The effect of ambient conditions on carbon monoxide emissions from an idling gas turbine combustor

A test program employing a gas turbine combustor is outlined; the results of which quantize the effects of changes in ambient temperature and humidity on carbon monoxide emissions at simulated idle operating conditions. A comparison of the experimental results with analytical results generated by a kinetic model of the combustion process, and reflecting changing ambient conditions, is given. It is demonstrated that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine at idle, and that the analytical model is reasonably successful in predicting changes.

Subramanian, A. K.↗

Investigation of Power Requirements for Ice Prevention and Cyclical De-Icing of Inlet Guide Vanes with Internal Electric Heaters

An investigation was conducted to determine the electric power requirements necessary for ice protection of inlet guide vanes by continuous heating and by cyclical de-icing. Data are presented to show the effect of ambient-air temperature, liquid-water content, air velocity, heat-on period, and cycle times on the power requirements for these two methods of ice protection. The results showed that for a hypothetical engine using 28 inlet guide vanes under similar icing conditions, cyclical de-icing can provide a total power saving as high as 79 percent over that required for continuous heating. Heat-on periods in the order of 10 seconds with a cycle ratio of about 1:7 resulted in the best over-all performance with respect to total power requirements and aerodynamic losses during the heat-off period. Power requirements reported herein may be reduced by as much as 25 percent by achieving a more uniform surface-temperature distribution. A parameter in terms of engine mass flow, vane size, vane surface temperature, and the icing conditions ahead of the inlet guide vanes.was developed by which an extension of the experimental data to icing conditions and inlet guide vanes, other than those investigated was possible.

VonGlahn, Uwe↗

Evaluation of two transport aircraft and several ground test vehicle friction measurements obtained for various runway surface types and conditions. A summary of test results from joint FAA/NASA Runway Friction Program

Tests with specially instrumented NASA Boeing 737 and 727 aircraft together with several different ground friction measuring devices were conducted for a variety of runway surface types and conditions. These tests are part of joint FAA/NASA Aircraft/Ground Vehicle Runway Friction Program aimed at obtaining a better understanding of aircraft ground handling performance under adverse weather conditions and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow and ice-covered runway conditions is discussed as well as ground vehicle friction data obtained under similar runway conditions. For a given contaminated runway surface condition, the correlation between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, type and amount of surface contaminant, and ambient temperature are discussed. The effect of surface type on wet friction levels is also evaluated from comparative data collected on grooved and ungrooved concrete and asphalt surfaces.

Yager, Thomas J.↗

Fecundity of Quail in Spacelab Microgravity

Flight experiments in which fertilized Japanese quail eggs were allowed to develop to various ages in space, and the results of the following laboratory tests are described. Laboratory-based experiments concerned with the embryonic development of Japanese quail in gravity using simulated vibrations and G-force are reported. Effect of turning and ambient temperature at various days of incubation on the development of Japanese quail, and method to feed and water adult and newly hatched Japanese quail in microgravity using a gelatin-based diet as a solid water supply, are also described.

Wentworth, B. C.↗

Testing of a Neon Loop Heat Pipe for Large Area Cryocooling

Cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks is required for future NASA missions. A cryogenic loop heat pipe (CLHP) can provide a closed-loop cooling system for this purpose and has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A neon CLHP was tested extensively in a thermal vacuum chamber using a cryopump as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components. Tests conducted included loop cool-down from the ambient temperature, startup, power cycle, heat removal capability, loop capillary limit and recovery from a dry-out, low power operation, and long duration steady state operation. The neon CLHP demonstrated robust operation. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by applying power to both the pump and evaporator without any pre-conditioning. It could adapt to changes in the pump power andor evaporator power, and reach a new steady state very quickly. The evaporator could remove heat loads between 0.25W and 4W. When the pump capillary limit was exceeded, the loop could resume its normal function by reducing the pump power. Steady state operations were demonstrated for up to 6 hours. The ability of the neon loop to cool large areas was therefore successfully verified.

Cryogenics↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

Design screening and analysis of gas-fired ammonia-based chemisorption heat pumps for space heating in cold climate

Thermally-driven ammonia-based chemisorption heat pumps (CSHP) have the potential to provide high-efficiency space heating in cold climates. Using the reversible chemical bond between sorbent salt and ammonia, CSHP thermochemically pumps heat from the cold ambient to the end-uses of space heating at 50 °C. The heating coefficient of performance (COP) of a CSHP largely depends on the selection of the sorbent salts, cycle configuration, and the system operation. This study uses a thermodynamic model to investigate the performance of six CSHP system configurations, including four single-effect and two double-effect cycles. The feasibility and performance of 121 available NH 3 /salt reactions are studied for each configuration. The thermal COP of the cycles and the primary energy COP of the gas-fired CSHP systems are evaluated assuming 50 °C supply temperature for building space heating and the optimal system designs are identified. The highest thermal COP for single-effect and double-effect cycles under -25 °C ambient temperatures are predicted to be 1.22 and 1.57, respectively. The corresponding primary energy COPs are above 1.0 and 1.15, which are 30% higher than condensing furnaces and is sustained into the same cold temperatures.

42 ENGINEERING↗

Effects of thermal and environmental exposure on the mechanical properties of graphite/polyimide composites

Composites were exposed in circulating and static air environments up to 589 K for a maximum of 1000 hours. Composites of HT-S, HM-S, Thornel 50S, and Fortafil 5-Y fiber and a new addition type polyimide resin were laminated in a matched-die mold. Flexural strengths, flexural modulus, and interlaminar shear strengths were determined at 297, 533, and 598 K after various durations of exposure. Composite and fiber weight loss characteristics were determined by isothermal gravimetric analysis in air. Properties of composites exposed and tested at the environment temperatures were compared with those determined under short-term exposure. A new short beam interlaminar shear fixture is described. Environmental effects of long-term ambient temperature exposure on the elevated temperature mechanical properties of graphite/polyimide composites are presented.

Hanson, M. P.↗

Experimental investigation of low velocity and high temperature solid particle impact erosion wear

Next generation Concentrating Solar Power (CSP) plants utilizing solid particles as the heat transfer medium (HTM) are expected to achieve greater operational efficiencies. However, the erosion from the solid particles can cause significant damage to component materials. Low particle speeds (1–2 m/s) are proposed as a means of preventing excessive damage to containment materials. Within the current investigation, solid particle erosion of three potential containment materials, stainless-steel grade 316L, a nickel alloy (Inconel 740H), and a refractory material (Tufcrete 60 M), are examined at a particle impact speed of 1.6 m/s. CarboBead-HSP 40/70 particles, a candidate HTM for CSP systems, impact the specimens at a relatively high impact angle of 60° based on containment design criteria. Experiments were conducted at ambient temperature and 800 °C to examine erosion of the materials at very low impact speeds and determine how temperature effects erosion. Initial results revealed surprising outcomes inconsistent with available literature: ambient temperature erosion of SS316L is an order of magnitude lower than IN740H, but erosion (erosion-corrosion) of SS316L at 800 °C surpasses IN740H by two orders of magnitude. Furthermore, results suggest removal of oxide layers (erosion-corrosion) is responsible for the significant erosion that was observed even at these low particle speeds.

36 MATERIALS SCIENCE↗

Effect of Anode Porosity and Temperature on the Performance and Lithium Plating During Fast-Charging of Lithium-Ion Cells

Twenty-four single-layer approximate to 32 mAh pouch cells are tested to determine the effect of electrode porosity on lithium plating. Twelve cells contain a graphite electrode that is 26% porous, and 47% for the other twelve. The cells are cycled using a 6-C charge and a C/2 discharge protocol at temperatures in the range of 20-50 degrees C. A macro-homogeneous electrochemical model and microstructure analysis tool set are used to help interpret experimental observations for the effect of anode porosity and ambient temperature on fast-charging performance. Additionally, comparison between the two also highlights gaps in current theoretical understanding that need to be addressed. In post-test examination, lithium plating is seen in all cells, regardless of porosity. Elevated temperature is shown to reduce the amount of lithium plating and improve initial fast-charge capacity, but also changes the rate of other, less well-understood degradation mechanisms. Apparent kinetic rate laws, At + Bt 1/2 , where A and B are constants, can be fit to most of the capacity loss and resistance increase data. The relative magnitudes of A and B change with temperature and porosity. The capacity loss data at 50 degrees C from the high-porosity cells are fit by a logistics rate law.

25 ENERGY STORAGE↗

IDENTIFICATION OF ADSORBA TION OF ADSORBATE FT-IR BANDS USING IN-SI -IR BANDS USING IN-SITU TECHNIQUES: Pd SPECIATION AND ADSORPTION CHEMISTRY OF Pd-ZEOLITES FOR PASSIVE NOx ADSORPTION

To meet increasingly stringent automotive emissions standards, further improvements in catalytic converter design are necessary. Current automotive catalyst systems are effective at eliminating emission of nitrogen oxides (NOx) once the catalyst reaches operational temperature (~200 °C). NOx emitted at lower catalyst temperatures now comprises most of the NOx released during a typical test cycle. Referred to as “the cold start problem” this issue has come to the forefront of automotive catalyst development, as mitigating these emissions is necessary to further reduce automotive emissions. Passive NOx adsorbers present an appealing solution to the cold start problem, these being a class of materials that chemisorb exhaust components such as NOx, carbon monoxide (CO) and hydrocarbons at near-ambient temperatures, and then desorb these compounds once the downstream catalyst has reached operational temperature. An effective passive NOx adsorber must have several properties: high NOx adsorption at near-ambient temperatures, near-complete NOx desorption at temperatures within the operational range, high thermal stability, and resistance to automotive exhaust components at high temperatures. The potential environmental impact of such a system is substantial, as NOx emissions currently result in the formation of millions of tons of smog and acid rain each year. Pd-exchanged zeolites have shown promise for deployment as Passive NOx adsorbers, though much remains to be understood about their adsorption chemistry and deactivation. In-situ Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) provides a convenient probe of adsorbed species, most automotive exhaust components possessing IR-active chemical bonds. By examining the evolution of IR bands under various pretreatments and adsorbates, the overall Pd-speciation and adsorptive zeolite sites of each material can be characterized, and the identities of IR bands can be deduced. In this work, microreactor-MS analysis of the adsorption and desorption behavior of these materials was also examined, these results being coupled with in-situ DRIFTS temperature programmed desorption (TPD) to correlate desorption events with specific adsorbed species. A pair of zeolite frameworks of similar Si/Al ratio but differing pore size were examined, Beta zeolite (BEA) and Chabazite (CHA) representing a medium- and small-pore framework, respectively. The effect of Pd-loading on BEA was examined, as well as the various deactivation pathways and active sites of each material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A computer solution for the dynamic load, lubricant film thickness and surface temperatures in spiral bevel gears

A complete analysis of spiral bevel gear sets is presented. The gear profile is described by the movements of the cutting tools. The contact patterns of the rigid body gears are investigated. The tooth dynamic force is studied by combining the effects of variable teeth meshing stiffness, speed, damping, and bearing stiffness. The lubrication performance is also accomplished by including the effects of the lubricant viscosity, ambient temperature, and gear speed. A set of numerical results is also presented.

Chao, H. C.↗

Investigation of low temperature carbon monoxide oxidation catalysts

Carbon monoxide generation rates related to the use of commerical equipment in Spacelab, added to the normal metabolic and subsystem loads, will produce carbon monoxide levels in excess of the maximum allowable concentration. In connection with the sensitivity of carbon monoxide oxidation catalysts to poisoning at room temperature, catalysts for an oxidation of carbon monoxide at low temperatures have been investigated. It was found that platinum and palladium are the only effective room temperature catalysts which are effective at 333 K. Hopcalite was ineffective at ambient temperatures, but converted CO with 100 percent efficiency at 333 K. Poisoning tests showed the noble metal catalysts to be very sensitive, and Hopcalite to be very resistant to poisoning.

Jagow, R. B.↗

Compression studies on particulate composites of ternary Al-Ti-Fe, and quaternary Al-Ti-Fe-Nb and Al-Ti-Fe-Mn L1(2) compounds

Compression studies were conducted on monolithic and TiB2 particulate-reinforced composites of Al22Fe3Ti8, both with and without minor quaternary alloying additions (2 at. pct Nb and 2 at. pct Mn) as a function of temperature and as a function of strain rate at high temperature. The volume fraction of reinforcement was varied between 0 and 20 percent. The particulate reinforcements were found to be effective in increasing ambient- and warm-temperature strength; at high temperatures, the monolithic material is stronger than the composites, although the composites are superior at slow strain rates. The microstructures of the monolithic and composite specimens were examined before and after deformation to explain these observations.

Kumar, K. S.↗

Effects of Ambient Conditions on Helicopter Harmonic Noise Radiation: Theory and Experiment

The effects of ambient atmospheric conditions, air temperature, and density on rotor harmonic noise radiation are characterized using theoretical models and experimental measurements of helicopter noise collected at three different test sites at elevations ranging from sea level to 7000 ft above sea level. Significant changes in the thickness, loading, and blade–vortex interaction noise levels and radiation directions are observed across the different test sites for an AS350 helicopter flying at the same indicated airspeed and gross weight. However, the radiated noise is shown to scale with ambient pressure when the flight condition of the helicopter is defined in nondimensional terms. Although the effective tip Mach number is identified as the primary governing parameter for thickness noise, the nondimensional weight coefficient also impacts lower harmonic loading noise levels, which contribute strongly to low-frequency harmonic noise radiation both in and out of the plane of the horizon. Strategies for maintaining the same nondimensional rotor operating condition under different ambient conditions are developed using an analytical model of single main rotor helicopter trim and confirmed using a CAMRAD II model of the AS350 helicopter. The ability of the Fundamental Rotorcraft Acoustics Modeling from Experiments (FRAME) technique to generalize noise measurements made under one set of ambient conditions to make accurate noise predictions under other ambient conditions is also validated.

rotorcraft↗