Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “absorption coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Study of the L (2,3) Edges of 3d Transition Metals By X-Ray Absorption Spectroscopy

In the soft X-rays energy region, near edge X-ray absorption fine structure (NEXAFS) spectra are generally recorded by monitoring yield signals of secondary particles. These secondary particles, electrons or fluorescence photons, follow from the decay of the core hole excited in the primary absorption process. In general the yield signals are, to a good approximation, proportional to the absorption coefficient. However, in several applications it would be desirable to measure the absorption coefficient quantitatively. To derive the absorption coefficient quantitatively from a yield spectrum, one needs to know the escape depth of the emitted electrons ({lambda}{sub e}) of the applied yield technique in the material of interest. Since this quantity is difficult to calculate, it is unknown for most materials. In this paper we present the first results of our systematic investigation of the total electron-yield (TEY) escape depth of the 3d transition metals (Fe, Co and Cu). In addition our results gave important information on the variation of the TEY escape depth with the filling of the 3d band.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Investigation on Transparency and Mechano-Acoustic Properties of Poly Methyl Methacrylate/Polycarbonate Based Nanocomposites

The main goal of this paper was to investigate transparency and mechano-acoustic properties of poly methyl methacrylate (PMMA)/polycarbonate (PC) based nanocomposites, reinforced with silica (SiO{sub 2}), zinc dioxide (ZnO), and titanium dioxide (TiO{sub 2}) nanoparticles. For this purpose, morphological, transparency, acoustical and mechanical tests were carried out on the specimens, prepared by melt-compounding method in a twin-screw extruder. The morphological test results confirmed uniform dispersion of the nanoparticles in the polymer matrix. The results also revealed that transparency of the PC and PMMA nanocomposites, characterized by the degree of light transmittance, was decreased by adding 0.3 wt% of the nanoparticles. Also, tensile modulus of the nanocomposite specimens was higher than that of neat PC and PMMA. Unlike the neat PC specimens, tensile strength showed a decrease in PMMA specimens. The presence of nanoparticles in the composites decreased mobility of polymer chains and consequently, reduced elongation at break in the specimens. After surface roughening process, noise absorption coefficient in PC/PMMA nanocomposite specimens (PCSI3-R, PMSI3-R, and PMZN3-R) showed a higher absorption coefficient than the other specimens in the dominant frequency of traffic noise (500 Hz). As conclusion, roughening the surface of materials would be one of the most important factors enhancing the absorption coefficient of some of the nanocomposites in the middle frequency. The rough surface of particles in the base matrix increases the absorption coefficient of the materials, especially in the frequency of 500 Hz, as the dominant frequency of noise traffic. The suggested materials are predestinated to be appropriate in building industry, particularly in the structure of noise barriers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Gamma-radiation-induced negative nonlinear absorption in quartz glass

The effect of ionizing radiation on the nonlinear optical properties of materials needs to be considered for applications that employ high-power laser pulses in extreme radiation environments. The Heraeus Infrasil302 optical quartz glass was irradiated by gamma rays, and its nonlinear absorption was measured using the open-aperture Z-scan technique with nanosecond laser pulses. Irradiation results in a negative nonlinear absorption coefficient whose magnitude increases with irradiation dose. Nonlinear absorption coefficients of -0.78, -1.14, -1.29, and -1.88~ × ~10 -13 m/W are measured for gamma doses of 600 krad, 1.2 Mrad, 3.6 Mrad, and 10 Mrad, respectively. Thermal annealing restores the optical properties of quartz-glass to their unirradiated values. It is suggested that metallic impurities introduced by the manufacturing process have a role in inducing saturated absorption in irradiated quartz glass, which manifests as negative nonlinear absorption coefficient, and is demonstrated by comparing Infrasil302 quartz results to equivalent irradiated measurements for Spectrosil2000 quartz.

07 ISOTOPE AND RADIATION SOURCES↗

Electronic and optical properties of mixed perovskites CsSn{sub x}Pb{sub (1−x)}I{sub 3}

The electronic structure and optical properties of the new solar cells absorber material: mixed perovskites CsSn{sub x}Pb{sub (1−x)}I{sub 3} are studied by the first-principle calculations with mBJ + SOC (modified Beak Johnson approximation plus spin-orbit coupling) method. The band gap of the serial of compounds almost quasi-linearly reduces with increasing Sn content from 0.96 eV (x = 0) to 0.16 eV (x = 1). Optical absorption coefficient revealed a progressive red shift with the increment of the Sn content, accompanying with the absorption edge broadening. The absorption coefficient and Ideal Power Absorption Coefficient (IPAC) increase greatly with the Pb atoms being partially substituted by Sn atoms. The pure CsSnI{sub 3} has the highest IPAC, but it is unstable in the air because the Sn{sup 2+} will be oxidized to Sn{sup 4+}. So our results indicate that partially substituted CsSn{sub x}Pb{sub (1−x)}I{sub 3} might be the good solar cell absorption material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-IR absorption in high-purity photothermorefractive glass and holographic optical elements: measurement and application for high-energy lasers

Volume Bragg gratings (VBGs) in photothermorefractive (PTR) glass are widely used for laser beam control including high-power laser systems. Among them, spectral beam combining based on VBGs is one of the most promising. Achieving 100+ kW of combined laser beams requires the development of PTR glass and VBGs with an extremely low absorption coefficient and therefore methods of its measurement. This paper describes the calorimetric method that was developed for measuring a low absorption coefficient in PTR glass and VBGs. It is based on transmission monitoring of the intrinsic Fabry-Perot interferometer produced by the plane-parallel surfaces of the measured optical elements when heated by high-power laser radiation. An absorption coefficient at 1085 nm as low as 5x10{sup -5} cm{sup -1} is demonstrated in pristine PTR glass while an absorption coefficient as low as 1x10{sup -4} cm{sup -1} is measured in high-efficiency reflecting Bragg gratings with highest purity. The actual level of absorption in PTR glass allows laser beam control at the 10 kW level, while the 100 kW level would require active cooling and/or decreasing the absorption in PTR Bragg gratings to a value similar to that in virgin PTR glass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo calculations of the extraction of scintillation light from cryogenic $N$-type GaAs

We report the high scintillation luminosity of n-type GaAs at 10 °K is surprising because (1) with a refractive index of 3.5, escape is inhibited by total internal reflection and (2) narrow-beam experiments at 90 °K report infrared absorption coefficients of several per cm. This paper presents Monte Carlo calculations showing that the high luminosity at 10 °K can be explained if (1) the narrow-beam absorption is almost all optical scattering and (2) the absolute absorption coefficient is below 0.1 per cm. Sixteen surface reflector configurations are simulated for a range of internal scattering and absolute absorption coefficients, and these can guide the design of cryogenic scintillating GaAs targets for the direct detection of dark matter. The discussion section presents a possible infrared scattering mechanism based on the metallic nature of n-type GaAs. A supplement file describes (1) the Monte Carlo program steps in detail and (2) how narrow-beam and integrating sphere experiments can measure the cryogenic optical scattering and absolute absorption coefficients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging

Purpose: The authors report on measurements of light output and spatial resolution of microcolumnar CsI:Tl scintillator detectors for x-ray imaging. In addition, the authors discuss the results of simulations aimed at analyzing the results of synchrotron and sealed-source exposures with respect to the contributions of light transport to the total light output. Methods: The authors measured light output from a 490-μm CsI:Tl scintillator screen using two setups. First, the authors used a photomultiplier tube (PMT) to measure the response of the scintillator to sealed-source exposures. Second, the authors performed imaging experiments with a 27-keV monoenergetic synchrotron beam and a slit to calculate the total signal generated in terms of optical photons per keV. The results of both methods are compared to simulations obtained with hybridMANTIS, a coupled x-ray, electron, and optical photon Monte Carlo transport package. The authors report line response (LR) and light output for a range of linear absorption coefficients and describe a model that fits at the same time the light output and the blur measurements. Comparing the experimental results with the simulations, the authors obtained an estimate of the absorption coefficient for the model that provides good agreement with the experimentally measured LR. Finally, the authors report light output simulation results and their dependence on scintillator thickness and reflectivity of the backing surface. Results: The slit images from the synchrotron were analyzed to obtain a total light output of 48 keV{sup −1} while measurements using the fast PMT instrument setup and sealed-sources reported a light output of 28 keV{sup −1}. The authors attribute the difference in light output estimates between the two methods to the difference in time constants between the camera and PMT measurements. Simulation structures were designed to match the light output measured with the camera while providing good agreement with the measured LR resulting in a bulk absorption coefficient of 5 × 10{sup −5} μm{sup −1}. Conclusions: The combination of experimental measurements for microcolumnar CsI:Tl scintillators using sealed-sources and synchrotron exposures with results obtained via simulation suggests that the time course of the emission might play a role in experimental estimates. The procedure yielded an experimentally derived linear absorption coefficient for microcolumnar Cs:Tl of 5 × 10{sup −5} μm{sup −1}. To the author’s knowledge, this is the first time this parameter has been validated against experimental observations. The measurements also offer insight into the relative role of optical transport on the effective optical yield of the scintillator with microcolumnar structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deflection of a monochromatic THz beam by acousto-optic methods

The possibility of controlled deflection of an electromagnetic THz beam of a free-electron laser by acousto-optic (AO) methods has been demonstrated for the first time. The material of the AO deflector was chosen to be single-crystal germanium, which has a fairly large refractive index (n = 4.0) and a relatively low absorption coefficient for electromagnetic waves. The absorption coefficient α in germanium is 0.75 ± 0.02 cm{sup -1} at a wavelength λ = 140 μm. The diffracted beam intensity is shown to be maximum at an effective AO interaction length l = 1/α. A diffraction efficiency of 0.05% at a travelling acoustic wave power of 1.0 W is experimentally obtained. It is established that a change in the ultrasonic frequency from 25 to 39 MHz leads to variation in the external Bragg angle in the range from 19.5° to 27.5°. At a fixed Bragg angle θ{sub B} = 22.4° the frequency band of diffraction is 4.2 ± 0.1 MHz and the angular range of laser beam scanning reaches 2.5° ± 0.5°. The results obtained indicate that AO interaction can be used for controlled deflection of electromagnetic THz beams. (terahertz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of layer thickness on device response of silicon heavily supersaturated with sulfur

We report on a simple experiment in which the thickness of a hyperdoped silicon layer, supersaturated with sulfur by ion implantation followed by pulsed laser melting and rapid solidification, is systematically varied at constant average sulfur concentration, by varying the implantation energy, dose, and laser fluence. Contacts are deposited and the external quantum efficiency (EQE) is measured for visible wavelengths. We posit that the sulfur layer primarily absorbs light but contributes negligible photocurrent, and we seek to support this by analyzing the EQE data for the different layer thicknesses in two interlocking ways. In the first, we use the measured concentration depth profiles to obtain the approximate layer thicknesses, and, for each wavelength, fit the EQE vs. layer thickness curve to obtain the absorption coefficient of hyperdoped silicon for that wavelength. Comparison to literature values for the hyperdoped silicon absorption coefficients [S.H. Pan et al. Applied Physics Letters 98, 121913 (2011)] shows good agreement. Next, we essentially run this process in reverse; we fit with Beer’s law the curves of EQE vs. hyperdoped silicon absorption coefficient for those wavelengths that are primarily absorbed in the hyperdoped silicon layer, and find that the layer thicknesses obtained from the fit are in good agreement with the original values obtained from the depth profiles. We conclude that the data support our interpretation of the hyperdoped silicon layer as providing negligible photocurrent at high S concentrations. This work validates the absorption data of Pan et al. [Applied Physics Letters 98, 121913 (2011)], and is consistent with reports of short mobility-lifetime products in hyperdoped layers. It suggests that for optoelectronic devices containing hyperdoped layers, the most important contribution to the above band gap photoresponse may be due to photons absorbed below the hyperdoped layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Upgrading the sensitivity of spectroscopy gas analysis with application of supersonic molecular beams

We propose an approach to increase a sensitivity of microwave and THz spectroscopy, that involves application of supersonic molecular beams. The key advantage offered by such an approach is that a gas temperature can be decreased along with an increase in the gas density, which results in a much greater number of molecules interacting with radiation and, hence, in a higher absorption coefficient. This effect has been demonstrated experimentally on supersonic CO and NO beams, using a phase manipulation microwave spectrometer. The absorption coefficient was found to be three orders of magnitude higher than the value of gas absorption coefficient in a standard 1-m long cell at room temperature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of optical absorption in polycrystalline CVD diamond plates by the phase photothermal method at a wavelength of 10.6 {mu}m

A highly-efficient phase photothermal method is developed for quantitative measurements of the small optical absorption coefficient in thin plates made of highly transparent materials in which bulk losses significantly exceed surface losses. The bulk absorption coefficient at 10.6 {mu}m is estimated in polycrystalline diamond plates grown from the vapour phase (a CVD diamond). The results are compared with those for natural and synthetic diamond single crystals and with the concentrations of nitrogen and hydrogen impurities. The absorption coefficient of the best samples of the CVD diamond did not exceed 0.06 cm{sup -1}, which, taking into account the high thermal conductivity of the CVD diamond (1800-2200 W mK{sup -1} at room temperature), makes this material attractive for fabricating output windows of high-power CO{sub 2} lasers, especially for manufacturing large-size optics. (laser applications and other topics in quantum electronics)

36 MATERIALS SCIENCE↗

Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation

Purpose: The aim of this study was to develop novel methods for photoacoustically determining the optical absorption coefficient of biological tissues using Monte Carlo (MC) simulation. Methods: In this study, the authors propose two quantitative photoacoustic tomography (PAT) methods for mapping the optical absorption coefficient. The reconstruction methods combine conventional PAT with MC simulation in a novel way to determine the optical absorption coefficient of biological tissues or organs. Specifically, the authors’ two schemes were theoretically and experimentally examined using simulations, tissue-mimicking phantoms, ex vivo, and in vivo tests. In particular, the authors explored these methods using several objects with different absorption contrasts embedded in turbid media and by using high-absorption media when the diffusion approximation was not effective at describing the photon transport. Results: The simulations and experimental tests showed that the reconstructions were quantitatively accurate in terms of the locations, sizes, and optical properties of the targets. The positions of the recovered targets were accessed by the property profiles, where the authors discovered that the off center error was less than 0.1 mm for the circular target. Meanwhile, the sizes and quantitative optical properties of the targets were quantified by estimating the full width half maximum of the optical absorption property. Interestingly, for the reconstructed sizes, the authors discovered that the errors ranged from 0 for relatively small-size targets to 26% for relatively large-size targets whereas for the recovered optical properties, the errors ranged from 0% to 12.5% for different cases. Conclusions: The authors found that their methods can quantitatively reconstruct absorbing objects of different sizes and optical contrasts even when the diffusion approximation is unable to accurately describe the photon propagation in biological tissues. In particular, their methods are able to resolve the intrinsic difficulties that occur when quantitative PAT is conducted by combining conventional PAT with the diffusion approximation or with radiation transport modeling.

60 APPLIED LIFE SCIENCES↗

Quantification of water in majoritic garnet

Majoritic garnet, characterized by an excess of silicon (>3 Si per formula unit), is considered one of the major phases of the Earth’s transition zone from 410-660 km depth. Quantifying the H 2 O content of nominally anhydrous mantle minerals is necessary to evaluate their water storage capacity from experiments and modeling the Earth’s deep water cycle. We present mineral-specific infrared absorption coefficients for the purpose of quantifying the amount of water incorporated into majorite as hydroxyl point defects. A suite of majoritic garnet samples with varying proportions of Si, Fe, Al, Cr and H 2 O was synthesized at conditions of 18-19 GPa and 1500-1800°C. Single-crystals were characterized using X-ray diffraction, electron microprobe analysis, secondary Ion Mass spectrometry (SIMS), IR, Raman and Mössbauer spectroscopy. We utilize SIMS and Raman spectroscopy in combination with IR spectroscopy to provide IR absorption coefficients for water in majoritic garnets with the general mineral formula (Mg,Fe) 3 (Si,Mg,Fe,Al,Cr) 2 [SiO4] 3 . Furthermore, the IR absorption coefficient for majoritic garnet in the OH stretching region is frequency-dependent and ranges from 10 470 ± 3100 Lmol-1cm-2 to 23 400 ± 2300 Lmol -1 cm -2 .

36 MATERIALS SCIENCE↗

The effect of temperature on soot properties in premixed methane flames

The effect of flame temperature on soot properties was studied in premixed methane/oxygen flames burning at a constant mixture composition (C/O = 0.60, {phi} = 2.4) and different cold-gas flow velocities (4 and 5 cm s{sup -1}). Temperature and concentration profiles of stable gases and condensed phases combustion products were measured along the flame axis. It was found that the high flame temperature conditions cause a larger decomposition of methane into hydrogen and C{sub 2}-C{sub 4} hydrocarbons, thereby reducing the formation of benzene and condensed phases including condensed species and soot. Soot properties were studied by UV-Visible absorption spectroscopy, thermogravimetry and H/C elemental analysis. A description of soot nanostructural organization was also performed by means of high-resolution transmission electron microscopy. Different properties and nanostructures were found to develop in the soot, depending on the temperature and on soot aging associated. Soot dehydrogenation occurred to a larger extent in the high flame temperature conditions. As soot dehydrogenates the mass absorption coefficients of soot exhibited an increasing trend along the flame axis. However, mature soot retained a relatively high H/C ratio and low absorption coefficients with respect to other less hydrogenated fuels even in high temperature conditions. This indicates that the aromatization/dehydrogenation of soot in premixed flames is more dependent on the fuel characteristics rather than on the flame temperature. Generally, it was assessed that mature soot produced from diverse hydrocarbon fuels with similar flame temperatures and flame types possess a different chemical composition and structure. To this regard the H/C atomic ratio and mass absorption coefficients appeared to be signatures of soot properties and structural evolution. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absorption properties of type-II InAs/InAsSb superlattices measured by spectroscopic ellipsometry

Strain-balanced InAs/InAsSb superlattices offer access to the mid- to long-wavelength infrared region with what is essentially a ternary material system at the GaSb lattice constant. The absorption coefficients of InAs/InAsSb superlattices grown by molecular beam epitaxy on (100)-oriented GaSb substrates are measured at room temperature over the 30 to 800 meV photon energy range using spectroscopic ellipsometry, and the miniband structure of each superlattice is calculated using a Kronig-Penney model. The InAs/InAsSb conduction band offset is used as a fitting parameter to align the calculated superlattice ground state transition energy to the measured absorption onset at room temperature and to the photoluminescence peak energy at low temperature. It is observed that the ground state absorption coefficient and transition strength are proportional to the square of the wavefunction overlap and the ground state absorption coefficient approaches a maximum value of around 5780 cm{sup −1} as the wavefunction overlap approaches 100%. The absorption analysis of these samples indicates that the optical joint density of states is weakly dependent on the period thickness and Sb content of the superlattice, and that wavefunction overlap is the principal design parameter in terms of obtaining strong absorption in these structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic field control of the intraband optical absorption in two-dimensional quantum rings

Linear and nonlinear optical absorption coefficients of the two-dimensional semiconductor ring in the perpendicular magnetic field B are calculated within independent electron approximation. Characteristic feature of the energy spectrum are crossings of the levels with adjacent nonpositive magnetic quantum numbers as the intensity B changes. It is shown that the absorption coefficient of the associated optical transition is drastically decreased at the fields corresponding to the crossing. Proposed model of the Volcano disc allows to get simple mathematical analytical results, which provide clear physical interpretation. An interplay between positive linear and intensity-dependent negative cubic absorption coefficients is discussed; in particular, critical light intensity at which additional resonances appear in the total absorption dependence on the light frequency is calculated as a function of the magnetic field and levels' broadening.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-E-18A-05: Bremsstrahlung of Laser-Plasma Interaction at KeV Temperature: Forward Dose and Attenuation Factors

Purpose: To obtain an analytical empirical formula for the photon dose source term in forward direction from bremsstrahlung generated from laser-plasma accelerated electron beams in aluminum solid targets, with electron-plasma temperatures in the 10–100 keV energy range, and to calculate transmission factors for iron, aluminum, methacrylate, lead and concrete and air, materials most commonly found in vacuum chamber labs. Methods: Bremsstrahlung fluence is calculated from the convolution of thin-target bremsstrahlung spectrum for monoenergetic electrons and the relativistic Maxwell-Juettner energy distribution for the electron-plasma. Unattenuatted dose in tissue is calculated by integrating the photon spectrum with the mass-energy absorption coefficient. For the attenuated dose, energy dependent absorption coefficient, build-up factors and finite shielding correction factors were also taken into account. For the source term we use a modified formula from Hayashi et al., and we fitted the proportionality constant from experiments with the aid of the previously calculated transmission factors. Results: The forward dose has a quadratic dependence on electron-plasma temperature: 1 joule of effective laser energy transferred to the electrons at 1 m in vacuum yields 0,72 Sv per MeV squared of electron-plasma temperature. Air strongly filters the softer part of the photon spectrum and reduce the dose to one tenth in the first centimeter. Exponential higher energy tail of maxwellian spectrum contributes mainly to the transmitted dose. Conclusion: A simple formula for forward photon dose from keV range temperature plasma is obtained, similar to those found in kilovoltage x-rays but with higher dose per dissipated electron energy, due to thin target and absence of filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-E-18A-06: To Remove Or Not to Remove: Comfort Pads From Beneath Neonates for Radiography

Purpose: To obtain an analytical empirical formula for the photon dose source term in forward direction from bremsstrahlung generated from laser-plasma accelerated electron beams in aluminum solid targets, with electron-plasma temperatures in the 10–100 keV energy range, and to calculate transmission factors for iron, aluminum, methacrylate, lead and concrete and air, materials most commonly found in vacuum chamber labs. Methods: Bremsstrahlung fluence is calculated from the convolution of thin-target bremsstrahlung spectrum for monoenergetic electrons and the relativistic Maxwell-Juettner energy distribution for the electron-plasma. Unattenuatted dose in tissue is calculated by integrating the photon spectrum with the mass-energy absorption coefficient. For the attenuated dose, energy dependent absorption coefficient, build-up factors and finite shielding correction factors were also taken into account. For the source term we use a modified formula from Hayashi et al., and we fitted the proportionality constant from experiments with the aid of the previously calculated transmission factors. Results: The forward dose has a quadratic dependence on electron-plasma temperature: 1 joule of effective laser energy transferred to the electrons at 1 m in vacuum yields 0,72 Sv per MeV squared of electron-plasma temperature. Air strongly filters the softer part of the photon spectrum and reduce the dose to one tenth in the first centimeter. Exponential higher energy tail of maxwellian spectrum contributes mainly to the transmitted dose. Conclusion: A simple formula for forward photon dose from keV range temperature plasma is obtained, similar to those found in kilovoltage x-rays but with higher dose per dissipated electron energy, due to thin target and absence of filtration.

07 ISOTOPE AND RADIATION SOURCES↗