Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuation correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Correction of Path Integrated Attenuation Estimates Considering the Soil Moisture Effect for the Gpm Dual-Frequency Precipitation Radar

Spaceborne precipitation radars, including the Tropical Rainfall Measuring Mission’s Precipitation Radar (PR) and the Global Precipitation Measurement Mission’s Dual-Frequency Precipitation Radar (DPR), measure not only precipitation echoes but surface echoes as well, the latter of which are used to estimate the path-integrated attenuation (PIA) in the surface reference technique (SRT). In our previous study based on analyzing PR measurements, we found that attenuation-free surface backscattering cross sections (denoted by s0e) over land increased in the presence of precipitation. This behavior, called the soil moisture effect, causes an underestimate of the PIA by the SRT as the method does not explicitly consider this effect. In this study, measurements made by Ku-band Precipitation Radar (KuPR) and Ka-band Precipitation Radar (KaPR), which comprise the DPR, were analyzed to examine whether KuPR and KaPR exhibit similar dependencies on the soil moisture as does the PR. For both KuPR and KaPR, an increase in s0e was observed for a large portion of the land area, except for forests and deserts. Results from the Hitschfeld–Bordan (HB) method suggest that s0e increases with the surface precipitation rate for light precipitation events. Meanwhile, for heavy precipitation, owing to the degradation of the HB method, it is difficult to estimate s0e quantitatively. Thus, a correction method for PIA that considers the soil moisture effect was developed and implemented into the DPR standard algorithm. With this correction, the surface precipitation rate estimates increased by approximately 18%for KuPR and 15%for the normal scan of KaPR over land.

Shinta Seto↗

Development of techniques for advanced optical contamination measurement with internal reflection spectroscopy, phase 1, volume 1

The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.

Hayes, J. D.↗

C-band attenuation by tropical rainfall in Darwin, Australia, using climatologically tuned Z(e)-R relations

The probability matching method (PMM) is used as a basis for estimating attenuation in tropical rains near Darwin, Australia. PMM provides a climatological relationship between measured radar reflectivity and rain rate, which includes the effects of rain and cloud attenuation. When the radar sample is representative, PMM estimates the rainfall without bias. When the data are stratified for greater than average rates, the method no longer compensates for the higher attenuation and the radar rainfall estimates are biased low. The uncompensated attenuation is used to estimate the climatological attenuation coefficient. The two-way attenuation coefficient was found to be 0.0085 dB/km ( mm/h) exp -1.08 for the tropical rains and associated clouds in Darwin for the first two months of the year for horizontally polarized radiation at 5.63 GHz. This unusually large value is discussed. The risks of making real-time corrections for attenuation are also treated.

Atlas, David↗

Automated Model for Improved Mapping of Country-Scale High-Resolution Coastal Bathymetry

Accurate and up-to-date maps of coastal bathymetry are critical for a variety of sectors from vessel navigation to port construction and are increasingly vital to inform coastal infrastructure management amid accelerating sea-level rise and more frequent and severe storm-surge events. The primary challenges to accurate and efficient bathymetric mapping from optical remote sensing are: accurately modeling light attenuation in both the atmosphere and water column; and inefficient data processing pipelines for highresolution satellite imagery. To address the effects of light attenuation within the water-column we have developed a novel physics-based bathymetry model that accounts for variations in water-column inherent optical properties on a pixel-by-pixel basis in optically-shallow aquatic environments, which represents a major advancement. For applications to satellite imagery, we have developed a software package that automatically applies the robust 6S atmospheric correction algorithm, estimates the bottom depth from the physics-based bathymetry model, which corrects for attenuation by suspended particulate matter and colored dissolved organic matter in the water column on a pixel-by-pixel basis, and leverages highperformance computing for rapid application to region-scale (e.g., CONUS) 2-meter resolution imagery datasets. Our approach is tailored to sensors that collect data at two-meter resolution with high return times for frequent updates. We mapped 591 WorldView satellite images for Florida, North Carolina, and Alaska and validated the maps against LiDAR-derived bathymetry data. Results show median RMSE of 1.75, 1.59, and 2.67 meters, respectively. By combining the strengths of Oak Ridge National Laboratory in high-performance computing and remote-sensing science with the water-column modeling expertise of Scripps Institution of Oceanography we advance the state of bathymetric mapping capability.

54 ENVIRONMENTAL SCIENCES↗

Factors That Influence Variability in Stress-Drop Measurements Using Spectral Decomposition and Spectral-Ratio Methods for the 2019 Ridgecrest Earthquake Sequence

Stress drop is a fundamental parameter related to earthquake source physics, but is hard to measure accurately. To better understand how different factors influence stress-drop measurements, we compare two different methods using the Ridgecrest stress-drop validation data set: spectral decomposition (SD) and spectral ratio (SR), each with different processing options. Here, we also examine the influence of spectral complexity on source parameter measurement. Applying the SD method, we find that frequency bandwidth and time-window length could influence spectral magnitude calibration, while depth-dependent attenuation is important to correctly map stress-drop variations. For the SR method, we find that the selected source model has limited influence on the measurements; however, the Boatwright model tends to produce smaller standard deviation and larger magnitude dependence than the Brune model. Variance reduction threshold, frequency bandwidth, and time-window length, if chosen within an appropriate parameter range, have limited influence on source parameter measurement. For both methods, wave type, attenuation correction, and spectral complexity strongly influence the result. The scale factor that quantifies the magnitude dependence of stress drop show large variations with different processing options, and earthquakes with complex source spectra deviating from the Brune-type source models tend to have larger scale factor than earthquakes without complexity. Based on these detailed comparisons, we make a few specific suggestions for data processing workflows that could help future studies of source parameters and interpretations.

58 GEOSCIENCES↗

Improved Gamma-Ray Point Source Quantification in Three Dimensions by Modeling Attenuation in the Scene

We discuss using a series of detector measurements taken at different locations to localize a source of radiation as a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2D and even 3D, but few have studied the effect of intervening material on the problem. In this work we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from the onboard LiDAR. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interpolated Sounding and Gridded Sounding Value-Added Products

Standard Atmospheric Radiation Measurement (ARM) Climate Research Facility sounding files provide atmospheric state data in one dimension of increasing time and height per sonde launch. Many applications require a quick estimate of the atmospheric state at higher time resolution. The INTERPOLATEDSONDE (i.e., Interpolated Sounding) Value-Added Product (VAP) transforms sounding data into continuous daily files on a fixed time-height grid, at 1-minute time resolution, on 332 levels, from the surface up to a limit of approximately 40 km. The grid extends that high so the full height of soundings can be captured; however, most soundings terminate at an altitude between 25 and 30 km, above which no data is provided. Between soundings, the VAP linearly interpolates atmospheric state variables in time for each height level. In addition, INTERPOLATEDSONDE provides relative humidity scaled to microwave radiometer (MWR) observations.The INTERPOLATEDSONDE VAP, a continuous time-height grid of relative humidity-corrected sounding data, is intended to provide input to higher-order products, such as the Merged Soundings (MERGESONDE; Troyan 2012) VAP, which extends INTERPOLATEDSONDE by incorporating model data. The INTERPOLATEDSONDE VAP also is used to correct gaseous attenuation of radar reflectivity in products such as the KAZRCOR VAP.

54 ENVIRONMENTAL SCIENCES↗

Detection of soft X-ray emission from SMC X-1

The observation of 0.25-keV X-rays from SMC X-1 by a soft X-ray experiment aboard OSO 8 is reported. The variable soft X-ray source observed is identified with the hard X-ray source SMC X-1 on the basis of a rather abrupt ending to the emission (fall time about 2.5 hr) at the time SMC X-1 was expected to enter eclipse. A source luminosity of about 5 x 10 to the 38th erg/s in the 0.18-0.28-keV range is derived by assuming a distance of 68 kpc and correcting for attenuation by 3.4 x 10 to the 20th H atoms per sq cm of intervening galactic gas; this luminosity is shown to be about a factor of 40 greater than the observed coincident luminosity in the 0.8-3-keV band. The soft X-ray intensity upon emergence from eclipse is found to be reduced by a factor of at least 20 from the peak intensity prior to eclipse. It is suggested that this asymmetry may reflect a geometry in which the soft X-ray source trails the compact star as in an accretion-stream model.

Bunner, A. N.↗

The Effect of Rain on Nadir Ocean Backscatter in TOPEX Radar Altimeter Data

Rainfall profile from the 14 GHz TRMM Precipitation Radar will require correction for attenuation effects. An important technique for this is the surface reference technique, which estimates the path attenuation through rain by comparing the clear air ocean backscatter with ocean backscatter in rain.

surface reference technique intrinsic ocean backsc↗

Changes in the TRMM Version-5 and Version-6 Precipitation Radar Products Due to Orbit Boost

The performance of the version-5 and version-6 Tropical Rainfall Measuring Mission (TRMM) Precipitation Radar (PR) products before and after the satellite orbit boost is assessed through a series of comparisons with Weather Surveillance Radar (WSR)-88D ground-based radar in Melbourne, Florida. Analysis of the comparisons of radar reflectivity near the storm top from the ground radar and both versions of the PR indicates that the PR bias relative to the WSR radar at Melbourne is on the order of 1dB for both pre- and post-boost periods, indicating that the PR products maintain accurate calibration after the orbit boost. Comparisons with the WSR-88D near-surface reflectivity factors indicate that both versions of the PR products accurately correct for attenuation in stratiform rain. However, in convective rain, both versions exhibit negative biases in the near-surface radar reflectivity with version-6 products having larger negative biases than version-5. Rain rate comparisons between the ground and space radars show similar characteristics

Liao, Liang↗

Tests of Radar Rainfall Retrieval Algorithms

The NASA/JPL Airborne Rain Mapping Radar (ARMAR) operates at 14 GHz. ARMAR flew on the NASA DC-8 aircraft during Tropical Ocean Global Atmosphere (TOGA) Coupled Ocean Atmosphere Response Experiment (COARE), collecting data in oceanic mesoscale convective systems, similar to those now being observed by the Tropical Rainfall Measuring Mission (TRMM) satellite, which includes a 14-GHz precipitation radar. Several algorithms for retrieving rain rate from downward looking radars are in existence. These can be categorized as deterministic and stochastic. Deterministic algorithms use the path integrated attenuation (PIA), measured by the surface reference technique, as a constraint. One deterministic algorithm corrects the attenuation-rainfall (k-R) relation, while another corrects the reflectivity rainfall (ZR) relation. Stochastic algorithms apply an Extended Kalman Filter to the reflectivity profile. One employs radar reflectivity only; the other additionally uses the PIA. We find that the stochastic algorithm with PIA is the most robust algorithm with regard to incorrect assumptions about the drop-size distribution (DSD). The deterministic algorithm that uses the PIA to adjust the Z-R relation is also fairly robust and produces rain rates similar to the stochastic algorithm that uses the PIA. The deterministic algorithm that adjusts only the k-R relation and the stochastic radar-only algorithm are more sensitive to assumptions about the DSD. It is likely that they underestimate convective rainfall, especially if the DSD is erroneously assumed to be appropriate for stratiform rain conditions. The underestimation is illustrated in the diagram. The algorithm labeled D IS initially assumes a DSD that is appropriate for stratiform. rain, while the rain is most likely convective. The PIA constraint causes the k-R relation to be adjusted, resulting in a much lower rain rate than the other algorithms. Additional information is contained in the original.

Durden, Stephen L.↗

On Compatible Transfer Operators in Nonsymmetric Algebraic Multigrid

The standard goal for an effective algebraic multigrid (AMG) algorithm is to develop relaxation and coarse-grid correction schemes that attenuate complementary error modes. In the nonsymmetric setting, coarse-grid correction Π will almost certainly be nonorthogonal (and divergent) in any known standard product, meaning ∥Π∥ > 1. This introduces a new consideration, that one wants coarse-grid correction to be as close to orthogonal as possible, in an appropriate norm. In addition, due to nonorthogonality, Π may actually amplify certain error modes that are in the range of interpolation. Relaxation must then not only be complementary to interpolation, but also rapidly eliminate any error amplified by the nonorthogonal correction, or the algorithm may diverge. Here this paper develops analytic formulae on how to construct “compatible” transfer operators in nonsymmetric AMG such that ∥Π∥ = 1 in some standard matrix-induced norm. Discussion is provided on different options for the norm in the nonsymmetric setting, the relation between “ideal” transfer operators in different norms, and insight into the convergence of nonsymmetric reduction-based AMG.

97 MATHEMATICS AND COMPUTING↗

A Ground-based UV Light Source for the Euso Mission

The Extreme Universe Space Observatory (EUSO) mission will measure the uorescence signal produced by Extensive Air Showers (EAS). To determine the intrinsic shower luminance and hence the energy of the incident cosmic ray, a correction must be made for attenuation in the atmosphere. The correction will be determined on an event-by-event basis by atmospheric sounding with a LIDAR. We report here on a "ground truth" concept to verify EUSO's measurements of intrisic shower luminance.

Adams, J. H.↗

Radiometric correction of scatterometric wind measurements

Use of a spaceborne scatterometer to determine the ocean-surface wind vector requires accurate measurement of radar backscatter from ocean. Such measurements are hindered by the effect of attenuation in the precipitating regions over sea. The attenuation can be estimated reasonably well with the knowledge of brightness temperatures observed by a microwave radiometer. The NASA SeaWinds scatterometer is to be flown on the Japanese ADEOS2. The AMSR multi-frequency radiometer on ADEOS2 will be used to correct errors due to attenuation in the SeaWinds scatterometer measurements. Here we investigate the errors in the attenuation corrections. Errors would be quite small if the radiometer and scatterometer footprints were identical and filled with uniform rain. However, the footprints are not identical, and because of their size one cannot expect uniform rain across each cell. Simulations were performed with the SeaWinds scatterometer (13.4 GHz) and AMSR (18.7 GHz) footprints with gradients of attenuation. The study shows that the resulting wind speed errors after correction (using the radiometer) are small for most cases. However, variations in the degree of overlap between the radiometer and scatterometer footprints affect the accuracy of the wind speed measurements.

Source record↗

Ultrasonic Studies of Composites Undergoing Thermal and Fatigue Loading

New composite materials possess attractive properties for use in advanced aircraft. A necessary requirement for their introduction into aeronautic use is an accurate understanding of their long term aging processes so that proper design criteria can be established. In order to understand those properties, these composites must be exposed to thermal and load cycles that are characteristic of flight conditions. Additionally, airline companies will require nondestructive evaluation (NDE) methods that can be used in the field to assess the condition of these new materials as they age. As part of an effort to obtain the required information about new composites for aviation use, we are performing ultrasonic measurements both in the NDE laboratory and in the materials testing laboratory at NASA. The materials testing laboratory is equipped with environmental chambers mounted on load frames so that composite samples can be exposed to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This study reports on our initial ultrasonic attenuation results from thermoset and thermoplastic composite samples. Ultrasonic attenuation measurements have been used reliably to assess the effects of material degradation. For example, recently, researchers have shown that by using frequencies of ultrasound on the order of 24 MHz, they could obtain adequate contrast in the evaluation of thermal degradation in these composites. This paper will present data that shows results at a lower frequency range. In addition, we report results on the frequency dependence of attenuation as the slope of attenuation with respect to frequency, beta = delta alpha (f) / delta f. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This is a consequence of the assumption that interface correction terms are frequently independent. Uncertainty in those corrections terms compromises the value of conventional quantitative attenuation data.

Madaras, Eric I.↗

Galactic absorption of high-energy gamma-rays from Cygnus X-3

The importance of cosmic blackbody photons as an absorbing gas for the attenuation of high-energy photons via pair production in photon-photon collision is examined for the specific case of gamma rays from Cyg X-3. Recent observational results on this photon flux in the range from 2 x 10 to the 15th to 2 x 10 to the 16th eV are corrected for this attenuation. The absorption optical depth to the source is about unity, and the corrected flux is about a factor of three higher; as a result, it does not extrapolate from the data at lower energies (10 to the 12th eV).

Gould, R. J.↗

Ultrasonic Attenuation Results of Thermoplastic Resin Composites Undergoing Thermal and Fatigue Loading

As part of an effort to obtain the required information about new composites for aviation use, materials and NDE researchers at NASA are jointly performing mechanical and NDE measurements on new composite materials. The materials testing laboratory at NASA is equipped with environmental chambers mounted on load frames that can expose composite materials to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This report highlights our initial ultrasonic attenuation results from thermoplastic composite samples that have undergone over 4000 flight cycles to date. Ultrasonic attenuation measurements are a standard method used to assess the effects of material degradation. Recently, researchers have shown that they could obtain adequate contrast in the evaluation of thermal degradation in thermoplastic composites by using frequencies of ultrasound on the order of 24 MHz. In this study, we address the relationship of attenuation measured at lower frequencies in thermoplastic composites undergoing both thermal and mechanical loading. We also compare these thermoplastic results with some data from thermoset composites undergoing similar protocols. The composite s attenuation is reported as the slope of attenuation with respect to frequency, defined as b = Da(f)/Df. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This latter feature is a consequence of the assumption that interface correction terms are frequency independent. Uncertainty in those correction terms can compromise the value of conventional quantitative attenuation data. Furthermore, the slope of the attenuation more directly utilizes the bandwidth information and in addition, the bandwidth can be adjusted in the post processing stage to compensate for the loss of dynamic range of the signal as the composites age.

Madaras, Eric I.↗