Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arc density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Nature of convection-stabilized dc arcs in dual-flow nozzle geometry. I - The cold flow field and dc arc characteristics. II - Optical diagnostics and theory

Steady-state low-current air arcs in a dual-flow nozzle system are studied experimentally. The cold flow field with no arc is investigated using a 12.7-mm diameter dual-flow nozzle in a steady-flow facility. Mach number and mass flux distributions are determined for various nozzle-pressure ratios and nozzle-gap spacing. It is found that the shock waves in the converging-diverging nozzles result in a decrease in overal resistance by about 15 percent. Also, Schlieren and differential interferometry techniques are used to visualize the density gradients within the arc plasma and thermal mantle. Both optical techniques reveal a laminar arc structure for a reservoir pressure of 1 atm at various current levels. Experimentally determined axial static pressure and cold-flow mass flux rate distributions and a channel-flow model with constant arc temperatre are used to solve the energy integral for the arc radius as a function of axial distance. The arc electric field strength, voltage, resistance, and power are determined with Ohm's law and the total heat transfer is related to arc power.

Serbetci, Ilter↗

Arcing and discharges in high-voltage subsystems of Space Station

Arcing and other types of electrical discharges are likely to occur in high-voltage subsystems of the Space Station. Results from ground and space experiments on the arcing of solar cell arrays are briefly reviewed, showing that the arcing occurs when the conducting interconnects in the arrays are at negative potential above a threshold, which decreases with the increasing plasma density. Furthermore, above the threshold voltages the arcing rate increases with the plasma density. At the expected operating voltages (approximately 200 V) in the solar array for the space station, arcing is expected to occur even in the ambient ionospheric plasma. If the ionization of the contaminants increases the plasma density near the high-voltage systems, the adverse effects of arcing on the solar arrays and the space station are likely to be enhanced, In addition to arcing other discharge processes are likely to occur in high-voltage subsystems. For example, Paschen discharge is likely to occur when the neutral density N sub n greater that 10 to the 12th cu cm, the corresponding neutral pressure P greater than 3 x 10 to the -5 Torr.

Singh, N.↗

Satellite studies of N/D-2/ emission and ion chemistry in aurorae

The incident particle flux ion and neutral composition data taken on the AE-D satellite have been used to investigate the quantal emission of N2(plus) at 4278 A, N(D-2) at 5200 A, and the ion chemistry in aurorae. The results of a time dependent auroral model have been compared to the data. The calculated 4278 A emission of N2(plus), the 5200 A emission of N(D-2), the densities of O2(plus), NO(plus), N2(plus), O(plus), and the electron density are generally in agreement with the measured values. These results are consistent with the branching ratios and quenching rates deduced from previous studies of the N(D-2) densities in the day-time, mid-latitude ionosphere. It is found that in an auroral arc, the measured atomic oxygen density is lower than predicted by the MSIS model.

Rusch, D. W.↗

Influence of the electron source distribution on field-aligned currents

The field-aligned current density above a discrete auroral arc has been deduced from the downward electron flux and magnetic field measurements onboard the rocket Porcupine flight 4. Both measurements show that the field-aligned current density is, in spite of decreasing peak energies towards the edge of the arc, about 4 times higher there than in the center of the arc. This can be explained by using the single particle description for an anisotropic electron source distribution.

Bruening, K.↗

Parameterized study of the ionospheric modification associated with sun-aligned polar cap arcs

The local ionospheric modification that is due to a generalized steady state solar aligned (SA) arc structure is addressed. For a representative set of SA arc parameters which includes both convection and precipitation, emphasis is placed on the modification by SA polar cap arcs upon the F region electron density and the height integrated conductivity. At low fluxes and low characteristic energies, SA polar cap arcs have the most pronounced relative effect at F region altitudes in darkness for winter solar minimum conditions. The absolute enhancement in summer solar minimum and winter solar maximum is equivalent to that of winter solar minimum, but the higher ambient densities make the relative enhancement less. The TEC enhancement associated with an SA arc may be used to indicate the degree of plasma cross flow across the arc.

Crain, D. J.↗

Anode phenomena in high-current accelerators

Quasi-steady MPD accelerators current conduction and power loss mechanism investigation through local anode fall voltage and current density measurements at different arc current levels

Jahn, R. G.↗

DE 1 observations of theta aurora plasma source regions and Birkeland current charge carriers

Detailed analyses of the DE 1 high-altitude plasma instrument electron and ion data have been performed for four passes during which theta auroras were observed. The data indicate that the theta auroras occur on what appear to be closed field lines with particle signatures and plasma parameters that are quite similar to those of the magnetospheric boundary plasma sheet. The field-aligned currents computed from particle fluxes in the energy range 18-13 keV above the theta auroras are observed to be generally downward on the dawnside of the arcs with a narrower region of larger (higher density) upward currents on the duskside of the arcs. These currents are carried predominantly by field-aligned beams of accelerated cold electrons. Of particualr interest in regions of upward field-aligned current are downward electron beams at energies less than the inferred potential drop above the spacecraft.

Menietti, J. D.↗

Excitation of the E2 and W1 "Arched" Filaments Near the Galactic Center as Deduced from Far-Infrared Spectroscopy

We present measurements of the far-infrared (FIR) fine structure lines [S III] (33 microns), [Si II] (35 microns), [O III] (51, 88 microns), [O I] (63 microns) and [C II] (158 microns) and the adjacent continua along a scan crossing the E2 and W1 thermal radio filaments in the Galactic center 'Arc'. The deduced electron density and excitation vary along the scan by less than factors of two and three, respectively. The properties of the two filaments are similar: the line and continuum fluxes peak at the radio ridge, and the ridge/off-ridge contrast is greatest for the FIR continuum and ionized lines, lower for the single dish radio measurements (Sofue et al. 1986), and smallest for the low excitation lines. The spatial coincidence of the FIR and radio peaks demonstrates that any excitation mechanism for the radio continuum filaments must also account for the FIR line and continuum emission. The FIR luminosity of approx. 3 x 10(exp 5) Solar Luminosity per beam, and the association of [O III] emission with the filaments poses difficulties for shock and MHD models. Photoionization of molecular cloud edges by a random distribution of stars is the most likely excitation mechanism among those proposed. The continuum and the low excitation line fluxes are consistent with an origin in photodissociated molecular material adjacent to the photoionized gas.

Colgan, Sean W.J.↗

Temporal survey of electron number density and electron temperature in the exhaust of a megawatt MPD-Arc thruster

Temporal and radial profiles are obtained 30 cm downstream from the anode for two peak arc currents (11.2 kA and 20 kA) and for various auxiliary magnetic fields (0, 1.0 T, and 2.0T) using the Thomson scattering technique. Average density and temperature are relatively constant for over 100 microseconds with significant fluctuations. Radial profiles obtained are relatively flat for 4 cm from the axis. Compared to earlier 20 cm data, the exhaust density has decreased significantly, the average temperature (4.6 eV) has not changed, and the density hole with an auxiliary magnetic field has enlarged.

Michels, C. J.↗

Temporal survey of electron number density and electron temperature in the exhaust of a megawatt MPD-arc thruster.

Temporal and radial profiles are obtained 30 cm downstream from the anode for two peak arc currents (11.2 kA and 20 kA) and for various auxiliary magnetic fields (0, 1.0 T, and 2.0 T) using the Thomson scattering technique. Average density and temperature are relatively constant for over 100 microseconds with significant fluctuations. Radial profiles obtained are relatively flat for 4 cm from the axis. Compared to earlier 20 cm data, the exhaust density has decreased significantly, the average temperature has not changed, and the density ?hole' with an auxiliary magnetic field has enlarged.

Michels, C. J.↗

Aperture synthesis observations of galactic H II-regions

Aperture synthesis observations at 2.695 GHz and 8.085 GHz of the H II regions NRAO 591, NGC 6857, NGC 7538, M8, W3 and W49A made with the NRAO interferometer are presented. A set of Gaussian functions is derived to describe the radiation distribution of each H II region at each frequency. Fine structure is found in all regions. With the exception of the extended source in W49A, all previously known sources with high excitation parameters are resolved into smaller sources. The electron densities of individual sources range from 100 per cu cm up to 100,000 per cu cm. In NGC 6857, NGC 7538 and W49A, continuum sources smaller than 4 arc sec and with electron densities exceeding 10,000 per cu cm are found close to the known class II OH emission sources. In M8, we find a ring which seems to be split at the position of the O-star Herschel 36.

Wink, J. E.↗

Satellite and ground-based observations of a red arc.

Simultaneous observations carried out during the red-arc period of Aug. 8-9, 1970 at Richland, Washington and by the Ogo 6 satellite are examined in the light of the present-day theoretical knowledge. The observed formation of the arc at the electron temperature peak and density trough supports the thermal-conduction theory of red-arc formation. The lack of dc electric fields in the red-arc region rules out these fields as an excitation mechanism. Particle precipitation as a direct source of red-line emission can also be ruled out by the observations presented. The formation of the arc in the plasmapause region and the detection of low-frequency ac fields are consistent with a theory that predicts wave-particle interaction at the plasmapause as a mechanism for supplying thermal energy to the plasmasphere electrons.

Nagy, A. F.↗

Gas pressure and electron density at the level of the active zone of hollow cathode arc discharges

A model for the longitudinal variations of the partial pressures of electrons, ions, and neutral particles is proposed as a result of an experimental study of pressure variations at the level of the active zone as a function of the various discharge parameters of a hollow cathode arc. The cathode region where the temperature passes through its maximum is called active zone. The proposed model embodies the very important variations which the partial electron and neutral particles pressures undergo at the level of the active zone.

Minoo, M. H.↗

Effects of the hollow cathode discharge on throttled ion thruster performance.

An experimental study performed on a 20 cm electron bombardment thruster shows substantial improvements in throttled performance can be achieved if cathode discharge region diameter and length, cathode flow rate and baffle aperture area are reduced simultaneously. This improvement is related to a thruster operating mode in which arc current does not vary significantly with arc voltage. In this mode it is possible to operate the thruster at a high arc voltage and a correspondingly high primary electron energy without the penalty of a prohibitively high arc power. Langmuir probe data indicate the arc current is limited by the cathode region plasma potential and electron density which are both nearly invariant with arc voltage.

Wilbur, P. J.↗

The effects of arcjet operating condition and constrictor geometry on the plasma plume

Measurements of plasma number density and electron temperature were obtained in the plumes of lab arcjet thrusters using electrostatic probes of both spherical and cylindrical geometry. The two arcjet thrusters used had different constrictor and/or nozzle geometries and operated on mixtures of nitrogen, hydrogen, and ammonia to simulate the decomposition products of hydrazine and ammonia. An increase in the measured electron density was observed for both geometries with increasing arc power at a constant mass flow rate and with increasing mass flow rate at a constant arc current. For a given operating condition, the electron number density decreased exponentially off centerline and followed an inverse distance squared relationship along the thrust axis. Typical measured electron temperatures ranged from 0.1 to 0.2 eV.

Carney, Lynnette M.↗

The effects of arcjet thruster operating condition constrictor geometry on the plasma plume

Measurements of plasma number density and electron temperature were obtained in the plumes of lab arcjet thrusters using electrostatic probes of both spherical and cylindrical geometry. The two arcjet thrusters used had different constrictor and/or nozzle geometries and operated on mixtures of nitrogen, hydrogen, and ammonia to simulate the decomposition products of hydrazine and ammonia. An increase in the measured electron density was observed for both geometries with increasing arc power at a constant mass flow rate and with increasing mass flow rate at a constant arc current. For a given operating condition, the electron number density decreased exponentially off centerline and followed an inverse distance squared relationship along the thrust axis. Typical measured electron temperatures ranged from 0.1 to 0.2 eV.

Carney, Lynnette M.↗

Satellite and ground-based observations of a red arc.

The results of simultaneous satellite and ground-based observations carried out during the red-arc period of August 8-9, 1970, are discussed in the light of present day theory. The formation of the arc at the electron temperature peak and density trough seems to support the thermal-conduction theory of red-arc formation.

Nagy, A. F.↗

Transonic flow past an airfoil with condensation

In connection with investigations conducted to determine the influence of water vapor on experiments in wind tunnels, the question arose as to what changes due to vapor condensation might be expected in airfoil measurements. Density measurements on circular-arc airfoils aided by an interferometer in choked tunnels with parallel walls show that increasing humidity produces increasing changes in the flow field. The flow becomes nonstationary at high humidity. At the airfoil, however, the influence of the condensation is only felt, inasmuch as the shock bounding the local supersonic region moves upstream with increasing humidity while its intensity decreases. The density distribution upstream of the shock remains unchanged. Even if the flow becomes nonstationary in the vicinity of the airfoil, no changes occur at the airfoil.

Schmidt, B.↗