Engineering PapersSearch

SEARCH · Engineering Papers

Results for “arc jet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simultaneous Convective and Radiative Heating of Materials with the 200 kW Laser Enhanced Arc Jet Facility (LEAF)

Recent installation of the 200-kW Laser Enhanced Arc Jet Facility (LEAF) at the Interaction Heating Facility (IHF) arc jet at NASA Ames Research Center has enabled combined heating of material samples. The LEAF system is permanently located adjacent to IHF. During LEAF operation, IHF can convectively heat material samples with heat fluxes up to 0.16 kW/cm 2 using the 22.86-cm nozzle or up to 0.07 kW/cm 2 using the truncated semi-elliptic nozzle. LEAF can deliver radiant heating with various profiles and sizes to a material sample. In flat-top square configuration, irradiance levels of nearly 0.1 kW/cm 2 have been demonstrated over a 43.2 x 43.2 cm area, and irradiance levels up to 0.39 kW/cm 2 have been demonstrated over a 15.2 x 15.2 cm area. LEAF can also be configured to deliver a super-Gaussian profile over a variety of beam diameters (1.8 to 5.6 cm). This configuration has been demonstrated up to peak irradiance levels of 25.7 kW/cm 2 per laser at the smallest, 1.8 cm, diameter setting. The LEAF system is composed of four 50-kW lasers, so it can also be configured to simultaneously deliver two different beam shapes (e.g., one square beam and one super-Gaussian beam).

Megan MacDonald

Kalman Filtering and RTS Smoothing for Arc-Jet Sample Edge Tracking

Accurate and temporally consistent measurements of test-article recession are required to characterize material response during arc-jet ablation experiments. However, image-based boundary measurements are often affected by segmentation noise, brightness variations, and frame-to-frame variability. This work extends arcjetCV [1] with filtering methods for tracking the evolving boundaries of hemispherical and ISO-Q test articles. Two boundary-tracking approaches based on Kalman filtering [2] were implemented. The first applies a point-wise Kalman filter followed by a Rauch–Tung–Striebel smoother [3] to individual boundary-point locations. The second applies the same filtering and smoothing framework to a reduced set of geometry-dependent shape parameters. The point-wise method reduces local frame-to-frame fluctuations while preserving spatial details along the detected boundary. The shape-parameter method provides a compact and geometrically constrained estimate of the sample contour. Figure 1 illustrates the two approaches for a hemispherical test article. Both methods improve temporal consistency and support more robust estimation of surface recession from arc-jet imagery. The two filtering approaches provide complementary representations of boundary evolution and improve the reliability of image-based recession measurements during arc-jet experiments.

recession measurement

CFD Simulations of the IHF Arc-Jet Flow: 9-Inch Nozzle, Flow Surveys, LEAF Wedge Calibration Data

This paper reports computational analyses and flow characterization studies in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using a wedge model placed in a free jet downstream of new 9-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Both the nozzle and wedge model were specifically designed for testing in the new Laser-Enhanced Arc-jet Facility. Data were obtained using stagnation calorimeters and wedge models placed downstream of the nozzle exit. Two instrumented wedge calibration plates were used: one water-cooled and the other RCG-coated tile plate. Experimental surveys of arc-jet test flow with pitot and heat flux probes were also performed at three arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. By taking into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields, these simulations approximately reproduce the probe survey data and predict the wedge model surface pressure and heat flux measurements.

Arc-jets

Axisymmetric electromagnetic field influence on the characteristic velocity of an arc-jet

Tests for determining the influence of an axisymmetric EM field on the characteristic velocity of an arc jet are presented. The experimental set up is briefly described. Tests were performed with rotation induced by the centrifugal and magnetic fields in the same sense. The fuels used were HE and N2 and the results are discussed. It is found that by variation of the induction, current, and arc jet strength, the behavior is determined essentially by the shape of the cathodic and anodic blobs on the electrodes together with their movement under the combined effect of the aerodynamic and magnetic fields. In view of the different characteristics of He and N2 in respect to the dissociation heat and ionization, it is expected that the regime of the arc jet when used with H2 fuel will be similar to that with He.

Oggero, M.

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. Lateral conduction effects violate the 1D finite slab inverse analysis which is typically used to deduce the heat transfer to such calorimeters. The spherical shaped nose associated with most calorimeters (rather than flat) leads to a bias error that over-estimates the stagnation heating. Non-uniform heating on the face of spherically shaped calorimeters leads to conduction losses to the colder rim of the calorimeter which causes an underestimate of the stagnation heating. These two effects come into play at different times of the calorimeter's exposure to the arc jet, so they do not cancel. The spherical body effects come into play in the early stages of exposure, while the non-uniform heating effect becomes most severe at the later stages of exposure. The bias associated with spherical effects can be avoided by rewriting the 1D finite slab inverse analysis code to solve for 1D conduction in spherical coordinates. However, reducing the bias error associated non-uniform heating requires a somewhat ad hoc modification to the 1D finite element inverse analysis.

Isotherms

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

Pitot tube

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

arc-jet

Stochastic Reconstruction of Thermal Protection Material Properties from Arc-Jet Experiments

Material response models are used to assess reliability using variances in the bond-line temperature predictions based on uncertainties in trajectory, aerothermal environment, and material properties. A key deficiency in the current approach is that input uncertainties are too often subjective, empirical, or ad-hoc, and are not rigorously linked to the arc-jet test data used to develop the TPS material model. While materials such as PICA are well understood, future missions may require more novel materials such as HEEET where unknown uncertainties have real consequences on the ability to assess reliability. A quantifiable estimate of reliability requires an iterative methodology where the parameters driving the variance in bond-line temperature (for example) are systematically identified. A test campaign to collect data or develop new models can then be identified to reduce those input uncertainties. A Bayesian inference loop defines these connections mathematically, i.e., prior knowledge about uncertainty is updated based on observation. While these concepts are well known (and often applied intuitively in a non-rigorous approach), only recent advances in reduced-order modelling have made them computationally viable methods for engineering. By replacing deterministic inverse methods with stochastic approaches, the hope is new materials proposed for future missions can more rapidly be developed with a greater understanding of the TPS material reliability. Two additional steps for the analysis of arc jet test data are discussed. The first is ability to construct a reduced-order model using material response simulations (Icarus/US3D) of the arc-jet test articles, and the second is the inclusion of this surrogate model in the Bayesian inversion process. Both capabilities will be demonstrated using prior PICA arc-jet test data. The quality of a surrogate model will be investigated and the variances on the calibrated material properties will be compared to our current understanding of the PICA material model.

Material response

Computational Simulations of the NASA Langley HyMETS Arc-Jet Facility

The Hypersonic Materials Environmental Test System (HyMETS) arc-jet facility located at the NASA Langley Research Center in Hampton, Virginia, is primarily used for the research, development, and evaluation of high-temperature thermal protection systems for hypersonic vehicles and reentry systems. In order to improve testing capabilities and knowledge of the test article environment, an effort is underway to computationally simulate the flow-field using computational fluid dynamics (CFD). A detailed three-dimensional model of the arc-jet nozzle and free-jet portion of the flow-field has been developed and compared to calibration probe Pitot pressure and stagnation-point heat flux for three test conditions at low, medium, and high enthalpy. The CFD model takes into account uniform pressure and non-uniform enthalpy profiles at the nozzle inlet as well as catalytic recombination efficiency effects at the probe surface. Comparing the CFD results and test data indicates an effectively fully-catalytic copper surface on the heat flux probe of about 10% efficiency and a 2-3 kpa pressure drop from the arc heater bore, where the pressure is measured, to the plenum section, prior to the nozzle. With these assumptions, the CFD results are well within the uncertainty of the stagnation pressure and heat flux measurements. The conditions at the nozzle exit were also compared with radial and axial velocimetry. This simulation capability will be used to evaluate various three-dimensional models that are tested in the HyMETS facility. An end-to-end aerothermal and thermal simulation of HyMETS test articles will follow this work to provide a better understanding of the test environment, test results, and to aid in test planning. Additional flow-field diagnostic measurements will also be considered to improve the modeling capability.

Brune, A. J.

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

inviscid theory

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (LIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper will document the latest improvements of the LIF system design and demonstrations of the redeveloped AHF and IHF LIF systems.

wind tunnels

On Laminar to Turbulent Transition of Arc-Jet Flow in the NASA Ames Panel Test Facility

This paper provides experimental evidence and supporting computational analysis to characterize the laminar to turbulent flow transition in a high enthalpy arc-jet facility at NASA Ames Research Center. The arc-jet test data obtained in the 20 MW Panel Test Facility include measurements of surface pressure and heat flux on a water-cooled calibration plate, and measurements of surface temperature on a reaction-cured glass coated tile plate. Computational fluid dynamics simulations are performed to characterize the arc-jet test environment and estimate its parameters consistent with the facility and calibration measurements. The present analysis comprises simulations of the nonequilibrium flowfield in the facility nozzle, test box, and flowfield over test articles. Both laminar and turbulent simulations are performed, and the computed results are compared with the experimental measurements, including Stanton number dependence on Reynolds number. Comparisons of computed and measured surface heat fluxes (and temperatures), along with the accompanying analysis, confirm that that the boundary layer in the Panel Test Facility flow is transitional at certain archeater conditions.

Gokcen, Tahir

Challenges with Heat Flux Calorimeters used in Arc Jets

Occasionally large errors have occurred in some of the calorimeters used in the arc jet facilities. Some slug calorimeters would measure twice the expected heat flux and some Coaxial TC calorimeters would measure half the expected heat flux. While these errors in heat flux measurements are easy to identify and discard / dismiss, the concern is that less spectacular errors are difficult to detect. This inspired a critical look at the calorimetry used to measure stagnation heat flux in the NASA Ames Arc Jet facilities. Numerous sources of error were investigated, and the culprit in the case of slug calorimeters was determined to be leaks in the stagnation calorimeter assembly resulting in flow along the side of the slug. In the case of the coaxial TC calorimeter, it is hypothesized that in some calorimeters there is a partial electrical short circuit in the Coaxial TC sensor element somewhere in the middle of the calorimeter.

Calorimeter