Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermal conversion in air of rare-earth fluorides to rare-earth oxyfluorides and rare-earth oxides

Phase transformations of seven different rare-earth fluorides (i.e., REF3) where RE = La, Ce, Pr, Nd, Tm, Yb, Lu at temperatures ranging from 400–1400°C in air were investigated with X-ray diffraction. All of the REF3 compounds first transformed to oxyfluorides and then to oxides, with the exception of CeF3, which transformed directly to an oxide. This study focuses on the phase transitions of REF3 to REOx by simple heat-treatment processes in air and shows plausibility to remove RE elements from fluoride salt streams from molten salt reactors through fluoride-to-oxyfluoride or fluoride-to-oxide conversion mechanisms, which will result in precipitation. This could be used to remove fission product poisons from molten salt reactor waste streams. A waste form option for the resulting REOx products is lanthanide aluminoborosilicate (LABS) glass. To demonstrate this NdF3 was converted to Nd2O3 and immobilized in a LABS glass.

oxyfluoride, molten salt reactors, fluoride salt w↗

Propagation of positive discharges in an air bubble having an embedded water droplet

Low temperature plasmas generated inside gas bubbles immersed in water is an effective method of rapidly transferring plasma generated reactive species to the water for applications in biomedicine, agriculture and environment. Reactive species are generally produced in the gas phase plasma and then solvate into the liquid. The large surface-to-volume ratio (SVR) of the bubble accelerates this process. In generating bubbles in water, aerosols and droplets are also contained within the bubble. These droplets also have a large SVR and so can be rapidly plasma activated. However, the presence of the droplets can also impact the propagation of the plasma in the bubble. In this paper, results are discussed from computational and experimental investigations of the formation and evolution of discharges in an air bubble immersed in water with an embedded water droplet. The computations were performed with a two-dimensional plasma hydrodynamics model. Experiments were performed with a quasi-2D bubble apparatus. In bubbles having a droplet, a plasma filament typically bridges from the powered electrode to the droplet, and then from the droplet to the bubble surface. A surface-hugging streamer also occurs on the inner bubble surface and on the surface of the droplet. Both surface streamers result in part from surface charge accumulation and can dominate the formation of reactive species that transport into the droplet. Increasing droplet conductivity suppresses propagation of the surface discharge and leads to a lower density of aqueous reactive species. Increasing conductivity of the surrounding water does not change the overall structure of the discharge but does slightly elevate the discharge intensity. Finally, the size and shape of the embedded droplet can significantly affect the formation and propagation of the streamer.

2D fluid modelling↗

Heat Transfer Characteristics of Particle and Air Flow Through Additively Manufactured Lattice Frame Material Based on Octet-Shape Topology

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchanger is a critical component in next-generation concentrating solar power (CSP) plants. The inherently low heat transfer between falling particles and sCO 2 imposes a challenge toward economic justification of levelized cost of electricity produced through solar energy. Introduction of integrated porous media with the walls bounding particle flow has the potential to enhance the overall particle-to-sCO 2 heat exchanger performance. Here, this paper presents an experimental study on heat transfer characterization of additively manufactured lattice frame material based on Octet-shaped unit cell with particles and air as working fluids. The lattice structures were additively manufactured in stainless steel (SS) 316L and SS420 (with 40% bronze infiltration) via Binder jetting process, where the lattice porosities were varied between 0.75 and 0.9. The mean particle diameters were varied from 266 μm to 966 μm. The effective thermal conductivity and averaged heat transfer coefficient were determined through steady-state experiments. It was found that the presence of lattice enhances the effective thermal conductivity by 2–4 times when compared to packed bed of particles alone. Furthermore, for gravity-assisted particle flow through lattice panel, significantly high convective heat transfer coefficients ranging from 200 W/m2K to 400 W/m2K were obtained for the range of particle diameters tested. The superior thermal transport properties of Octet-shape-based lattice frame for particle flow makes it a very promising candidate for particle-to-sCO 2 heat exchanger for CSP application.

14 SOLAR ENERGY↗

Characterizing NWP Model Errors Using Doppler-Lidar Measurements of Recurrent Regional Diurnal Flows: Marine-Air Intrusions into the Columbia-River Basin

Ground-based Doppler-lidar instrumentation provides atmospheric wind data at dramatically improved accuracies and spatial/temporal resolutions. These capabilities have provided new insights into atmospheric flow phenomena, but they also should have a strong role in NWP model improvement. Insight into the nature of model errors can be gained by studying recurrent atmospheric flows, here a regional summertime diurnal sea breeze and subsequent marine-air intrusion into the arid interior of Oregon-Washington, where these winds are an important windenergy resource. These marine intrusions were sampled by three scanning Doppler lidars in the Columbia-River Basin as part of the Second Wind Forecast Improvement Project (WFIP2), using data from summer 2016. Lidar time-height cross sections of wind speed identified eight days when the diurnal-flow cycle, (peak wind speeds at midnight, afternoon minima) was obvious and strong. Eight-day composite time-height cross sections of lidar wind speeds are used to validate those generated by the operational NCEP-HRRR model. HRRR simulated the diurnal wind cycle, but produced errors in the timing of onset and significant errors due to a premature nighttime demise of the intrusion flow, producing low-bias errors of 6 m s-1 . Day-to-day and in the composite, whenever a marine intrusion occurred, HRRR made these same errors. The errors occurred under a range of gradient wind conditions indicating that they resulted from the misrepresentation of physical processes within a limited region around the measurement locations. Because of their generation within a limited geographical area, field-measurement programs can be designed to find and address the sources of these NWP errors.

Banta, Robert M.↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on a vapor slipstream from the Hanford AX tank farm exhauster. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing on AX exhauster slipstream vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Climate-focused Life Cycle Assessments of Biochar Production by an ARTi Pyrolysis Reactor and an Air Burners CharBoss® Air Curtain Incinerator

This report presents a limited, dynamic, consequential life cycle assessment (LCA) to compare the climate impacts of two biochar production methods using wood as a feedstock. The two methods are a pyrolysis reactor supplied by ARTi (Des Moines, IA, https://www.arti.com/) and a T26 CharBoss® air curtain incinerator supplied by Air Burners, Inc. (Palm City, FL, https://airburners.com/). The underlying LCA methodology is described in a chapter by Singh et al. (2024) and implemented in the form of a workbook freely available as online Supplementary Material for the chapter. For the convenience of the reader, a pre-print version of the relevant portions of Singh et al. (2024) is attached as Appendix A to this report. Specific assumptions and calculations to obtain the input parameters used in this LCA for each production method are described in the Methodology section below. This implementation of the LCA considers emissions associated with biomass loading, comminution and conversion, biochar decay in soil, and the production and use of bioenergy generated during the conversion process. The LCA is “limited” in that upstream emissions associated with biomass production, harvest, transportation, and land-use change, as well as embodied emissions in equipment and facilities are not considered. Similarly, downstream emissions from biochar transport and incorporation into soil (i.e., tillage), and the impact of biochar soil amendments on soil greenhouse gas (GHG) emissions (other than CO 2 from biochar decay in soil), soil organic carbon stocks, crop response, and surface albedo are not considered. As the intent is to compare different biochar production methods in a simple unbiased manner, the primary alternative biomass pathway for the LCA is immaculate combustion, which is the hypothetical instantaneous and complete conversion of carbon in the biomass to CO 2 at time zero without generation of any other greenhouse gases or aerosols (GHGAs) or any useful bioenergy. Use of this pathway provides relative values for the production methods and, when the embodied emissions are similar and the same feedstock is used, these relative values are reasonable approximations for those attained with a full LCA.

09 BIOMASS FUELS↗

Composition, Emissions, and Air Quality Impacts of Hazardous Air Pollutants in Unburned Natural Gas from Residential Stoves in California

The presence of hazardous air pollutants (HAPs) entrained in end-use natural gas (NG) is an understudied source of human health risks. We performed trace gas analyses on 185 unburned NG samples collected from 159 unique residential NG stoves across seven geographic regions in California. Our analyses commonly detected 12 HAPs with significant variability across region and gas utility. Mean regional benzene, toluene, ethylbenzene, and total xylenes (BTEX) concentrations in end-use NG ranged from 1.6–25 ppmv–benzene alone was detected in 99% of samples, and mean concentrations ranged from 0.7–12 ppmv (max: 66 ppmv). By applying previously reported NG and methane emission rates throughout California’s transmission, storage, and distribution systems, we estimated statewide benzene emissions of 4,200 (95% CI: 1,800–9,700) kg yr –1 that are currently not included in any statewide inventories–equal to the annual benzene emissions from nearly 60,000 light-duty gasoline vehicles. Additionally, we found that NG leakage from stoves and ovens while not in use can result in indoor benzene concentrations that can exceed the California Office of Environmental Health Hazard Assessment 8-h Reference Exposure Level of 0.94 ppbv–benzene concentrations comparable to environmental tobacco smoke. This study supports the need to further improve our understanding of leaked downstream NG as a source of health risk.

42 ENGINEERING↗

Effect of Added Gadolinium Oxide on the Thermal Air Oxidation of Uranium Dioxide

To develop a more reliable and stable UO2-based nuclear fuel, the Pacific Northwest National Laboratory (PNNL) investigated modifying fuel with several soluble lanthanides and zirconium. This article provides the results of these studies investigating gadolinium doping at levels up to 10 mass%. The authors characterized and compared commercially- and PNNL-prepared gadolinium-doped UO2 to determine the oxygen-to-metal ratio, elemental distribution, chemical composition, physical appearance, lattice parameters, and grain structure using atomic force microscopy, scanning electron microscopy coupled with energy dispersive spectroscopy, and X-ray diffractometry. After confirming PNNL-prepared UO2 and (Gd,U)O2 were similar to commercially prepared UO2 and (Gd,U)O2, we measured the thermal behavior of these gadolinium-doped UO2 materials to air oxidation using differential scanning calorimetry and thermogravimetric analysis. Addition of gadolinium stabilized the first oxidation product U4¬O9/U3O7 and slowed the subsequent oxidation to U3O8. Comparison of our measured two-step oxidation of UO2 to U3O8 at 325°C to common gas/solid kinetic reaction models found that each oxidation step is best described as a convolution of kinetic behaviors; the gadolinium insertion into the UO2 lattice enforces a significant alteration in mechanism and oxidation rate. Noticeable changes in mechanism become apparent between 1% and 3% gadolinium content.

Uranium Dioxide, Gadolinium Oxide, Thermal Air Oxi↗

Specific Ion Effects in Lanthanide–Amphiphile Structures at the Air–Water Interface and Their Implications for Selective Separation

The use of surfactants to attract dissolved ions to water surfaces and interfaces is an essential step in both solvent-based and solvent-free separation processes. Here, we have studied the interactions of lanthanide ions in the aqueous subphase with monolayers of dihexadecyl phosphate at air–water interfaces. With heavier lanthanides (atomic number Z ≥ 65) in the subphase, the floating layer can be compressed to an area/molecule of about half the molecular cross section, indicating bilayer formation. X-ray fluorescence and reflectivity data support this conclusion. In the presence of lighter lanthanides (Z < 65), only monolayers are observed. Subphase-concentration-dependent studies using Er 3+ (heavier) and Nd 3+ (lighter) lanthanides show a stepwise progression, with ions attaching to the monolayer only when the solution concentration is >3 × 10 –7 M. Above ~10 –5 M, bilayers form but only in the presence of the heavier lanthanide. Grazing incidence X-ray diffraction shows evidence of lateral ion–ion correlations in the bilayer structure but not in monolayers. Explicit solvent all-atom molecular dynamics simulations confirm the elevated ion–ion correlation in the bilayer system. This bilayer structure isolates heavier lanthanides but not lighter lanthanides from an aqueous solution and is therefore a potential mechanism for the selective separation of heavier lanthanides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗