Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical apparatus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Transport Phenomena in Thin Rotating Liquid Films Including: Nucleate Boiling

In this grant, experimental, numerical and analytical studies of heat transfer in a thin liquid film flowing over a rotating disk have been conducted. Heat transfer coefficients were measured experimentally in a rotating disk heat transfer apparatus where the disk was heated from below with electrical resistance heaters. The heat transfer measurements were supplemented by experimental characterization of the liquid film thickness using a novel laser based technique. The heat transfer measurements show that the disk rotation plays an important role on enhancement of heat transfer primarily through the thinning of the liquid film. Experiments covered both momentum and rotation dominated regimes of the flow and heat transfer in this apparatus. Heat transfer measurements have been extended to include evaporation and nucleate boiling and these experiments are continuing in our laboratory. Empirical correlations have also been developed to provide useful information for design of compact high efficiency heat transfer devices. The experimental work has been supplemented by numerical and analytical analyses of the same problem. Both numerical and analytical results have been found to agree reasonably well with the experimental results on liquid film thickness and heat transfer Coefficients/Nusselt numbers. The numerical simulations include the free surface liquid film flow and heat transfer under disk rotation including the conjugate effects. The analytical analysis utilizes an integral boundary layer approach from which

Faghri, Amir↗

Improved apparatus for continuous culture of hydrogen-fixing bacteria

Improved apparatus permits the continuous culture of Hydrogenomonas eutropha. System incorporates three essential subsystems - /1/ environmentally isolated culture vessel, /2/ analytical system with appropriate sensors and readout devices, /3/ control system with feedback responses to each analytical measurement.

Foster, J. F.↗

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge (SCGD) spectrometry apparatus may comprise an SCGD source and a mass or ion mobility spectrometer. A method for ionizing a molecular analyte may comprise contacting the molecular analyte with a plasma discharge to form ions and separating the ions in a mass spectrometer or ion mobility spectrometer. The contacting step may occur under atmospheric pressure and/or ambient conditions. The molecular analyte may be fragmented by the plasma discharge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stresses and deformations in angle-ply composite tubes

The stress and deformations in angle-ply composite tubes subjected to axisymmetric thermal loading were investigated both experimentally and analytically. For the theoretical portion a generalized plane strain elasticity analysis was developed. The analysis included mechanical and thermal loading, and temperature-dependent material properties. The elasticity analysis was also used to study the effect of including a thin metallic coating on a graphite-epoxy tube. The stresses in the coatings were found to be quite high, exceeding the yield stress of aluminum. An important finding in the analytical studies was the fact that even tubes with a balanced-symmetric lamination sequence exhibit shear deformation, or twist. For the experimental portion an apparatus was developed to measure torsional and axial response in the temperature range of 140 to 360 K. Eighteen specimens were tested, combining three material systems, eight lamination sequences, and three off-axis ply orientation angles. For the twist response, agreement between analysis and experiment was found to be good. The axial response of the tubes tested was found to be greater than predicted by a factor of three. As a result, it is recommended that the thermally induced axial deformations be investigated, both experimentally and analytically.

Rousseau, Carl Q.↗

Comparing and contrasting In-Vial and full-scale systems for sparging volatile analytes

Here, in-vial sparging was demonstrated as an effective, practical alternative to a full-scale sparging system for supporting the analysis of volatile constituents. Using elemental mercury (Hg 0 ) and toluene as representative purgeable analytes, the mass removal for various sparge configurations was measured and a reduced order model was developed and validated. In the primary experiments, Hg 0 in the sparge gas was trapped on activated carbon or gold, thermally desorbed, and quantified using atomic absorption or atomic fluorescence spectroscopy. Toluene experiments using the same in-vial sparge apparatus and sparge parameters were performed to demonstrate the applicability of the reduced order model to a broad range of compounds. Toluene removal was tracked by measuring the remaining toluene in sparged aliquots using Ultraviolet-visible (UV–Vis) spectroscopy. For the sparging, flow rates varied from 25 to 75 mL/min for periods from 0 to 30 min. Sparge performance, mass removal as a function of time, and sparge gas volume were measured for both in-vial and full-scale systems. A model based on dimensionless Henry's Law coefficient, normalized sparge gas volume, and fractional extent of equilibrium matched the experimental data for both compounds and provides a practical tool for future applications. For the conditions tested in this study, the calibrated model indicated that the sparge gas in the in-vial system reached approximately 33% of its equilibrium value before exiting the water surface, while a full-scale system reached approximately 100%. The tests validated the quality, reproducibility, and predictability of sparging performance for both full scale and in-vial sparge systems. Related factors such as waste generation, worker risk, and labor were also assessed. Full scale sparge systems provide the advantage of lower detection levels due to larger sample volume, while the in-vial sparge systems provide advantages for most other factors; including automatability, reducing secondary wastes, lessening the need to clean and check the sparge apparatus, and lowering labor and costs. The data and associated reduced order model support continued development and deployment of in-vial sparge platforms as a practical option for analysis of purgeable analytes such as volatile organic compounds and volatile metals/organometallics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the Generation-2 Dechlorination Apparatus for Treating Salt Wastes

This document satisfies the requirements for two milestones, i.e., M2FT-21PN030103021 and M3FT-21PN030103026, which are described in detail below. Also, details for the work package at the Pacific Northwest National Laboratory (PNNL) are provided below. The goal of this milestone was to demonstrate the generation-2 dechlorination apparatus (G2DA) for removing Cl from chloride-based electrochemical salt simulants. The two salts chosen for this initial study were KCl to simulate a component from the eutectic salt (LiCl is harder to detect with analytical instruments) and CsCl to simulate a fission product chloride that might be present in these types of waste streams. The overall scope of this work included receiving, installing, and testing the G2DA. This new system was designed to address several shortcomings identified with the generation-1 apparatus (G1DA), which are described in detail within this document. The G2DA was designed to address all of these shortcomings. The studies presented in here show that the G2DA worked as intended and will help provide scaled-up batches for additional testing at Argonne National Laboratory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method and apparatus for distributed sensing of volatiles using a long period fiber grating sensor with modulated plastic coating for environmental monitoring

Optical time domain reflectometry caused by absorption of a volatile or analyte into the fiber optic cladding is used as an optical nose. The fiber optics (14) are covered with a gas permeable film (44) which is patterned to leave millimeter wide gas permeable notches (48a-48d). The notches contain a sensing polymer that responds to different gases by expanding or contracting.

Ponce, Adrian↗

Acoustic emission from a growing crack

An analytical method is being developed to determine the signature of an acoustic emission waveform from a growing crack and the results of this analysis are compared to experimentally obtained values. Within the assumptions of linear elastic fracture mechanics, a two dimensional model is developed to examine a semi-infinite crack that, after propagating with a constant velocity, suddenly stops. The analytical model employs an integral equation method for the analysis of problems of dynamic fracture mechanics. The experimental procedure uses an interferometric apparatus that makes very localized absolute measurements with very high fidelity and without acoustically loading the specimen.

Jacobs, Laurence J.↗

An investigation of the information propagation and entropy transport aspects of Stirling machine numerical simulation

Aspects of the information propagation modeling behavior of integral machine computer simulation programs are investigated in terms of a transmission line. In particular, the effects of pressure-linking and temporal integration algorithms on the amplitude ratio and phase angle predictions are compared against experimental and closed-form analytic data. It is concluded that the discretized, first order conservation balances may not be adequate for modeling information propagation effects at characteristic numbers less than about 24. An entropy transport equation suitable for generalized use in Stirling machine simulation is developed. The equation is evaluated by including it in a simulation of an incompressible oscillating flow apparatus designed to demonstrate the effect of flow oscillations on the enhancement of thermal diffusion. Numerical false diffusion is found to be a major factor inhibiting validation of the simulation predictions with experimental and closed-form analytic data. A generalized false diffusion correction algorithm is developed which allows the numerical results to match their analytic counterparts. Under these conditions, the simulation yields entropy predictions which satisfy Clausius' inequality.

Goldberg, Louis F.↗

Large Deformation Behavior of Long Shallow Cylindrical Composite Panels

An exact solution is presented for the large deformation response of a simply supported orthotropic cylindrical panel subjected to a uniform line load along a cylinder generator. The cross section of the cylinder is circular and deformations up to the fully snapped through position are investigated. The orthotropic axes are parallel to the generator and circumferential directions. The governing equations are derived using laminated plate theory, nonlinear strain-displacement relations, and applying variational principles. The response is investigated for the case of a panel loaded exactly at midspan and for a panel with the load offset from midspan. The mathematical formulation is one dimensional in the circumferential coordinate. Solutions are obtained in closed-form. An experimental apparatus was designed to load the panels. Experimental results of displacement controlled tests performed on graphite-epoxy curved panels are compared with analytical predictions.

Carper, Douglas M.↗

Non-invasive glucose monitor

A non-invasive method for determining blood level of an analyte of interest, such as glucose, comprises: generating an excitation laser beam (e.g., at a wavelength of 700 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor in the anterior chamber is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated aqueous humor; and then determining the blood glucose level (or the level of another analyte of interest) for the subject from the Raman spectrum. Preferably, the detecting step is followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing method is also disclosed.

Lambert, James L.↗

Assessing blood brain barrier dynamics or identifying or measuring selected substances or toxins in a subject by analyzing Raman spectrum signals of selected regions in the eye

A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier. Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam (e.g., at a wavelength of 600 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

Lambert, James L.↗

Assessing blood brain barrier dynamics or identifying or measuring selected substances, including ethanol or toxins, in a subject by analyzing Raman spectrum signals

A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier.Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam at a selected wavelength (e.g., at a wavelength of about 400 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

Lambert, James L.↗

Analytical Performance, Loads, and Aeroelastic Stability of a Full-Scale Isolated Proprotor

The prediction of the performance and loads of a full-scale isolated proprotor and the calculation of whirl flutter stability of the rotor installed in a wind tunnel are considered in this study. The comprehensive analysis CAMRAD II is used. The test article is a research proprotor based on the Bell 609 rotor and the wind tunnel test apparatus is the newly developed Tiltrotor Test Rig (TTR) installed in the USAF NFAC 40- by 80-Foot Wind Tunnel. The performance and loads predictions and the stability calculations cover the following operating conditions: hover, cruise, conversion, and helicopter mode. These pre-test analytical results are being obtained to identify test operating limits, ensure a safe wind tunnel test and predict test results. Eventually, the goal is to perform a correlation study, identify shortfalls in the analytical model and introduce improvements to the analytical model. Performance and loads test results to date show that rotor torque (and yoke lag moment) may limit the test envelope. Shake test data based stability analysis shows that the TTR/609 is solidly stable within the test envelope.

Proprotor↗

Nitric oxide formation in a lean, premixed-prevaporized jet A/air flame tube: An experimental and analytical study

An experimental and analytical study was performed on a lean, premixed-prevaporized Jet A/air flame tube. The NO(x) emissions were measured in a flame tube apparatus at inlet temperatures ranging from 755 to 866 K (900 to 1100 F), pressures from 10 to 15 atm, and equivalence ratios from 0.37 to 0.62. The data were then used in regressing an equation to predict the NO(x) production levels in combustors of similar design. Through an evaluation of parameters it was found that NO(x) is dependent on adiabatic flame temperature and combustion residence time, yet independent of pressure and inlet air temperature for the range of conditions studied. This equation was then applied to experimental data that were obtained from the literature, and a good correlation was achieved.

Lee, Chi-Ming↗

Experimental unsteady pressures at flutter on the Supercritical Wing Benchmark Model

This paper describes selected results from the flutter testing of the Supercritical Wing (SW) model. This model is a rigid semispan wing having a rectangular planform and a supercritical airfoil shape. The model was flutter tested in the Langley Transonic Dynamics Tunnel (TDT) as part of the Benchmark Models Program, a multi-year wind tunnel activity currently being conducted by the Structural Dynamics Division of NASA Langley Research Center. The primary objective of this program is to assist in the development and evaluation of aeroelastic computational fluid dynamics codes. The SW is the second of a series of three similar models which are designed to be flutter tested in the TDT on a flexible mount known as the Pitch and Plunge Apparatus. Data sets acquired with these models, including simultaneous unsteady surface pressures and model response data, are meant to be used for correlation with analytical codes. Presented in this report are experimental flutter boundaries and corresponding steady and unsteady pressure distribution data acquired over two model chords located at the 60 and 95 percent span stations.

Dansberry, Bryan E.↗

Thermomechanical Response of Shape Memory Alloy Hybrid Composites

This study examines the use of embedded shape memory alloy (SMA) actuators for adaptive control of the thermomechanical response of composite structures. A nonlinear thermomechanical model is presented for analyzing shape memory alloy hybrid composite (SMAHC) structures exposed to steady-state thermal and dynamic mechanical loads. Also presented are (1) fabrication procedures for SMAHC specimens, (2) characterization of the constituent materials for model quantification, (3) development of the test apparatus for conducting static and dynamic experiments on specimens with and without SMA, (4) discussion of the experimental results, and (5) validation of the analytical and numerical tools developed in the study. Excellent agreement is achieved between the predicted and measured SAMHC responses including thermal buckling, thermal post-buckling and dynamic response due to inertial loading. The validated model and thermomechanical analysis tools are used to demonstrate a variety of static and dynamic response behaviors including control of static (thermal buckling and post-buckling) and dynamic responses (vibration, sonic fatigue, and acoustic transmission). and SMAHC design considerations for these applications. SMAHCs are shown to have significant advantages over conventional response abatement approaches for vibration, sonic fatigue, and noise control.

Turner, Travis L.↗

Small Particle Response to Fluid Motion using Tethered Particles to Simulate Microgravity

This paper reports on ground based work conducted to support the Spaceflight Definition project SHIVA (Spaceflight Holography Investigation in a Virtual Apparatus). SHIVA will advance our understanding of the movement of a particle in a fluid. Gravity usually dominates the equations of motion, but in microgravity as well as on earth other terms can become important. Before two members of our team found an analytical solution of the equations, numerical methods and/or neglecting terms were required. The general solution predicts that the usually neglected history term becomes important when the characteristic viscous time is in the same order as the vibration period and peaks when the two times are equal. In this case three force terms, the Stokes drag, the added mass, and the history drag must all be included in predicting particle movement. We also developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the "virtual apparatus". Using state-of-the-art methods in holography we will quantify the three-dimensional motion of sets of particles, allowing us to test and apply the new analytical solutions. The motion of particles up to 4 mm in diameter in a fluid that oscillates at frequencies up to 100 Hz with amplitudes up to 200 microns is being examined. Ground studies to support the flight development program have employed various schemes to simulate microgravity. One of the most reliable and meaningful methods uses spheres tethered to a fine hair suspended in the fluid. We have also investigated particles with nearly neutral buoyancy. Recordings are made at the peak amplitudes of vibration of the cell providing a measure of the ratio of fluid to particle amplitude. The experiment requires precise location of the particle at the time of recording. The hologram of the particle provides microscopic images of the particle that are used for finding the position with an accuracy of a few microns. To make the experiment more versatile, the spaceflight system will record holograms both on film and electronically. The electronic holograms can be downlinked providing real time data. Results of the ground experiments, the flight experiment design, and data analysis procedures are reported.

Trolinger, J. D.↗