating in extreme low temperature lunar environments, without the use of radioisotope-based sources. A conceptual design study has been completed for this system, that uses heat generated by an exothermic chemical reaction in place of radioisotope or electrical heat sources. The goal of the study was to evaluate the feasibility of such as system through thermodynamic and chemical analysis and thermal modeling, and to identify technology gaps to inform a technology development and maturation plan. The specific technical objectives focused on delivery of 90-100 Wth thermal power and 30-40 We electrical power for 336 hours to a representative Commercial Lunar Payload Services (CLPS) lander, to support lunar surface survival and limited operations through a lunar night. The total system mass was targeted at ≤50 kg. A highly exothermic chemical reaction system is used to generate on-board electrical power for spacecraft systems, and thermal power to maintain critical spacecraft/lander systems within their allowable flight temperature (AFTs). Based on the very high energy content of the chemical reaction system, a much higher amount of heat per unit mass can be delivered to the spacecraft, relative to a rechargeable lithium-ion battery and electrical heater(s). Since radioisotope heaters or generators are not used, the system will be orders of magnitude lower in cost than a radioisotope heating/power unit, without the attendant regulatory complexities. As part of the CHIPS concept, a fraction of the thermal power generated is converted to electrical power via an appropriate thermal-to-electric converter technology (such as a free piston Stirling converter or a thermoelectric generator module), to provide power to critical loads. This approach is ideally suited to support operation of commercial landers (e.g., via the CLPS program). In most cases, these landers are only designed to operate during a portion of the lunar day, with no provision for survival through the lunar night. By supporting lunar night survival, a mission can be extended through the lunar night and at least into another lunar day, thus turning a nominal eight-day mission into a 36-day mission. Therefore, the current system demonstration will focus on scalability to support at least 336 hours (one lunar night) of continuous thermal and electrical power generation. Although initially targeted to support lunar equatorial landings, the technology is extensible to missions at the lunar poles, other extreme environments in the Solar System or even air-independent applications on Earth (e.g., ocean exploration).

West, William↗

Thermal Systems Modeling of Chemical Heat Integrated Power Source (CHIPS) to Survive Lunar Night Environments

This paper presents the results of the systems level thermal modeling for a conceptual Chemical Heat Integrated Power Source (CHIPS). This proposed system offers a combined thermal and electrical power source to support survival of spacecraft operating in extreme low temperature lunar environments, without the use of radioisotope-based sources. A conceptual design study has been completed for this system, that uses heat generated by an exothermic chemical reaction in place of radioisotope or electrical heat sources. The goal of the study was to evaluate the feasibility of such a system through thermodynamic and chemical analysis and thermal modeling, and to identify technology gaps to inform a technology development and maturation plan. The specific technical objectives focused on delivery of 90 to 100 Wth thermal power and 30 to 40 We electrical power for 336 hours to a representative Commercial Lunar Payload Services (CLPS) lander, to support lunar surface survival and limited operations through a lunar night. The total system mass was targeted at ≤50 kg. A highly exothermic chemical reaction system is used to generate on-board electrical power for spacecraft systems, and thermal power to maintain critical spacecraft/lander systems within their allowable flight temperature (AFTs). Based on the very high energy content of the chemical reaction system, a much higher amount of heat per unit mass can be delivered to the spacecraft, relative to a rechargeable lithium-ion battery and electrical heater(s). Since radioisotope heaters or generators are not used, the system will be orders of magnitude lower in cost than a radioisotope heating/power unit, without the attendant regulatory complexities. As part of the CHIPS concept, a fraction of the thermal power generated is converted to electrical power via an appropriate thermal-to-electric converter technology (such as a free piston Stirling converter or a thermoelectric generator module), to provide power to critical loads. This approach is ideally suited to support operation of commercial landers (e.g., via the CLPS program). In most cases, these landers are only designed to operate during a portion of the lunar day, with no provision for survival through the lunar night. By supporting lunar night survival, a mission can be extended through the lunar night and at least into another lunar day, thus turning a nominal eight-day mission into a 36-day mission. Therefore, the current system demonstration will focus on scalability to support at least 336 hours (one lunar night) of continuous thermal and electrical power generation. Although initially targeted to support lunar equatorial landings, the technology is extensible to missions at the lunar poles, other extreme environments in the Solar System or even air-independent applications on Earth (e.g., ocean exploration).

West, William↗

Understanding the Nature of Capacity Decay and Interface Properties in Li//LiNi 0.5 Mn 1.5 O 4 Cells by Cycling Aging and Titration Techniques

The spinel structure LiNi 0.5 Mn 1.5 O 4 (LNMO) is a propitious cathode material for next-generation lithium-ion batteries for fast charge–discharge applications, but its capacity decay mechanism and rate-limiting process are not yet well understood. In this work, electrochemical impedance spectroscopy (EIS) with galvanostatic intermittent titration (GITT) and cycling aging techniques were employed to investigate the nature of capacity decay in disordered-phase LNMO. Different resistive components were separated after every 10 cycles. Cell overvoltages (ΔVs) due to ohmic conduction, charge transfer (CT), and concentration polarization (CP) were individually determined. Results revealed that the cell exhibited a higher ΔV at a higher discharged state. However, the ΔV value for CP was higher at a higher state of charge (SOC), and the overall LNMO/electrolyte interface played a major role in the rate-determining step. Battery life was estimated based on the results. Battery calendar life was found to be more vulnerable than cycle life. Furthermore, results also indicated that the working SOC range could be optimized based on the resistance analysis by avoiding those SOCs that have the most detrimental impact (e.g., heat generation and fire hazard).

25 ENERGY STORAGE↗

Flash Recycling of Graphite Anodes

The ever-increasing production of commercial lithium-ion batteries (LIBs) will result in a staggering accumulation of waste when they reach their end of life. A closed-loop solution, with effective recycling of spent LIBs, will lessen both the environmental impacts and economic cost of their use. Presently, <5% of spent LIBs are recycled and the regeneration of graphite anodes has, unfortunately, been mostly overlooked despite the considerable cost of battery-grade graphite. Here, in this work, an ultrafast flash recycling method to regenerate the graphite anode is developed and valuable battery metal resources are recovered. Selective Joule heating is applied for only seconds to efficiently decompose the resistive impurities. The generated inorganic salts, including lithium, cobalt, nickel, and manganese, can be easily recollected from the flashed anode waste using diluted acid, specifically 0.1 M HCl. The flash-recycled anode preserves the graphite structure and is coated with a solid-electrolyte-interphase-derived carbon shell, contributing to high initial specific capacity, superior rate performance, and cycling stability, when compared to anode materials recycled using a high-temperature-calcination method. Life-cycle-analysis relative to current graphite production and recycling methods indicate that flash recycling can significantly reduce the total energy consumption and greenhouse gas emission while turning anode recycling into an economically advantageous process.

36 MATERIALS SCIENCE↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗